• Title/Summary/Keyword: Raman Spectrometer

Search Result 76, Processing Time 0.027 seconds

A Study on Data Classification of Raman OIM Hyperspectral Bone Data

  • Jung, Sung-Hwan
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.8
    • /
    • pp.1010-1019
    • /
    • 2011
  • This was a preliminary research for the goal of understanding between internal structure of Osteogenesis Imperfecta Murine (OIM) bone and its fragility. 54 hyperspectral bone data sets were captured by using JASCO 2000 Raman spectrometer at UMKC-CRISP (University of Missouri-Kansas City Center for Research on Interfacial Structure and Properties). Each data set consists of 1,091 data points from 9 OIM bones. The original captured hyperspectral data sets were noisy and base-lined ones. We removed the noise and corrected the base-lined data for the final efficient classification. High dimensional Raman hyperspectral data on OIM bones was reduced by Principal Components Analysis (PCA) and Linear Discriminant Analysis (LDA) and efficiently classified for the first time. We confirmed OIM bones could be classified such as strong, middle and weak one by using the coefficients of their PCA or LDA. Through experiment, we investigated the efficiency of classification on the reduced OIM bone data by the Bayesian classifier and K -Nearest Neighbor (K-NN) classifier. As the experimental result, the case of LDA reduction showed higher classification performance than that of PCA reduction in the two classifiers. K-NN classifier represented better classification rate, compared with Bayesian classifier. The classification performance of K-NN was about 92.6% in case of LDA.

A Basic Study for the Performance Evaluation of a Raman LiDAR Detector for Detecting Hydrogen Gas (수소 가스 검출용 라만 라이다 측정기의 성능 평가를 위한 기초 연구)

  • WONBO CHO;YUNKYU LIM;YANGKYUN KIM;BYOUNGJIK PARK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.2
    • /
    • pp.205-211
    • /
    • 2023
  • Hydrogen gas is light and diffuses very quickly. Therefore, when a leakage accident occurs, the damage is great, so a technology that can quickly measure the leakage in the air at a long distance is needed. In order to develop hydrogen gas leaked in the atmosphere in a non-contact manner, an experiment was performed to measure hydrogen gas using a lidar technology using the Raman effect. Hydrogen Raman signals were detected using a UV LED light source, which is a Raman light source, and a spectrometer in the ultraviolet region including an optical filter in the 400-430 nm band. To develop this, a Raman lidar optical structure was designed to measure the hydrogen Raman signal at a certain distance, and the hydrogen Raman spectrum was confirmed using a standard gas to evaluate the performance of this optical structure. The linearity was found to be 0.99 using hydrogen standard gas (10, 50, 100, 500, 1,000 ppm). Accordingly, a Raman lidar capable of measuring hydrogen gas rapidly diffusing in the air in an open state was developed to improve the limitations of existing hydrogen sensors.

Micro-pinholes in Composite Cobalt Nickel Silicides (코발트 니켈 합금 구조에서 생성된 실리사이드의 마이크로 핀홀의 발생)

  • Song, Oh-Sung;Kim, Sang-Yeob;Jeon, Jang-Bae;Kim, M.J.
    • Korean Journal of Materials Research
    • /
    • v.16 no.10
    • /
    • pp.656-662
    • /
    • 2006
  • We fabricated thermal evaporated 10 nm-$Ni_xCo_{1-x}$ (x=0.2, 0.5 and 0.8) /(poly)Si films to form nanothick cobalt nickel composite silicides by a rapid thermal annealing at $700{\sim}1100^{\circ}C$ for 40 seconds. A field emission scanning electron microscope and a micro-Raman spectrometer were employed for microstructure and silicon residual stress characterization, respectively. We observed self-aligned micro-pinholes on single crystal silicon substrates silicidized at $1100^{\circ}C$. Raman silicon peak shift indicates that the residual tensile strain of $10^{-3}$ in single crystal silicon substrates existed after the silicide process. We propose thermal stress from silicide exothermic reaction and high temperature silicidation annealing may cause the pinholes. Those pinholes are expected to be avoided by lowering the silicidation temperature. Our results imply that we may use our newly proposed composite silicides to induce the appropriate strained layer in silicion substrates.

Cluster ing for Analysis of Raman Hyper spectral Dental Data

  • Jung, Sung-Hwan
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.1
    • /
    • pp.19-28
    • /
    • 2013
  • In this research, we presented an effective clustering method based on ICA for the analysis of huge Raman hyperspectral dental data. The hyperspectral dataset captured by HR800 micro Raman spectrometer at UMKC-CRISP(University of Missouri-Kansas City Center for Research on Interfacial Structure and Properties), has 569 local points. Each point has 1,005 hyperspectal dentin data. We compared the clustering effectiveness and the clustering time for the case of using all dataset directly and the cases of using the scores after PCA and ICA. As the result of experiment, the cases of using the scores after PCA and ICA showed, not only more detailed internal dentin information in the aspect of medical analysis, but also about 7~19 times much shorter processing times for clustering. ICA based approach also presented better performance than that of PCA, in terms of the detailed internal information of dentin and the clustering time. Therefore, we could confirm the effectiveness of ICA for the analysis of Raman hyperspectral dental data.

The Investigation of Electro-Oxidation of Methanol on Pt-Ru Electrode Surfaces by in-situ Raman Spectroscopy

  • She, Chun-Xing;Xiang, Juann;Ren, Bin;Zhong, Qi-Ling;Wang, Xiao-Cong;Tian, Zhong-Qun
    • Journal of the Korean Electrochemical Society
    • /
    • v.5 no.4
    • /
    • pp.221-225
    • /
    • 2002
  • Assisted by the highly sensitive confocal microprobe Raman spectrometer and proper surface roughening procedure, the Raman investigation on the adsorption and reaction of methanol was performed on Pt-Ru electrodes with different coverages. A detailed description of the roughening process of the Pt electrodes and the underpotential deposition of the Ru was given. Reasonably good Raman signal reflecting the metal-carbon vibration and CO vibration was detected. The appearance of vibrations of the Ru oxides, together with the existence of Ru-C, Pt-C and CO bands, clearly demonstrates the participation of the bi-functional mechanism during the oxidation process of methanol on Pt-Ru electrodes. The Pt-Ru electrode was found to have a higher catalytic activity over Pt electrodes. This preliminary study shows that electrochemical Raman spectroscopy can be applied to the study of rough electrode surface.

CuO Nanograss as a Substrate for Surface Enhanced Raman Spectroscopy

  • Lee, Jun-Young;Park, Jiyun;Kim, Jeong-Hyun;Yeo, Jong-Souk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.249-249
    • /
    • 2013
  • Surface-enhanced Raman spectroscopy (SERS) is a sensitive approach to detect and to identify a variety of molecules. To enhance the Raman signal, optimization of the gap between nanostructures is quite important. One-dimensional materials such as nanowires, nanotubes, and nanograsses have great potential to be used in SERS due to their unique sizes and shape dependent characteristics. In this study we investigate a simple way to fabricate SERS substrates based on randomly grown copper oxide (CuO) nanowires. CuO nanograss is fabricated on pre-cleaned Cu foils. Cu oxidized in an ammonium ambient solution of 2.5 M NaOH and 0.1 M $(NH_4)_2S_2O_8$ at $4^{\circ}C$ for 10, 30, and 60 minutes. Then, Cu(OH)2 nanostructures are formed and dried at $180^{\circ}C$ for 2 h. With the drying process, the Cu(OH)2 nanostructure is transformed to CuO nanograss by dehydration reaction. CuO nanograss are grown randomly on Cu foil with the average length of 10 ${\mu}m$ and the average diameter of a 100 nm. CuO nanograsses are covered by Ag with various thicknesses from 10 to 30 nm using a thermal evaporator. Then, we immerse uncoated and Ag coated CuO nanowire samples of various oxidation times in a 0.001M methanol-based 4-mercaptopyridine (4-Mpy) in order to evaluate SERS enhancement. Raman shift and SERS enhancement are measured using a Raman spectrometer (Horiba, LabRAM ARAMIS Spectrometer) with the laser wavelength of 532 nm. Raman scattering is believed to be enhanced by the interaction between CuO nanograss and Ag island film. The gaps between Ag covered CuO nanograsses are diverse from <10 nm at the bottom to ~200 nm at the top of nanograsses. SERS signal are improved where the gaps are minimized to near 10s of nanometers. There are many spots that provide sufficiently narrow gap between the structures on randomly grown CuO nanograss surface. Then we may find optimal enhancement of Raman signal using the mapping data of average results. Fabrication of CuO nanograss based on a solution method is relatively simple and fast so this result can potentially provide a path toward cost effective fabrication of SERS substrate for sensing applications.

  • PDF

Micro Raman Spectroscopic Analysis of Local Stress on Silicon Surface in Semiconductor Fabrication Process (반도체 제조 공정에서 실리콘 표면에 유입된 Stress의 마이크로 Raman 분광분석)

  • Son, Min Young;Jung, Jae Kyung;Park, Jin Seong;Kang, Sung Chul
    • Analytical Science and Technology
    • /
    • v.5 no.4
    • /
    • pp.359-366
    • /
    • 1992
  • Using micro-Raman spectrometer, we investigated the evaluation of microstress on silicon surface after the local thermal oxidation. The induced stress of silicon surface after local thermal oxidation shows maximum value at the interface of silicon oxide and active area. The smaller the size of active area, the larger stress. From the evaluation of three other device isolation processes, A, B and moB, whose active size has $0.45{\mu}m$ in length, moB process is turned out to have the lowest stress value and the smallest bird's beak effect.

  • PDF

A Study on Spectroscopic Analysis by using Raman Spectrometer of Multi-Guest Mixed Hydrates Containing $SF_6$ (Raman Spectroscopy를 이용한 $SF_6$ 혼합 하이드레이트의 분광학적 해석에 관한 연구)

  • Shin, H.J.;Moon, D.H.;Kim, M.C.;Kim, Y.S.;Seo, Y.W.;Lee, G.W.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.223-225
    • /
    • 2008
  • 하이드레이트는 저온.고압에서 저분자량의 게스트(guest)가 호스트(host)인 물분자 속에 포획되어 만들어지는데 일련의 과정은 물리적 반응을 통해 생성된다.본 연구에서는$CO_2$보다 지구온난화지수(Global Warming Potential)가 23,900배 높은 $SF_6$의 회수 및 정제기술로써 하이드레이트화를 이용하는 신기술 개발의 일환으로 분광학적 접근을 통해 $SF_6$ 혼합 하이드레이트의 정성 및 정량분석을 수행하였다. Raman Shift 분석 결과 $SF_6$$770cm^{-1}$에서 $v_1$ 진동주파수를 확인함으로써 하이드레이트 내 $SF_6$가 안정적으로 포집됨을 확인하였고 혼합가스 내 $SF_6$ 농도별로 만들어진 샘플의 Raman Shift를 통해서 $SF_6$의 하이드레이트 전환율을 가늠할 수 있었다.

  • PDF

Construction and performance test of a coherent anti-Stokes Raman spectrometer (코헤런트 라만 분광기 제작 및 성능검사)

  • 한재원
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1991.06a
    • /
    • pp.150-155
    • /
    • 1991
  • 연소기체의 진단연구에 응용하기 위한 코헤런트 라만분광기를 설계·제작하여 성능을 조사하였다. 광원으로는 단일 종모드로 발진하는 Nd:YAG 레이저의 이차고조파와 색소 레이저를 이용하였다. Collinear 방법으로 상온의 질소기체 압력을 변화시키면서 분광 신호를 측정하였으며, 제작된 분광기 성능에 대하여 논의하였다.

  • PDF

Development of Raman Laser Radar System for Aerosol and Water Vapor Measurements (에어로졸, 수증기 측정 라만 레이저 레이다 시스템 개발)

  • Park, Chan-Bong;Lee, Young-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.158-161
    • /
    • 2012
  • Raman Laser Radar system for the measurements of aerosol and water vapor concentration is developed. As a transmitting system, Nd:YAG laser with 3rd harmonic Generator and beam expander are used. The wavelength of transmitting laser is 355 nm. The receiving system is consists of 500 mm telescope, 3-channel Raman spectrometer, PMT, and signal processing module. The wavelengths of received signals are 355 nm. 387 nm, and 408 nm 이다. The measurable altitude of this system is about 3~4 km with spatial resolution of 100~200 m.

  • PDF