• Title/Summary/Keyword: Railway feeding system

Search Result 117, Processing Time 0.022 seconds

Considering design parameters in terms of rail potential and leakage current in DC feeding system (직류급전시스템의 레일전위와 누설전류 관점에서의 설계 파라미터 연구)

  • Han, Moon-Seob;Jung, Ho-Sung
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.236-241
    • /
    • 2007
  • DC feeding system is mainly floating but the rail potential and the leakage current are created because of long parallelism between rails and ground. Rail potential causes electric shock to human and leakage current causes electrolytic corrosion to nearby the buried metals. Therefore the design technologies to reduce, protect and monitor these effects are important recent DC feeding system. Normally during designing DC feeding system in terms of rail potential and leakage current, there are about 10 parameters. Four design parameters among those is analysed based on propagation theory that is utilized in order to simulate grounding system.

  • PDF

Evaluation of Rail Leakage Current and Potential in DC Railway (직류철도의 레일누설전류 밑 전위평가)

  • Han, Moon-Seob;Jung, Ho-Sung;Kim, Ju-Rak;Kil, Gyung-Suk
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.1
    • /
    • pp.161-166
    • /
    • 2009
  • DC feeding system is mainly floating but rail potential and leakage current are due to long parallelism between rails and ground, namely rail resistance and rail to ground conductance. Rail potential causes electric shock to human and rail leakage current causes electrolytic corrosion to nearby the buried metals. Therefore the design technologies to reduce, protect and monitor these effects are important in recent DC feeding system. Rail potential and leakage current are analysed based on propagation theory that is utilized. Monitoring and controlling rail leakage current is proposed in order to maintain rail resistance and rail to ground conductance.

Steady State Analysis for Power System of HSR with Active Transformer

  • Kim, Wook-Won;Kim, Hyung-Chul;Shin, Seung-Kwon;Kim, Jin-O
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.257-264
    • /
    • 2016
  • In this paper, new electric railway feeding system which has active transformer is modeled for evaluating the steady state analysis using PSCAD/EMTDC. Equivalent models including power supply, feeder, train and transformers are proposed for simplifying the model of the feeding system in high speed electric railway. In case study, simulation results applied to proposed model are compared with the conventional and new systems through the catenary voltage, three-phase voltage of PCC (Point of Common Coupling) and the efficiency of regenerative braking energy.

Harmonic Generation and System Response Characteristics in Electrified Railway(I) - Focused on System Response Characteristics - (전기철도에서의 고조파 발생과 계통응답특성(I) - 계통응답특성을 중심으로 -)

  • Oh Kwang-Hae;Lee Chang-Mu
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.493-498
    • /
    • 2003
  • Harmonic current originating from electric locomotives can be magnified due to the impedance characteristics of power supply circuit and bring about various problems. That is, electromagnetic interference with communication lines, operational trouble in signaling, overheat and/or vibration in power capacitor, mis-operation in protection relay and so on. Therefore, the exact assessment of the harmonic current flow must be undertaken at design and planning stage for the electric traction systems. For these reasons, this study propose a new approach to model and to analyse traction power feeding system focused on system response to current and voltage harmonic(PART I ). Measurements of harmonics are also performed for railway power supply systems under normal operation. Spectrum and distortion analyses in measurement data are variously described in PART II

  • PDF

A Study of LA Counter Over-activation in AC Electric railway Substation (AC 전철변전소의 피뢰기카운터 과동작에 관한 연구)

  • Cheon, Hee-Seung;Jang, Woo-Jin
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.132-139
    • /
    • 2008
  • In an electric railway feeding system, transient over-voltage often appears due to the feeder's direct lightning and induced lightning, while switching over-voltage also frequently occurs during operation of electric feeding in substation facilities. Such over-voltage is several times larger than the regular power, and accordingly leads to the dieletric breakdown of eletric power products such as invasion transformers and circuit breakers. Arresters are installed to protect these machines, while arrester counters are installed to observe the arrester's activation. This thesis aims to explore the status of an arrester counter that is being activated several thousand times, determine whether the arrester has actually been activated in relation to the counter, and investigate the over-heatedness and risks of the arrester.

  • PDF

Evaluation of the variable TAB Autotransformer for ascending collecting Voltage (집전전압 향상을 위한 가변탭 단권변압기 검토)

  • Lee, Chang-Mu;Han, Moon-Seub;Lee, Han-Min
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1426-1430
    • /
    • 2009
  • AC AT feeding method consists return circuits of electric train inserting in parallel between trolly line and feeding line and connecting neutral line to rail and FPW. Due to increasing electric load at feeding system, collecting voltage of train and end voltage are going down. So to increase voltage between trolly line and rail, the usefulness of new autotransformer are considered which variation of short impedance and change of line voltage is simulated with modified winding ratio of autotransformer from 1:1 to variable tab.

  • PDF

A Study on Durability Standard Specification of the Dropper Clamp of Catenary for High Speed Railway (고속철도 전차선로 드로퍼 클램프 내구성 기준 정립에 관한 연구)

  • Oh, Wan-Shik;Yang, In-Dong;Park, Byung-Gon;Hong, Seok-Jin;Kim, Seong-Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.9
    • /
    • pp.1431-1436
    • /
    • 2017
  • The high-speed railway of catenary system, supplies a stable electric power supply to the train by satisfying the special conditions between pantograph and trolley wire, which operates more than 250km/h mutually sliding and feeding electric lines. According to Korean Railway Standard KRS PW 0026-13 (R), the standard for the grip strength of the dropper clamp in conventional line is established, but the high-speed railway line is not yet. When the grip strength of the dropper clamp is detached from the catenary line of the high-speed railway line, various problems may occur, such as damage to the pantograph due to the collision and arcing. In this paper, it is expected to be used as a basic data for establishing the durability criteria of the high-speed railway dropper clamp by verifying the dropper clamp on the Gyeong-bu and Honam high-speed line.

Harmonic Generation and System Response Chartcteristics in Electrified Railway(II) - Focused on Measurement and Analysis - (전기철도에서의 고조파 발생과 계통응답특성(II) - 고조파 측정분석을 중심으로 -)

  • Oh Kwang-Hae;Lee Han-Min
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.499-504
    • /
    • 2003
  • Harmonic current originating from electric locomotives can be magnified due to the impedance characteristics of power supply circuit and bring about various problems. That is, electromagnetic interference with communication lines, operational trouble in signaling, overheat and/or vibration in power capacitor, mis-operation in protection relay and so on. Therefore, the exact assessment of the harmonic current flow must be undertaken at design and planning stage for the electric traction systems. For these reasons, this study propose a new approach to model and to analyse traction power feeding system focused on system response to current and voltage harmonic(PART I ). Measurements of harmonics are also performed for railway power supply systems under normal operation. Spectrum and distortion analyses in measurement data are variously described in PART II

  • PDF

A Study on the Loop Current Induced by Voltage Phase Difference Substations during Parallel Feeding under the Alternating Current AT Electric Power Feeding Method (교류 AT급전방식에서 병렬급전시 변전소간 전압위상차에 의한 루프전류에 관한 연구)

  • Park, Jae-Seok;Song, Joong-Ho
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1997-2004
    • /
    • 2011
  • The $2{\times}25kv$ AT electric power feeding method in the A.C. electric train adopts the one-phase power feeding method as the standard due to a voltage phase difference, and the distance between the two neighboring substations is 50km due to voltage drop. The one-phase power feeding method makes the system operation feasible, while making it unfavorable for power supply. Moreover, railroad involves large-capacity single-phase load, and if it is expected to continue to rise, it is necessary to research on measures to stabilize the supply of power to railroad cars with the existing facilities. In this study, a parallel power feeding method between neighboring substations is proposed to stabilize the supply of electric power to electric railroad cars under the 2*25kv AT power feeding method and the loop current induced by voltage phase difference between the two neighboring substations during parallel power feeding is investigated.

  • PDF