• Title/Summary/Keyword: Railway feeder system

Search Result 57, Processing Time 0.023 seconds

A Study on the Possibilities of PRT Applications (소형궤도차량(PRT)의 국내 적용시 정책적 검토 사항 연구)

  • Lee, Jin-Sun;Kim, Kyoung-Tae
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.4
    • /
    • pp.526-534
    • /
    • 2009
  • PRT(Personal Rapid Transit) can be described as a system of driverless taxicabs, that. automatically take passengers to their destinations along dedicated guideways, without intermediate stops.It is ideally suited as a short feeder transportation for on-demand circulation operations at train stations, airports, office complex, amusement park and shopping center. This PRT study do suggest that a PRT system could provide a high level of mobility to the commuters making work trips, workers making work, shopping and other non-work trips, residents making shopping and other non-work trips and recreational riders.This study presents the possibilities of PRT applications in national level. As the technology continues to advance, there may be opportunities to improve the reliability, and efficiency of our future public transportation systems.

A Power Losses Analysis of AC Railway Power Feeding Network using Adaptive Voltage Control (능동형 전압제어를 통한 교류 전기철도 급전망에 대한 전력손실 분석)

  • Jung, Hosung;Kim, Hyungchul;Shin, Seongkuen;Kim, Jinho;Yoon, Kiyong;Cho, Yonghyeun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.11
    • /
    • pp.1621-1627
    • /
    • 2013
  • This paper compares power losses between voltage controlled before and after using power conversion device in AC feeding system. For this purpose we present voltage control procedures and criteria and model high speed line and train using PSCAD/EMTDC to compare power losses in various feeding condition. Power losses of the simulation result in power control before and after in single point feeding system was reduced maximum 0.37 MW(23.8 %) and average 0.23 MW(20.5 %) when one vehicle load operates maximum load condition. When three vehicles operate maximum load condition in one feeder section, power losses after voltage control was reduced 1.03 MW(49.5%) compared to before voltage control. And, power loss of parallel feeding system is reduced the average 0.08 MW(7.2 %) compared to the single feeding system. In conclusion, adaptive voltage control method using power conversion device can reduce power losses compared with existing method.

Rail Toward River: The Relationship Between Railroad and River Transportation in Korea During Japanese Rule

  • Dodoroki, Hiroshi
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.4
    • /
    • pp.348-351
    • /
    • 2013
  • The aim of this research is to analyze and periodize the relationship between railroad and river transportation as one aspect of the transformation of the land transportation system in Korea. As a result, three phases can be observed: a first phase of equality and interdependence (1910s); a second phase, subordinating rivers to feeder lines under railroad's dominance; and a third phase when trucks and buses became a major means for local transportation in place of traditional shipping routes. River ports were among the main planned destinations during the first and second phases, but such plans were changed or withdrawn after the third phase. This relationship between river and rail illustrates one geopolitical factor relating to the development of Korea's rail transportation network.

Harmonic Frequency Analysis of Interlocking System for Rolling Stock Operation in Electrical Railroads (전기철도 구간에서의 철도차량 운행에 따른 연동장치 고조파 분석)

  • Baek, Jong-Hyen;Kim, Yong-Kyu;Oh, Seh-Chan;Lee, Kang-Mi;Jo, Hyun-Jeong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.8
    • /
    • pp.3610-3616
    • /
    • 2011
  • Electrical Railroads provide electric power, which can operate vehicles, via feeder wires. And the supplied current returns to the transformer substation through lines and ground net. The used load current depending on the operation of rail vehicles in the electric railway sections returns to the substation through a track which is a return circuit. The load current contains harmonics because of the power conversion equipment used in rolling stocks and such harmonic currents should not affect train control system. In this paper we present the test result in order to verify that the harmonics produced by the operation of rail vehicles in the newly built electric railway sections can affect interlocking systems. The test in question was performed in a linking section that trackside equipment under railway operating conditions and interlocking are linked in order to identify whether or not the interlocking fitted in a signal machine room can be affected by harmonics according to railway operation.

Analysis on the RFI Noise Path of Electrical Railway System in the Frequency Range of 9 kHz to 150 kHz (전기철도 시스템의 9~150 kHz 대역에서의 RFI 노이즈 전달 경로 분석)

  • Kwun, Suk-Tai;Chung, Yeon-Choon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.12
    • /
    • pp.1373-1379
    • /
    • 2012
  • The interaction of magnetic field in the frequency range of 9~150 kHz radiating from a railway system with wireless systems has been the cause of radio frequency interference. In this paper, the equivalent circuit model of the RFI noise is proposed through source and transfer path analysis, and it is confirmed that the switching noise of several kHz that occurs a vehicle traction drive system and a substation is radiated by forming the loop circuit with a feeder line by a rolling stock. And the validity of the proposed equivalent circuit model is verified by analyzing the effects of RC banks installed in the real railway between Guri and Guksu stations, the RFI noise can be effectively mitigated by loading suitable capacitance between rail and feeding line.

The Reactive Power Compensation for a Feeder by Control of the Power Factor of PWM Converter Trains (PWM 컨버터 차량의 역률 제어를 통한 급전선로의 무효전력 보상)

  • Kim, Ronny Yongho;Kim, Baik
    • Journal of the Korean Society for Railway
    • /
    • v.17 no.3
    • /
    • pp.171-177
    • /
    • 2014
  • PWM converter trains exhibit excellent load characteristics in comparison with conventional phase-controlled trains with low power factors, as they can be operated at power factors which are close to unity by means of a voltage vector control method. However, in the case of a high track density or extended feeding, significant line losses and voltage drops can occur. Instead of operating these trains at a fixed unity power factor, this paper suggests a continuous optimal power factor control scheme for each train in an effort to minimize line losses and improve voltage drops according to varying load conditions. The proposed method utilizes the steepest descent algorithm targeting each car in the same feeding section to establish the optimized reactive power compensation levels that can minimize the reactive power loss of the feeder. The results from a simulation of a sample system show that voltage drops can be improved and line losses decreased.

RC Circuit Parameter Estimation for DC Electric Traction Substation Using Linear Artificial Neural Network Scheme (선형인공신경망을 이용한 직류 전철변전소의 RC 회로정수 추정)

  • Bae, Chang Han;Kim, Young Guk;Park, Chan Kyoung;Kim, Yong Ki;Han, Moon Seob
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.3
    • /
    • pp.314-323
    • /
    • 2016
  • Overhead line voltage of DC railway traction substations has rising or falling characteristics depending on the acceleration and regenerative braking of the subway train loads. The suppression of this irregular fluctuation of the line voltage gives rise to improved energy efficiency of both the railway substation and the trains. This paper presents parameter estimation schemes using the RC circuit model for an overhead line voltage at a 1500V DC electric railway traction substation. A linear artificial neural network with a back-propagation learning algorithm was trained using the measurement data for an overhead line voltage and four feeder currents. The least square estimation method was configured to implement batch processing of these measurement data. These estimation results have been presented and performance analysis has been achieved through raw data simulation.

A study on the efficient operation program of digital protection relay in DC feeder system (DC 급전계통의 디지털 보호계전기의 합리적 운용방안 검토)

  • Lee, Kyung-Goo;Hyun, Yong-Sub;Hong, Sung-Lae;Baek, Jae-Woo;Min, Yong-Ho
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.946-958
    • /
    • 2009
  • Lately, Seoul metro is changing transformation facilities which have been operated in subway line 1 and 2 for a long duration of time. Although the exiting protection relays in DC feeder system have such several functions as 76I, 50, 85, and 64P, the new protective relay have a great variety of functions such as 76I, 76D, DDL-I, DDL-T(Imin), 85, and 64P, as well as record and save various events and accident wave in order to review and analyze the working causes of the protective system. However, because the new digital relays are not used properly for protective propose, there are the cases that the electric accident is deteriorated more. Therefore, in this paper, we will describe that making the use studying installation intention, direction, and setting up value of the protection relay in DC breaker operation not only prevents from making the electric accident worse but also shows the efficient operation method of direct current protection system.

  • PDF

Voltage Unbalance Evaluation in Autotransformer-Fed Electric Railway Systems using Circuit Analysis (회로해석을 이용한 전기철도 급전시스템의 전압불평형 평가)

  • 오광해;차준민
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.4
    • /
    • pp.20-28
    • /
    • 1998
  • This study proposes a new method to estimate voltage unbalance more exactly using Thevenin's equivalent circuit. The conventional simple formula were easily applied to evaluate voltage unbalance. Because the formula was derived on the assumption that traction load would be directly connected to the secondary windings of the main transformer, they could not consider the detailed characteristics of traction power supply system, for example, self and mutual impedances of rail, catenary and return feeder. So, the ac쳐racy of the results could not be guaranteed. The proposed algorithm is applied to a standard autotransformer-fed test system to analyze unbalance phenomena. Through simulations, we could evaluate voltage and current unbalance factors and compare the voltage unbalance of the three transformer connection schemes : single phase, V- and Scott-connections which are required for suitable train operation schedules. Additionally, we could determine the combinations of trains which can be operated under the unbalance factor limits.

  • PDF

Parametric Study for Variable Tap of Autotransformer Neutral in AC Feeding (전기철도 단권변압기 중성점 탭절환 특성연구)

  • Han, Moonseob;Lee, Chang-Mu;Kim, Jae-Won;Chang, Sang-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.1
    • /
    • pp.137-141
    • /
    • 2018
  • The voltage drop is important in electric railway for feeding a huge power of train on fixed feeding area. Nowadays it is tried to operate a high speed trains on conventional lines and there is problem on the voltage drop too. It is simulated on the conditions increased the turn ratio of trolley, installed autotransformer neutral line with variable taps. In result, it is compensated the voltage drop between ATs and better on last AT, not on the position of AT. And it is decreased a return current and neutral current of AT because of unbalance between trolley and feeder. It should be studied faster and more controllable the solid state switchs instead of the mechanical one in order to utilize this system.