• 제목/요약/키워드: Radon concentration measurement

검색결과 44건 처리시간 0.019초

공동주택의 실내공기환경 개선에 관한 연구 (A Study on the Improvement of Indoor Air Quality in Apartment Buildings)

  • 이상형;박진철;이언구
    • 설비공학논문집
    • /
    • 제8권3호
    • /
    • pp.397-412
    • /
    • 1996
  • This study aims to present the fundamental strategies to improve the Indoor Air Quality (IAQ) in apartment buildings. To investigate the concentration of indoor air pollutants such as radon, formaldehyde, and VOCs, both the document survey and the field measurement were conducted. In addition, to identify the source of the air pollutants, the laboratory experiment was carried out for various building materials. Finally, the minimum period to be reserved befor3e building occupation to ensure healthy IAQ, which largely depends on the ventilation rates, was simulated using a simple compuer program. The results of this study can be summarized as follows: 1. In case of newly-constructed apartment houses, concentrations of formaldehyde, VOCs and radon were found to exceed the standard. Meanwhile, at existing apartment houses, concentrations of VOCs, particularly toluene and xylene, highly exceeded the standasrd level. Concentrations of formaldehyde and radon, however, had been lowered according to the duration of occupation. 2. The laboratory experiment of concentration of pollutants per square meter of building material surface area showed that radon gas was much emitted from the gypsumboard; formaldehyde from flooring and wallpaper; and VOCs from paints and kitchen furnishings. The emission rates of formaldehyde and VOCs were proportional to air temperature. 3. According to the simulation of the minimum period to be reserved before occupation, newly-constructed airtight houses required about 190-200 days, and naturally ventialted houses with fully-open-windows required about 20-45days, in order to keep the level of radon gas lower than standard. Therefore, with the current practice, the date of occupation should be delayed for about 15 days.

  • PDF

환경영향평가 단계에서의 라돈 관리에 대한 연구 (Study of Radon Management in the Environmental Impact Assessment Stage)

  • 김임순;오홍석;이관형;김충곤
    • 환경영향평가
    • /
    • 제27권3호
    • /
    • pp.241-250
    • /
    • 2018
  • 최근 유해한 환경요인에 의한 질병발생 등 사람의 건강에 부정적인 영향이 중요하게 다루어지고 있다. 특히, 방사성 물질이며 폐암 1급 발암물질로 알려진 라돈 노출 영향에 관한 연구가 활발해지고 있다. 한국에서도 2018년 1월 1일 이후, 공동주택을 신축할 때 라돈측정이 의무화되었다. 라돈농도를 측정해 지자체에 제출하여야 하며 주민이 볼 수 있는 곳에 공고해야 한다. 라돈은 다중이용시설에 관한 권고 기준만 있었으나 이제는 주택에도 권고기준을 설정하기로 했다. 따라서 이제는 환경영향평가 단계는 물론 사후환경조사에서도 라돈을 관리할 수 있도록 해야 한다. 라돈농도 등의 환경정보와 라돈의 위해성 등 건강 정보도 공유할 수 있어야 하며, 이를 위해 환경영향평가 단계에서 보건전문가의 참여가 필요하다. 환경영향평가 과정에서 라돈이 인체 건강에 미치는 영향을 고려할 수 있도록 토양, 대기질, 위생 공중항목 등을 개선하여야 한다. 라돈의 농도가 권고기준치 이상이면 대안을 마련하고 저감방안을 마련하여야 한다.

활성탄소 입도에 따른 산화마그네슘 경화체의 공극특성과 흡착성능 평가 (Pore Characterisitics and Adsorption Performance Evaluation of Magnesium Oxide Matrix by Active Carbon Particle Size)

  • 편수정;이상수
    • 한국건축시공학회지
    • /
    • 제18권1호
    • /
    • pp.59-65
    • /
    • 2018
  • 라돈가스는 암석이나 토양 등에 존재하는 자연 방사성 물질인 우라늄이 붕괴할 때 발생하는 무색, 무취, 무미의 가스이다. 인체가 연간 노출되는 방사선의 85%는 자연 방사선에 의한 것이고, 그 중 50%가 라돈가스이다. 미국 환경보호청(EPA)의 조사결과에 의하면, 라돈가스에 장시간 노출될 경우 흡연자는 1,000명 중 62명, 비흡연자는 1,000명 중 7명이 폐암 발병률에 노출된다. 이러한 라돈가스의 위해성을 저감하고자 활성탄소를 사용하여 경화체를 제작하여 그에 대한 공극 특성과 라돈가스 저감 특성에 대한 실험을 진행하였다. 활성탄소를 활용하였을 경우, 측정기간이 길어질수록 라돈가스 농도는 급격한 저감과 그래프 상의 변화를 확인할 수 있었다. 또한 활성탄소의 재료적 특성 중 하나인 공극 분포와 미세공 특성을 파악할 수 있다.

부산광역시 일대의 토양 내 라돈 농도 변화 특성 (Characteristics of Radon Variability in Soils at Busan Area)

  • 김진섭;김선웅;이효민;최정윤;문기훈
    • 자원환경지질
    • /
    • 제45권3호
    • /
    • pp.277-294
    • /
    • 2012
  • 부산의 지역의 암석 종류에 따른 토양 내 라돈 농도의 시 공간적 변화 특성과 변화 요인에 대하여 연구하였다. 토양 내 라돈($^{222}Rn$)농도와 암석 및 토양의 모원소($^{226}Ra$,$^{228}Ra$ U, Th)의 농도를 부산지역 24개 지점에서 측정하였다. 모암과 토양 내 이들 모원소들의 분포와 거동 특징을 분석하고 라돈과의 상관성을 상세히 규명하였으며, 지형에 대한 영향도 평가하였다. 토양 내 라돈 농도 측정에는 두 가지 in-situ 방법(soil probe 방법과 지중매설튜브 방법)을 적용하여 측정의 정확성에 대하여 비교하였다. 토양 내 라돈의 공간적 분포는 모암의 암석 종류에 따른 U의 농도를 전반적으로 반영하여, 화산암에 비해 심성암에 높고, 산성암>중성암>염기성암 순으로 높은 변화양상을 보였다. 그러나 동일한 모암에서 유래된 토양내의 라돈 농도에서 큰 폭의 변화가 나타나며, 이는 라돈의 모원소인 U와 $^{226}Ra$의 암석과 토양에서의 현저한 방사능 비평형 결과이다. 따라서 토양 내 라돈 농도는 이들 모원소의 암석과 토양 내 농도와의 상관성은 매우 낮게 나타나며, 암석 내 농도에 비해 토양 내 농도와 더 높은 상관성을 보였다. Th과 $^{228}Ra$은 풍화작용과 토양 발달 특성에 따라 U와 지구화학적 거동 및 부하 특징을 달리하기 때문에, 동일한 모암에서 유래된 토양에서도 토양 특징에 따라 U와 현저히 다른 복잡한 농도 변화 양상을 나타내었다. 지형구배를 이루는 경사지의 동일 심도의 토양 내 라돈농도는 위치에 따라 차이를 나타내며, 모암을 같이하는 잔류토양(부산대 내 19개 지점)내에서는 소규모 지형 변화에 의해 토양 내 라돈 농도가 6.8~29.8Bq/L 범위로 변화하였다. 토양 내 라돈 농도는 토양 특성에 따라, 정반대의 계절적 변화 양상을 보인다. 지중매설튜브 방법이 soil probe 방법에 비해 더욱 정확히 토양 내 라돈농도를 측정할 수 있어, 토양 내 라돈의 시 공간적 변화 특성에 대한 분석에 매우 유용한 것으로 나타났다.

지하수의 라듐/라돈 동시측정을 위한 백그라운드 감마선 제어

  • 이길용;윤윤열;조수영;김용제
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2005년도 총회 및 춘계학술발표회
    • /
    • pp.308-311
    • /
    • 2005
  • [ $^{222}Rn\;and\;^{226}Ra$ ] in groundwater were determined simultaneously using a gamma-spectroscopy. A nitrogen flushing equipment has been used for elimination and stabilization of high and unstable background activity due to the radon and its progenies in counting shield and room. The aim of present work was to control the background activity for simultaneous measurement of radium$(^{226}Ra)$ and radon$(^{222}Rn)$ in groundwater using a gamma-spectrometry. Background activity was about 1.0dps and the standard deviation was about 50%, The background activity could be minimized using nitrogen flushing equipment in the range of 0.1 to 0.5 and the RSD was about 5% at the experimental condition. The detection limit of $^{222}Rn\;and\;^{226}Ra$ in groundwater was 0.5dps/L in the background control method. In most groundwater used in the work, radon activity was more than the detection limit. However, radium activity in some groundwater was less than the detection limit. If the low level radium in groundwater must be measured, preconcentration process such as concentration should be performed before measuring the groundwater.

  • PDF

대기중(大氣中) 라돈 붕괴생성물(崩壞生成物)의 공기중(空氣中) 방사능(放射能) 농도(濃度)의 측정(測定) (The Measurement of Airborne Radon Daughter Concentrations in the Atmosphere)

  • 하정우;이재기;문석형;육종철
    • Journal of Radiation Protection and Research
    • /
    • 제4권1호
    • /
    • pp.5-13
    • /
    • 1979
  • 공기시료채칩 종료후 공기여과지에 채집된 시료중 방사능을 일정한 시간구간을 두어 계측함으로써 얻은 붕괴곡선을 이론적 방법에 의하여 분석할 수 있는 간단한 방법을 개발하였으며, 이 방법을 이용하여 라돈 붕괴생성물 각각의 공기중 방사능 농도를 결정하였다. 라돈 붕괴생성물 각 핵종의 방사능 농도는 알파붕괴, 시료채집시간, 그리고 수치계수의 함수로 표시된 방정식으로 부터 얻었다. 그리고 대기중 라돈 붕괴생성물 개개의 방사평형상태도 또한 조사하였다. TRIGA Mark-III 원자로실내에서 채집한 공기시료는 상당히 비평형상태에 있었다. 라돈 붕괴생성물들 간의 방사성 불평형의 정도는 공기와류조건과 관련된 공기시료 채집시간에 따라 상당히 달라지는 것같았다. 본 연구 결과에서 얻은 자료는 인체 내부방사선 피폭선량평가와 기체 방사성 물질 방출감시기 교정에 유용한 기초자료가될 것이 확실하다.

  • PDF

공기중 라돈 및 라돈 자핵종의 농도 측정 (Measurement of Radon and its Daughters Concentration in Air)

  • 박영웅;하정우;노성기
    • Journal of Radiation Protection and Research
    • /
    • 제14권2호
    • /
    • pp.23-29
    • /
    • 1989
  • 이중관 형태의 라돈 표준선원을 제작하여 루카스셀의 계수치 (cph)를 라돈농도로 나타내기 위한 환산인자를 측정한 결과 라돈 표준선원을 실온으로 하였을 때는 0.031$\pm$0.001 (pCi/l)/(cph/Cell)였다. 사무실 내에서 라돈과 라돈 자핵종의 농도를 측정한 값은 $^{222}Rn,\;{\rightarrow}^{218}Po\;{\rightarrow}^{214}Pb,\;{\rightarrow}^{214}Bi$ 의 평균 농도가 각각 0.87, 0.53, 0.35, 0.26 pCi/l 였다. 이때 전체 방사평형인자와 WL의 평균 값은 각각 0.40, 3.33${\times}10^{-3}$ 이며 측정 지점에서 연간 피폭되는 방사선량으로 환산하면 약 30 mren 이다.

  • PDF

판재형 활성탄을 이용한 라돈 저감 연구 (A Study of Radon Reduction using Panel-type Activated Carbon)

  • 최일홍;강상식;전제훈;양승우;박지군
    • 한국방사선학회논문지
    • /
    • 제11권5호
    • /
    • pp.297-302
    • /
    • 2017
  • 최근 실내공기 중의 라돈기체의 농도를 저감하기 위하여 친환경 숯을 이용한 공기정화 필터 및 건축자재를 개발하기 위한 연구가 활발히 진행되고 있다. 본 연구에서는 종래의 입상 활성탄 필터에 비해 취급이 용이하고, 효율적으로 라돈을 흡착 및 제거할 수 있는 새로운 판재형 활성탄을 설계 및 제작하여 라돈 저감 성능을 평가하였다. 판재형 활성탄은 분말 활성탄과 폴리우레탄 폼을 일정한 비율로 혼합하고 믹싱 및 압착 공정을 통해 성형제품으로 제작하였으며, 다이아몬드 절삭을 통해 2 mm, 4 mm, 6 mm 두께로 각각 제작하였다. 제작된 활성탄 필터에 대한 물리적 특성을 분석하기 위해 비표면적과 휨 강도를 측정을 하였다. 또한, 실내 라돈기체의 저감성능을 평가하기 위해 3개의 아크릴 챔버를 이용하였으며, 일정한 공기유량에 대해 필터 통과 전과 후의 라돈 농도를 연속 측정하여 저감율을 평가하였다. 측정결과, 제작된 판재형 활성탄의 비표면적은 약 $1,008m^2/g$으로 종래의 활성탄과 유사한 값을 보였으며, 휨 파괴 하중은 435 N으로 석고보드보다 3배 이상 높은 강도를 가지는 것을 알 수 있었다. 끝으로, 실내 라돈기체의 저감은 활성탄의 두께가 증가함에 따라 저감효율이 증가하였으며, 6 mm 두께의 활성탄 필터에서 90 % 이상의 우수한 라돈제거율을 보였다. 이러한 결과로부터 본 연구에서 제작된 판재형 활성탄은 밀폐된 실내에서 라돈 기체의 농도를 감소시키기 위한 친환경 건축 재료 및 공기 정화 필터로 활용이 가능할 것으로 기대된다.

공공위락 시설의 실내 공기환경에 관한 연구 (A Study on the Indoor Air Quality of Public Entertainment Facilities.)

  • 정재국
    • 한국주거학회논문집
    • /
    • 제9권1호
    • /
    • pp.143-152
    • /
    • 1998
  • This study aims to suggest ventilation design data for Public Entertainment Facilities in relation to Indoor Air Quality. The concentration of indoor air pollution such as CO, CO2, RH, Radon, HCHO, TSP was investigate, and the reguired ventilation rate of Public Rooms was calculated. As resuits of this study, the following conclusion could be obtained. Field measurement of P.E.F reveals that the concentration of CO2 was mist polluted and higher than IAQ standard, while that of other pollutats did not exceed the standard. In underground the concentration of CO2 increased 1130ppm(2 persons) 2170ppm(4 persons) 1970ppm(6 persons). The CO2 pollution was serions problem in underground more than second floor, in only exhaust ventilation system more than exhaust and supply system.

  • PDF

의료기관 지하시설의 라돈가스 측정과 내부피폭 조사 (Evaluation of Indoor Radon Levels in a Hospital Underground Space and Internal Exposure)

  • 송재호;진계환
    • 한국방사선학회논문지
    • /
    • 제5권5호
    • /
    • pp.231-235
    • /
    • 2011
  • 라돈($^{222}Rn$)은 지각의 암석이나 토양 또는 건축자재 중에 들어 있는 우라늄($^{238}U$)과 토륨($^{232}Th$)이 몇 단계의 방사성붕괴과정을 거친 후 생성되는 무색무취의 불활성기체로 광산이나 지하같이 밀폐된 공간에 잘 축적된다. 호흡기를 통하여 폐로 유입되고 라돈의 딸핵종이 폐나 기관지에 침적되어 폐암을 일으키는 원인이 된다. 사람의 생명을 다루는 의료기관에서의 라돈피폭은 평상시 방사선피폭량이 많은 방사선관계종사자와 면역력이 약한 환자에게 큰 위험이 될 수 있다는 판단에 이 실험을 실시하였다. 실험에 쓰인 계측기는 실시간 라돈측정기인 Professional Continuous Radon monitor이며 계측장소는 두 개의 병원 지하1층에서 지상2층까지 층별로 오전 10시부터 오후 3시까지 측정 하였다. Professional Continuous Radon monitor계측결과는 최소 14.8 Bq/$m^3$에서 최대 70.3 Bq/$m^3$로 국내기준치인 148 Bq/$m^3$이하로 나타났으며 유효선량은 최소 0.296 mSv에서 최대 1.406 mSv로 일년간 자연방사선으로부터 피폭되는 방사선량인 2.4 mSv의 10~58.3% 수준으로 나타났다.