• Title/Summary/Keyword: Radius Measurement

Search Result 297, Processing Time 0.023 seconds

A Study on the Validation of Effective Angle of Particle Deposition according to the Detection Efficiency of High-purity Germanium Gamma-ray Detector (고순도 저마늄 감마선 검출기의 검출효율에 따른 유효입체각 검증에 관한 연구)

  • Chang, Boseok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.487-494
    • /
    • 2020
  • The distance between the source and the detector, the diameter of the detector, and the volume effect of the radiation source result in a change in solid angle at the detector entrance, which affects the determination of detection efficiency by causing a difference in path length within the detector. A typical analysis method for calculating solid angles was useful only for a source (60Co) with a simple geometric structure, so in this experiment, the distance between the detector and the source was measured by switching on for up to 25 cm with the reference point of window cap 0.5 cm. In addition, 450 and 1000 ㎖ Marinelli beaker of standard volumetric sources were closely adhered to the detector. For circular point sources co-axial with the detector, the change in the solid angle to the distance from the detector window is equal to half the square radius of the source versus the square radius of the detector, if the resulting relationship of the calculation analysis results in the detector being less than the radius of the source. Since the solid angular difference is 0.5 the result of Monte Carlo is acceptable. The relationship between detector and source distance is shown. Solid angles have been verified to decrease rapidly with distance. Measurement and simulation results for a volumetric source show a difference of ±1.01% from a distance of 0 cm and less than 4 % when the distance is reduced to 5 and 10 cm. It can be seen that the longer distance, the smaller efficiency angle, and the exponential increase in attenuation as the energy decreases, is reflected in the calculation of efficiency. Thus, the detection efficiency has proved sufficient for the use of solid angle and Monte Carlo codes.

Path Loss Characteristics in Subway Tunnel at 2.65GHz (지하철 터널 환경에서 2.65GHz 대역신호의 경로손실 특성)

  • Jo, Han-Shin;Kim, Do-Youn;Yook, Jong-Gwan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.10A
    • /
    • pp.1014-1019
    • /
    • 2006
  • The research deals with the measurement of electromagnetic wave propagation in subway tunnels at 2.65GHz. Measurements have been conducted in 4 different types of tunnel courses, a straight tunnel, two curved tunnels, with 245m and 500m radius of curvature, and a tunnel that has both straight and curved sections. we found that the path loss exponent for the line-of-sight(LOS) region inside all the tunnels is $1.31{\sim}2.19$. The path loss exponents for LOS regions in the tunnel is lower than $(3{\sim}4)$, which corresponds to the path loss exponent factor for outdoor cellular environments. The path loss exponents of the straight tunnel, two curved tunnels with 245m and 500m radius of curvature are 1.94, 2.92, and 4.34, respectively. This indicates that a smaller radius of curvature in tunnel results in a higher path loss exponent for nonline-of-sight(NLOS) region. The path loss exponents for the NLOS region in the combined and curved tunnel, which have the same radii of cuvature, are 5.88 and 4.34, respectively. Therefore, it can be concluded that the path loss characteristics in tunnel environments are infulenced by the radii of curvature as well as the LOS distance.

A Biomechanical Comparative Analysis of the Multi-Radius Total Knee Arthroplastry System for Go up Stair and Go down Stair (계단 오르기와 내리기 동안 다축범위(multi-radius) 무릎인공관절 수술자의 운동역학적 비교분석)

  • Jin, Young-Wan;Yoo, Byung-In;Kawk, Yi-Sub
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.1
    • /
    • pp.31-41
    • /
    • 2006
  • The primary purpose of a TKA is to restore normal knee function Therefore, ideally, a TKA should: (a) maintain the natural leverage of the knee joint muscles to ensure generating adequate knee muscle moments to accomplish daily tasks such as rising from climbing stairs; (b) provide adequate knee joint stability. A 16-channel MyoResearch XP EMG system was used to collect the differential input surface electromyography signals VM, VL, RF, BF, ST during climbing/descending stair tests. A Peak Motion Measurement System was used to collect the kinematic and kinetic data. AKIN-COM Ill isokinetic dynamometer was used for EMG of VM, VL, RF, BF and ST during maximal voluntary contraction. I Quadriceps EMG results for the VM of the passed 1year group limb demonstrated significant less RMS EMG than that of the passed 3year group limb $60^{\circ}-15^{\circ}$ of knee flexion(p<0.05). The VL of the passed 1year group limb also demonstrated significants less RMS EMG than that of the passed 3year group limb from $60^{\circ}-45^{\circ}$ of knee flexion(p<0.05). Similar to the VM and VL, the RF of the passed 1year group limb showed less RMS EMG than that of the passed 3year group limb from $60^{\circ}-30^{\circ}$ do knee flexion(p<0.05). Hamstring EMG results for the BF of the passed 1year group limb demonstrated less RMS EMG than that of the passed 3year group limb from $75^{\circ}-15^{\circ}$ of knee flexion(p<0.05). The passed 1year group limb tended to have less ADD displacement(p<0.071) than that of the passed 3year group limb. There was no significant difference of the ABD displacement between the passed 1year group and the passed 3year group limbs(p<0.73). The passed 3year group used compensatory adaptation movement strategies to compensate for the strength deficit of passed 3year group limbs. The passed 3year group limb also increased the quadriceps muscle activation level to produce more knee extension moment to compensate for the short quadriceps moment arm. The passe 3year group limb might have an unstable knee joint in the medio-Iateral direction during the climbing/descending by showing a tendency of more ADD displacement and greater hamming co-activation EMG than the passed 1year group limbs. The TKA design was not able to help the knee joint to produce adequate knee extension moment with less quadriceps muscle effort. I think that old man needs continuous exercise for muscle strength.

THE RADIOGRAPHICAL MEASUREMENT OF ROOT CANAL CURVATURE OF MANDIBULAR PRIMARY 2ND MOLARS (하악 제 2 유구치 근관 만곡의 방사선학적 계측)

  • Kim, Young-Jong;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.4
    • /
    • pp.637-642
    • /
    • 2003
  • Morphology of primary root divergency and curvature determines the pattern of root resorption and periapical lesion, and affects successful root canal treatment. With the purpose of analysing the morphology of primary mandibular second molar roots and canals, the frequency, angle, radius, and start of curvature of the canal were measured. Fifty clinical radiographs were taken from $3{\sim}6$ years old children, followed by digitizing after scanning and analyzing by Scion image Beta 4.02TM(Scion Co. USA). The angle of curvature was determined by Schneider's method and the radius of curvature was determined by Schaefer's method. The results were as follows: 1. The angle of curvatures were $17.3^{\circ}{\pm}5.0$ (mesial), and $27.9^{\circ}{\pm}6.0$ (distal). Distal curvature was significantly larger than mesial.(p<0.05) 2. The radius of curvatures were $8.7mm{\pm}2.5$ (mesial), and $5.8\;mm{\pm}1.5$ (distal). Mesial curvature was significantly larger than distal.(p<0.05) 3. The start of curvatures were $4.1mm{\pm}0.6$ (mesial), and $4.2mm{\pm}0.6$ (distal). There were no difference between two groups. (P<0.05)

  • PDF

Development of the Fixed Slab Analogy Device for the Measurement of Stress Intensity Factor (응력확대계수 측정용 고정 슬랩상사 장치의 개발)

  • 정진석;최선호;황재석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.11
    • /
    • pp.1999-2010
    • /
    • 1992
  • The fixed slab analogy device which can measure stress intensity factors(S.I.F) experimentally by slab analogy theory is developed in this paper. The margin of errors resulted from the new testing apparatus are between 0.02% and 8.25%. Therefore, it is assured that this one can be effectively used for the more accurate measurement of S.I.F.( $k_{I}$, $k_{I I}$) than conventional apparatus. The pitch of master grating used in this experiment is 0.1mm It is known that the ratio of the distance from crack tip to the crack length on obtaining the accurate stress intensity factor is between 0.4 and 0.7. The optimum curvature radius of slab is about 125mm. The thickness of slab(plate) used in the fixed slab analogy device is 0.05mm(P.V.C. ; E = 64 MN/ $m^{2}$, .nu.=0.38), which is proved to be suitable for the test. The optimum material for the frame(slab`s external boundary) is a alloy tool steel(SKS 5) plate and its thickness is 1mm. In this research, the rigid cracks are directly bonded to the slab surface by cyanoacrylate adhesive for the easiness of slab making and conformity to the practical crack figure. The material of rigid crack is thin steel plate. It is expected that the developed method can be used effectively for the analysis of $k_{I}$ and $k_{I I}$ of arbitrary shaped or distributed cracks.cks.

Study on the Maintenance Cost of Railway Infrastructure Using Line Classification and TMV Data (선로등급 및 검측차 검측정보를 고려한 철도시설 유지보수비용 산정에 관한 연구)

  • Kim, In Kyum;Lee, Jun S.;Choi, Il Yoon;Lee, Hoo Seok
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.2
    • /
    • pp.275-287
    • /
    • 2017
  • During the feasibility study of new rail lines, maintenance cost of railway infrastructure has mostly been estimated based on the track length and on simplified parameters; however, the estimation reliability can be improved by employing the correction factor from UIC 715, as well as the line classification in UIC 714. The correlations between maintenance cost and various parameters such as weighted track length based on line classification, radius of curvature, gradient and worn -out rate have been analyzed according to the case studies. Prediction of the maintenance cost has been carried out using the cost data, which were representative of the whole cost data; as a result, it was demonstrated that a cost model based on the line classification and the correction factor was more reliable than the existing models. Furthermore, possibilities of using data from both the track measurement vehicle and from the maintenance information system, which are under development, have been investigated and, based on this investigation, a combined cost model using line classification, radius of curvature, gradient and worn-out rate, among other factors, will be proposed in the near future.

A Study on the Distribution of VOC Concentrations by Attachment Position of Air Samplers for Working Environment Measurement (작업환경측정 시료 채취기의 부착 위치에 따른 유기화합물의 농도 분포에 관한 연구)

  • Kwon, Yung-Gyu;Won, Jung Il;Jang, Hyung Seok;Sim, Sang-hyo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.3
    • /
    • pp.328-337
    • /
    • 2015
  • Objectives: The purpose of this study is to investigate differences in concentration according to the position at the left or right shoulder within a 30 cm of radius of workers' respirators and provide basic data for the establishment of an industrial health policy. Methods: Personal samples were collected from a total of 65 workers from 27 manufacturing firms in South Gyeongsang-do Province from November 5, 2011 to December 30, 2012 after classifying the laborers into left- and right-side groups. The organic compound samples were collected and analyzed in accordance with the NIOSH Manual of Analytical Methods (NMAM) 1501. Results: In terms of the concentration of organic compounds collected from both left and right shoulders at the position of workers' respirators, isobutyl acetate was the highest with 145 ppm at the left shoulder, followed by ethyl acetate (133.5 ppm) and toluene (38.13 ppm). At the right shoulder, on the contrary, ethyl acetate (149.3 ppm) was the highest, followed by toluene (46.26 ppm), xylene (29.63ppm) and isopropyl alcohol (28.06 ppm). Overall, the right shoulder was higher than the left shoulder in terms of concentrations. Conclusions: For the measurement of the working environment, workers' personal samples should be collected at the place closest to the respirator. In terms of the reduction of error, the attachment of two sample media is expected to reduce errors in exposure assessment.

Study on the Compatibility for an Ir-192 Source Manufactured by Korea Atomic Energy Research Institute (KAERI) in GammaMed Brachytherapy Machine (한국원자력연구소에서 개발한 Ir-192 선원의 감마메드 치료기 호환성 연구)

  • Jeong, Dong-Hyeok;Lee, Kang-Kyoo;Kim, Soo-Kon;Moon, Sun-Rock
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.78-85
    • /
    • 2010
  • The compatibility with GammaMed-12i brachytherapy machine for an Ir-192 encapsulated source (IRRS20, KAERI, Korea) manufactured by Korea atomic energy research institute (KAERI) has been investigated. As a mechanical testing of compatibility, precise measurement of step movement with channels, measurement of curvature of radius for wire, and emergency return testing were performed. Periodic measurements of air kerma strength for 45 days were carried out to evaluate decay characteristics of Ir-192 radioisotope and comparison of dose distributions in phantom between KAERI and old sources previously used were performed by film dosimetry. KAERI source has a good compatibility with GammaMed12i machine as a result of mechanical testing. There are in good agreement with calculated values in activity characteristics and there were small differences in dose distributions around the source in comparison between KAERI and old source.

An Experimental Study on the Propagated Uncertainties on the Total-to-total Efficiency of an Axial Turbine (축류형터빈 전효율에 파급된 불확도에 관한 실험적연구)

  • 조수용;김은종
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.123-126
    • /
    • 2003
  • The uncertainties generated by measurement parameters are propagated to the uncertainty of total-to-total efficiency on an experiment. The effect of uncertainties’ propagation are analyzed through a turbine performance test. A tested 3-D axial type turbine has a 0.373 degree of reaction at the mean radius and the performance test is conducted at the low pressure and cold temperature status. The uncertainty of turbine inlet and exit total pressure shows the strong propagation effect to the uncertainty of total-to-total efficiency. This means that a high precision pressure measuring system is required to reduce the uncertainty propagated by the pressure. In the uncertainty portion of each measurement parameters to the uncertainty of total-to-total efficiency, the uncertainty by torque is the highest and the uncertainty by RPM is the lowest. In case of the total pressure, the effect of the uncertainty by torque is increased with the increasing RPM. The uncertainty of total pressure at the turbine exit shows more influence to the results than that at the turbine.

  • PDF

Measurement of Micro-displacement of an Object by Laser Speckle using Linear Array CCD Detection System (레이저 스펙클과 1차원 CCD소자를 이용한 물체의 미소변위측정에 관한 연구)

  • 우창헌;민동현;김수용
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.1
    • /
    • pp.138-143
    • /
    • 1994
  • A speckle correlation method was applied to measure the in-plane translation of a diffuse object which has rough surface using a linear CCD sensor and personal computer. Displacement of a speckle pattern produced from the object illuminated by a laser beam was measured by the cross-correlation functions between the I-D speckle profiles before and after the object translation, which were measured by linear CCD array sensor to be sent to IBM 386 personal computer. The sensitivity of the measurement was dependent on the radius of the wavefront curvature of incident beam as well as the spatial resolution of linear CCD array. A linear CCD array had 15 Jlffi pitch and 1728 pixels. The ratio of the speckle displacement and object translation varied from 1.03 to 5.20. The object translation of $3\mu\textrm{m}$ can be measured br the linear CCD sensor of which pitch was $15\mu\textrm{m}$, when the ratio of the speckle displacement and object translation was 5.20.s 5.20.

  • PDF