• Title/Summary/Keyword: Radiopacity

Search Result 105, Processing Time 0.026 seconds

A Radiographic study of Fibro-osseous lesions of the jaw bones (악골 섬유성 골병소의 방사선학적 연구)

  • Kwon Kyung-Yun;Choi Karp-Shik
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.1
    • /
    • pp.27-36
    • /
    • 1998
  • The purpose of this study was to obtain information on the clinical and radiographic features of the fibro-osseous lesions in the jaws. For this study, the author examined and analysed the clinical records and radiographs of 71 cases of 68 patients in fibrous dysplasia, 35 cases of ossifying fibroma and 30 cases of 16 patients of periapical cemental dysplasia diagnosed by clinical and radiographic or histopathological examinations. The obtained results were as followings: L Fibrous dysplasia occurred most frequently in the 2nd decade (30.0%), ossifying fibroma in the 3rd-4th decades, periapical cemental dysplasia in the 4th decade, and all of three lesions showed slight predilection in females. In most cases, chief complaints were painless facial swelling in fibrous dysplasia and ossifying fibroma, and periapical cemental dysplasia was found accidentally in radiographs. 2. Fibrous dysplasia was occurred more frequently in maxilla, ossifying fibroma in mandible and both lesions in premolar-molar area. Periapical cemental dysplasia was occurred most frequently in the mandibular anterior area. The size of fibrous dysplasia was larger than that of ossifying fibroma, and the shape of ossifying fibroma was more round and elliptical than fibrous dysplasia whose was fusiform. 3. Fibrous dysplasia was shown homogeneous radiopaque shadow of 57.6% and ossifying fibroma & periapical cemental dysplasia were shown mixed appearance of radiolucency and radiopacity shadows at 74.2%, 60.0%, respectively. 4. Fibrous dysplasia was entirely shown poorly defined at 87.7%, but ossifying fibroma & periapical cemental dysplasia were shown well outlined at 60.0%, 70.0%, respectively. 5. Cortical thinning and expansion were observed in fibrous dysplasia and ossifying fibroma, and severe in ossifying fibroma than fibrous dysplasia, and those signs were not seen in periapical cemental dysplasia. Loss of lamina dura was dominant in fibrous dysplasia and root resorption was dominant in ossifying fibroma. Displacement of mandibular canal and the degree of the increase of vertical dimension were alike in both lesions. Displacement of maxillary sinus or nasal cavity, thinning & expansion of the maxillary sinus were dominant in fibrous dysplasia. 6. Polyostotic fibrous dysplasia was occurred at 5.9%, Multiple periapical cemental dysplasia at 43.7%. Occurrence rate in the edentulous area of fibrous dysplasia and ossifying fibroma were 7.0%, 8.6%, respectively.

  • PDF

RADIOPACITY OF CAD/CAM CERAMICS (CAD/CAM용 도재의 방사선 불투과성에 관한 연구)

  • Lee, Jong-Hyeok;Choi, Han-Seuk;Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.357-365
    • /
    • 1998
  • 목적: 치과용 수복재료의 방사선 불투과성은 매우 다양하다. 따라서 다양한 수복재료의 방사선 불투과성을 인지하여 치질과 비교하면 이차우식의 진단에 도움이 될 수 있다. 도재의 방사선 불투과성에 따라 적절한 luting cement의 선택이 가농해진다. 수복재료의 방사선 불투과성은 알루미늄 step wedge 의 후경과 방사선 불투과성과의 상관관계 의해 측정된다. 본 연구의 목적은 CAD/CAM용 도재와 이틀의 접착에 쓰이는 접착재료의 방사선 불투과성을 조사해 적절한 재료의 선택과 이차우식 진단의 효율결정에 도움이 되게 하는데 있다. 방법: 본 실험에서는 CAD/CAM용 도재인 Vita MarkII, Dicor MGC와 이의 접착에 사용되는 Z-100, 그리고 luting cement인 Duo cement, Scotchbond resin cement를 사용해 방사선 불투과성을 측정하였다. 시편 제작을 위해 도재를 저속절단기로 두께 2mm, 3mm로 절단하였으며 Z-100과 cement시편은 두께 2mm와 3mm, 직경 7.0mm의 금속 주형을 제작한 후 재료를 양쪽 면에 유리판을 대고 조임쇠로 압접하였으며 광조사기를 사용하여 각 재료마다 두 가지 두께로 10개씩 100개의 시편을 제작하였다. 치질의 시편을 얻기 위해 교정 목적으로 최근에 발거된 정상적인 상악 소구치를 저속 절단기를 사용하여 협설측 교두정을 기준 삼아 2mm, 3mm 두께로 절단하였으며 방사선 불투과성의 기준을 위해 12개의 step으로 구성된 12mm두께의 aluminum step wedge를 사용하였다. Kodak E-Speed occlusal film에 aluminum step wedge와 시편들을 위치시킨 후 70kVp, 7mA, 2.16mm aluminum filtration으로 고정된 dental X-ray unit을 사용하여 target과 film 사이의 거리는 25cm, 노출시간은 0.2초로 하여 방사선 촬영을 한 다음, 현상된 방사선 사진상에 나타난 방사선 불투과성을 X-rite 301 densitometer를 이용하여 측정한 값들의 평균을 냈다. 얻어진 결과는 one-way ANOVA Duncan test(P<0.01)로 검증하였다. 결론: 1. Dicor MGC의 방사선 불투과성은 법랑질보다 약간 높게 나타났다.(P<0.01) 2. Vita Mark Il는 상아질보다 낮은 방사선 불투과성을 보였다.(P<0.01) 3. Z-100과 Luting cement들의 방사선 불투과성은 법랑질보다 높았다. Duo cement가 방사선 불투과성이 가장 높았고 그 다음이 Z-100, 그리고 Scotchbond resin cement 순이었다. 4. Z-100과 2종류의 방사선 불투과성 luting cement들은 Vita Mark II 와 같이 사용하면 2차우식 진단에 도움이 된다.

  • PDF

Efficiency Evaluation of CT Simulator QA Phantom (전산화 단층촬영 모의치료기 정도관리 팬텀의 유용성 평가)

  • Hwang, Se-Ha;Min, Je-Sun;Lee, Jae-Hee;Park, Heung-Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.89-95
    • /
    • 2009
  • Purpose: The purpose is to evaluate efficiency of the CT simulator QA phantom manufactured for daily QA. Materials and Methods: We made holes ($1{\times}100{\times}1\;mm$) to verify accuracy between image and real measurement in polystyrene phantom and made 1 mm holes to verify table movement accuracy at superior and inferior 100 mm to the center of the phantom and inserted radiopacity material. To evaluate laser alignment, we made cross mark on the right and left side at phantom and to evaluate CT number accuracy we made 3 cylindrical holes and inserted equivalence material of bone, water, air in them. After CT scanning the phantom, We evaluated accuracy between image and real measurement, accuracy of table movement, laser, and CT number using exposed image. Results: It was measured that the accuracy between image and real measurement was ${\pm}0.3\;mm$, table movement accuracy was ${\pm}0.3\;mm$, laser accuracy was ${\pm}0.5\;mm$ from 7th January to 7th March in 2008 as within the reference point ${\pm}1\;mm$. In the CT number accuracy of bone was ${\pm}10\;HU$, air was ${\pm}5\;HU$, water was ${\pm}5\;HU$ as within the reference point is ${\pm}10\;HU$. Conclusion: We was able to perform CT simulator QA and laser equipment QA more conveniently and fast using manufactured phantom at the same time. We will be able to make more accurate treatment plan that added to QA procedures using images at previous daily QA.

  • PDF

Total Ear Canal Ablation and Lateral Bulla Osteotomy for Chronic Otitis Externa and Media in Dogs: Postoperative Recovery and Long-Term Follow-up (개에서 만성외이염과 중이염에 대한 전이도 적출술과 외측 고포절골술: 수술 후 회복과정과 장기간 예후)

  • Kim, Joon-Young;Jeong, Soon-Wuk;Jeong, Man-Bok;Han, Hyun-Jung;Kim, Je-Sun
    • Journal of Veterinary Clinics
    • /
    • v.20 no.1
    • /
    • pp.26-32
    • /
    • 2003
  • The clinical results of 10 consecutive total ear canal ablation combined with lateral bulla osteotomy (TECA-LBO) in six dogs with chronic otitis externa and media were evaluated by the postoperative recovery and long-term follow-up. All dogs were selected for TECA-LBO on the basis of following five clinical symptoms. First, medical treatment couldnt improve clinical signs at least for eve. 2 months. Second, tympanic membrane was completely disappeared. Third, radiopacity was increased in tympanic cavity. Forth, petrous temporal bone was sclerosed. Fifth, ear canal calcification was progressed. And all cases were satisfied all five clinical symptoms. At 14. days after operation, the preoperative symptoms of chronic otitis externa and media which were scratching ear, pain, and hardening ear canal were resolved, and postoperative swelling, erythema, head tilt, and exudate from Penrose drainage were not existed In all cases. Loss of eye blink was happened in 4 cases, but these were disappeared between 14 days a(ter operation except one case on 3 months. All dogs were discharged form hospital at 14 days after operation. Between 3.5 and 6.5 months after discharging from hospital, para-aural abscessation was happened only in all Cocker spaniels. But this complication was solved by ventral bulla osteotomy (VBO). The dogs which didn't show para-aural abscessation after TECA-LBO didn't show scratching, pain, hardening of ear and hearing ability was improved, at 7.5 months after TECA-LBO. And the dogs which showed para-aural abscessation after TECA-LBO also didn't show scratching, pain, hardening of ear and hearing ability was also improved, at 7.5 months after VBO. In conclusion, After TECA-LBO, all dogs were recovered well without complication within 2 weeks except Cocker spaniel. And loss of eye blink can be cured naturally within 2 weeks after surgery. And para-aural abscessation can be happened between 4 and 7 months after TECA-LBO, so surgeon must follow-up until 8 months.

Effects of Gadolinium Contrast agent on Bone Mineral Density Measurement using Dual Energy X-ray Absorptiometry (가돌리늄조영제가 이중에너지 X-선 흡수법을 이용한 골밀도검사에 미치는 영향)

  • Lee, Keun-Ohk;Lee, Min-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.63-70
    • /
    • 2021
  • Radiographic contrast agents are used for diagnostic purposes and are one of the factors affecting measured values in bone density tests. They are absorbed into tissues and have an effect of increasing the measured values of bone density, so they are avoided as much as possible before performing a bone density test. MRI contrast agents, which have different physical properties and mechanisms of action than radiographic contrast agents, are based on gadolinium, a metal element. They have radiopacity characteristics, so MRI are generally performed prior to examination using radiation. The purpose of this study was to investigate the effects of MRI contrast agents on bone mineral density examination using dual energy X-ray absorption. Two types of gadolinium based MRI contrast agents were injected into an acrylic water tank for each volume, and the humanoid spine phantom was inserted and the BMD and T-score from (L1-L4) were analyzed by scanning a total of 30 times, 5 times for each injection type. The average value of the measured total (L1-L4) bone density for each of the two contrast agents was 0.952±0.052, 0.957±0.050, and 0.956±0.05g/㎠, respectively, for the Gadoterate Meglumine component 0mL, 7.5mL and 15mL, when the gadobutrol components were 0mL, 5mL, and 10mL, there was no statistically significant difference at all sites at 0.953±0.001, 0.954±0.001, and 0.945±0.001g/㎠, respectively(p>0.05). The average value of total T-score was -0.46±0.05, -0.4±0, -0.42±0.04 when the Gadoterate Meglumine component was 0mL, 7.5mL and 15mL, respectively. When the Gadobutrol ingredients were 0mL, 5mL and 10mL, there was no statistically significant difference in all areas, with -0.46±0.05, -0.46±0.05, and 0.5±0.00, respectively. In this experiment, the MRI contrast agent was found to have no effect on bone density tests, using the dual-energy X-ray absorption method. There is a limitation in that physical conditions such as kidney and health conditions etc. were not taken into consideration, so further clinical research is expected to be conducted in the future.