• Title/Summary/Keyword: Radionuclide Scan

Search Result 58, Processing Time 0.021 seconds

Nuclear Medicine Imaging Diagnosis in Infectious Bone Diseases (감염성 골질환의 핵의학 영상진단)

  • Choi, Yun-Young
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.4
    • /
    • pp.193-199
    • /
    • 2006
  • Infectious and inflammatory bone diseases include a wide range of disease process, depending on the patient's age, location of infection, various causative organisms, duration from symtom onset, accompanied fracture or prior surgery, prosthesis insertion, and underlying systemic disease such as diabetes, etc. Bone infection may induce massive destruction of bones and joints, results in functional reduction and disability. The key to successful management is early diagnosis and proper treatment. Various radionuclide imaging methods including three phase bone scan, Ga-67 scan, WBC scan, and combined imaging techniques such as bone/Ga-67 scan, WBC/bone marrow scan add complementary role to the radiologic imaging modalities including plain radiography, CT and MRI. F-18 FDG PET imaging also has recently been introduced in diagnosis of infected prosthesis and chronic active osteomyelitis. Selection of proper nuclear medicine imaging method will improve the diagnostic accuracy of infections and inflammatory bone diseases, based on understading of pathogenesis and radiologic imaging findings.

Detection of Orthopedic Disease Using Three Phase Radionuclide Bone Scan in the Dog (개에서 3단계 골스캔을 이용한 골병변의 진단)

  • 강성수;최석화
    • Journal of Veterinary Clinics
    • /
    • v.19 no.1
    • /
    • pp.103-106
    • /
    • 2002
  • Specific diagnosis of orthopedic disease can be diffcult in canine practice. Failure to detect the clinical signs of a disorder during physical examination of dogs with acute or chronic lameness is the most common reason for failure to make specific diagnosis. A 6-month-old, female doberman with history of swelling and non-weight-bearing lameness in the left forelimb was referred to Beterinary Teaching Hospital of Chungbuk National University. Physical examination, plain radiography, and conventional three-phase radionuclide bone scan were performed in the patient. Based on the physical exam and radiography, this case was diagnosed as elbow strain and subluxation. Conventional three-phase bone scan detected soft tissue inflammation and osteochondral lesions of elbow joint, and revealed good agreement with clinical findings. Therefore, conventional three-phase bone scan was able to provide the precise information about inflammation of soft tissue and osteochondral lesions of joint.

TECHNETIUM-99m BONE SCAN FOR EVALUATING AUTOLOGOUS ILIAC BONE GRAFT AND FREEZE-DRIED BONE ALLOGRAFT IN DOG'S MANDIBLE (Technetium-99m 골주사를 이용한 하악골의 자가골 및 동종골 이식의 평가에 대한 실험적 연구)

  • Jin, Sung-Bark;Kim, Soo-Kyung
    • The Journal of the Korean dental association
    • /
    • v.22 no.1 s.176
    • /
    • pp.37-48
    • /
    • 1984
  • Clinical assessment of bone-graft healing in the maxillofacial region is generally limited to clinical evaluation, radiographs, and biopsy. Sequential interpretation of osseous repair, more sensitive than with conventional radiography is possible with a non-invasive, non-destructive radionuclide method. Technetium-99m radionuclide bone scan was used in the evaluation of the progress of osteogenic activity in autologous iliac bone graft and freeze-dried bone allograft of dog's mandible. Bone scan was performed at 1wk, 2wk, 4wk, 6wk, and 8wk after grafting. In autologous graft the activity ratio for the graft bone remained greater than that of the host since 2자 after grafting; however, in lyophilized allograft the activity ratio for graft bone was greater than that of the host at 6자 after grafting.

  • PDF

Two Cases of Bone Scan in Snake Bite (골주사를 이용한 사교상(Snake bite) 환자의 경과 관찰 2예 보고)

  • Park, Jeong-Kook;Lee, Hwang-Bock;Cha, Soon-Joo;Lee, Min-Jae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.19 no.2
    • /
    • pp.105-107
    • /
    • 1985
  • It is very difficult to check the severity and clinical course of the toxicity in snake bite patients by virtes of clinical manifestation and laboratory tests. And we observed the. findings of bone scan with 99mTc-MDP in two snake bite patients. First patient was bitten in the right ankle with local pain and swelling. The finding of bone scan of him was increased uptake of radionuclide in the soft tissue of right leg and thigh. Others were normal findings. Second patient was bitten in the right hand. But his symptom was severe and he complained local pain and swelling, nausea, blurred vision, and oliguria. The bone scan findings of second patient was; Increased uptake of radionuclide in the soft tissue of whole body. Decreased uptake in the bone tissue. Renal outline was not delineated. Follow up study 10 days after, revealed more improved findings in the scan.

  • PDF

Clinical Study of Ventricular Function Following Open Heart Surgery by Radionuclide Angiocardiogram - left ventricular ejection fraction by ECG gated blood pool scan - (방사성 동위원소를 이용한 개심술 전후의 심실기능 변화에 관한 연구: ECG gated blood pool scan을 이용한 ejection fraction 검사)

  • Lee, Jeong-Cheol;Kim, Gyu-Tae
    • Journal of Chest Surgery
    • /
    • v.19 no.1
    • /
    • pp.25-34
    • /
    • 1986
  • Recently, radionuclide angiocardiogram is one of the most common procedure for assessment of ventricular performance due to its distinctive advantages such as safety, accuracy, and ease of repeated studies. Also, measurement and comparison between pre and postoperative left ventricular ejection fraction [LVEF] are meaningful for assessing the severity of myocardial damage which occurred during open heart surgery and the status of myocardial recovery. We obtained pre and post operative LVEF using radionuclide angiocardiogram on 30 patients composed of atrial septal defect, ventricular septal defect, cyanotic congenital heart disease, and valvular heart disease who undergone the open heart surgery from March to august 1984. The study revealed that ventricular septal defect and mitral valvular heart disease showed 8.1% and 6.2% decreases of postoperative LVEF, respectively. But, there are little increases of postoperative LVEF in the atrial septal defect and cyanotic congenital heart disease. In ventricular septal defect, each group of Qp/Qs over 2.0 and systolic pulmonary artery pressure over 50mmHg showed significant 17% and 14.7% decreases of postoperative LVEF, respectively. Considering the duration of the aortic cross clamping times and closing methods of VSD, each group of duration over 30 min. and of patch closure showed 13.9% and 14.2% decreases of LVEF between pre and postoperative status respectively which was significant finding statistically.

  • PDF

The Evaluation of Difference according to Image Scan Duration in PET Scan using Short Half-Lived Radionuclide (단 반감기 핵종을 이용한 PET 검사 시 영상 획득 시간에 따른 정량성 평가)

  • Hong, Gun-Chul;Cha, Eun-Sun;Kwak, In-Suk;Lee, Hyuk;Park, Hoon;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.102-107
    • /
    • 2012
  • Purpose : Because of the rapid physical decay of the short half-lived radionuclide, counting of event for image is very limited. In this reason, long scan duration is applied for more accurate quantitative analysis in the relatively low sensitive examination. The aim of this study was to evaluate the difference according to scan duration and investigate the resonable scan duration using the radionuclide of 11C and 18F in PET scan. Materials and Methods : 1994-NEMA Phantom was filled with 11C of $30.08{\pm}4.22MBq$ and 18F of $40.08{\pm}8.29MBq$ diluted with distilled water. Dynamic images were acquired 20frames/1minute and static image was acquired for 20minutes with 11C. And dynamic images were acquired 20frames/2.5minutes and static image was acquired for 50minutes with 18F. All of data were applied with same reconstruction method and time decay correction. Region of interest (ROI) was set on the image, maximum radioactivity concentration (maxRC, kBq/mL) was compared. We compared maxRC with acquired dynamic image which was summed one bye one to increase the total scan duration. Results : maxRC over time of 11C was $3.85{\pm}0.45{\sim}5.15{\pm}0.50kBq/mL$ in dynamic image, and static image was $2.15{\pm}0.26kBq/mL$. In case of 18F, the maxRC was $9.09{\pm}0.42{\sim}9.48{\pm}0.31kBq/mL$ in dynamic image and $7.24{\pm}0.14kBq/mL$ in static. In summed image of 11C, as total scan duration was increased to 5, 10, 15, 20minutes, the maxRC were $2.47{\pm}0.4$, $2.22{\pm}0.37$, $2.08{\pm}0.42$, $1.95{\pm}0.55kBq/mL$ respectively. In case of 18F, the total scan duration was increased to 12.5, 25, 37.5, and 50minutes, the maxRC were $7.89{\pm}0.27$, $7.61{\pm}0.23$, $7.36{\pm}0.21$, $7.31{\pm}0.23kBq/mL$. Conclusion : As elapsed time was increased after completion of injection, the maxRC was increased by 33% and 4% in dynamic study of 11C and 18F respectively. Also the total scan duration was increased, the maxRC was reduced by 50% and 20% in summed image of 11C and 18F respectively. The percentage difference of each result is more larger in study using relatively shorter half-lived radionuclide. It appears that the accuracy of decay correction declined not only increment of scan duration but also increment of elapsed time from a starting point of acquisition. In study using 18F, there was no big difference so it's not necessary to consider error of quantitative evaluation according to elapsed time. It's recommended to apply additional decay correction method considering decay correction the error concerning elapsed time or to set the scan duration of static image less than 5minutes corresponding 25% of half life in study using shorter half-lived radionuclide as 11C.

  • PDF

Comparison of functional Images obtained by radionuclide angiocardiography and gated blood pool scan (방사성핵종 심혈관조영술의 기능적영상화에 대한 고찰)

  • Bom, Hee-Seung;Kim, Ji-Yeul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.2
    • /
    • pp.186-191
    • /
    • 1991
  • Radionuclide cardiac studies lend themselves exceptionally well to functional imaging. This is especially true for gated blood pool scan (GBP). Making functional images is also possible in radionuclide angiocardiography (RNAC). In this study we tried to validate the functional images obtained from RNAC by comparing it with GBP. Twenty three patients (16 patients with coronary artery diseases, 5 with hypertensive heart diseases, and 2 with nonspecific chest pains) underwent simultaneous RNAC and GBP at the same position (LAO $45^{\circ}$). From both studies, global ejection fraction, regional ejection fraction, phase image, amplitude image, stroke image, paradox image, maximum ejection and maximum filling rates were obtained. Global ejection fraction are almost same in both studies. Regional ejection fractions of apex and inferior portion of left ventricle calculated from RNAC are well correlated with those of GBP. Phase and paradox image, maximum ejection and maximum filling rates were obtained. Global ejection fraction are almost same in both studies. Regional ejection fractions of apex and inferior portion of left ventricle calculated from RNAC are well correlated with those of GBP. Phase and paradox images of RNAC are very similar to those of GBP. However, amplitude and stroke images are different. Regional ejection fractions of the left ventricular base, maximum ejection and maximum filling rates obtained from RNAC are significantly different from those of GBP. In conclusion, albeit all of functional images of RNAC is not same as GBP, regional walt motions and global left ventricular function are expected to be successfully analyzed by phase and paradox image and ejection fraction.

  • PDF

A Study on the Thyroid Scan Images by Different Radionuclides ($^{99m}Tc$ pertechnetate and $^{131}I$) and Multiple Views (사용핵종(使用核種) 및 주사방향(走査方向)에 따른 갑상선주사상(甲狀腺走査像)의 차이(差異)에 관한 연구(硏究))

  • Whang, Il-Yong;Chung, Soon-Il;Kim, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.20 no.1
    • /
    • pp.53-58
    • /
    • 1986
  • Thyroid scans using $Na^{131}I\;and\;^{99m}TcO_4^-$ in two (anterior and anterior oblique) projections were done simultaneously in 50 patients with single palpable nodule and in euthyroid state(nodular nontoxic goiter) and 20 normal subjects to evaluate the imaging ability of each radionuclide and the necessity of oblique view. In detection of a nodule as a cold or cool area, $^{99m}TcO_4^-$ was slightly superior to $^{131}I$(82 % to 78% with anterior view alone, 92% to 84% when oblique view is added in detectability), with addition of an oblique view, 5 more cold or cool area in $^{99m}Tc$ scan and 3 more $^{131}I$ scan were detected. In normal subjects $^{99m}TcO_4^-$ scan was significantly superior to $^{131}I$ scan(90% to 70%) in getting normal pattern of tracer uptake in the glands. For routine imaging study of the thyroid, $^{99m}Tc$ pertechnetate scan with multiple projection is considered to be a preferable method.

  • PDF

Comparison of Radionuclide Bone and Gallium Scans in the Therapeutic Evaluation of Bone Lymphoma (골임파종의 치료효과판정을 위한 핵의학적 골스캔과 갈륨스캔의 비교)

  • Moon Tae-Yong;Hwang, In-Tae;Kim, E. Edmund
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.3
    • /
    • pp.377-383
    • /
    • 1994
  • Objective : We retrospectively analysed $^{99m}Tc$-MDP bone and $^{67}Ga$ scans to evaluate therapeutic response of bone lymphoma among patients with complete remission. Subjects and Methods : We reviewed 35 cases with an increased uptake finding $^{99m}Tc$-MDP bone scans and 16 $^{67}Ga$ scans that were follow-up studies during and after therapy. The $^{99m}Tc$-MDP bone and $^{67}Ga$ scans were graded visually from 1 to 4 in which grade 3 means same uptake density as that of normal sacroiliac articulation in bone scan and normal liver in $^{67}Ga$ scan, respectively. Results: The improvement findings during and after therapy were found in 66.0% (19/ 29) and 72.7% (24/33) with $^{99m}Tc$-MDP bone scan, 84.6% (l1/13) and 86.7% (13/15) with $^{67}Ga$ scan, respectively. The mean grades of the uptake density in $^{99m}Tc$-MDP bone scan were 3.06 before, 2.34 during, 1.75 after therapy. Those in the $^{67}Ga$ scan were 3.22 before, 1.42 during 1.30 after therapy. Conclusion. $^{67}Ga$ scans appeared more sensitive than bone scans in evaluating therapeutic response of bone lymphoma.

  • PDF