• Title/Summary/Keyword: Radiology service

Search Result 158, Processing Time 0.024 seconds

A Study on the Effects of the Service Quality of the Radiology Department on The Medical Customer Satisfaction (영상의학과 서비스 품질이 의료소비자 만족에 미치는 영향)

  • Yeo, Jin-Dong;Park, Jung-Hoon
    • The Korean Journal of Health Service Management
    • /
    • v.4 no.1
    • /
    • pp.59-70
    • /
    • 2010
  • The purpose of this study is to examine how much the service quality of the radiology department at the hospital is influential to customers' satisfaction and intents of reusing the department and informing it to others. For the purpose, this researcher surveyed 201 patients whon used the radiology department at the hospital. Findings of the study can be summarized as follows. First, the surveyed patients' perceptions of the service quality of the radiology department in accordance with their demographic characteristics were investigated to find that among the subjects, women were perceiving the radiological technician as more kind than men were. Among the subjects, women were higher in customer satisfaction about the service quality of the radiology department and intents of reusing the department and informing it to others than men were. Second, out of factors of the radiology department's service quality, those who were significantly affecting customer satisfaction included waiting time for treatment at the department, kindness of the radiological technician, environment of the radiography room and facilities of the department. Third, customer satisfaction was significantly affecting the intent of reuse. Fourth, customer satisfaction was significantly influencing the intent of informing to others. In other words, the more customers are satisfied with the service quality of the radiology department, the more they are likely to inform the department to others and reuse it. In conclusion, the sustainable growth and effective management of the medical institution requires improving the service quality of its department of radiology and thereon maximizing customer satisfaction.

Lens Dose Reduction Methods and Image Quality in Orbital Computed Tomography Scan (안와 전산화단층촬영검사 시 수정체 선량감소 방법과 영상 평가)

  • Moon, Se-Young;Hong, Sang-Woo;Seo, Ji-Sook;Kim, Yeong-Beom;Kwak, Wan-Sin;Lee, Seong-Yeong;Kim, Jung-Soo
    • Journal of radiological science and technology
    • /
    • v.43 no.5
    • /
    • pp.343-351
    • /
    • 2020
  • This study analyzed dose reduction and quality of images through dose reduction tools and shielding board to protect sensitive eye lens in radiation during orbit CT examinations for clinical data use. During CT scans of the phantom, surface dose (CT scanner dosimetry phantom, ion chamber-3 times) and quality of image (radiosurgery head phantom, visual assessment-2 times, HU standard deviation) were evaluated using X-care which is dose reduction tools and bismuth shielding board. The results of experiments of eight conditions showed a relatively reduced dose in all other conditions compared to when no conditions were set. In particular, the area corresponding to the ophthalmic part reduced the surface dose by up to 45.7 %. The visual evaluation of images by specialists and the quality evaluation of images analyzed by HU standard deviation were clinically closest to the use of X-care and shielding board (1 cm in height). Therefore, it is believed that the use of shielding board in a suitable location with dose reduction tools while investigating the optimal radiation dose will reduce the exposure dose of sensitive lens at radiation while maintaining the quality of the images with high diagnostic value.

A Study on Ways of Improving Radiology Department Services (영상의학과 서비스 개선방안에 관한 연구)

  • Yeo, Jin-Dong;Kim, Hye-Sook
    • The Korean Journal of Health Service Management
    • /
    • v.3 no.1
    • /
    • pp.5-13
    • /
    • 2009
  • The purpose of this study is to find ways of improving radiology services provided at hospitals through examining current problems of the services and measuring patient satisfaction about them For the purpose, this researcher made a questionnaire survey of 209 patients who used the radiology departments of two university hospitals as tertiary medical institutions located in Busan. The survey was carried out from June 1 to July 30, 2008. Results of the study can be summarized as follows. The patients' satisfaction about the kindness of radiologists was generally low since it Was measured to be scored 3.0 or below in average. This indicates that they were dissatisfied with the equipment and environment. The patients' anxiety about the process of radiology was measured and scored 3.0 or below in average, indicating they generally felt anxious about the process. Factors affecting the above reliability such as their skillfulness, qualification, persuasiveness and expertise were found positively correlated with the patients' satisfaction about the radiologists. To realize Better radiological department services, in conclusion, radiologists are required to resort to conventional practices of radiology no longer, and reconsider current radiological technologies. They are also required to firmly establish their pride as a professional, and make best efforts to keep pace with this era of rapid scientific development by constantly training themselves.

  • PDF

CD Copy Service to Enhance Customer Satisfaction Through Improved Flow Study - Based on QI Use - (CD Copy업무 flow개선을 통한 고객만족도 향상에 관한 연구 - QI 활용을 중심으로 -)

  • Choi, Sung-Hyun;Hwang, Sun-Kwang;Lee, Jong-Woong;Dong, Kyung-Rae;Kweon, Dae-Cheol;Goo, Eun-Hoe;Park, Chang-Hee
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.3
    • /
    • pp.127-132
    • /
    • 2011
  • This is to improve the complicate process of the existing CD copy flow in Department of Radiology. It is also to improve the medical service of the hospital to secure private information of patients. Survey: The patients who ask for CD copies in the Department of Radiology of this hospital(for 6 months in 2010). Time: Comparing the total amount of time of the previous and the modified CD copy flow. Using the SPSS 12.0 program for testing significance of independent two-samples t-test. Private information: Introducing the identification-system based on the medical law to supplement the security of personal information of patients. There was manifold complaints due to receipt and issuing the prescription in Admission and Discharging office and outpatient department. The time has been approximately 50% reduced from 70 mistunes to 32 mistunes due to simplifying the routes. The security of the personal information has been supplemented by let patients submit documentary evidence based on the medical law. The service in the hospital has been improved as a result of simplifying the whole process of the routes and receipt process. Therefore, the each stage of waiting time has been decreased. In addition, the personal information of the patients has been more secured.

  • PDF

Tumor Recurrence in Hepatocellular Carcinoma Patients after Radiofrequency Ablation: Portal Hypertension as an Indicator of Recurrence of Hepatocellular Carcinoma (간세포암 환자의 고주파열치료 후 종양 재발: 예후인자로서 문맥고혈압)

  • Jang, Seong Won;Cho, Yun Ku;Kim, Ju Won;Gil, Je Ryung;Kim, Mi Young;Lee, Young
    • Journal of the Korean Society of Radiology
    • /
    • v.79 no.5
    • /
    • pp.264-270
    • /
    • 2018
  • Purpose: To evaluate the effect of portal hypertension on the tumor recurrence in patients with hepatocellular carcinoma (HCC) and without hepatic decompression following radiofrequency ablation (RFA). Materials and Methods: Treatment-naïve HCC patients within the Milan criteria and with Child-Pugh class A were included in this study, who had performed RFA in our hospital between January 2010 and March 2017. Univariate and multivariate analyses using the Cox proportional hazard model were performed to find the predictors of local or distant tumor recurrence. Results: Overall, 178 patients were included in this study. Median follow-up period was 40.2 months. The difference in the local tumor progression rates depending on the absence or presence of portal hypertension was not statistically significant (p = 0.195). The 1-, 3-, and 5-year distant intrahepatic tumor spread rates were 6.6%, 29.5%, and 537% in patients without portal hypertension, and 23.4%, 51.9%, and 63.6% in patients with portal hypertension, respectively. The difference was statistically significant (p = 0.011). Univariate and multivariate analysis showed that portal hypertension was an independent predictor for distant intrahepatic tumor spread (p = 0.008). Conclusion: For HCC patients with Child-Pugh class A, portal hypertension adversely affected distant intrahepatic tumor progression.

Predictions of PD-L1 Expression Based on CT Imaging Features in Lung Squamous Cell Carcinoma (편평세포폐암에서 CT 영상 소견을 이용한 PD-L1 발현 예측)

  • Seong Hee Yeo;Hyun Jung Yoon;Injoong Kim;Yeo Jin Kim;Young Lee;Yoon Ki Cha;So Hyeon Bak
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.2
    • /
    • pp.394-408
    • /
    • 2024
  • Purpose To develop models to predict programmed death ligand 1 (PD-L1) expression in pulmonary squamous cell carcinoma (SCC) using CT. Materials and Methods A total of 97 patients diagnosed with SCC who underwent PD-L1 expression assay were included in this study. We performed a CT analysis of the tumors using pretreatment CT images. Multiple logistic regression models were constructed to predict PD-L1 positivity in the total patient group and in the 40 advanced-stage (≥ stage IIIB) patients. The area under the receiver operating characteristic curve (AUC) was calculated for each model. Results For the total patient group, the AUC of the 'total significant features model' (tumor stage, tumor size, pleural nodularity, and lung metastasis) was 0.652, and that of the 'selected feature model' (pleural nodularity) was 0.556. For advanced-stage patients, the AUC of the 'selected feature model' (tumor size, pleural nodularity, pulmonary oligometastases, and absence of interstitial lung disease) was 0.897. Among these factors, pleural nodularity and pulmonary oligometastases had the highest odds ratios (8.78 and 16.35, respectively). Conclusion Our model could predict PD-L1 expression in patients with lung SCC, and pleural nodularity and pulmonary oligometastases were notable predictive CT features of PD-L1.

Abbreviated Magnetic Resonance Imaging for Breast Cancer Screening: Concept, Early Results, and Considerations

  • Eun Sook Ko;Elizabeth A. Morris
    • Korean Journal of Radiology
    • /
    • v.20 no.4
    • /
    • pp.533-541
    • /
    • 2019
  • Breast magnetic resonance imaging (MRI) has been increasingly utilized, especially in screening for high-risk cases, because of its high sensitivity and superior ability to detect cancers as compared with mammography and ultrasound. Several limitations such as higher cost, longer examination time, longer interpretation time, and low availability have hindered the wider application of MRI, especially for screening of average-risk women. To overcome some of these limitations and increase access to MRI screening, an abbreviated breast MRI protocol has been introduced. Abbreviated breast MRI is becoming popular and challenges the status quo. This review aims to present an overview of abbreviated MRI, discuss the current findings, and introduce ongoing prospective trials.