• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.034 seconds

Quantitative Evaluation of the Corticospinal Tract Segmented by Using Co-registered Functional MRI and Diffusion Tensor Tractography (정상인에서 기능적 뇌 자기공명영상과 확산텐서영상 합성기법을 이용한 피질척수로의 위치에 따른 정량적 분석)

  • Jang, Sung-Ho;Hong, Ji-Heon;Byun, Woo-Mok;Hwang, Chang-Ho;Yang, Dong-Seok
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.1
    • /
    • pp.40-46
    • /
    • 2009
  • Purpose : The purpose of this study was to investigate the quantitative evaluation of the corticospinal tract (CST) at the multiple levels by using functional MRI (fMRI) co-registered to diffusion tensor tractography (DTT). Materials and Methods : Ten normal subjects without any history of neurological disorder participated in this study. fMRI was performed at 1.5 T MR scanner using hand grasp-release movement paradigm. DTT was performed by using DtiStudio on the basis of fiber assignment continuous tracking algorithm (FACT). The seed region of interest (ROI) was drawn in the area of maximum fMRI activation during the motor task of hand grasp-release movement on a 2-D fractional anisotropy (FA) color map, and the target ROI was drawn in the cortiocospinal portion of anterior lower pons. We have drawn five ROIs for the measurement of FA and apparent diffusion coefficient (ADC) along the corona radiata (CR) down to the medulla. Results : The contralateral primary sensorimotor cortex (SM1) was mainly found to be activated in all subjects. DTT showed that tracts originated from SM1 and ran to the medulla along the known pathway of the CST. In all subjects, FA values of the CST were higher at the level of the midbrain and posterior limb of internal capsule (PLIC) than the level of others. Conclusion : Our study showed that co-registered fMRI and DTT has elucidated the state of CST on 3-D and analyzed the quantitative values of FA and ADC at the multiple levels. We conclude that co-registered fMRI and DTT may be applied as a useful tool for clarifying and investigating the state of CST in the patients with brain injury.

  • PDF

Prevalence and Risk Factors of Gallstones in Adult Health Screening Population (건강한 성인의 담석 유병률과 위험인자)

  • Lee, Mi-Hwa;Kwon, Duck-Moon;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.287-294
    • /
    • 2014
  • Gallstone is the most common disease of the biliary system. Korean has experienced an increase in the percentage of cholesterol gallstones. The major risk factors associated with cholesterol gallstones are age, gender as well as obesity. This study was designed to determine the prevalence of gallstones in the last three years and evaluate the associated risk factors in the population who underwent health screening. The study population consisted of 2,484 males and 2,212 females who visited the health promotion center in Dalseogu, Daegu in Korea from January 2011 to December 2013. Each participant in the study had their biliary system gallbladder examined using ultrasonography. Classified as underweight, normal weight or overweight using the population of obese according to the body mass index, and classified according to mood diagnosis of diabetes presented by the American Diabetes Association. Fasting blood glucose and number of liver function, the divided the control group by referring to the normal liver function values used herein. The geological map, I was classified as NCEP APT III. A showed of total 148 people were found to have gallstones. The prevalence of sex among 148 patients (3.15%) 84 men (1.79%) and 64 women 1.36%) which shows significantly there is little difference. 1.84% 40 years and below, 3.38% 40's showed age prevalence was 4.66% in 50's and above. In addition, Total-cholesterol was at the most in 52 people, LDL-cholesterol in 398 people, Triglyceride in 36 people, HDL-cholesterol in 19 people. The abnormal group, was created from the total-cholesterol categories from a physical examination of a subject that has been found to be gallstones in the gallbladder. A result of conducting the univariate analysis shows the prevalence of gallstones, a correlation that is meaningful. The logistic regression analysis of multiple ages was chosen to show risk factors age independent cholelithiasis. In spite of the conclusion, gallstones are not displayed in relation to the metabolic syndrome but in order to clarify this, not only the subject of a health examination is needed but, a further study of the general public when possible.

Evaluation on Protrusion of the Imaginary Prostate Volume Using Three-Dimensional Volume Rendering (3차원 볼륨 렌더링을 이용한 가상 돌출형 전립선 부피 평가)

  • Seoung, Youl-Hun;Joo, Yong-Hyun;Rhim, Jae-Dong;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.208-215
    • /
    • 2009
  • This study is to compare the accuracy of evaluation regarding the volume of the prostate, which three-dimensional volume rendering was produced the shape of protrusion, by measuring two kinds of craniocaudal length from the top of the protrusion and from the exclusion of the protrusion as the starting points. For the imaginary protrusion prostate models, total of 10 models were roughly made by using devils-tongue jelly and changing each of the 10 ml of capacity from 10 ml to 100 ml. For the protrusion prostate models aimed at estimating the real volume, through 64 cannel computed tomography (CT) and 3.0 tesla magnetic resonance image (MRI) were conducted by planimetry technique from three-dimensional volume rendering. And then we performed to evaluate on significance of these volumes by wilcoxon signed rank test. Also the obtained volumes data by ellipsoid volume formula were measured the volume of protrusion prostate models two times with each method using the two kinds of craniocaudal length from top of the protrusion and from exclusion of the protrusion as the starting points. Finally, the significance of differences using wilcoxon signed rank test was evaluated between the real volume by planimetry technique and the measured volume by ellipsoid volume formula from three-dimensional volume rendering. The average of the protrusion length on the models was $0.90{\pm}0.18\;mm$ in CT and was $0.75{\pm}0.11\;mm$ in MRI. There were not statistically significant difference between MRI and CT from the volume of protrusion prostate models (p=0.414). In MRI (p=0.139) and CT (p=0.057), there were not statistically significant difference between the real volume by planimetry technique and the measured volume by ellipsoid volume from exclusion of the protrusion as the starting points. While, there were statistically significant difference between the real volume by planimetry technique and the measured volume by ellipsoid volume from top of the protrusion as the starting points in MRI (p=0.005) and CT (p=0.005). For the accurate measurement of the protrusion prostate models, the craniocaudal length of the prostate should be measured from the exclusion of the protrusion as the starting points.

  • PDF

Radiological Safety Perception Change after Spatial Dose Measurement of Radiology Department Students (방사선학과 학생들의 공간선량 측정 경험이 방사선 안전 인식에 미치는 영향)

  • Moon, Jae Mi;Park, Sang Tae;Yu, Ji Hyun
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.3
    • /
    • pp.174-180
    • /
    • 2015
  • There are currently many research papers on the knowledge, perceptions and actions of radiation-related staff, but hardly any papers on radiation major students in college who are to be staff members of radiation related jobs in the future. It is of course important to understand the perceptions of staff working on the lines and change their knowledge and perceptions, but in the long term it seems more efficient to understand those who are in the stage of being educated to be staff members-their knowledge and perception of radiation so that ultimately they can attain the right kind of understanding. Therefore the aim of this study is to grasp the pre-radiation staff's basic concept of radiation and space dose, their understanding of radiation safety based on this, and whether there is a change in their perception before and after the space dose measurement experiment; in the end this is to see if the space dose measurement experiment is effective in changing perception on radiation safety. This study took as its subject 64 students majoring radiation in college, I.e. pre-radiation staff members, and gauged their basic conceptualization of radiation, understanding of space dose, and understanding of radiation safety; in the X-ray room within the department the students were asked to measure space dose for themselves, so as to see whether there was a change in their understanding of radiation safety before and after the experiment, according to their understanding of the basic concept of radiation and of space dose. As a result of the space dose measurement experiment, students' increased basic knowledge of concept of radiation and understanding of the dangers of space dose were noteworthy, and accordingly their understanding of radiation safety became stricter and more conservative. In spite of this, their work ethic stayed in the lead of their understanding of radiation safety; this implies the need of a more departmentalized safety education program. Therefore instead of safety education that simply uses visual-audial material in a kind of lecture, I suggest here that there be a more experiential safety education program that enables learners to try out space dose measurement experiments for themselves, a work ethic education that aims for a conventional point of view towards radiation safety as well as a stern attitude.

The Study for Results of Complex Cystic Breast Masses by Biopsy on Ultrasound (초음파상 복합성 낭성 유방 종괴의 조직 검사 결과에 관한 연구)

  • Kang, Hye-Kyoung;Dong, Kyung-Rae
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.129-134
    • /
    • 2008
  • Purpose: We examined the roles of Ultrasonography conductors by analyzing the results of tissue biopsy of complex cystic masse under the guidance of breast US. Objects and methods: This study was performed to a group of 178 who showed breast US indicating complex cystic masses among 342 patients who were definitely diagnosed by tissue biopsies and operations in our hospital from June 30th, 2003 to June 30th, 2007. The evaluation of tissues around, calcification, the distribution state of blood flow were excluded from the analysis subjects and logic 200 made by GE corporation and gun for core biopsy(Kimal corp., K7/MBD23) were used in this study. Results: The biopsy results of 178 subjects showed FCC (fibrocystic change)(n=56 : 31.4%), Fibrosis (n=41 : 23.0%), Fibroadenoma (n=20 : 11.2%), Epithelial hyperplasia (n=17 : 9.6%), Carcinoma (n=15 : 8.4%), Fibroadipose (n=8 : 4.5%), Sclerosing adenosis (n=7 : 3.9%), Duct ectasia (n=5 : 2.8%), Papiloma (n=5 : 2.8%), and Fat necrosis (n=1 : 0.6%), Hemangioma (n=1 : 0.6%), Abscess (n=1 : 0.6%), Dystrophic calcification(n=1 : 0.6%). Conclusion: The US showed that the results of the tissue biopsy of complex cystic masses were mostly carcinoma(8.4%). Most of them were benign and only 9.6% of epithelial hyperplasia which has high progression rate into malignant tumors epidemically showed malignancy. Most of them were included in the spectrum of fibrous cystic nodule. Even though these results are confirmed, further studies are required. As a result, a nodule which is not certified by US should be right to take the tissue biopsy, but if it's difficult due to patients or another reasons, re-check tests in three months are required. And systemic ultrasonography evaluation should be well recognized to conduct more careful and specific tests.

  • PDF

Evaluation of TOF MR Angiography and Imaging for the Half Scan Factor of Cerebral Artery (유속신호증강효과의 자기공명혈관조영술을 이용한 뇌혈관검사에서 Half Scan Factor 적용한 영상 평가)

  • Choi, Young Jae;Kweon, Dae Cheol
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.3
    • /
    • pp.92-98
    • /
    • 2016
  • To aim of this study was to assess the full scan and half scan of imaging with half scan factor. Patients without a cerebral vascular disease (n = 30) and were subject to the full scan half scan, and set a region of interest in the cerebral artery from the three regions (C1, C2, C3) in the range of 7 to 8 mm. MIP (maximum intensity projection) to reconstruct the images in signal strength SNR (signal to noise ration), PSNR (peak signal noise to ratio), RMSE (root mean square error), MAE (mean absolute error) and calculated by paired t-test for use by statistics were analyzed. Scan time was half scan (4 minutes 53 seconds), the full scan (6 minutes 04 seconds). The mean measurement range (7.21 mm) of all the ROI in the brain blood vessel, was the SNR of the first C1 is completely scanned (58.66 dB), half-scan (62.10 dB), a positive correlation ($r^2=0.503$), for the second C2 SNR is completely scanned (70.30 dB), half-scan (74.67 dB) the amount of correlation ($r^2=0.575$), third C3 of a complete scan SNR (70.33 dB), half scan SNR (74.64 dB) in the amount of correlation between the It was analyzed with ($r^2=0.523$). Comparative full scan with half of SNR ($4.75{\pm}0.26dB$), PSNR ($21.87{\pm}0.28dB$), RMSE ($48.88{\pm}1.61$), was calculated as MAE ($25.56{\pm}2.2$). SNR is also applied to examine the half-scans are not many differences in the quality of the two scan methods were not statistically significant in the scan (p-value > .05) image takes less time than a full scan was used.

Accurate Quality Control Method of Bone Mineral Density Measurement -Focus on Dual Energy X-ray Absorptiometry- (골밀도 측정의 정확한 정도관리방법 -이중 에너지 방사선 흡수법을 중심으로-)

  • Kim, Ho-Sung;Dong, Kyung-Rae;Ryu, Young-Hwan
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.361-370
    • /
    • 2009
  • The image quality management of bone mineral density is the responsibility and duty of radiologists who carry out examinations. However, inaccurate conclusions due to lack of understanding and ignorance regarding the methodology of image quality management can be a fatal error to the patient. Therefore, objective of this paper is to understand proper image quality management and enumerate methods for examiners and patients, thereby ensuring the reliability of bone mineral density exams. The accuracy and precision of bone mineral density measurements must be at the highest level so that actual biological changes can be detected with even slight changes in bone mineral density. Accuracy and precision should be continuously preserved for image quality of machines. Those factors will contribute to ensure the reliability in bone mineral density exams. Proper equipment management or control methods are set with correcting equipment each morning and after image quality management, a phantom, recommended from the manufacturer, is used for ten to twenty-five measurements in search of a mean value with a permissible range of ${\pm}1.5%$ set as standard. There needs to be daily measurement inspections on the phantom or at least inspections three times a week in order to confirm the existence or nonexistence of changes in values in actual bone mineral density. in addition, bone mineral density measurements were evaluated and recorded following the rules of Shewhart control chart. This type of management has to be conducted for the installation and movement of equipment. For the management methods of inspectors, evaluation of the measurement precision was conducted by testing the reproducibility of the exact same figures without any real biological changes occurring during reinspection. Bone mineral density inspection was applied as the measurement method for patients either taking two measurements thirty times or three measurements fifteen times. An important point when taking measurements was after a measurement whether it was the second or third examination, it was required to descend from the table and then reascend. With a 95% confidence level, the precision error produced from the measurement bone mineral figures came to 2.77 times the minimum of the biological bone mineral density change. The value produced can be stated as the least significant change (LSC) and in the case the value is greater, it can be stated as a section of genuine biological change. From the initial inspection to equipment moving and shifter, management must be carried out and continued in order to achieve the effects. The enforcement of proper quality control of radiologists performing bone mineral density inspections which brings about the durability extensions of equipment and accurate results of calculations will help the assurance of reliable inspections.

  • PDF

Analysis of Influencing Factors Related to Health Promotion Behavior in Hospital Radiological Technologists (종합병원 방사선사의 건강증진행위 관련요인 분석)

  • Ko, Jong-Kyung;Kwon, Duk-Mun;Kang, Yeong-Han
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.381-391
    • /
    • 2009
  • Purposes : The purpose of this study was to analyze factors that could affect health of radiological technologists, which is useful for health care and development of programs for health promotion. Methods : Subjects were 234 of radiological technologists who work in general hospitals. Some questionnaires were made about perceptions of health condition and promotional behavior of health for this study. The questionnaires of health perception were 20 items that consist of the present condition of health, health concern and sensitivity. The reliability was sufficient(Cronbach's $\alpha=0.79$). The other questionnaires about health promotion behavior were 47 items that consist of self-realization, health responsibility, exercise, nutrition, personal relationships, and stress management. The results turned out to bewas sufficient (Cronbach's $\alpha=0.93$). Every data was treated statistically, comparison of average(t-test, ANOVA), correlation, and multiple regression. Results : Related factors to health promotion behavior were age, marriage, salary, class of one's position, career, employment, and religion, in general features. In health life habit, related factors were smoke and exercise. Results of health promotion behavior was 2.90 of mean score, 0.37 of standard deviation. Correlations between factors of health perception and health promotion behavior was positive(p<0.01). Health promotion behavior were affected by sensitivity, presents condition of health, exercise, smoke, career. Sensitivity was the most affectable variable, which means that promotional behavior score became higher and higher as the score of sensitivity and present condition were increased. In addition, persons who exercise regularly, had been smoked, and has higher career showed higher score of promotional behavior. Conclusion : Radiological technologists have to keep their health, trying not to infected by a disease. Most of all, no smoking and regular exercise are the most important thing to all of members.

  • PDF

Comparative Analysis of Signal Intensity and Apparent Diffusion Coefficient at Varying b-values in the Brain : Diffusion Weighted-Echo Planar Image ($T_2^*$ and FLAIR) Sequence (뇌의 확산강조 영상에서 b-value의 변화에 따른 신호강도, 현성확산계수에 관한 비교 분석 : 확산강조 에코평면영상($T_2^*$ 및 FLAIR)기법 중심으로)

  • Oh, Jong-Kap;Im, Jung-Yeol
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.313-323
    • /
    • 2009
  • Diffusion-weighted imaging (DWI) has been demonstrated to be a practical method for the diagnosis of various brain diseases such as acute infarction, brain tumor, and white matter disease. In this study, we used two techniques to examine the average signal intensity (SI) and apparent diffusion coefficient (ADC) of the brains of patients who ranged in age from 10 to 60 years. Our results indicated that the average SI was the highest in amygdala (as derived from DWI), whereas that in the cerebrospinal fluid was the lowest. The average ADC was the highest in the cerebrospinal fluid, whereas the lowest measurement was derived from the pons. The average SI and ADC were higher in $T_2^*$-DW-EPI than in FLAIR-DW-EPI. The higher the b-value, the smaller the average difference in both imaging techniques; the lower the b-value, the greater the average difference. Also, comparative analysis of the brains of patients who had experienced cerebral infarction showed no distinct lesion in the general MR image over time. However, there was a high SI in apparent weighted images. Analysis of other brain diseases (e.g., bleeding, acute, subacute, chronic infarction) indicated SI variance in accordance with characteristics of the two techniques. The higher the SI, the lower the ADC. Taken together, the value of SI and ADC in accordance with frequently occurring areas and various brain disease varies based on the b-value and imaging technique. Because they provide additional useful information in the diagnosis and treatment of patients with various brain diseases through signal recognition, the proper imaging technique and b-value are important for the detection and interpretation of subacute stroke and other brain diseases.

  • PDF

Study of External Radiation Expose Dose on Hands of Nuclear Medicine Workers (핵의학 종사자에서 손 부위의 외부 피폭선량 연구)

  • Park, Jun-Chul;Pyo, Sung-Jae
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.141-149
    • /
    • 2012
  • The aims of this study are to assess external radiation exposed doses of body and hands of nuclear medicine workers who handle radiation sources, and to measure radiation exposed doses of the hands induced by a whole body bone scan with high frequency and handling a radioactive sources like $^{99m}Tc$-HDP and $^{18}F$-FDG in the PET/CT examination. Skillful workers, who directly dispense and inject from radiation sources, were asked to wear a TLD on the chest and ring finger. Then, radiation exposed dose and duration exposed from daily radiation sources for each section were measured by using a pocket dosimeter for the accumulated external doses and the absorbed dose to the hands. In the survey of four medical institutions in Incheon Metropolitan City, only one of four institutions has a radiation dosimeter for local area like hands. Most of institutions uses radiation shielding devices for the purpose of protecting the body trunk, not local area. Even some institutions were revealed not to use such a shielding device. The exposed doses on the hands of nuclear medicine workers who directly handles radioactive sources were approximately twice as much as those on the body. The radiation exposure level for each section of the whole body bone scan with high frequency and that of the PET/CT examination showed that radiation doses were revealed in decreasing order of synthesis of radioactive medicine and installation to a dispensing container, dispensing, administering and transferring. Furthermore, there were statistically significant differences of radiation exposure doses of the hands before and after wearing a syringe shielder in administration of a radioactive sources. In this study, although it did not reach the permissible effective dose for nuclear medicine, the occupational workers were exposed by relatively higher dose level than the non-occupational workers. Therefore, the workers, who closely exposed to radioactive sources should be in compliance with safety management regulations, and take actions to maximally reduce locally exposed dose to hands monitoring with ring TLD.