Noise Reduction on Low Tube Voltage CT Images (저관전압 CT영상에서 발생되는 노이즈 제거)

  • Choi, Seokyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.1
    • /
    • pp.63-68
    • /
    • 2017
  • To reduce the exposure dose in head CT, the use of low tube voltage is required. However, increasing noise may cause errors in the second data processing. In this study, we proposed a method to reduce noise by using low tube voltage. Experimental results show that the noise level is high at 100kVp and lowest at 140 kVp. The dose was lower at 100 kVp and higher at 140 kVp. As a result of applying the wavelet according to the threshold value, the noise value in the wavelet Th30 decreased to 4.51. Using the parameter condition(100 kVp, rotation time 0.5 sec, dose: 40.64 mGy) and the wavelet Th 30, the dose reduction of 65.3% was possible. We believe that applying the proposed method to head CT images will help to patient safety and interpret accurate information.

Removal of Ring Artifact in Computed Tomography (전산화단층촬영장치에서 링 아티팩트 제거)

  • Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.6
    • /
    • pp.403-408
    • /
    • 2015
  • Hard X-ray has been widely used in medical and industrial fields because it can be applied to observe the inside of a sample. Computed tomography provides sectional images of the sample through the reconstruction of the projection images. The quality of sectional images strongly depends on that of projection images. Ring artifact appeared on the seconal image can be made by the abnormal pixels of the detector used. In this study, we examine the ring artifact ratio in the circle phantom as a function of detection error of the detector used in computed tomography. The ring artifact increased with the increment of detection error under parallel and fan beam geometries and strongly increased near the center of rotation. The corrections, dead pixel and flat field corrections, for the images taken with the detector are required before the image reconstruction process to reduce the ring artifact in the computed tomography.

A Study on Optimized MRI Fat-Saturation Technique for Brachial Plexus Patients : Focused on SPAIR and STIR Fat-Saturation (상완신경총 환자에서 최적의 자기공명영상 지방소거 기법에 관한 연구 : SPAIR, STIR 지방소거 중심으로)

  • Goo, Eunhoe
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.5
    • /
    • pp.271-278
    • /
    • 2014
  • The purpose of this study is to know optimized fat suppression techniques for brachial plexus compared with STIR and SPAIR T1, T2 techniques. A total of 30 normal volunteers without brachial plexus disease were studied on a 3.0 T MRI scanner. As an analytical method, SNR, CNR, 4-point grading scale were evaluated by using three pulse sequences. As a quantitative analysis, the SNR, CNR for SPAIR T1 technique provided high value in branchial plexus roots (03.07, -2.25), branchial plexus trunks(06.70, 36.31)(p<0.05). As a qualitative Analysis, The visibility for delineation of brachial plexus, fat suppression, artifact was significantly better on SPAIR T1(3.2, 3.6, 3.4) technique(p<0.05).

Magnetic resonance imaging-based temporomandibular joint space evaluation in tempormandibular disorders (측두하악관절증에서 자기공명영상을 이용한 측두하악관절의 관절강 평가)

  • Nah, Kyung-Soo
    • Imaging Science in Dentistry
    • /
    • v.37 no.1
    • /
    • pp.15-18
    • /
    • 2007
  • Purpose : Disc and condylar position were observed on MRIs of temporomandibular joint disorder patients and condylar position agreement between MRI and tranascranal radiography was evaluated. Materials and Methods MRI and transcranial radiographs of both TM joints from 67 patients with temporemandibular disorder were used. On MRI, the position and shape of disc and condylar position as anterior, middle, posterior was evaluated at medial, center, and lateral views. On transcranial radiographs, condylar position was evaluated using the shortest distance from condyle to fossa in anterior, superior, and posterior directions. Results. 1. On MRI, 96 joints (71.6%) of 134 had anterior disc dispalcement with reduction and 38 joints (28.4%) without reduction. 2. Fourteen (14.6%) of 96 reducible joints showed anterior condylar position, 19 (19.8%) showed central position, 63 joints (65.6%) showed posterior position. Two joints (5.3%) of 38 non-reducible joints showed anterior condylar position, while 9 (23.7%) showed central position, and 27 (71.1%)-posterior position. 3. In 85 joints (63.4%) of 134, the transcranial condylar position agreed with that of the central MRI view, 10 joints (7.5%) with that of medial, 16 joints (11.9%) with that of lateral, and 23 joints (17.2%) disagreed with that of MRI. Conclusion : On MRT, most oi the reducible and non-reducible joints showed posterior condylar position. Transcranial radiographs taken with machine designed for TMJ had better agreement of condylar position with that of MRI. Extremely narrow joint spaces or very posterior condylar positions observed on transcranial radiographs had a little more than fifty percent agreement with those of MRIs.

  • PDF

External apical root resorption in maxillary incisors in orthodontic patients: associated factors and radiographic evaluation

  • Nanekrungsan, Kamonporn;Patanaporn, Virush;Janhom, Apirum;Korwanich, Narumanus
    • Imaging Science in Dentistry
    • /
    • v.42 no.3
    • /
    • pp.147-154
    • /
    • 2012
  • Purpose: This study was performed to evaluate the incidence and degree of external apical root resorption of maxillary incisors after orthodontic treatment and to evaluate particular associated factors related to external apical root resorption. Materials and Methods: The records and maxillary incisor periapical radiographs of 181 patients were investigated. Crown and root lengths were measured and compared on the pre- and post-treatment periapical radiographs. Crown length was measured from the center of the incisal edge to the midpoint of the cemento-enamel junction (CEJ). Root length was measured from the CEJ midpoint to the root apex. A correction factor for the enlargement difference was used to calculate root resorption. Results: The periapical radiographs of 564 teeth showed that the average root resorption was $1.39{\pm}1.27$ ($8.24{\pm}7.22$%) and $1.69{\pm}1.14$ mm ($10.16{\pm}6.78%$) for the maxillary central and lateral incisors, respectively. The results showed that the dilacerated or pointed roots, maxillary premolar extraction cases, and treatment duration were highly significant factors for root resorption (p<0.001). Allergic condition was a significant factor at p<0.01. Age at the start of treatment, large overjet, and history of facial trauma were also factors significantly associated with root resorption (p<0.05). There was no statistically significant difference in root resorption among the factors of gender, overbite, tongue-thrusting habit, types of malocclusion, and types of bracket. Conclusion: These results suggested that orthodontic treatment should be carefully performed in pre-treatment extraction patients who have pointed or dilacerated roots and need long treatment duration.

Radiographic examination protocol and patient dose in lateral cephalometric radiography in Korea (국내 의료기관에서 측방두부규격방사선촬영시 임상에서의 촬영조건 및 환자 선량)

  • Choi, Jin-Woo
    • Imaging Science in Dentistry
    • /
    • v.40 no.4
    • /
    • pp.165-169
    • /
    • 2010
  • Purpose : To survey the radiographic examination protocol for lateral cephalometric radiographic examinations and to measure their patient doses in Korea and to compare the dose according to the size of hospital, the type of image receptor system, and the installation duration. Materials and Methods : The radiographic examination protocols (kVp, mA, and exposure time) for lateral cephalometric radiography were surveyed with 61 cephalometric radiographic equipments and their patient dose-area product (DAP) measured with a DAP meter (DIAMENTOR M4-KDK, PTW, Freiburg, Germany) for 51 cephalometric radiographic equipments. The radiographic examination protocols and patient doses were compared according to the size of hospital (university dental hospital, dental hospital, and dental clinic), the type of image receptor system (film-based, DR and CR type) and the installation duration, respectively. SPSS 12.0.1 for Windows (SPSS Inc., Chicago, USA) was used for independent t-test and ANOVA test. Results : The average protocols were 77.0 kVp, 12.7 mA, 6.2 second for cephalometric radiography. The average patient dose (DAP) was $128.0mGy\;cm^2$ and 3rd quartile dose (DAP) $161.1mGy\;cm^2$ for cephalometric radiography for adult male. There was no statistically significant difference at average patient DAP according to the size of hospital, the type of image receptor system, and the installation duration, repectively. Conclusion : The average patient dose was $128.0mGy\;cm^2$ and the third quartile patient dose $161.1mGy\;cm^2$ for lateral cephalometric radiography for adult male in Korea.

AN ELECTRON MICROSCOPIC STUDY ON THE COBALT-60 IRRADIATION EFFECTS ON THE SALIVARY GLAND OF THE WHITE RAT (Cobalt-60 방사선조사가 백서의 타액선에 미치는 영향에 관한 전자현미경적 연구)

  • Park Chang Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.15 no.1
    • /
    • pp.27-40
    • /
    • 1985
  • This study was undertaken to observe the histopathologic changes in salivary gland of the white rats when exposed to megavoltage fractionated dose of cobalt-60 irradiation and 78 female white rats, weighing approximately 180gm, were divided into control and 3 experimental groups. Irradiation on experimental groups was delivered by using 6000 curies MeV ALCYON cobalt-60 teletherapy unit with exposure rate 183 rads per minute, in source skin distance 80cm, 600 rads every 3 days. In experimental groups, Group Ⅰwas irradiated of total dose 1200 rads for a period of 6 days, Group Ⅱ was irradiated of total dose 2400 rads for a period of 12 days and Group Ⅲ was irradiated of total dose of 4800 rads for a period of 24 days. The animals were sacrificed serially at 3 hours, 6 hours, 10 hours, 1st day, 4th day, 7th day after each completion of irradiation exposure. At sacrifice, salivary glands were excised and examined microscopically and electromicroscopically. The results were as follows: 1. The acinar cells of parotid and submaxillary gland showed damage varied with dose, 1200 rads resulted in very mild injury while 4800 rads caused most extensive injury. 2. The acinar cells of parotid and submandibular gland showed similar ultrastructural alterations, appeared as pleomorphic nucleus, decreased numbers and pleomorphism of secretory granules, distention of rough endplasmic reticulum, expansion and pallor appearance of mitochondria, and hypertrophy of Golgi complex. 3. Parotid serous cells were the most sensitive components, displaying morphological alterations of radiation damage as early as 3 hours, followed by submandibular seromucinous cells and secretory tubular cells. 4. The mucous cells of sublingual gland, as well as the whole ductal lining cells of each salivary gland, displayed no significant alterations. No evidence of microvascular injury through whole experimental groups indicated that microvascular impairment does not contribute to early salivary gland injury.

  • PDF

A Roentgenographic Cephalometric Study of Temporomandibular Joint Subluxation (악관절아탈구증에 대한 두부방사선계측학적 연구)

  • Kim Han Pyong
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.11 no.1
    • /
    • pp.23-32
    • /
    • 1981
  • The purpose of this study was to assess temporomandibular joint subluxation by means of cephalometry using two lateral cephalograms from each person with in centric occlusion and wide-open mouth position, and to compare patient group with subluxation to normal control group in the measurements and correlation coefficient. The 200 cephalograms of 100 Korean adults, patient group consisted of 24 females and 26 males ranged from 17 to 63 years age and the normal control group consisted of 20 females and 30 males ranged from 18 to 56 years age, were studied and analyzed statistically. The results were as follows; 1. In the comparison of patient group vs normal control group in the measurements, statistically significant differences were found in C-C', C'-PTM, K-FH, K-PTM, Gn-Gn', C-S-C', Gn-S-Gn', Gn-K-Gn', GoGn-SN, and GoGn-Go'Gn'. K-point* of patient group was located antero - superiorly than of normal control group, and the significance level was higher in K-PTM than in K-FH. There was no statistically significant difference found in local relationship of C-point between patient group and normal control group. The values of correlation coefficient among all measurements were in 0.958≥r≥-0.760, and the highest value was in Gn-Gn' to GoGn-Go'Gn' and Gn-K-Gn' to Gn-Gn', and the lowest value was in C'-PTM to Gn-K-Gn' of normal control group. K was determined as a point of intersection by a perpendicular bisector of Gn-Gn' and a perpendicular bisector of C-C'.

  • PDF

Leakage and scattered radiation from hand-held dental x-ray unit (이동용 치과 X선 발생장치의 누설 및 산란 선량에 관한 연구)

  • Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.37 no.2
    • /
    • pp.65-68
    • /
    • 2007
  • Purpose: To compare the leakage and scattered radiation from hand-held dental X-ray unit with radiation from fixed dental X-ray unit. Materials and Methods: For evaluation we used one hand-held dental X-ray unit and Oramatic 558 (Trophy Radiologie, France), a fixed dental X-ray unit. Doses were measured with Unfors Multi-O-Meter 512L at the right and left hand levels of X-ray tube head part for the scattered and leakage radiation when human skull DXTTR III was exposed to both dental X-ray units. And for the leakage radiation only, doses were measured at the immediately right, left, superior and posterior side of the tube head part when air was exposed. Exposure parameters of handheld dental X-ray unit were 70 kVp, 3 mA, 0.1 second, and of fixed X-ray unit 70 kVp, 8 mA, 0.45 second. Results: The mean dose at the hand level when human skull DXTTR III was exposed with portable X-ray unit $6.39{\mu}Gy$, and the mean dose with fixed X-ray unit $3.03{\mu}Gy$ (p<0.001). The mean dose at the immediate side of the tube head part when air was exposed with portable X-ray unit was $2.97{\mu}Gy$ and with fixed X-ray unit the mean dose was $0.68{\mu}Gy$ (p<0.01). Conclusions: The leakage and scattered radiation from hand-held dental radiography was greater than from fixed dental radiography.

  • PDF

Usefulness of Cerebellar Transverse Diameter and Abdominal Circumference Ratio in Fetal Growth Evaluation (태아성장평가에서 소뇌횡직경과 복부둘레비의 유용성)

  • Yang, Sung-Hee
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.649-656
    • /
    • 2021
  • The purpose of this study was to evaluate the appropriateness of transverse cerebellar diameter and abdominal circumference (TCD/AC ratio) as variables to evaluate intrauterine growth restriction of the fetus. From April 2019 to March 2021, 784 pregnant women who underwent ultrasound as a regular checkup at I hospital were retrospectively analyzed using the transverse cerebellar diameter and abdominal circumference measurements. In simple regression analysis, transverse cerebellar diameter and abdominal circumference had an effect of 97.2% and 97.5% on gestational age (p<0.001). In addition, the percentile of the TCD/AC ratio for each gestational age group was calculated through frequency analysis, and the 95th percentile of intrauterine growth restriction prediction was 14.2. As a result, it is thought that the TCD/AC ratio can be used as a useful variable to evaluate the normal growth of the fetus and predict the IUGR.