• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.027 seconds

Impact of Collateral Circulation on Futile Endovascular Thrombectomy in Acute Anterior Circulation Ischemic Stroke

  • Yoo Sung Jeon;Hyun Jeong Kim;Hong Gee Roh;Taek-Jun Lee;Jeong Jin Park;Sang Bong Lee;Hyung Jin Lee;Jin Tae Kwak;Ji Sung Lee;Hee Jong Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.67 no.1
    • /
    • pp.31-41
    • /
    • 2024
  • Objective : Collateral circulation is associated with the differential treatment effect of endovascular thrombectomy (EVT) in acute ischemic stroke. We aimed to verify the ability of the collateral map to predict futile EVT in patients with acute anterior circulation ischemic stroke. Methods : This secondary analysis of a prospective observational study included data from participants underwent EVT for acute ischemic stroke due to occlusion of the internal carotid artery and/or the middle cerebral artery within 8 hours of symptom onset. Multiple logistic regression analyses were conducted to identify independent predictors of futile recanalization (modified Rankin scale score at 90 days of 4-6 despite of successful reperfusion). Results : In a total of 214 participants, older age (odds ratio [OR], 2.40; 95% confidence interval [CI], 1.56 to 3.67; p<0.001), higher baseline National Institutes of Health Stroke Scale (NIHSS) scores (OR, 1.12; 95% CI, 1.04 to 1.21; p=0.004), very poor collateral perfusion grade (OR, 35.09; 95% CI, 3.50 to 351.33; p=0.002), longer door-to-puncture time (OR, 1.08; 95% CI, 1.02 to 1.14; p=0.009), and failed reperfusion (OR, 3.73; 95% CI, 1.30 to 10.76; p=0.015) were associated with unfavorable functional outcomes. In 184 participants who achieved successful reperfusion, older age (OR, 2.30; 95% CI, 1.44 to 3.67; p<0.001), higher baseline NIHSS scores (OR, 1.12; 95% CI, 1.03 to 1.22; p=0.006), very poor collateral perfusion grade (OR, 4.96; 95% CI, 1.42 to 17.37; p=0.012), and longer door-to-reperfusion time (OR, 1.09; 95% CI, 1.03 to 1.15; p=0.003) were associated with unfavorable functional outcomes. Conclusion : The assessment of collateral perfusion status using the collateral map can predict futile EVT, which may help select ineligible patients for EVT, thereby potentially reducing the rate of futile EVT.

Influence of Iodinated Magnetic Resonance Contrast Media and Isotope 99mTc on Changes of Computed Tomography Number

  • Kim, Sang-Beom;Lee, Jin-Hyeok;Ahn, Jae-Ouk;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.20 no.3
    • /
    • pp.302-307
    • /
    • 2015
  • The purpose of the study was to identify how isotope and magnetic resonance imaging (MRI) contrast media impact on noise to computed tomography (CT) examination. For the study, divide the phantoms to two groups: 1) saline, saline + different kinds of contrast agent without $^{99m}Tc$ administration; 2) $^{99m}Tc$ administration: saline, saline + different kinds of contrast agent with $^{99m}Tc$ administration. CT contrast agent was used for Iopamidol$^{(R)}$ and Dotarem. And MRI contrast agent was used for Primovist$^{(R)}$ and Gadovist$^{(R)}$. To obtain an image, we used CT scanner. With an obtained image, we set the $1cm^2$ region of interest in the middle of bottle to measure the noise and CT number. As a result, there was no difference in CT number before and after inserting $^{99m}Tc$ into all contrast media including Normal Saline. However, when it comes to Noise, there was a difference before and after inserting $^{99m}Tc$ into every contrast media except MRI contrast media such as Primovist$^{(R)}$ and Gadovist$^{(R)}$.

Effect of Cheunggansoyosan-gamibang on Hyperlipidemic mice (청간소요산가미방(淸肝逍遙散加味方)이 생쥐의 고지혈증에 미치는 영향)

  • Baek, Yong-Ju;Yang, Seung-Jung;Park, Hye-Sun;Kim, Kyoung-Su;Hong, Seok;Jeon, Sang-Yoon
    • Herbal Formula Science
    • /
    • v.14 no.1
    • /
    • pp.120-132
    • /
    • 2006
  • Hyperlipidemia is one of dangerous factors causing the arteriosclerosis. For the study of Cheunggansoyosan-gamibang( CGSYS) on antihyperlipidemic effect, we had fed mice divided to three groups (basal diet, hyperlipidemic diet, hyperlipidemic diet + CGSYS), and observed the change of weight, total cholesterol. triglyceride, HDL-cholesterol. LDL-cholesterol. sGOT, sGPT on the serum per every 7days for 6weeks. Also to compensate for the results above, we had tested rat liver. The results of this Study were obtained as fallows ; 1. Cholesterol change on blood was decreased by CGSYS. 2. Total cholesterol. triglyceride and LDL-cholesterol were significantly decreased by CGSYS. 3. HDL-cholesterol was significantly increasd by CGSYS. 4. sGPT was significantly decreased by CGSYS. 5. sGOT was not changed by CGSYS. 6. In case of supplying CGSYS. fatty degeneration was not observed in liver portal area. This study suggests that Cheunggansoyosan-gamibang was significant effect with hyperlipidemia.

  • PDF

Recurrent arteriovenous malformation on palate after embolization combined surgical resection: preoperative magnetic resonance features and intraoperative angiographic findings

  • Son, Yong-Hyun;Baik, Seung-Kug;Kang, Min-Su;Kim, Yong-Deok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.41 no.6
    • /
    • pp.346-351
    • /
    • 2015
  • Angiography is the gold standard for the diagnosis and complete resection of arteriovenous malformations (AVMs). The absence of residual AVM after surgery is commonly believed to reduce the risk of future hemorrhage. However, AVMs can recur after proven complete angiographic resection can occur, albeit rarely, especially in the pediatric population. We report a rare case of a recurrent AVM two years after complete resection in an adult patient. This case report shows that AVMs in adults can recur despite their rarity and despite postoperative angiography confirming complete removal. Moreover, in this case, the recurrent AVM involved a new feeding vessel that was not involved with the initial lesion.

Multidetector computed tomography in preoperative planning for temporomandibular joint ankylosis: A pictorial review and proposed structured reporting format

  • Singh, Rashmi;Bhalla, Ashu Seith;Manchanda, Smita;Roychoudhury, Ajoy
    • Imaging Science in Dentistry
    • /
    • v.51 no.3
    • /
    • pp.313-321
    • /
    • 2021
  • Ankylosis of the temporomandibular joint (TMJ) is a disabling disease resulting from fibrous or bony fusion of the mandibular condyle and the glenoid fossa. Early diagnosis and surgical treatment are essential to prevent facial deformity and other complications. Conventional radiography has limitations in demonstrating the true extent of ankylosis. It is important for surgeons to be aware of the size and degree of bony ankylosis in order to perform complete resection of the ankylotic mass. In addition, a detailed evaluation of the relationship with adjacent vital structures such as the internal maxillary artery, inferior alveolar nerve canal, external auditory canal, and skull base are crucial to avoid iatrogenic injury. Multidetector computed tomography (MDCT) is the current imaging modality of choice for preoperative assessments. Herein, the authors propose a structured CT reporting template for TMJ ankylosis to strengthen the value of the preoperative imaging report and to reduce the rates of intraoperative complications and recurrence.

Morphological variation of the velum in children and adults using magnetic resonance imaging

  • Kotlarek, Katelyn J.;Haenssler, Abigail E.;Hildebrand, Kori E.;Perry, Jamie L.
    • Imaging Science in Dentistry
    • /
    • v.49 no.2
    • /
    • pp.153-158
    • /
    • 2019
  • Purpose: The purpose of this study was to investigate variations in velar shape according to age, sex, and race using magnetic resonance imaging (MRI). Materials and Methods: The study sample consisted of 170 participants (85 children, 85 adults) between 4 and 34 years of age. Velar morphology was visually classified using midsagittal MRI scans for each participant by 2 independent raters. Inter- and intra-rater reliability was assessed. Statistical analyses were performed to identify correlations of velar shape with sex, age, and race. Results: The most frequent velar shape was "butt" for both adults(41%) and children (58%) in this study. The least common shapes for adults were "leaf" and "S." The children did not exhibit any "leaf" or "straight" velar shapes. A statistically significant difference was noted for age with respect to velar shape (P=0.014). Sex and race were found to have no significant impact on velar shape in this study. Conclusion: When using MRI to evaluate velar morphology, the "butt" shape was most common in both children and adults. Velar shape varied significantly with age, while race and sex did not have a significant impact.

Dose Measurements using Phantoms for Tube Voltage, Tube Current, Slice Thickness in MDCT (MDCT의 관전압, 관전류, 슬라이스 두께 변화에 따른 팬텀의 선량 분포 측정)

  • Lee, Chang-Lae;Jeon, Seong-Su;Nam, So-Ra;Cho, Hyo-Min;Jung, Ji-Young;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.139-143
    • /
    • 2007
  • The purpose of this study was to measure and evaluate radiation dose for MDCT parameters. Patient dose for various combination of MDCT parameters were experimentally measured, using MDCT (GE light speed plus 4 slice, USA), model 2026C electrometer (RADICAL 2026C, USA), standard Polymethylmethacrylate (PMMA) head and body CT dosimetry phantoms. In clinical situations, for a typical abdominal scan performed with MDCT at 120 kVp, 180 mAs, 20 mm collimation, and a pitch of 0.75 $CTDI_w,\;CTDI_{vol}$ were measured as 20.2 mGy, 26.9 mGy, respectively. When scan length is assumed as 271.3 mm, DLP and measured effective dose of the abdominal would be calculated as $729.1\;mGy{\cdot}cm$, 10.9 mSv, respectively.

  • PDF

Multidimensional Model for Assessing Risks from Occupational Radiation Exposure of Workers (직업상 피폭에 따른 방사선 위험성 평가를 위한 다차원적 모델)

  • Bae, Yu-Jung;Kim, Byeong-soo;Gwon, Da-yeong;Kim, Yong-min
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.555-564
    • /
    • 2017
  • The current radiation risk assessment for occupational exposure is based on the measured exposure dose and health checkups of workers. This people-centered risk assessment may occur errors because absence of using personal dosimeter or unrelated health symptoms of individuals lead to difficulties in obtaining accurate data from workers. In addition, although the established legal upper dose limit was used as a reference for the assessment, it does not imply that this limit is the optimal dose of radiation workers should get; ALARA principle should always be appreciated. Therefore, a new risk assessment model that can take account of all the important factors and implement optimization of radiation protection is required at the national level. In this paper, based on the KOSHA Risk Assessment, we studied on the workplace-centered risk assessment model for radiation field rather than the people-centered. The result of the study derived a right model for radiation field through the analysis of the risk assessment methods in various fields and also found data acquisition methods and procedures for applying to the model. Multidimensional model centering on the workplace will enables more accurate radiation risk assessment by using a risk index and radar plot, and consequently contribute to the efficient worker management, preemptive worker protection and implementation of optimization of radiation protection.

A Study on Knowledge and Acceptance of Irradiated Food -Department of Radiological science, Food and Biotechnology- (방사선 조사식품에 대한 인지도 및 수용도에 관한 연구 -방사선학과, 식품생물공학과-)

  • Kim, Kee-Bog
    • Journal of the Korean Society of Radiology
    • /
    • v.1 no.1
    • /
    • pp.5-10
    • /
    • 2007
  • A survey was conducted to examine the major that is Radiological, Food and Biotechnology in S city of the Chung nam by the self-administered questionnaire. Data was collected total of 208 participants with the 93 male subjects and 115 female subjects The results of this study can be summarized as follows; 1. Out of 208 subjects participants with the 81 subjects(38.9%) was answered that I was knowed of the food irradiation, the greater part of the Food and Biotechnology wasn't know, 32 subjects(15.4%) of the respondents to the Radiological science did extremely much know. 2. If one of the an institution or organization of the most trustworthy scientific investigation proved willingly make a purchase to use irradiated food. the acceptance of irradiated food significantly decreased the mean scores of concern about a sex and grade(P<0.204, P<0.418). 3. Recently the government doing to prevented spreading of food poisoning accidents by school lunch, out of 204 subjects with 18 subjects(8.8%) is very required, with the 87 subjects(42.6%) is generally required, therefore total of 105 subjects(51.5%) is a positive answer, there was statistical significantly increased very association between necessity of food irradiated and planing of the government follow-up measures(P<0.009).

  • PDF

Actual condition on accuracy control of mammography equipment in Kyeongsangbuk-do (경상북도 유방촬영장비의 정도관리에 대한 실태조사)

  • Kim, Sang-Jin;Ji, Tae-Jeong
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.29-37
    • /
    • 2006
  • The breast cancer has the highest occurrence rate among the female cancers, and as the living style changes, the occurrence is increasing gradually. For the breast cancer test among women, who comprises up to 50% of the total population, the mammography is mainly used as the screening test, and the accuracy control is the most important aspect of the testing. Therefore this research divided the northern part of Kyeongsangbuk-do into 4 regions and investigated the accordance ratio of examination field and light examination field, the total focus using the optical density and compression rate, and the overall maintenance of mammography within the regions. The equipments of 11 hospitals were investigated, and the 7 hospitals passed the standard level of the accordance ratio of examination field. 6 hospitals passed the standard optical density, and 7 hospitals had the passing performance in the compression rate. Fibers, group of specks, and masses within the Mammographic Accreditation Phantom scored 10, being within the standard range. However, only 3 hospitals were equipped with private development processor and illumination. The result reflects the fact that the image quality of breast is not correctly being maintained. Moreover, only 27.27% satisfied all the three categories of compression fitting, accordance ratio of examination field, and phantom image evaluation at the same time. The accuracy control must be maintained more precisely for the accurate diagnosis of breast cancer.

  • PDF