• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.034 seconds

Correlation between the Seoul Neuropsychological Screening Battery of the Parkinson's Disease Patient with Mild Cognitive Impairment and Change of the Cerebral Ventricle Volume in the Brain MRI (경도인지장애를 동반한 파킨슨병 환자의 서울신경심리검사와 뇌 자기공명영상에서 뇌실 체적 변화에 대한 상관관계)

  • Lee, Hyunyong;Kim, Hyeonjin;Im, Inchul;Lee, Jaeseung
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.5
    • /
    • pp.231-240
    • /
    • 2014
  • The purpose of this study were to analyze that the Seoul neuropsychological screening battery (SNSB) for the evaluating cognitive assessment of the Parkinson's disease patients with mild cognitive impairment (PD-MCI) and the changes of the cerebral ventricle volume in the brain magnetic resonance imaging (MRI), and we has been bring forward the guideline to determine the diagnostic criteria for the PD-MCI. To achieve this, we was diagnosed with Parkinson's disease patients (PD-MCI group: 34 patients; Parkinson's disease with normal cognition, PD-NC group: 34 patients) to perform the SNSB test for the attention, language, memory, visuospatial, and frontal/executive functions and the brain MRI. Additionally, to compared the change of the cerebral ventricle volume, we performed the brain MRI for the 32 normal control (NC) group. The volumetric analysis for a specific cerebral ventricle performed by using Freesurfer Ver. 5.1 (Massachusetts general Hospital, Boston MA, USA). As a results, compared to the PD-NC group, the PD-MCI group were statistically significant reduction in the ability to perform the memory and the visuospatial function (p<0.05). The volumetric changes for a specific cerebral ventricle were statistically significant variation in the left and right lateral ventricle, left and right inferior lateral ventricle, and 3rd ventricle. Although, in order to compared the objectification, the normalized percentage applied to the volumetric changes showed to extend the PD-MCI group than the PD-NC group. Specially, the left and right ventricle extension for the PD-MCI patients conspicuously had showed a quantitative linear relationship between the memory and the visuospatial function for the SNSB (r>0.5, p<0.05). Therefore, we were able to judge the diagnostic criteria of the PD-MCI through that can observe the volumetric variation of the specific cerebral ventricle by using Freesurfer in brain MRI, and to analyze the correlation between the SNSB.

A Study on the Diagnostic Reference Level of Skull Radiography in Digital Radiography (디지털 방사선 환경에서 두부 방사선검사 시 진단참고수준 검사조건에 대한 고찰)

  • Yeon-Jin, Jeong;Young-Cheol, Joo;Dong-Hee, Hong;Sang-Hyeon, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.897-904
    • /
    • 2022
  • The purpose of this study is to compare the difference in dose and image quality when applying the diagnostic reference level (DRL) test conditions for head radiography in a digital radiation environment and the test conditions currently applied in clinical practice. I would like to review the conditions of radiographic examination. In this study, the head model phantom was targeted, and the investigation conditions were divided into clinical conditions (Clinic), DRL value (DRL75), and DRL average value (DRLmean). For dose, Enterance surface dose (ESD) was measured, and for image quality, signal-to-noise ratio and contrast-to-noise ratio were measured and analyzed for comparison. The average values of skull anterior posterior(AP) ESD according to the changes in test conditions were Clinic 1214.03±4.21 µGy, DRL75 3017.83±8.14 µGy, DRLmean 2283.50±7.09 µGy, and skull lateral (Lat). The average value of ESD was statistically significant with Clinic 762.79±3.54 µGy, DRL75 2168.57±10.83 µGy, and DRLmean 1654.43±6.48 µGy (p<0.01). The average values of SNR and CNR measured in the orbital, maxillary sinus, frontal sinus, and sella turcica were statistically significant (p<0.01). As a result of this study, compared to DRL, the conditions used in clinical practice showed lower dose levels of about 58% for AP and about 70% for Lat., and there was no qualitative difference in terms of image quality. Through this study, it is necessary to consider a new diagnostic reference level suitable for the digital radiation environment, and it is considered that the dose should be reduced accordingly.

The Influences of Bowel Condition with Lumbar Spine BMD Measurement (요추부 골밀도 측정 시 장내 변화가 골밀도에 미치는 영향)

  • Yoon, Joon;Kim, Yun-Min;Lee, Hoo-Min;Lee, Jung Min;Kwon, Soon-Mu;Cho, Hyung-Wook;Kang, Yeong-Han;Kim, Boo-Soon;Kim, Jung-Soo
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.273-278
    • /
    • 2014
  • Bone density measurement use of diagnosis of osteoporosis and it is an important indicator for treatment as well as prevention. But errors in degree of precision of BMD can be occurred by status of patient, bone densitometer and radiological technologist. Therefore the author evaluated that how BMD changes according to the condition of the patient. As Lumbar region, which could lead to substantial effects on bone density by diverse factors such as the water, food, intentional bowels. We recognized a change of bone mineral density in accordance with the height of the water tank and in the presence or absence of the gas using the Aluminum Spine Phantom. We also figured out the influence of bone mineral density by increasing the water and food into a target on the volunteers. Measured bone mineral density through Aluminum Spine Phantom had statistically significant difference accordance with increasing the height of water tank(p=0.026). There was no significant difference in BMD according to the existence of the bowl gas(p=0.587). There was no significant difference in a study of six people targeted volunteers in the presence or absence of the food(p=0.812). And also there was no significant difference according to the existence of water(p=0.618). If it is not difficult to recognize the surround of bone in measuring BMD of lumbar bone, it is not the factor which has the great effect on bone mineral density whether the test is after endoscopic examination of large intestine and patient's fast or not.

The Effect of Memory Load on Maintenance in Face and Spatial Working Memory: An Event-Related fMRI Study (기억부하가 얼굴과 공간 작업기억의 유지에 미치는 효과: 사건유관 fMRI 연구)

  • Kim, Jung-Hee;Jeong, Gwang-Woo;Kang, Heoung-Keun;Lee, Moo-Suk;Park, Tae-Jin
    • Korean Journal of Cognitive Science
    • /
    • v.21 no.2
    • /
    • pp.359-386
    • /
    • 2010
  • In order to evaluate the domain-specific model and process-specific model of spatial and nonspatial working memory (WM), this study manipulated the memory load of the delayed response task and examined how the neural correlates of memory load effect was influenced by the stimulus domain (face and location) at the maintenance stage of WM using an event-related fMRI experiment. One or three face stimuli were presented as target stimuli and participants were asked to maintain the face itself (face WM) or the location of face stimuli (spatial WM). The results of recognition judgment accuracy showed no difference between face WM and spatial WM, and showed equivalent memory load effects of both WM. As a result of brian image analysis, memory load effect at maintenance stage showed that inferior, middle, and superior PFC were recruited by both face WM and spatial WM, and showed that VLPFC was the commonly activated area by both WM, supporting functional specialization of PFC by process components of WM. This study provides evidence for process-specific model in which maintenance of WM is associated with VLPFC.

  • PDF

Comparative Analysis of pre and Post Digital X-ray Equipment Construction and Web-Based Wireless Network Environment Construction for Medical Screening Vehicles (Digital X-ray장비 구축 검진차량의 웹 기반 무선 네트워크 환경 구축 전과 후의 비교분석)

  • Ryu, Young-Hwan;Kweon, Dae-Cheol;Goo, Eun-Hoe;Dong, Kyung-Rae;Choi, Sung-Hyun;Jang, Young-Ill
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.103-111
    • /
    • 2010
  • A total of 200 hospital employees participated in this study from January 2009 to June 2010. For the survey, each participant was given necessary items for external health exams. Cronbach's alpha was calculated for the survey regarding wireless networks. There was a need for educating data processing workers in the medical field regarding fundamental information prior to wireless network construction. The reason is high scores would be collected, which would reflect knowledge regarding data processing used at hospitals and the differences between paper charts and electronic charts. However, low scores were obtained which reflected knowledge regarding the differences between wired and wireless networks and Mini-PACS. Time for each patient was shortened to a maximum of three minutes and minimum of one minute for treatment and transmitting medical images when comparing pre and post wireless network construction(p < 0.01). Scores from the pre and post construction survey increase 1.98, 1.65, and 1.43 points for activity in the health screening area, usage of space in the health screening vehicle, and patient information storage respectively(p < 0.05). The number of patients receiving external health screenings twelve times was 3,655 prior to construction of a wireless network system. However, the number increased to 4,265 after construction. The increasing percentage was 17% in total. Prior to construction, X-ray images were taken 527 times, but after construction of a wireless network, this number growed to 1,194 and it was 116% increase. The loss of patient's medical treatment charts was reduced from 19.8% to 18.7% after construction. We believe that educating medical workers on Mini-PACS and Mini-OCS Systems will not only increase their efficiency but also make patients receiving better treatment.

  • PDF

A study of Curved Dosimeter for Flattening Filter Free Beam Quality Assurance Evaluation using Curved Dosimeter in Radiotherapy (Flattening Filter Free Beam의 정도관리를 위한 곡면선량계 가능성 연구)

  • Han, Moojae;Shin, Yohan;Jung, Jaehoon;Heo, Seunguk;Kim, Kyotae;Heo, Yeji;Cho, Heunglae;Park, Sungkwang
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.119-124
    • /
    • 2019
  • Radiation therapy using flattening filter free beam can prevent beam attenuation caused by flattening filter and can improve treatment efficiency. However, accurate dose control is not established for nonuniform iso dose distributions. In this study, curved dosimeter based on photoconductive material $HgI_2$ was fabricated and its reproducibility and linearity were evaluated at 6 MV photon energy to verify its performance. In order to show the usefulness of the curved measurement, the signals measured on the flat substrate and the curved substrate were compared in the flattening filter free beam using the acrylic filter. As a result, the reproducibility of the unit cell dosimeter was evaluated as SE 0.613%, and the linearity was evaluated as R-sq 0.9999. The usability evaluation of the array curve dosimeter demonstrated its usefulness by indicating a curvature error rate of 11.073%p and a reduced error rate.

Clinical Outcomes and Cost-Effectiveness of Osteoporosis Screening With Dual-Energy X-ray Absorptiometry

  • Chiao-Lin Hsu;Pin-Chieh Wu;Chun-Hao Yin;Chung-Hwan Chen;King-Teh Lee;Chih-Lung Lin;Hon-Yi Shi
    • Korean Journal of Radiology
    • /
    • v.24 no.12
    • /
    • pp.1249-1259
    • /
    • 2023
  • Objective: This study aimed to evaluate the clinical outcomes and cost-effectiveness of dual-energy X-ray absorptiometry (DXA) for osteoporosis screening. Materials and Methods: Eligible patients who had and had not undergone DXA screening were identified from among those aged 50 years or older at Kaohsiung Veterans General Hospital, Taiwan. Age, sex, screening year (index year), and Charlson comorbidity index of the DXA and non-DXA groups were matched using inverse probability of treatment weighting (IPTW) for propensity score analysis. For cost-effectiveness analysis, a societal perspective, 1-year cycle length, 20-year time horizon, and discount rate of 2% per year for both effectiveness and costs were adopted in the incremental cost-effectiveness (ICER) model. Results: The outcome analysis included 10337 patients (female:male, 63.8%:36.2%) who were screened for osteoporosis in southern Taiwan between January 1, 2012, and December 31, 2021. The DXA group had significantly better outcomes than the non-DXA group in terms of fragility fractures (7.6% vs. 12.5%, P < 0.001) and mortality (0.6% vs. 4.3%, P < 0.001). The DXA screening strategy gained an ICER of US$ -2794 per quality-adjusted life year (QALY) relative to the non-DXA at the willingness-to-pay threshold of US$ 33004 (Taiwan's per capita gross domestic product). The ICER after stratifying by ages of 50-59, 60-69, 70-79, and ≥ 80 years were US$ -17815, US$ -26862, US$ -28981, and US$ -34816 per QALY, respectively. Conclusion: Using DXA to screen adults aged 50 years or older for osteoporosis resulted in a reduced incidence of fragility fractures, lower mortality rate, and reduced total costs. Screening for osteoporosis is a cost-saving strategy and its effectiveness increases with age. However, caution is needed when generalizing these cost-effectiveness results to all older populations because the study population consisted mainly of women.

A cone-beam computed tomography evaluation of buccal bone thickness following maxillary expansion

  • Akyalcin, Sercan;Schaefer, Jeffrey S.;English, Jeryl D.;Stephens, Claude R.;Winkelmann, Sam
    • Imaging Science in Dentistry
    • /
    • v.43 no.2
    • /
    • pp.85-90
    • /
    • 2013
  • Purpose: This study was performed to determine the buccal alveolar bone thickness following rapid maxillary expansion (RME) using cone-beam computed tomography (CBCT). Materials and Methods: Twenty-four individuals (15 females, 9 males; 13.9 years) that underwent RME therapy were included. Each patient had CBCT images available before (T1), after (T2), and 2 to 3 years after (T3) maxillary expansion therapy. Coronal multiplanar reconstruction images were used to measure the linear transverse dimensions, inclinations of teeth, and thickness of the buccal alveolar bone. One-way ANOVA analysis was used to compare the changes between the three times of imaging. Pairwise comparisons were made with the Bonferroni method. The level of significance was established at p<0.05. Results: The mean changes between the points in time yielded significant differences for both molar and premolar transverse measurements between T1 and T2 (p<0.05) and between T1 and T3 (p<0.05). When evaluating the effect of maxillary expansion on the amount of buccal alveolar bone, a decrease between T1 and T2 and an increase between T2 and T3 were found in the buccal bone thickness of both the maxillary first premolars and maxillary first molars. However, these changes were not significant. Similar changes were observed for the angular measurements. Conclusion: RME resulted in non-significant reduction of buccal bone between T1 and T2. These changes were reversible in the long-term with no evident deleterious effects on the alveolar buccal bone.

The Radiation Safety Management in the Animal Hospital Using Inspection Standard of Diagnosis Radiation System (진단용 방사선발생장치의 검사기준을 적용한 동물병원의 방사선 안전관리)

  • Kim, Sang-Woo;Rhim, Jea-Dong;Han, Dong-Kyoon;Seoung, Youl-Hun
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.73-80
    • /
    • 2010
  • The purpose of this study was to investigate the actual conditions of radiation safety supervision in animal clinics using inspection standard of X-ray generator for diagnosis. The surveys for inspection standard system, equipment condition, and safety supervision were carried out in 18 animal clinics randomly. The inspection standard included reproducibility of dose exposure, kVp, mAs, collimator accuracy test, collimator luminance test, X-ray view box luminance test, grounding system equipment test and external leakage current test. The surveys of equipment condition and safety supervision used one-on-one interview with 5 points measurement. As a result, 44.44% of reproducibility of dose exposure was proper, 81.25% of kVp test was good, and 100% of mAs test was appropriate. Also, 66.66% of collimator accuracy test was proper, 61.11% of collimator luminance test was good, 53.13% of X-ray view box luminance test was suitable. In addition, only 5.55% of grounding system equipment and ground resistance was proper, 63.64% of external leakage current test was appropriate in grounding system equipment test. The 100mA electric capacity of X-ray generator for diagnosis was popular with 44.44%, and its 55.56% was purchased used equipment. Monthly average of less than 50 times (61.11%) was top frequency in use, and no animal clinic had a thermo-luminescence dosimeter(TLD). The 16 animal clinics with radiation safety zone and 2 without radiation safety zone were appeared.

The Prevalence of Thyroid Nodules and the Morphological Analysis of Malignant Nodules on Ultrasonography (갑상선 결절 유병률과 초음파 영상에서 악성소견 결절의 형태학적 분석)

  • An, Hyun;Ji, Tae-jeong;Lee, Hyo-young;Im, In-chul
    • Journal of radiological science and technology
    • /
    • v.42 no.3
    • /
    • pp.201-207
    • /
    • 2019
  • The purpose of this study was to evaluate the prevalence of thyroid nodules and malignant findings of thyroid nodules in 1,954 patients (654 males and 1,300 females) aged 20 years or older who underwent thyroid ultrasound from January 2018 to December 2018. Examination of the thyroid gland was performed, and fine needle aspiration cytology was performed on the thyroid nodule. As a result, 108 (16.5%) out of 654 males and 368 (28.3%) out of 1,300 females showed higher prevalence than males. The prevalence of single nodules and multiple nodules in gender and age groups was significantly higher for women and for ages (male p=.001, female p=.001). There was a significant difference in males in the nodule size (p=.001) and no significant difference in females (p=.069). Fine - needle aspiration cytology of 476 patients with nodules was diagnosed as malignant in 46 patients (9.6%). Based on pathologic results, 383 benign and 93 malignant groups were analyzed. Ultrasonographic findings were as follows single nodule (p=.000), solid(p=.004), hypoechoic (p=.000), ill-defined peripheral boundary (p=.000), and calcification (p=.000), respectively. In the diagnosis of thyroid nodule, primary ultrasonographic findings through morphological classification of the nodules may reduce indiscriminate fine needle aspiration cytology in benign and malignant nodules.