• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.027 seconds

Clinical Practice Guidelines for Gastric Cancer in Korea: An Evidence-Based Approach

  • Lee, Jun Haeng;Kim, Jae G.;Jung, Hye-Kyung;Kim, Jung Hoon;Jeong, Woo Kyoung;Jeon, Tae Joo;Kim, Joon Mee;Kim, Young Il;Ryu, Keun Won;Kong, Seong-Ho;Kim, Hyoung-Il;Jung, Hwoon-Yong;Kim, Yong Sik;Zang, Dae Young;Cho, Jae Yong;Park, Joon Oh;Lim, Do Hoon;Jung, Eun Sun;Ahn, Hyeong Sik;Kim, Hyun Jung
    • Journal of Gastric Cancer
    • /
    • v.14 no.2
    • /
    • pp.87-104
    • /
    • 2014
  • Although gastric cancer is quite common in Korea, the treatment outcome is relatively favorable compared to those in western countries. However, there are currently no Korean multidisciplinary guidelines for gastric cancer. Experts from related societies developed guidelines de novo to meet Korean circumstances and requirements, including 23 recommendation statements for diagnosis (n=9) and treatment (n=14) based on relevant key questions. The quality of the evidence was rated according to the GRADE evidence evaluation framework: the evidence levels were based on a systematic review of the literature, and the recommendation grades were classified as either strong or weak. The applicability of the guidelines was considered to meet patients' view and preferences in the context of Korea. The topics of the guidelines cover diagnostic modalities (endoscopy, endoscopic ultrasound, and radiologic diagnosis), treatment modalities (surgery, therapeutic endoscopy, chemotherapy, and radiotherapy), and pathologic evaluation. An external review of the guidelines was conducted during the finalization phase.

A study on the usefulness of a fusion model designed cloak shield to reduce the radiation exposure of the assistant during CT of severely injured patient (중증외상환자 CT 검사 시 검사보조자의 방사선피폭 경감을 위한 융합적 망토 차폐체의 유용성 연구)

  • Seo, Sun-Youl;Han, Man-Seok;Kim, Chang-Gyu;Jeon, Min-Cheol;Kim, Yong-Kyun;Kim, Gab-Jung
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.9
    • /
    • pp.211-216
    • /
    • 2017
  • The purpose of this study is to evaluate the usefulness of a newly fusion model designed cloak shield to reduce the radiation exposure of the assistant during CT(computed tomography) of severely injured patient. Radiation dose was measured in the heart, both axillary and thyroid areas using newly designed cloak shield and existing shield with head phantom and human phantom under the same conditions as brain vascular CT scan. The newly designed cloak shield was measured higher for radiation shielding rate than the existing shields, 61.9 % for heart, 46.2 % for left axillary, 69.8 % for right axillary and 71.1 % for thyroid gland, respectively. a newly developed fusion model of cloak shields are useful for reducing radiation exposure. It is expected to make a significant contribution to reduction of radiation exposure.

Relationship between Hospital Safety Symbol Shapes and Memory (병원 안전 심볼의 형태와 기억과의 관계)

  • Seok-Hwan Bae;Myung-Chul Park;Jae-Sang You;Yong-Gwon Kim;Cheul-Ho Ryoo;Dong-Hyun Oh
    • Journal of radiological science and technology
    • /
    • v.46 no.2
    • /
    • pp.115-122
    • /
    • 2023
  • The purpose of this study was to examine the association between the shapes and colors of emergency exit symbols, magnetic field warning symbols, and radiation zone symbols used in hospitals for staff and patient safety and their effects on cognitive memory. The hippocampal region's signal intensity(SI) was analyzed using fMRI. The Symbol 2 (1.75±0.54) with a green background had the highest signal intensity (SI) for emergency exits, according to the findings. The black symbol 2 (1.60±0.51) with a yellow background had the highest signal intensity (SI) for the magnetic field warning symbol, followed by the black symbol 1 (1.59±0.65) with an orange background. The black symbol 2 (1.59±0.59) with a yellow background and the black symbol 3 (1.58±0.52) with an orange background had the low signal intensity with slight differences as for the radiation zone symbols. In conclusion, it was determined that the signal intensity of the black symbol with a yellow background was the highest in the magnetic field area and radiation area. This implies that symbols with a high signal intensity (SI) must be utilized intensively. To ensure that the correct meaning of the symbols is communicated in the future, they must also be utilized regularly and continually in disaster safety education.

Preliminary Results of Tissue-Equivalent Proportional Counter (TEPC) Dosimeter for Measuring In-Situ Aviation Radiation

  • Nam, Uk-won;Park, Won-kee;Hwang, Junga;Sohn, Jongdae;Moon, Bongkon;Kim, Sunghwan
    • Journal of Astronomy and Space Sciences
    • /
    • v.37 no.4
    • /
    • pp.249-255
    • /
    • 2020
  • We develop the tissue-equivalent proportional counter (TEPC) type's space radiation dosimeter to measure in-situ aviation radiation. That was originally developed as a payload of small satellite in the low-earth orbit. This dosimeter is based on a TEPC. It is made of an A-150 tissue-equivalent plastic shell of an internal diameter of 6 cm and a thickness of 0.3 cm. TEPC is filled with pure propane at 13.9 torrs to simulate a cell diameter of 2 ㎛. And the associated portable and low power electronics are also implemented. The verification experiments have been performed by the calibration experiments at ground level and compared with Liulin observation at aircraft altitude during the flight between Incheon airport (ICN) and John F. Kennedy airport (JFK). We found that the TEPC dosimeter can be used as a monitor for space radiation dosimeter at aviation altitude based on the verification with Liulin observation.

Structural and Resting-State Brain Alterations in Trauma-Exposed Firefighters: Preliminary Results (외상에 노출된 소방관들의 뇌 구조 및 휴식기 뇌기능 변화: 예비 결과)

  • Yae Won Park;Suhnyoung Jun;Juwhan Noh;Seok Jong Chung;Sanghoon Han;Phil Hyu Lee;Changsoo Kim;Seung-Koo Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.3
    • /
    • pp.676-687
    • /
    • 2020
  • Purpose To analyze the altered brain regions and intrinsic brain activity patterns in trauma-exposed firefighters without posttraumatic stress disorder (PTSD). Materials and Methods Resting-state functional MRI (rsfMRI) was performed for all subjects. Thirty-one firefighters over 40 years of age without PTSD (31 men; mean age, 49.8 ± 4.7 years) were included. Twenty-six non-traumatized healthy controls (HCs) (26 men; mean age, 65.3 ± 7.84 years) were also included. Voxel-based morphometry was performed to investigate focal differences in the brain anatomy. Seed-based functional connectivity analysis was performed to investigate differences in spontaneous brain characteristics. Results The mean z-scores of the Seoul Verbal Learning Test for immediate and delayed recall, Controlled Oral Word Association Test (COWAT) score for animals, and COWAT phonemic fluency were significantly lower in the firefighter group than in the HCs, indicating decreased neurocognitive function. Compared to HCs, firefighters showed reduced gray matter volume in the left superior parietal gyrus and left inferior temporal gyrus. Further, in contrast to HCs, firefighters showed alterations in rsfMRI values in multiple regions, including the fusiform gyrus and cerebellum. Conclusion Structural and resting-state functional abnormalities in the brain may be useful imaging biomarkers for identifying alterations in trauma-exposed firefighters without PTSD.

In vivo optical coherence tomographic imaging to monitor gingival recovery and the adhesive interface in aesthetic oral rehabilitation: A case report

  • Graca, Nathalia Del Rio Lyra;Palmeira, Anna Rebeca de Barros Lins Silva;Fernandes, Luana Osorio;da Silva Pedrosa, Marlus;Guimaraes, Renata Pedrosa;Santos, Saulo Cabral dos;Gomes, Anderson Stevens Leonidas;da Silva, Claudio Heliomar Vicente
    • Imaging Science in Dentistry
    • /
    • v.49 no.2
    • /
    • pp.171-176
    • /
    • 2019
  • The available methods for veneer evaluation are limited to clinical and radiographic examinations, which may not allow the appropriate identification of failure. In this report, we demonstrate the use of optical coherence tomography (OCT) as a noninvasive diagnostic and follow-up method to evaluate gingival recovery and the adhesive interface in aesthetic oral rehabilitation involving periodontal plastic surgery and ceramic laminate veneers. OCT was efficient for evaluating both soft and hard tissues, as well as the quality of the adhesive interface. In conclusion, OCT was found to be a promising approach for the professional evaluation of aesthetic oral rehabilitation, as it was capable of generating images that enabled the analysis of gingival recovery and the adhesive interface.

Beyond the mouth: Uncovering non-secretory multiple myeloma through oral symptoms

  • Pedro Henrique Chaves Isaias;Fabio Wildson Gurgel Costa;Pedro Henrique Goncalves Holanda Amorim;Raul Anderson Domingues Alves da Silva;Fabrício Bitu Sousa;Karuza Maria Alves Pereira;Ana Paula Negreiros Nunes Alves;Mario Rogério Lima Mota
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.211-220
    • /
    • 2024
  • Non-secretory multiple myeloma (NSMM) is a rare cancer of plasma cells characterized by the absence of detectable monoclonal M protein in the blood or urine. A 57-year-old woman presented with mandibular pain but without intraoral swelling. Imaging studies revealed multiple osteolytic lesions in her mandible and pronounced root resorption of the left mandibular second molar. Biopsy results showed atypical plasmacytoid cells positive for anti-kappa, CD138, MUM1, and CD79a antibodies, but negative for anti-lambda and CD20. These results were indicative of a malignant plasma cell neoplasm. No abnormalities were revealed by free light chain assay or by serum or urine protein electrophoresis, leading to a diagnosis of NSMM. The patient began chemotherapy in conjunction with bisphosphonate therapy and achieved remission following treatment. This case underscores the critical role of dentists in the early detection and prevention of NSMM complications, as the disease can initially present in the oral cavity.

Usefulness Comparative Experimental Study of the CT and MR Imaging in the Dog Clonorchiasis (잡견 간흡충증의 전산화단층촬영과 자기공명영상의 유용성에 관한 실험적 연구)

  • Goo, Eun-Hoe;Kweon, Dae-Cheol;Kim, Dong-Sung;Choi, Chun-Kyu
    • Journal of radiological science and technology
    • /
    • v.26 no.3
    • /
    • pp.33-39
    • /
    • 2003
  • Purpose : Be aware of clinical possibilities on image quality by comparison of contrast-enhanced dynamic CT and MR imaging applied of MIP technique after the experimentally induced clonorchasis infection in dogs. Materials and Method : Twenty mongrel dogs prepared in zoo-laboratory were followed up with serial CT scans and MR imaging for 13 weeks after the experimental infection in liver. Two-phase helical CT was acquired in the supine position with the following scanning parameters. After the injection of contrast material, the arterial phase was initiated using a bolus-racking method. The portal phase scan was started 15 seconds after the arterial phase scan. CT protocol was determined after single level dynamic scans. MR imaging used the CP body coil and images get a 2D image using HASTE, FLASH, TSE pulse sequence. Bile duct MR imaging were obtained in three plans. Then each image was post processed by using target MIP algorithm. Two experimentation above, as a method of evaluation, one pathologist, three radiologist and five radiological technologist were analyzed visually for evaluation of following findings, enhancement of the bile duct wall, dilatation of bile duct tip, liver parenchyma, background suppression. Results : Five dogs was died of a disease after the infection, the rest one else shows the chronic dilatation of the intrahepatic bile duct with CT and MR imaging. Contrast administration of CT shows the contrast-enhanced of the bile duct walls with live parenchyma. MR imaging calculated of CNR and CR from pulse sequence for comparative evaluation and shows the pattern of the intrahepatic bile duct, dilatation of bile duct tip using MIP technique. CNR of the clonorchiasis, HASTE was $16{\pm}0.83$, TSE $7.06{\pm}3.0$, FLASH $1.19{\pm}0.2$ and CR, HASTE was 73.3%, TSE 62.3%, FLASH 6.4%. Conclusion : CT and MR imaging is very usefulness in diagnosis of dog clonorchiasis.

  • PDF

Evaluation of the Usefulness of a Wireless Signal Device for the Use of Contrast Agent in Computed Tomography (전산화단층촬영에서 조영제 주입에 따른 무선신호기 사용의 유용성평가)

  • Hong, Ki-Man;Jung, Myo-Young;Seo, Young-Hyun;Song, Jong-Nam
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.417-425
    • /
    • 2018
  • The psychological anxiety of radiologists, as well as the patients, is growing with the increasing use of CT contrast agent side effects and the process of extravasation. In this study, a satisfaction survey was conducted regarding the wireless signal device after CT examination in patients and radiologists by employing a wireless signal device during a contrast-enhanced CT examination in order to determine its usefulness to the relieve psychological anxiety, such as anxiety and fear, of patients and radiologists when using contrast agents. The use of a wireless signal device was also intended to help radiologists in dealing with the side effects of contrast agents that may occur during a CT examination and preventing extravasation. Patients aged 20 years or older, who visited the C university hospital in Jeonnam province for 4 months from August to November in 2017, were surveyed. A total number of 90 patients (57 males and 33 females),who agreed to the study after CT examination, were included in the questionnaire survey. Meanwhile, 15 radiologists, who were working at a CT room and had an experience in using a wireless signal device, were surveyed. Patient satisfaction was $6.01{\pm}0.88$ before the use of a wireless signal device and $8.20{\pm}1.06$ after use, thereby showing an increased satisfaction after its use. Radiologist satisfaction was $8.46{\pm}1.06$ after use, thereby not showing a big difference from the mean patient satisfaction. The satisfaction was high at over 8 points in both groups. The contribution to psychological stability with the use of a wireless signal device was $8.98{\pm}0.65$ in patients with prior experience of side effects and $8.00{\pm}1.21$ in patients without prior experience of side effects. In conclusion, it is considered to improve satisfaction with the examination by helping the radiologists in taking immediate action with calling via the wireless signal device and providing the patients and radiologists with psychological stability by reducing their anxiety.

A Study of The Correlation of The Area Dose with Residual CT Contrast Media and MRI Contrast Media during The Use of General Imaging Automatic Exposure Control System (일반촬영 자동노출제어장치 사용 시 잔존 CT 조영제와 MRI 조영제에 따른 면적선량의 상관성 연구)

  • Hong, Chan-Woo;Park, Jin-Hun;Lee, Jung-Min;Seo, Young-Deuk
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.619-627
    • /
    • 2016
  • The purpose of this study is to investigate the effect of CT contrast agent and MRI contrast agent on the area dose in the body when using automatic exposure control system in general radiography. After making rectangular holes in the center of the abdominal thickness paraffin phantom, CT contrast agent and MRI contrast agent were respectively diluted with physiological saline solution for contrast medium dilution ratio of 10:0, 9:1, 8:2, 7:3, 6:4, 5:5, 4:6, 3:7, 2:8, 1:9, 0:10%. Each experiment was set to 78 kVp, 320 mA, which is the proper condition for KUB photography, and thereafter a total of 30 inspections were made for each dilution ratio using an automatic exposure control device, and the area dose corresponding to the dilution ratio of each contrast agent, Average comparison and correlation analysis were performed on the exposure index. As a result, the CT contrast agent and the MRI contrast agent appeared different in area dose according to the dilution ratio(p<0.05), and as the dilution ratio increased, the area dose increased for CT contrast agent and MRI contrast agent(P<0.05). In each test, the exposure index showed the manufacturer's recommendation of 200-800 EI value, and the exposure index and area dose increased as the area dose increased(p<0.05). In conclusion, CT contrast agent and MRI contrast agent confirmed to increase the area dose by general imaging test using all automatic exposure control device. Therefore, it is considered that it is necessary to perform it after the contrast medium has been excreted sufficiently when using usual imaging test after using the contrast agent in CT and MRI examination.