• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.031 seconds

Development of the Upper Wear Fixation Device for Chest AP X-ray Imaging on the Emergency Stretcher Bed (응급실 침대 위 흉부전후방향 엑스선 검사를 위한 상의고정장치 개발)

  • Lim, Woo-Taek;Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.45 no.3
    • /
    • pp.205-211
    • /
    • 2022
  • This study aimed to provide basic data for 3D printing in the medical health field by developing upper wear fixation device (UWFD), an auxiliary device for shortening chest AP examination time on emergency room beds and non-contact with patients. The standard of hooks was modeled according to the bed frame using the Autodesk Fusion 360. It was printed with Form2 (Formlabs, Somerville, MA, USA), as SLA (stereo lithography apparatus) method, and was washed and hardened using Form Wash and Form Cure. The completed UWFD conducted an online survey on 4 items of stability, convenience, availability, preference and general characteristics. The total stability average was 3.93±0.80, the total convenience average was 3.93±0.68, the total availability average was 4.01±0.89, and the total preference average was 3.80±1.08. This study was significant in suggesting improvements in the general X-ray examination process in the emergency room by designing and making aids to easily fixing the patient's top to the frame of the emergency bed while meeting promptness and non-contact with the patient.

Analysis of Factors Influencing Changes in Left Atrium and Left Ventricle Size in Adults (성인의 좌심방과 좌심실 크기변화에 미치는 영향 요인 분석)

  • Sun-Hwa Kim;Sung-Hee Yang
    • Journal of radiological science and technology
    • /
    • v.47 no.2
    • /
    • pp.125-135
    • /
    • 2024
  • This study analysed the factors that predict and influence heart disease through key indicators related to changes in left atrial and left ventricular size. Measurements recommended by the American Society of Echocardiography were used, and the influence of variables was assessed using multiple regression analysis. The results showed that left atrial volume index(LAVI) was significantly different by age, obesity, diabetes, hypertension, dyslipidaemia, and left ventricular relaxation dysfunction(p<0.05). Left ventricular mass index(LVMI) was significantly different according to age, body mass index, hypertension, diabetes, dyslipidaemia, and left ventricular relaxation dysfunction(p<0.05). Increases in LVMI and relative ventricular wall thickness(RWT) were associated with changes in LAVI(p<0.05). Age, systolic blood pressure, increased LAVI, and RWT influenced changes in LVMI, and left ventricular dysfunction was analysed as an influencing factor for both changes in LAVI and LVMI. Therefore, changes in left atrial and left ventricular size are indicators for early diagnosis and prevention of heart disease, and it is necessary to carefully observe structural changes in the heart and actively manage risk factors for the prevention and management of heart disease.

Comparison of Noise Power Spectrum in Measurements by Using International Electro-technical Commission Standard Devices in Indirect Digital Radiography (간접평판형 검출기에서 국제전자기술위원회 기준을 통한 잡음전력스펙트럼 비교 연구)

  • Min, Jung-Whan;Jeong, Hoi-Woun;Kim, Ki-Won;Kwon, Kyung-Tae;Jung, Jae-Yong;Son, Jin-Hyun;Kim, Hyun-Soo
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.457-462
    • /
    • 2018
  • The purpose of this study was to compare image quality of indirect digital radiography (IDR) system using the International Electro-technical Commission standard (IEC 62220-1), and to suggest the analysis of noise power spectrum (NPS) which were applied to IEC 62220-1 in medical imaging. In this study, Pixium 4600 (Trixell, France) which is indirect flat panel detector (FPD) was used. The size of image receptor (IR) is $7{\times}17$ inch (matrix $3001{\times}3001$) which performed 14bit processing and pixel pitch is $143{\mu}m$. In IEC standard, NPS evaluation were applied to RQA3, RQA5, RQA7 and RQA9. Because of different radiation quality, each region of interesting (ROI) were compared. The results of NPS indicated up to $3.5mm^{-1}$ including low Nyquist frequency. RQA5 indicated the lowest NPS and the others indicated higher NPS results relatively. NPS result of ROI a38 was higher than ROI a92 and this result indicated that there are more noise in left (cathode) than right (anode). This study were to evaluate NPS by using different radiation quality and setting the each ROI, and to suggest the quantitative methods of measuring NPS.

Stenotrophomonas maltophilia and Ventilator-Associated Pneumonia in Critically Ill Pediatric Patients: a Retrospective Analysis at a Single Center (소아 환자에서 Stenotrophomonas maltophilia와 인공 환기요법 관련 폐렴에 관한 연구)

  • Lee, Byung-Kee;Choi, Soo-Han;Kim, Soo Jin;Cho, Joong Bum;Ae, Hong;Yoo, So-young;Kim, Ji Hye;Lee, Nam Young;Kim, Yae-Jean
    • Pediatric Infection and Vaccine
    • /
    • v.22 no.2
    • /
    • pp.75-80
    • /
    • 2015
  • Purpose: Ventilator-associated pneumonia (VAP) is a serious threat in critically ill pediatric patients. Data regarding Stenotrophomonas maltophilia VAP in pediatric population is limited. We evaluated the clinical data of S. maltophilia associated VAP in critically ill pediatric patients. Methods: A retrospective chart review was performed in pediatric patients 18 years old or younger who developed S. maltophilia associated VAP at Samsung Medical Center, Seoul Korea from January 2008 to December 2012. Results: A total of 31 patients were identified S. maltophilia associated VAP. Median age was 8 months (range, 0.5 month to 16.6 years) and 13 patients were male (40.6%). Underlying illnesses were cardiologic diseases (n=11, 34.4%), hematologic oncologic malignancies (n=7, 25%), neurologic diseases (n=4, 12.5%), pulmonary diseases (n=3, 9.4%), and others (n=4, 12.5%). The median duration of ventilator use before S. maltophilia VAP diagnosis was 14 days (range, 4-256 days). Overall mortality at 30 days was 12.5% (4/32). Conclusions: S. maltophilia should be also considered as a possible pathogen for VAP in critically ill pediatric patients. Empiric antibiotic choice should include agents that are active against S. maltophilia in patients who are deteriorating on broad spectrum beta-lactam antimicrobial agents.

Evaluation of Patient Radiation Doses Using DAP Meter in Interventional Radiology Procedures (인터벤션 시술 시 면적선량계를 이용한 환자 방사선 선량 평가)

  • Kang, Byung-Sam;Yoon, Yong-Su
    • Journal of radiological science and technology
    • /
    • v.40 no.1
    • /
    • pp.27-34
    • /
    • 2017
  • The author investigated interventional radiology patient doses in several other countries, assessed accuracy of DAP meters embedded in intervention equipments in domestic country, conducted measurement of patient doses for 13 major interventional procedures with use of Dose Area Product(DAP) meters from 23 hospitals in Korea, and referred to 8,415 cases of domestic data related to interventional procedures by radiation exposure after evaluation the actual effectives of dose reduction variables through phantom test. Finally, dose reference level for major interventional procedures was suggested. In this study, guidelines for patient doses were $237.7Gy{\cdot}cm^2$ in TACE, $17.3Gy{\cdot}cm^2$ in AVF, $114.1Gy{\cdot}cm^2$ in LE PTA & STENT, $188.5Gy{\cdot}cm^2$ in TFCA, $383.5Gy{\cdot}cm^2$ in Aneurysm Coil, $64.6Gy{\cdot}cm^2$ in PTBD, $64.6Gy{\cdot}cm^2$ in Biliary Stent, $22.4Gy{\cdot}cm^2$ in PCN, $4.3Gy{\cdot}cm^2$ in Hickman, $2.8Gy{\cdot}cm^2$ in Chemo-port, $4.4Gy{\cdot}cm^2$ in Perm-Cather, $17.1Gy{\cdot}cm^2$ in PCD, and $357.9Gy{\cdot}cm^2$ in Vis, EMB. Dose referenece level acquired in this study is considered to be able to use as minimal guidelines for reducing patient dose in the interventional radiology procedures. For the changes and advances of materials and development of equipments and procedures in the interventional radiology procedures, further studies and monitorings are needed on dose reference level Korean DAP dose conversion factor for the domestic procedures.

Bacteriological Research for the Contamination of Equipment in Chest Radiography (영상의학과 흉부 엑스선 촬영 기기의 세균 오염도)

  • Choi, Seung Gu;Song, Woon Heung;Kweon, Dae Cheol
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.395-401
    • /
    • 2015
  • The purpose is to determine the degree of contamination of the equipment for infection control in chest radiography of the radiology department. We confirmed by chemical and bacterial identification of bacteria of the equipment and established a preventive maintenance plan. Chest X-ray radiography contact area on the instrument patients shoulder, hand, chin, chest lateral radiography patient contact areas with a 70% isopropyl alcohol cotton swab were compared to identify the bacteria before and after sterilization on the patient contact area in the chest radiography equipment of the department. The gram positive Staphylococcus was isolated from side shoots handle before disinfection in the chest radiography equipment. For the final identification of antibiotic tested that it was determined by performing the nobobiocin to the sensitive Staphylococcus epidermidis. Chest radiography equipment before disinfecting the handle side of Staphylococcus epidermidis bacteria were detected using a disinfectant should be to prevent hospital infections.

Does hyrax expansion therapy affect maxillary sinus volume? A cone-beam computed tomography report

  • Darsey, Drew M.;English, Jeryl D.;Kau, Chung H.;Ellis, Randy K.;Akyalcin, Sercan
    • Imaging Science in Dentistry
    • /
    • v.42 no.2
    • /
    • pp.83-88
    • /
    • 2012
  • Purpose : The aim of this study was to investigate the initial effects of maxillary expansion therapy with Hyrax appliance and to evaluate the related changes in maxillary sinus volume. Materials and Methods : Thirty patients (20 females, 10 males; 13.8 years) requiring maxillary expansion therapy, as part of their comprehensive orthodontic treatment, were examined. Each patient had cone-beam computed tomography (CBCT) images taken before (T1) and after (T2) maxillary expansion therapy with a banded Hyrax appliance. Multiplanar slices were used to measure linear dimensions and palatal vault angle. Volumetric analysis was used to measure maxillary sinus volumes. Student t tests were used to compare the pre- and post-treatment measurements. Additionally, differences between two age groups were compared with Mann-Whitney U test. The level of significance was set at p=0.05. Results : Comparison of pre-treatment to post-treatment variables revealed significant changes in the transverse dimension related to both maxillary skeletal and dental structures and palatal vault angle, resulting in a widened palatal vault (p<0.05). Hard palate showed no significant movement in the vertical and anteroposterior planes. Nasal cavity width increased on a mean value of 0.93mm(SD=0.23, p<0.05). Maxillary sinus volume remained virtually stable. No significant age differences were observed in the sample. Conclusion : Hyrax expansion therapy did not have a significant impact on maxillary sinus volume.

Effect of gamma irradiation on the size of cellulose nanocrystals with polyethylene glycol and sodium hydroxide/Gd2O3 nanocomposite as contrast agent in magnetic resonance imaging (MRI)

  • Fathyah Whba;Faizal Mohamed;Mohd Idzat Idris;Rawdah Whba;Noramaliza Mohd Noor
    • Nuclear Engineering and Technology
    • /
    • v.56 no.5
    • /
    • pp.1803-1812
    • /
    • 2024
  • The attractive properties of gadolinium-based nanoparticles as a positive contrast agent for magnetic resonance imaging (MRI) have piqued the interest of both researchers and clinicians. Nonetheless, due to the biotoxicity of gadolinium (III) ions' free radicals, there is a need to address this issue. Therefore, this research aimed to develop a biocompatible, dispersible, stable, hydrophilic, and less toxic cellulose nanocrystals/gadolinium oxide nanocomposite as contrast agent properties for MRI purposes. This study aimed to synthesize gadolinium oxide nanoparticles coated with cellulose nanocrystals with polyethylene glycol and sodium hydroxide (CNCs-PEG/NaOH)/Gd2O3 using the gamma irradiation method to reduce the particle size. The results showed that using a gamma irradiation dose of 10 kGy, quasi-spherical morphology with a size of approximately 5.5 ± 0.65 nm could be produced. Furthermore, the cytocompatibility of (CNCs-PEG/NaOH)/Gd2O3 nanocomposite synthesized was assessed through MTT assay tests on Hep G2 cells, which demonstrated good cytocompatibility without any cytotoxic effects within a concentration range of (10 ㎍/mL - 150 ㎍/mL) and had sufficient cellular uptake. Moreover, the T1-weighted MRI of (CNCs-PEG/NaOH)/Gd2O3 nanocomposite revealed promising results as a positive contrast agent. It is envisaged that the gamma irradiation method is promising in synthesizing (CNCs-PEG/NaOH)/Gd2O3 nanocomposite with nanoscale for different applications, especially in the radiotherapy field.

A Case Study on Activity-Based Costing for a hospital (전통적 원가계산과 활동기준 원가계산의 비교연구)

  • Jung, Yong-Mo;Yang, Dong-Hyun;Lee, Yong-Chul;Leem, Bock-Hee
    • Korea Journal of Hospital Management
    • /
    • v.10 no.1
    • /
    • pp.25-47
    • /
    • 2005
  • This study was purposed to find out the difference of the accounting of practical cost between the ABC system and the traditional costing system applied in a hospital, to verified general effect of ABC. Methods: This case study deals with the method of calculation, the cost information that is produced at K hospital in Busan. To examine ABC system and traditional costing system, applying them to the clinical pathology, radiology, physics in K hospital. Results: As a result of costing analysis, it is showed maximum difference of 50% between ABC and traditional cost. compared in revenue center, it occurs the difference of 15% of them. considering the result, it is confirmed that ABC could be used as a means to offer more precise information. therefore, ABC makes possible to produce precise costing information and grasp the driver of cost, and it is possible to reduce cost effectively. Conclusion: ABC provide six benefits: (1) more accurate of service delivered (2) inproved pricing and contracting strategies (3) improved management decision making capability (4) greater ease of determining relevant costs (5) reduced nonvalue added costs.

  • PDF

Effects of NEX on SNR and Artifacts in Parallel MR Images Acquired using Reference Scan

  • Heo, Yeong-Cheol;Lee, Hae-Kag;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.18 no.4
    • /
    • pp.422-427
    • /
    • 2013
  • The aim of this study was to investigate effects of the number of acquisitions (NEX) on signal-to-noise (SNR) and artifacts in SENSE parallel imaging of magnetic resonance imaging (MRI). 3.0T MR System, 8 Channel sensitivity encoding (SENSE) head coils were used along with an in-vivo phantom. Reference sequence of 3D fast field echo (FFE) was consisted of NEX values of 2, 4, 6, 8, 10 and 12. The T2 turbo spin echo (TSE) sequence used for exams achieved SENSE factors of 1.2, 1.5, 1.8, 2.0, 2.2, 2.5, 2.8, 3.0, 3.2, 3.5, 3.8 and 4.0. Exams were conducted five times for each SENSE factor to measure signal intensity of the object, the posterior phase-encode direction and frequency direction. And SNR was calculated using mean values. SENSE artifacts were identified as background signal intensity in the phase-encoded direction using MRIcro. It was found that SNR increased but SENSE artifacts reduced with NEX of 4, 8 and 12 when the NEX increased in reference scan. It is therefore concluded that image quality can be improved with NEX of 4, 8 and 12 for reference scanning.