• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.034 seconds

Focal form of acquired myasthenia gravis with megaesophagus in a Yorkshire terrier dog

  • Hahn, Tae-Yeon;Kang, Min-Hee;Eom, Ki-Dong;Park, Hee-Myung
    • Korean Journal of Veterinary Research
    • /
    • v.54 no.1
    • /
    • pp.59-62
    • /
    • 2014
  • A 12-year-old, castrated male Yorkshire terrier dog presented with frequent regurgitations that had begun 45 days earlier and become more progressive. Radiographs revealed an air-trap region behind the cranial esophageal sphincter muscle in the esophagus and esophagographies with barium contrast showed mild esophageal dilation with decreased motility. Esophageal motility increased within 5 min of neostigmine methylsulfate administration and acetylcholine receptor antibodies titer increased to beyond the normal range. Based on these findings, acquired myasthenia gravis with focal form was diagnosed, making this the first such case diagnosed by an acetylcholine receptor antibody test in Korea.

Myelin Water Fraction MRI in a Case of Clinically Probable Amyotrophic Lateral Sclerosis (근위축성측삭경화증 환자에서의 myelin water fraction MRI 1예)

  • Yang, Jiwon;Lee, Jongho;Kim, EungYeop;Shin, Dong Hoon
    • Annals of Clinical Neurophysiology
    • /
    • v.18 no.1
    • /
    • pp.18-20
    • /
    • 2016
  • Amyotrophic lateral sclerosis (ALS) is a progressive motor neuron degenerative disease that clinically manifests both upper and lower motor neuron signs. However, it is unknown where and how the motor neuron degeneration begins, and conflicting hypotheses have been suggested. Recent advanced radiological techniques enable us to look into ALS neuropathology in vivo. Herein, we report a case with upper motor neuron-predominant ALS in whom the results of brain magnetic resonance imaging (MRI) and myelin water fraction MRI suggest axonal degeneration.

Unique case of a geminated supernumerary tooth with trifid crown

  • Ather, Amber;Ather, Hunaiza;Sheth, Sanket Milan;Muliya, Vidya Saraswathi
    • Imaging Science in Dentistry
    • /
    • v.42 no.3
    • /
    • pp.197-200
    • /
    • 2012
  • Gemination, a relatively uncommon dental anomaly, is characterized by its peculiar representation as a tooth with a bifid crown and a common root and root canal. It usually occurs in primary dentition. To come across gemination in a supernumerary tooth is a rare phenomenon. The purpose of this paper is to present a unique case of hyperdontia wherein gemination in an impacted supernumerary tooth resulted in a trifid crown unlike the usual bifid crown. The role of conventional radiographs as well as computed tomography, to accurately determine the morphology and spatial location, and to arrive at a diagnosis, is also emphasized in this paper.

Maxillary sinus aspergilloma of odontogenic origin: Report of 2 cases with cone-beam computed tomographic findings and review of the literature

  • Torul, Damla;Yuceer, Ezgi;Sumer, Mahmut;Gun, Seda
    • Imaging Science in Dentistry
    • /
    • v.48 no.2
    • /
    • pp.139-145
    • /
    • 2018
  • Aspergilloma of the maxillary sinus is considered rare in immunocompetent patients, but a considerable increase has recently been seen in the incidence of reported cases. Dental procedures involving the antral region are thought to predispose individuals to this form of aspergillosis. Because aspergilloma shares similar clinical features with other sinus pathologies, its diagnosis may be delayed. Thus, an early diagnosis confirmed by a histopathological examination plays a crucial role in the adequate management of aspergilloma. This article provides a concise review of the reported cases of aspergilloma associated with dental procedures and reports 2 new cases of aspergilloma in middle-aged female patients, with a presentation of their cone-beam computed tomographic findings.

Clinical, radiographic, and histological findings of florid cemento-osseous dysplasia: a case report

  • Kim, Jeong-Hee;Song, Byeong-Chul;Kim, Sun-Ho;Park, Yang-Soon
    • Imaging Science in Dentistry
    • /
    • v.41 no.3
    • /
    • pp.139-142
    • /
    • 2011
  • Cemento-osseous dysplasias are a group of disorders known to originate from periodontal ligament tissue and involve, essentially, the same pathological process. They are usually classified into three main groups: periapical, florid, and focal cemental dysplasias depending on their extent and radiographic appearances. Radiographically, florid cemento-osseous dysplasia (FCOD) appears as dense, lobulated masses, often symmetrically located in various regions of the jaws. The best management for the asymptomatic FCOD patient consists of regular recall examinations with prophylaxis. The management of the symptomatic patient is more difficult. A case of FCOD occurring in a 52-year-old edentulous Korean female is reported which is rare with regard to race and sex.

Extracolonic manifestations of Gardner syndrome: A case report

  • McKenzie C. Blackwell;Bhushan Thakkar;Andres Flores;Wenjian Zhang
    • Imaging Science in Dentistry
    • /
    • v.53 no.2
    • /
    • pp.169-174
    • /
    • 2023
  • Gardner syndrome has head and neck manifestations that may be recognized during dental visits. Features such as multiple gnathic osteomas, impacted supernumerary teeth, and multiple foci of idiopathic osteosclerosis can be easily identified on dental radiographs, prompting the clinician to refer the patient for further investigation. A dental examination and routine radiographs play a vital role in revealing the extracolonic presentation of Gardner syndrome, which facilitates timely screening and detection of colorectal cancer and other malignancies associated with this condition. This report discusses the case of a 50-year-old Caucasian man who presented with a hard swelling of the left angle of the mandible and was diagnosed with Gardner syndrome based on abnormal findings from an oral examination, dental imaging, and medical and family history.

Effects of the Questionnaire and Radioactivity Measurement of Fishery from the Fukushima Nuclear Disaster (후쿠시마 원자력 재해 이후 수산물의 방사능 측정 및 설문 조사)

  • Kim, Myung Jun;Kang, Seok Min;Kweon, Dae Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.1
    • /
    • pp.53-58
    • /
    • 2016
  • March 11, 2011 Fukushima nuclear power plant accident has occurred, the last four years, his is the current state of anxiety remains on the consumer. Therefore, 2015 the current progress continues to have continued research for the purpose of resolving the insecurity of fishery in the country. We measured the radiation of the origin of fishery products, by 2015, research was carried out through a number of references to get additional data or studies that influence this to some degree. Create a consumer and one for the seller for the survey to find out the thoughts of both consumers and sellers on fisheries was to create the statistics by direct survey in 2014 year survey meter using PM1405 equipment dynamics of several species of aquatic origin in accordance with the (Taiwan, China, Russia), mackerel, pomfret, hairtail, saury, shrimp, squid measurements of radiation were investigated. The measurement in 2014 was $0.043{\sim}0.073{\mu}Sv/h$. The seller influenced the survey (90%) on fishery products sales, consumer safety, without this fishery (90%), radioactive contamination very high (28%) and the polarization was not as nearly 72%. The study of the stability of the radiation determined by the radiation levels of the aquatic marine products in a comparison the radiation levels result was determined in ICRP below the standard value (1 mSv/y).

A Study on Feasibility of Total Variation Algorithm in Skull Image using Various X-ray Exposure Parameters (다양한 X-ray 촬영조건을 이용하여 획득한 skull 영상에서의 Total Variation 알고리즘의 가능성 연구)

  • Park, Sung-Woo;Lee, Jong-In;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.765-771
    • /
    • 2019
  • Noise in skull X-ray imaging is inevitable, which reduces imaging quality and diagnostic accuracy and increases errors due to the nature of digital imaging devices. Increasing the dose can attenuate noise, but that could lead to big problems with higher exposure dose received by patients. Thus, noise reduction algorithms are actively being studied at low doses to solve dose problems and reduce noise at the same time. Wiener filter and median filter have been widely used, with the disadvantages of poor noise reduction efficiency and loss of much information about imaging boundary. The purpose of this study is to apply total variation (TV) algorithm to skull X-ray imaging that can compensate for the problems of previous noise reduction efficiency to assess quantitatively and compare them. For this study, skull X-ray imaging is obtained using various kVp and mAs using the skull phantom using the X-ray device of Siemens. In addition, contrast to noise ratio (CNR) and coefficient of variation (COV) are compared and measured when noisy image, median filter, Wiener filter and TV algorithm were applied to each phantom imaging. Experiments showed that when TV algorithms were applied, CNR and COV characteristics were excellent under all conditions. In conclusion, we've been able to see if we can use TV algorithm to improve image quality and CNR could be seen to increase due to the decrease in noise as the amount of increased mAs. On the other hand, COV decreased as the amount of increased mAs, and when kVp increased, noise was reduced and the transmittance was increased, so COV was reduced.

Usefulness of Pulsatile Flow Aortic Aneurysm Phantoms for Stent-graft Placement (스텐트그라프트 장치술을 위한 대동맥류 혈류 팬텀의 유용성)

  • Kim, Tae-Hyung;Ko, Gi-Young;Song, Ho-Young;Park, In-Kook;Shin, Ji-Hoon;Lim, Jin-Oh;Kim, Jin-Hyoung;Choi, Eu-Gene K.
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.205-212
    • /
    • 2007
  • To evaluate the feasibility and efficacy of a pulsatile aortic aneurysm phantoms for in-vitro study. The phantoms consisted of a pulsating motor part(heart part) and an aortic aneurysm part, which mimicked true physiologic conditions. The heart part was created from a high-pressured water pump and a pulsatile flow solenoid valve for the simulation of aortic flow. The aortic aneurysm part was manufactured from paper clay, which was placed inside a acrylic plastic square box, where liquid silicone was poured. After the silicone was formed, the clay was removed, and a silicone tube was used to connect the heart and aneurysm part. We measured the change in pressure as related to the opening time(pulse rate, Kruskal-Wallis method) and pressure before and after the stent-graft implantation(n = 5, Wilcoxon's signed ranks test). The changes in blood pressures according to pulse rate were all statistically significant(p<0.05). The systolic/diastolic pressures at the proximal aorta, the aortic aneurysm, and the distal aorta of the model were $157.80{\pm}1.92/130.20{\pm}1.92$, $159.40{\pm}1.14/134.00{\pm}2.92$, and $147.20{\pm}1.480/129.60{\pm}2.70\;mmHg$, respectively, when the pulse rate was 0.5 beat/second. The pressures changed to $161.40{\pm}1.34/90.20{\pm}1.64$, $175.00{\pm}1.58/93.00{\pm}1.58$, and $176.80{\pm}1.48/90.80{\pm}1.92\;mmHg$, respectively, when the pulse rate was 1.0 beat/second, and $159.40{\pm}1.82/127.20{\pm}1.48$, $166.60{\pm}1.67/138.00{\pm}1.87$, and $161.00{\pm}1.22/135.40{\pm}1.67\;mmHg$, respectively, when it was 1.5 beat/second. When pulse rate was set at 1.0 beat/second, the pressures were $143.60{\pm}1.67/90.20{\pm}1.64$, $147.20{\pm}1.92/84.60{\pm}1.82$, and $137.40{\pm}1.52/88.80{\pm}1.64\;mmHg$ after stent-graft implantation. The changes of pressure before and after stent-graft implantation were statistically significant(p<0.05) except the diastolic pressures at the proximal(p =1.00) and distal aorta(p=0.157). The aortic aneurysm phantoms seems to be useful for the evaluation of the efficacy of stent-graft before animal or clinical studies because of its easy reproducibility and ability to display a wide range of pressures.

  • PDF

AN IV CATHETER FRAGMENTS DURING MDCT SCANNING OF HUMAN ERROR: EXPERIMENTAL AND REPRODUCIBLE MICROSCOPIC MAGNIFICATION ANALYSIS

  • Kweon, Dae-Cheol;Lee, Jong-Woong;Choi, Ji-Won;Yang, Sung-Hwan;Dong, Kyung-Rae;Chung, Woon-Kwan
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.4
    • /
    • pp.195-199
    • /
    • 2011
  • The use of intravenous catheters are occasionally complicated by intravascular fragments and swelling of the catheter fragments. We present a patient in whom an intravenous catheter fragments was retrieved from the dorsal metacarpal vein following its incidental CT examination detection. The case of demonstrates the utility of microscopy and multi-detector CT in localizing small of subtle intravenous catheter fragments as a human error. A case of IV catheter fragments in the metacarpal vein, in which reproducible and microscopy data allowed complete localization of a missing fragments and guided surgery with respect to the optimal incision site for fragments removal. These reproducible studies may help to determine the best course of action and treatment for the patient who presents with such a case.