• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.03 seconds

Entrance Surface Dose according to Dose Calculation : Head and Wrist (피폭선량 산출을 통한 피부입사선량 계산: 머리 및 손목을 중심으로)

  • Sung, Ho-Jin;Han, Jae-Bok;Song, Jong-Nam;Choi, Nam-Gil
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.305-312
    • /
    • 2016
  • This study were compared with the direct measurement and indirect dose methods through various dose calculation in head and wrist. And, the modified equation was proposed considering equipment type, setting conditions, tube voltage, inherent filter, added filter and its accompanied back scatter factor. As a result, it decreased the error of the direct measurement than the existing dose calculation. Accordingly, diagnostic radiography patient dose comparison would become easier and radiogrphic exposure control and evaluation will become more efficient. The study findings are expected to be useful in patients' effective dose rate evaluation and dose reduction.

Usefulness of Liver Fibrosis According to Classification of Image Score System In Abdominal Ultrasonography (복부 초음파검사에서 영상 점수 시스템 분류에 따른 간 섬유화 평가의 유용성)

  • An, Hyun;Ji, Tae-jeong;Lee, Hyo-young;Im, In-chul
    • Journal of radiological science and technology
    • /
    • v.42 no.3
    • /
    • pp.187-194
    • /
    • 2019
  • The purpose of this study was to evaluate the pathologic results of hepatic parenchyma parameters such as liver parenchyma, liver surface, liver margin and liver, portal vein, spleen size, And to evaluate the usefulness of fibrosis progression and hepatic ultrasonography. The sensitivity, specificity, positive predictive value, and prognostic value according to the stage of fibrosis and grade of inflammation were divided into two groups according to the morphologic variable "A" through ultrasound and "B" We evaluated the predictive value and predicted the variables to evaluate fibrosis in clinical diagnosis and treatment of patients with chronic liver disease. The sensitivity and specificity of hepatic fibrosis in hepatic morphologic variables and other size variables were highest in liver surface and edge. The morphologic parameters used in the evaluation of fibrosis were clinically relevant in distinguishing the fibrosis stage from the results of liver biopsy.

Complete transverse basilar cleft associated with hemifacial microsomia

  • Laphatrada Yurasakpong;Athikhun Suwannakhan;Joe Iwanaga;R. Shane Tubbs;Arada Chaiyamoon;Nutmethee Kruepunga;Somluk Asuvapongpatana;Thanwa Sudsang
    • Anatomy and Cell Biology
    • /
    • v.57 no.3
    • /
    • pp.473-475
    • /
    • 2024
  • Transverse basilar cleft (TBC) is an extremely rare variation of the clivus or the basilar part of the occipital bone. In this report, a unilateral transverse basilar fissure was found at the clivus in a head computed tomography of an 18-yearold female patient diagnosed with hemifacial microsomia (HFM). Image analysis of this patient showed shortening of the ramus of the right mandible along with medial displacement of the right temporomandibular joint and hypoplastic right maxilla. In addition, observation of the clivus showed a cleft between the basioticum and basioccipital bones at the level of the pharyngeal tubercle on the right side. This cleft was identified as TBC. Clival variations, TBC included, attributed to HFM have never been reported. This report draws attention to the complex relationship between abnormal development of clivus and HFM syndrome, and sheds light on a possible genetic and molecular association between these two conditions.

Experimental renal artery embolization with iohexol-ethanol and barium-ethanol in dogs (개에서 iohexol-ethanol 및 barium-ethanol을 이용한 실험적 신동맥 색전술)

  • Hwang, Guk-jin;Chang, Dongwoo;Seo, Minho;Jung, Joohyun;Choi, Mincheol;Yoon, Junghee
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.3
    • /
    • pp.429-436
    • /
    • 2001
  • The present study was performed to investigate the effect of iohexol-ethanol mixture and barium-ethanol mixture on the induction of transcatheter renal artery embolization in healthy 18 dogs, which were divided into two groups of 9 dogs and the 9 dogs were divided into 3 subgroups of 3 dogs. The renal artery embolization was undertaken unilaterally with the dose of 1.5, 2.0, and 3.0 ml/kg iohexol-ehtanol mixture and with the dose of 0.2, 0.4, and 0.8 ml/kg barium-ethanol mixture. And serum chemistry on 0, 1,3, 7, and 14 days, intravenous pyelography on 7days, angiography on 14 days, and histopathology on 14 days were evaluated. Serum BUN and creatinine concentration of two groups with iohexol-ethanol mixture and barium-ethanol mixture administration were mildly increased a t 1 day after injection of embolic materials and then returned to baseline. No significant changes in BUN and creatinine levels occurred in any of dogs. In all dogs with the dose of 1.5 ml/kg iohexol-ethanol mixture, the renal arteries were not embolized. All dogs with the dose of 3.0 ml/kg died. In all dogs with the dose of 2.10 ml/kg, the treated arteries were completely occluded. In barium-ethanol mixture administered group, the renal artery in one dog with the dose of 0.2 ml/kg was not embolized. In all dogs with the dose of 0.8 ml/kg, the renal arteries were completely embolized, but loac overembolization occured in two dogs. All animals with the dose of 0.4 ml/kg had effective embolization and no evidence of radiopaque barium opacity in systemic arteries distal to the renal-artery was found. All embolized kidneys were shrunk and decreased in size in gross examination and were shown diffuse necrosis in histopathologic examination. In the present study, renal arteries were embolized with the dose of 2.0 ml/kg iohexol-ethanol mixture or 0.4 ml/kg barium-ethanol mixture. And it is considered that the dose had a satisfactory embolic effect.

  • PDF

A Study on the Cardiopulmonary Resuscitation Education of the Medical Workers (의료기관 종사자의 심폐소생술 교육에 관한 연구)

  • Lee, Hyun-Suk;Lim, Cheong-Hwan;Park, Hae-Ri;Jung, Hong-Ryang;Yang, Oh-Nam
    • Journal of radiological science and technology
    • /
    • v.41 no.3
    • /
    • pp.261-265
    • /
    • 2018
  • Most schools and educational institutions, as well as most companies, show willingness to teach CPR. However, as an essential element for the health care workers, this study aims to analyze the appropriate timing of education and improvements to the education, focusing on those who have trained for CPR. The survey was conducted for only those who applied for CPR education regardless of their profession in medical institutions. There were 105 males and 93 females by gender, and an average of 198 females were 33.5 years. The difference in CPR education depending on individual characteristics showed a high demand that all research subjects' gender, age and marital status should be improved to a practical education. During the education period, the efficiency of CPR was high. It is expected that the education of CPR will be used for the improvement of the training cycle and the training content since it is the enhancement of the performance capabilities that require practical application.

Median Modified Wiener Filter for Noise Reduction in Computed Tomographic Image using Simulated Male Adult Human Phantom (시뮬레이션된 성인 남성 인체모형 팬텀을 이용한 전산화단층촬영 에서의 노이즈 제거를 위한 Median Modified Wiener 필터)

  • Ju, Sunguk;An, Byungheon;Kang, Seong-Hyeon;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.21-28
    • /
    • 2021
  • Computed tomography (CT) has the problem of having more radiation exposure compared to other radiographic apparatus. There is a low-dose imaging technique for reducing exposure, but it has a disadvantage of increasing noise in the image. To compensate for this, various noise reduction algorithms have been developed that improve image quality while reducing the exposure dose of patients, of which the median modified Wiener filter (MMWF) algorithm that can be effectively applied to CT devices with excellent time resolution has been presented. The purpose of this study is to optimize the mask size of MMWF algorithm and to see the excellence of noise reduction of MMWF algorithm for existing algorithms. After applying the MMWF algorithm with each mask sizes set from the MASH phantom abdominal images acquired using the MATLAB program, which includes Gaussian noise added, and compared the values of root mean square error (RMSE), peak signal-to-noise ratio (PSNR), coefficient correlation (CC), and universal image quality index (UQI). The results showed that RMSE value was the lowest and PSNR, CC and UQI values were the highest in the 5 x 5 mask size. In addition, comparing Gaussian filter, median filter, Wiener filter, and MMWF with RMSE, PSNR, CC, and UQI by applying the optimized mask size. As a result, the most improved RMSE, PSNR, CC, and UQI values were showed in MMWF algorithms.

Characterization of mandibular molar root and canal morphology using cone beam computed tomography and its variability in Belgian and Chilean population samples

  • Torres, Andres;Jacobs, Reinhilde;Lambrechts, Paul;Brizuela, Claudia;Cabrera, Carolina;Concha, Guillermo;Pedemonte, Maria Eugenia
    • Imaging Science in Dentistry
    • /
    • v.45 no.2
    • /
    • pp.95-101
    • /
    • 2015
  • Purpose: This study used cone-beam computed tomography (CBCT) to characterize mandibular molar root and canal morphology and its variability in Belgian and Chilean population samples. Materials and Methods: We analyzed the CBCT images of 515 mandibular molars (257 from Belgium and 258 from Chile). Molars meeting the inclusion criteria were analyzed to determine (1) the number of roots; (2) the root canal configuration; (3) the presence of a curved canal in the cross-sectional image of the distal root in the mandibular first molar and (4) the presence of a C-shaped canal in the second mandibular molar. A descriptive analysis was performed. The association between national origin and the presence of a curved or C-shaped canal was evaluated using the chi-squared test. Results: The most common configurations in the mesial root of both molars were type V and type III. In the distal root, type I canal configuration was the most common. Curvature in the cross-sectional image was found in 25% of the distal canals of the mandibular first molars in the Belgian population, compared to 11% in the Chilean population. The prevalence of C-shaped canals was 10% or less in both populations. Conclusion: In cases of unclear or complex root and canal morphology in the mandibular molars, CBCT imaging might assist endodontic specialists in making an accurate diagnosis and in treatment planning.

Positioning errors of dental implants and their associations with adjacent structures and anatomical variations: A CBCT-based study

  • Ribas, Beatriz Ribeiro;Nascimento, Eduarda Helena Leandro;Freitas, Deborah Queiroz;Pontual, Andrea dos Anjos;Pontual, Maria Luiza dos Anjos;Perez, Danyel Elias Cruz;Ramos-Perez, Flavia Maria Moraes
    • Imaging Science in Dentistry
    • /
    • v.50 no.4
    • /
    • pp.281-290
    • /
    • 2020
  • Purpose: The objective of the present study was to evaluate the prevalence of dental implants positioning errors and their associations with adjacent structures and anatomical variations by means of cone-beam computed tomography (CBCT). Materials and Methods: CBCT images of 207 patients (584 dental implants) were evaluated by 2 oral radiologists. The distance between the implant and the adjacent teeth/implants was measured and classified as adequate (≥1.5 mm and ≥3 mm, respectively) or inadequate. The presence of thread exposure, cortical perforation, implant dehiscence, implant penetration into adjacent structures, and anatomical variations was also recorded. The incisor canal diameter and the depth of the concavity of the submandibular fossa were measured in order to evaluate their correlations with the frequency of implant penetration in these structures. Descriptive analyses, the Fisher exact test, and Spearman correlation analysis were performed (α=0.05). Results: The overall prevalence of positioning errors was 82.9%. The most common error was the inadequate distance between the implant and the adjacent teeth/implants. The presence of anatomical variations did not significantly influence the overall prevalence of errors (P>0.05). There was a positive correlation between the diameter of the incisor canal and the frequency of implant penetration in this structure (r=0.232, P<0.05). Conclusion: There was a high prevalence of dental implant positioning errors, and positioning errors were not associated with the presence of anatomical variations. Professionals should be aware of the space available for implant placement during the preoperative planning stage.

Comparison of limited- and large-volume cone-beam computed tomography using a small voxel size for detecting isthmuses in mandibular molars

  • de Souza Tolentino, Elen;Andres Amoroso-Silva, Pablo;Alcalde, Murilo Priori;Yamashita, Fernanda Chiguti;Iwaki, Lilian Cristina Vessoni;Rubira-Bullen, Izabel Regina Fischer;Duarte, Marco Antonio Hungaro
    • Imaging Science in Dentistry
    • /
    • v.51 no.1
    • /
    • pp.27-34
    • /
    • 2021
  • Purpose: This study was performed to compare the ability of limited- and large-volume cone-beam computed tomography (CBCT) to display isthmuses in the apical root canals of mandibular molars. Materials and Methods: Forty human mandibular first molars with isthmuses in the apical 3 mm of mesial roots were scanned by micro-computed tomography (micro-CT), and their thickness, area, and length were recorded. The samples were examined using 2 CBCT systems, using the smallest voxels and field of view available for each device. The Mann-Whitney, Friedman, and Dunn multiple comparison tests were performed (α=0.05). Results: The 3D Accuitomo 170 and i-Cat devices detected 77.5% and 75.0% of isthmuses, respectively (P>0.05). For length measurements, there were significant differences between micro-CT and both 3D Accuitomo 170 and i-Cat(P<0.05). Conclusion: Both CBCT systems performed similarly and did not detect isthmuses in the apical third in some cases. CBCT still does not equal the performance of micro-CT in isthmus detection, but it is nonetheless a valuable tool in endodontic practice.

Factors affecting the reduction rate of odontogenic cysts after decompression based on 3-dimensional volumetric analysis

  • Sarawut Wongrattanakarn;Vorapat Trachoo;Boosana Kaboosaya;Pornkawee Charoenlarp;Net-nada Chongruangsri;Patcharapit Promoppatum
    • Imaging Science in Dentistry
    • /
    • v.53 no.4
    • /
    • pp.313-323
    • /
    • 2023
  • Purpose: This study aimed to investigate the potential factors that could affect the reduction rate of odontogenic cysts following decompression using cone-beam computed tomography (CBCT) for 3-dimensional volumetric analysis. Materials and Methods: The study sample consisted of CBCT images of 41 individuals who underwent decompression of odontogenic cysts at the Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Chulalongkorn University, between 2010 and 2022. Preoperative and postoperative CBCT results were collected, and a volumetric analysis was conducted to evaluate the differences in the reduction rate and the percentage of volume reduction of cystic lesions based on different parameters. Correlations between these parameters were analyzed to determine associations. Results: In this study, the average time of decompression for odontogenic cysts was 316 days. Males demonstrated a higher reduction rate than females (P<0.05). The reduction rate was directly proportional to initial cyst volume, with higher reduction rates for cysts with large initial volume than those with small initial volume (P<0.05). Spearman's rank correlation coefficient indicated a weak positive correlation between the initial cyst volume and the duration of decompression. Additionally, a strong positive correlation was observed between the initial volume and the reduction rate. Conclusion: Knowledge of the reduction rate of odontogenic cysts is vital for surgeons to evaluate the duration of decompression before enucleation and to determine a definitive treatment plan. Sex and initial lesion volume had significant effects on the reduction rate.