• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.026 seconds

Effectiveness of a fast spin echo technique using the signal void in acquisition of black blood images (흑혈류영상 획득 시 신호소실을 활용한 고속스핀에코기법의 유용성)

  • Choi, Kwan-Woo;Kim, Yoon-Shin;Son, Soon-Yong;Lee, Hee-Ju;Min, Jung-Whan;Lee, Jong-Seok;Yoo, Beong-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4313-4319
    • /
    • 2013
  • The purpose of our study is to shorten the scanning time and minimize the inconveniences of the patients in acquisition of the black blood images using the signal void effect in the fast spin echo technique while keeping the diagnostic value of the test. Thirty-two consecutive patients who underwent black blood MR imaging were examed with additional double inversion recovery (DIR) sequence and the conventional fast spin echo (FSE) sequence. Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR) of the internal carotid arteries' lumen were compared in T1 and T2 weighted images to determine whether there are differences between the two techniques for depiction of the signal void effect inside the vessel wall. The FSE images showed lower SNR values than the DIR images in both of the T1 and T2 weighted images (11.49% and 13.66% respectively). While the CNR values were higher in the FSE images than in the DIR images in both of the T1 and T2 weighted images (8.69% and 7.55% respectively).There was no significant difference between the two techniques for either of the SNR or CNR (p>0.05, p>0.05 respectively). The DIR and the FSE images demonstrated almost identical imaging patterns. Therefore, it is anticipated that the use of FSE technique in acquisition of the black blood imaging could reduce the inconveniences of the patients during the scanning and minimize exam time while keeping the diagnostic value of the test.

The effectiveness of a pre-procedural mouthrinse in reducing bacteria on radiographic phosphor plates

  • Hunter, Allison;Kalathingal, Sajitha;Shrout, Michael;Plummer, Kevin;Looney, Stephen
    • Imaging Science in Dentistry
    • /
    • v.44 no.2
    • /
    • pp.149-154
    • /
    • 2014
  • Purpose: This study assessed the effectiveness of three antimicrobial mouthrinses in reducing microbial growth on photostimulable phosphor (PSP) plates. Materials and Methods: Prior to performing a full-mouth radiographic survey (FMX), subjects were asked to rinse with one of the three test rinses ($Listerine^{(R)}$, $Decapinol^{(R)}$, or chlorhexidine oral rinse 0.12%) or to refrain from rinsing. Four PSP plates were sampled from each FMX through collection into sterile containers upon exiting the scanner. Flame-sterilized forceps were used to transfer the PSP plates onto blood agar plates (5% sheep blood agar). The blood agar plates were incubated at $37^{\circ}C$ for up to 72 h. An environmental control blood agar plate was incubated with each batch. Additionally, for control, 25 gas-sterilized PSP plates were plated onto blood agar and analyzed. Results: The mean number of bacterial colonies per plate was the lowest in the chlorhexidine group, followed by the Decapinol, Listerine, and the no rinse negative control groups. Only the chlorhexidine and Listerine groups were significantly different (p=0.005). No growth was observed for the 25 gas-sterilized control plates or the environmental control blood agar plates. Conclusion: The mean number of bacterial colonies was the lowest in the chlorhexidine group, followed by the Decapinol, Listerine, and the no rinse groups. Nonetheless, a statistically significant difference was found only in the case of Listerine. Additional research is needed to test whether a higher concentration (0.2%) or longer exposure period (two consecutive 30 s rinse periods) would be helpful in reducing PSP plate contamination further with chlorhexidine.

Evaluate the diagnostic accuracy in the assessment of coronary artery stenoses using MDCT (MDCT를 이용한 관상동맥협착 진단의 정확성 평가)

  • Yang, Won-Seok;Sin, Sung-Gyu;Park, Jae-Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.4
    • /
    • pp.275-279
    • /
    • 2012
  • Methods and results : The suspected patient who have results of CTA and CAG examinations to evaluate coronary stenose to undergo each 16MD CT(n=93) and dual source CT(n=100). As a results of statistic, the highest rank of sensitivity, specificity, PPV, NPV and accuracy in coronary artery with using 16MDCT was displayed in LAD(73.5%), RCA(74.5%), LAD(66.7%), LCX(75%), LCX(67.7%). The mean diagnostic accuracy of dual source CT was more 17% than 16MDCT. Dual source CT was recorded 84% mean of accuracy. In addition to, segments of coronary artery did not show significant differences in all of them. However, distal segment become more and more accurate than proximal site.

Observation of Changes in Indoor Formaldehyde(HCHO) Concentration during Ultrasound Guided Biopsy (초음파 조직생검 시 실내의 포름알데히드(HCHO) 농도 변화 관찰)

  • Lee, Hoon-Jeong;Kang, Sung-Jin
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.1057-1064
    • /
    • 2021
  • This study was conducted by simulating the same environmental conditions as the actual biopsy to observe the change in formaldehyde(HCHO) concentration in the indoor air during ultrasound guided biopsy. Changes in HCHO concentration in the room were measured by successively performing five steps: sealing the ultrasound room, ventilation, opening formalin containers, sealing formalin containers, and re-ventilating. Trends of measured HCHO concentration changes were visualized using graphs. As a result of analyzing the consistency of the concentration change values measured three times using the intra-class correlation coefficient, it was found to be 0.989, which was statistically significant(p<0.05). Based on the results of this study, we hope that medical workers working in the HCHO exposure environment of the field of radiology part will improve their awareness of the necessity of exposure management at work, and actively discuss the establishment of an environment for exposure control and preparation of countermeasures.

Effect of Simvastatin collagen graft on wound healing of defective bone (Simvastatin이 골결손부 회복에 미치는 영향)

  • Kang, Jung-Ho;Kim, Gyu-Tae;Choi, Yong-Suk;Lee, Hyeon-Woo;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.38 no.3
    • /
    • pp.133-146
    • /
    • 2008
  • Purpose : To observe and evaluate the effects of Simvastatin-induced osteogenesis on the wound healing of defective bone. Materials and Methods : 64 defective bones were created in the parietal bone of 32 New Zealand White rabbits. The defects were grafted with collagen matrix carriers mixed with Simvastatin solution in the experimental group of 16 rabbits and with collagen matrix carriers mixed with water in the controlled group. The rabbits were terminated at an interval of 3, 5, 7, and 9 days, 2, 4, 6, and 8 weeks after the formation of defective bone. The wound healing was evaluated by soft X-ray radiography. The tissues within defective bones were evaluated through the analysis of flow cytometry for the manifestation of Runx2 and Osteocalcin, and observed histopathologically by using H-E stain and Masson's trichrome stain. Results : 1. In the experimental group, flow cytometry revealed more manifestation of Runx2 at 5, 7, and 9 days and Osteocalcin at 2 weeks than in the controlled groups, but there was few difference in comparison with the controlled group. 2. In the experimental group, flow cytometry revealed considerably more cells and erythrocytes at 5, 7, and 9 days in comparison with the controlled group. 3. In the experimental group, soft x-ray radiography revealed the extended formation of trabeculation at 2, 4, 6, and 8 weeks. 4. Histopathological features of the experimental group showed more fibroblasts and newly formed vessels at 5 and 7 days, and the formation of osteoid tissues at 9 days, and the newly formed trabeculations at 4 and 6 weeks. Conclusion : As the induced osteogenesis by Simvastatin, there was few contrast of the manifestation between Runx2 and Osteocalcin based on the differentiation of osteoblasts. But it was considered that the more formation of cells and erythrocytes depending on newly formed vessels in the experimental group obviously had an effect on the bone regeneration.

  • PDF

A Study on the Fabrication and Comparison of the Phantom for CT Dose Measurements Using 3D Printer (3D프린터를 이용한 CT 선량측정 팬텀 제작 및 비교에 관한 연구)

  • Yoon, Myeong-Seong;Kang, Seong-Hyeon;Hong, Soon-Min;Lee, Youngjin;Han, Dong-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.737-743
    • /
    • 2018
  • Patient exposure dose exposure test, which is one of the items of accuracy control of Computed Tomography, conducts measurements every year based on the installation and operation of special medical equipment under Article 38 of the Medical Law, And keep records. The CT-Dose phantom used for dosimetry can accurately measure doses, but has the disadvantage of high price. Therefore, through this research, the existing CT - Dose phantom was similarly manufactured with a 3D printer and compared with the existing phantom to examine the usefulness. In order to produce the same phantom as the conventional CT-Dose phantom, a 3D printer of the FFF method is used by using a PLA filament, and in order to calculate the CTDIw value, Ion chambers were inserted into the central part and the central part, and measurements were made ten times each. Measurement results The CT-Dose phantom was measured at $30.44{\pm}0.31mGy$ in the periphery, $29.55{\pm}0.34mGy$ CTDIw value was measured at $30.14{\pm}0.30mGy$ in the center, and the phantom fabricated using the 3D printer was measured at the periphery $30.59{\pm}0.18mGy$, the central part was $29.01{\pm}0.04mGy$, and the CTDIw value was measured at $30.06{\pm}0.13mGy$. Analysis using the Mann - Whiteney U-test of the SPSS statistical program showed that there was a statistically significant difference in the result values in the central part, but statistically significant differences were observed between the peripheral part and CTDIw results I did not show. In conclusion, even in the CT-Dose phantom made with a 3D printer, we showed dose measurement performance like existing CT-Dose phantom and confirmed the possibility of low-cost phantom production using 3D printer through this research did it.

Radiological Science Curriculum on the Digital Radiology Environments : Problems and Suggestions (디지털 방사선 환경에서의 방사선학과의 교육과정에 대한 현황과 개선 방향)

  • Kim, Chang-Soo;Kim, Hwa-Gon
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.129-135
    • /
    • 2005
  • IT communication industries of current society are developed in enormous growth, our country leading the world in the number of super high speed internet equipments in use. In the pride oneself on communication network of those, mobile terminal technology and wireless phone production hold a high rank. Data communication and networking may be the fastest growing technologies in our culture today. In this way, IT fields conjugated in the daily quick, the fact that department of radiological science didn't discharged one's duties on current IT education. The curriculum of radiological technologists that play an important part between skill and occupation's education as major and personality didn't performed one's part most effectively on current IT environments and digital radiological equipments interface. Therefore, in this paper current curriculum of radiological science are catched hold of trend and problems on digital radiology environments, on fact the present state of problems, for radiological engineering and HIS manager, new curriculum course are suggested a reform measure of culture and major education curriculum introduction.

  • PDF

The Evaluation of Usefulness New Assistant Device to Observe Posterior Cruciate Ligament Rupture and Patellofemoral Joint Injury in Emergency Patient (응급환자에서 후방십자인대 손상 및 슬대퇴 관절을 관찰하기 위한 보조기구 제작 및 유용성 평가)

  • Seo, Sun-Youl;Han, Man-Seok;Jeon, Min-Chul;Yu, Se-Jong;Kim, Yong-Kyun
    • Journal of radiological science and technology
    • /
    • v.33 no.2
    • /
    • pp.93-96
    • /
    • 2010
  • This study evaluates usefulness of the developed assistant device by taking projection of patellofemoral joint in emergency patients who were doubt posterior cruciate ligament injury in knee joint. The subjects of experiment were patients who visited Eul-Ji University Hospital due to knee injury from January 2006 to December 2006. Seventeen patients, who took the Knee post stress view, Knee merchant view, Knee Seo's view to use assistant device and Knee MRI. To make assistant device of $170{\times}50{\times}70\;cm$, we evaluated its usefulness by measuring posterior dislocation of tibia. Seo's view is more accurate to make judgment of posterior cruciate ligament injury than original knee post stress view. Interval difference of posterior dislocation of original knee post stress view is $6.17{\pm}3.04$ and Seo's view is $8.74{\pm}4.47$. The results show injury of patellofemoral joint, vertical fracture of patella and posterior cruciate ligament injury by taking a projection using Seo's view. Therefore, it is useful to take projection earlier than talometer and MRI in emergency patients who were doubt posterior cruciate ligament injury in knee joint.

Analysis of Satisfaction and Problems of Clinic Radiological Technologist on the Supplementary Education (보수교육에 대한 의원방사선사의 만족도와 문제점 분석)

  • Jeong, Bong-Jae;Park, Jun-Hong;Song, Jae-Heung;Noh, Si-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.861-868
    • /
    • 2018
  • As the research about supplementary education of radiological technologist who works in medical clinics, this study was conducted to draw the improvements by analyzing the satisfaction level and problems of the supplementary education. During November 01, 2016 to April 30, 2017, after we distributed a total of 150 questionnaires for the survey to radiological technologists working at medical clinics located in Changwon-si, Gyoungsangnam province, 106 questionnaires suitable for research were analysis by using SPSS 18.0 statistical analysis software. As the sociodemographic characteristics, the age, gender, working period, level of education, and working department were used. And As the welfare factors, working environment, financial support, educational opportunity, medical support, working culture, etc. were used. As the satisfaction factors, 21 items such as system, subject, help, appropriateness of lecturer selection, professionalism were used. And as the problem factors, 18 items such as place, transportation, diversity, administrative treatment, education promotion, proceed method were used. Consequentially, the satisfaction level(3.02 point) of the supplementary education were confirmed as normal level. And the problems(3.18 point) of the supplementary education was analyzed a little higher. The supplementary education is the mandatory education that any health and medical service personnel must complete every three years for license re-issuance. There were many opinions that the supplementary education for radiologists working in various medical institutions did not meet the education level of radiologists working in the medical clinics. In order to improve the satisfaction of the supplementary education of medical clinic's radiological technologist, it should be improved the quality of education through a practical education program that reflects various opinions and improvements on conservative education.