• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.036 seconds

Overcoming the Challenges in the Development and Implementation of Artificial Intelligence in Radiology: A Comprehensive Review of Solutions Beyond Supervised Learning

  • Gil-Sun Hong;Miso Jang;Sunggu Kyung;Kyungjin Cho;Jiheon Jeong;Grace Yoojin Lee;Keewon Shin;Ki Duk Kim;Seung Min Ryu;Joon Beom Seo;Sang Min Lee;Namkug Kim
    • Korean Journal of Radiology
    • /
    • v.24 no.11
    • /
    • pp.1061-1080
    • /
    • 2023
  • Artificial intelligence (AI) in radiology is a rapidly developing field with several prospective clinical studies demonstrating its benefits in clinical practice. In 2022, the Korean Society of Radiology held a forum to discuss the challenges and drawbacks in AI development and implementation. Various barriers hinder the successful application and widespread adoption of AI in radiology, such as limited annotated data, data privacy and security, data heterogeneity, imbalanced data, model interpretability, overfitting, and integration with clinical workflows. In this review, some of the various possible solutions to these challenges are presented and discussed; these include training with longitudinal and multimodal datasets, dense training with multitask learning and multimodal learning, self-supervised contrastive learning, various image modifications and syntheses using generative models, explainable AI, causal learning, federated learning with large data models, and digital twins.

Effect of LCD monitor type and observer experience on diagnostic performance in soft-copy interpretations of the maxillary sinus on panoramic radiographs

  • Kim, Tae-Young;Choi, Jin-Woo;Lee, Sam-Sun;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.41 no.1
    • /
    • pp.11-16
    • /
    • 2011
  • Purpose : The aim of this study was to evaluate the effect of liquid crystal display (LCD) monitor type and observer experience on the diagnostic performance in soft-copy interpretations of maxillary sinus inflammatory lesions on panoramic radiographs. Materials and Methods : Ninety maxillary sinuses on panoramic images were grouped into negative and positive groups according to the presence of inflammatory lesions, using CT for confirmation. Monochrome and color LCDs were used. Six observers participated and ROC analysis was performed to evaluate the diagnostic performance. The reading time, fatigue score, and inter-/intra-observer agreements were assessed. Results : The interpretation of maxillary sinus inflammatory lesions was affected by the LCD monitor type used and by the experience of the observer. The reading time was not significantly different, however the fatigue score was significantly different between two LCD monitors. Inter-observer agreement was relatively good in experienced observers, while the intra-observer agreement for all observers was good with monochrome LCD but not with color LCD. Conclusion : The less experienced observers showed lowered diagnostic ability with a general color LCD.

Comparison of effective dose for imaging of mandible between multi-detector CT and cone-beam CT

  • Jeong, Dae-Kyo;Lee, Sang-Chul;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.42 no.2
    • /
    • pp.65-70
    • /
    • 2012
  • Purpose : The aim of this study was to compare the effective dose for imaging of mandible between multi-detector computed tomography (MDCT) and cone-beam computed tomography (CBCT). An MDCT with low dose technique was also compared with them. Materials and Methods : Thermoluminescent dosimeter (TLD) chips were placed at 25 organ sites of an anthropomorphic phantom. The mandible of the phantom was exposed using 2 different types of MDCT units (Somatom Sensation 10 for standard-dose MDCT, Somatom Emotion 6 for low-dose MDCT) and 3 different CBCT units (AZ3000CT, Implagraphy, and Kavo 3D eXaM). The radiation absorbed dose was measured and the effective dose was calculated according to the ICRP 2007 report. Results : The effective dose was the highest for Somatom Sensation 10 (425.84 ${\mu}Sv$), followed by AZ3000CT (332.4 ${\mu}Sv$), Somatom Emotion 6 (199.38 ${\mu}Sv$), and 3D eXaM (111.6 ${\mu}Sv$); it was the lowest for Implagraphy (83.09 ${\mu}Sv$). The CBCT showed significant variation in dose level with different device. Conclusion : The effective doses of MDCTs were not significantly different from those of CBCTs for imaging of mandible. The effective dose of MDCT could be markedly decreased by using the low-dose technique.

Inflammatory myofibroblastic tumor : A case report (염증성 근섬유모세포종의 증례보고)

  • Eun Sang-A;Park Hyok;Cha In-Ho;Kim Hyun-Sil;Jeong Ho-Gul;Kim Kee-Deog;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.36 no.3
    • /
    • pp.169-175
    • /
    • 2006
  • The Inflammatory myofibroblastic tumor (inflammatory pseudotumor) is a rarely occurring soft tissue lesion of unknown etiology. It can be of any location, but commonly it is found in lungs. It has been considered as a nonneoplastic reactive inflammatory lesion, but nowadays, confusion and dispute about its character is increasing due to its high recurrence rate and metastasis. We present a patient who had been diagnosed with an inflammatory pseudotumor in the right maxilla area, 1 year before visiting our hospital. After that, her pain and swelling did not resolved and she visit our hospital. On radiographic examination, aggressively infiltrative growth of the lesion with destruction of adjacent bony structure was noted. We found unusual aggressiveness of the inflammatory myofibroblastic tumor of the head and neck region. Because the typical behavior of the inflammatory myofibroblastic tumor is not defined yet, we recommend the surgical excision of the lesion and close follow-up.

  • PDF

Acquired facial lipoatrophy: A report of 3 cases with imaging features

  • Lee, Chena;Kim, Jo-Eun;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Han, Sang-Sun;Choi, Soon-Chul;Huh, Kyung-Hoe
    • Imaging Science in Dentistry
    • /
    • v.50 no.3
    • /
    • pp.255-260
    • /
    • 2020
  • Acquired facial lipoatrophy is a rare disease with an unclear etiology and pathological pathway. The distinct causative factors of this disease have been not elucidated, but it is suspected to be associated with immune system-related diseases, most notably AIDS. Although the management of facial lipoatrophy is very important for patients' social life and mental health, no treatment framework has been developed due to the unknown nature of the disease manifestation. The present case report was designed to provide sequential imaging to visualize the disease progression. The clinical backgrounds of the patients are also introduced, helping characterize this disease entity more clearly for maxillofacial specialists.

Primary intraosseous squamous cell carcinoma mimicking periapical disease: a case report

  • Choi, Yoon-Joo;Oh, Song-Hee;Kang, Ju-Han;Choi, Hwa-Young;Kim, Gyu-Tae;Yu, Jae-Jung;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.42 no.4
    • /
    • pp.265-270
    • /
    • 2012
  • Primary intraosseous squamous cell carcinoma (PIOSCC) is a rare carcinoma, which arises within the jaws without connection to the oral mucosa and presumably develops from a remnant of odontogenic epithelium. We present a case of solid type PIOSCC in a 52-year-old male patient complaining of dull pain on his left lower molar. In this case, early stage PIOSCC mimicking a periapical lesion might lead to a one-year delay in treatment due to the misdiagnosis of osteomyelitis after extraction of the third molar. The clinical, radiological, and histologic features are described. In this case, there was initial radiographic evidence for PIOSCC mimicking a periapical lesion. Incautious radiographic interpretation and treatment procedures had delayed the correct diagnosis and resulted in extensive bony destruction during the patient's disease progression.

Characteristics of a new cone beam computed tomography

  • Park, Chang-Seo;Kim, Kee-Deog;Park, Hyok;Jeong, Ho-Gul;Lee, Sang-Chul
    • Imaging Science in Dentistry
    • /
    • v.37 no.4
    • /
    • pp.205-209
    • /
    • 2007
  • Purpose: To determine the physical properties of a newly developed cone beam computed tomography (CBCT). Materials and Methods: We measured and compared the imaging properties for the indirect-type flat panel detector (FPD) of a new CBCT and the single detector array (SDA) of conventional helical CT (CHCT). Results: First, the modulation transfer function (MTF) of the CBCT were superior to those of the CHCT. Second, the noise power spectrum (NPS) of the CBCT were worse than those of the CHCT. Third, detective quantum efficiency (DQE) of the indirect-type CBCT were worse than those of the CHCT at lower spatial frequencies, but were better at higher spatial frequencies. Although the comparison of contrast-to-noise ratio (CNR) was estimated in the limited range of tube current, CNR of CBCT were worse than those of CHCT. Conclusion: This study shows that the indirect-type FPD system may be useful as a CBCT detector because of high resolution.

  • PDF

Diurnal Variation in Hydration of the Cervical Intervertebral Disc Assessed Using T2 Mapping of Magnetic Resonance Imaging

  • Chanyuan Liu;Jingyi Wang;Bowen Hou;Yitong Li;John N. Morelli;Peisen Zhang;Jun Ran;Xiaoming Li
    • Korean Journal of Radiology
    • /
    • v.23 no.6
    • /
    • pp.638-648
    • /
    • 2022
  • Objective: The study aimed to investigate the diurnal variation in cervical disc hydration and its relationship with cervical degeneration. Materials and Methods: C3-C7 discs of 86 prospectively enrolled participants (37 males, 49 females; mean age ± standard deviation, 23.5 ± 2.5 years) were assessed using T2 mapping in the morning and evening. All discs were stratified by Miyazaki grade or C2-C7 Cobb angle and T2 values (T2). The degree of diurnal T2 variation (T2-DDV), defined as (morning T2 - evening T2)/morning T2 x 100%, was measured for the entire disc, annulus fibrosus (AF), nucleus pulposus (NP), and endplate zones. Results: T2 of the entire disc decreased significantly after the daytime load (p < 0.001), with a T2-DDV of 13.3% for all discs and 16.0%, 12.2%, and 13.0% for healthy (grade I), mild degenerative (grade II), and advanced degenerative (grade III/IV) discs, respectively. T2 of regional NPs and AFs decreased significantly from morning to evening (p ≤ 0.049) except in the healthy anterior inner AF (p = 0.092). Compared with healthy discs, mild degenerative discs displayed lower T2 and T2-DDV in regional NPs (p < 0.001). Advanced degenerative discs showed higher T2-DDV in the anterior inner AF compared with healthy discs (p = 0.050). Significant diurnal T2 changes in the endplate zones were observed only in healthy discs (p = 0.013). Cervical discs in the low Cobb angle group showed higher T2-DDV in the anterior AFs and anterior NP and lower T2-DDV in the posterior AF than those in the high Cobb angle group (p ≤ 0.041). Conclusion: This study characterized the diurnal variation in hydration of the cervical discs as assessed using T2 mapping and revealed early chemo-mechanical coupling dysfunction in degenerating discs. Cervical sagittal alignment on MRI can affect the diurnal stress patterns of the cervical discs. T2 mapping is sensitive to disc biomechanical dysfunction and offers translational potential from biomechanical research to clinical application.

Effect of Perfluorobutane Microbubbles on Radiofrequency Ablation for Hepatocellular Carcinoma: Suppression of Steam Popping and Its Clinical Implication

  • Dong Young Jeong;Tae Wook Kang;Ji Hye Min;Kyoung Doo Song;Min Woo Lee;Hyunchul Rhim;Hyo Keun Lim;Dong Hyun Sinn;Heewon Han
    • Korean Journal of Radiology
    • /
    • v.21 no.9
    • /
    • pp.1077-1086
    • /
    • 2020
  • Objective: To evaluate the effect of perfluorobutane microbubbles (Sonazoid®, GE Healthcare) on steam popping during radiofrequency (RF) ablation for treating hepatocellular carcinoma (HCC), and to assess whether popping affects treatment outcomes. Materials and Methods: The institutional review board approved this retrospective study, which included 90 consecutive patients with single HCC, who received percutaneous RF ablation as the first-line treatment. The patients were divided into two groups, based on the presence or absence of the popping phenomenon, which was defined as an audible sound with a simultaneous sudden explosion within the ablation zone as detected via ultrasonography during the procedure. The factors contributing to the popping phenomenon were identified using multivariable logistic regression analysis. Local tumor progression (LTP) and disease-free survival (DFS) were assessed using the Kaplan-Meier method with the log-rank test for performing comparisons between the two groups. Results: The overall incidence of the popping phenomenon was 25.8% (24/93). Sonazoid® was used in 1 patient (4.2%) in the popping group (n = 24), while it was used in 15 patients (21.7%) in the non-popping group (n = 69). Multivariable analysis revealed that the use of Sonazoid® was the only significant factor for absence of the popping phenomenon (odds ratio = 0.10, p = 0.048). There were no significant differences in cumulative LTP and DFS between the two groups (p = 0.479 and p = 0.424, respectively). Conclusion: The use of Sonazoid® has a suppressive effect on the popping phenomenon during RF ablation in patients with HCC. However, the presence of the popping phenomenon may not affect clinical outcomes.

Ablative Outcomes of Various Energy Modes for No-Touch and Peripheral Tumor-Puncturing Radiofrequency Ablation: An Ex Vivo Simulation Study

  • Dong Ik Cha;Min Woo Lee;Kyoung Doo Song;Seong Eun Ko;Hyunchul Rhim
    • Korean Journal of Radiology
    • /
    • v.23 no.2
    • /
    • pp.189-201
    • /
    • 2022
  • Objective: To compare the outcomes of radiofrequency ablation (RFA) using dual switching monopolar (DSM), switching bipolar (SB), and combined DSM + SB modes at two different interelectrode distances (25 and 20 mm) in an ex vivo study, which simulated ablation of a 2.5-cm virtual hepatic tumor. Materials and Methods: A total of 132 ablation zones were created (22 ablation zones for each protocol) using three separable clustered electrodes. The performances of the DSM, SB, and combined DSM + SB ablation modes were compared by evaluating the following parameters of the RFA zones at two interelectrode distances: shape (circularity), size (diameter and volume), peritumoral ablative margins, and percentages of the white zone at the midpoint of the two electrodes (ablative margin at midpoint, AMm) and in the electrode path (ablative margin at electrode path, AMe). Results: At both distances, circularity was the highest in the SB mode, followed by the DSM + SB mode, and was the lowest in the DSM mode. The circularity of the ablation zone showed a significant difference among the three energy groups (p < 0.001 and p = 0.002 for 25-mm and 20-mm, respectively). All size measurements, AMm, and AMe were the greatest in the DSM mode, followed by the DSM + SB mode, and the lowest were with the SB mode (all statistically significant). The white zone proportion in AMm and AMe were the greatest in the SB mode, followed by the DSM + SB mode and DSM in general. Conclusion: DSM and SB appear to be complementary in creating an ideal ablation zone. RFA with the SB mode can efficiently eradicate tumors and create a circular ablation zone, while DSM is required to create a sufficient ablative margin and a large ablation zone.