• 제목/요약/키워드: Radiological risk

Search Result 410, Processing Time 0.034 seconds

Research of z-axis geometric dose efficiency in multi-detector computed tomography (MDCT 장치의 z-축 기하학적 선량효율에 관한 연구)

  • Kim, You-Hyun;Kim, Moon-Chan
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.167-175
    • /
    • 2006
  • With the recent prevalence of helical CT and multi-slice CT, which deliver higher radiation dose than conventional CT due to overbeaming effect in X-ray exposure and interpolation technique in image reconstruction. Although multi-detector and helical CT scanner provide a variety of opportunities for patient dose reduction, the potential risk for high radiation levels in CT examination can't be overemphasized in spite of acquiring more diagnostic information. So much more concerns is necessary about dose characteristics of CT scanner, especially dose efficient design as well as dose modulation software, because dose efficiency built into the scanner's design is probably the most important aspect of successful low dose clinical performance. This study was conducted to evaluate z-axis geometric dose efficiency in single detector CT and each level multi-detector CT, as well as to compare z-axis dose efficiency with change of technical scan parameters such as focal spot size of tube, beam collimation, detector combination, scan mode, pitch size, slice width and interval. The results obtained were as follows ; 1. SDCT was most highest and 4 MDCT was most lowest in z-axis geometric dose efficiency among SDCT, 4, 8, 16, 64 slice MDCT made by GE manufacture. 2. Small focal spot was 0.67-13.62% higher than large focal spot in z-axis geometric dose efficiency at MDCT. 3. Large beam collimation was 3.13-51.52% higher than small beam collimation in z-axis geometric dose efficiency at MDCT. 4. Z-axis geometric dose efficiency was same at 4 slice MDCT in all condition and 8 slice MDCT of large beam collimation with change of detector combination, but was changed irregularly at 8 slice MDCT of small beam collimation and 16 slice MDCT in all condition with change of detector combination. 5. There was no significant difference for z-axis geometric dose efficiency between conventional scan and helical scan, and with change of pitch factor, as well as change of slice width or interval for image reconstruction. As a conclusion, for reduction of patient radiation dose delivered from CT examination we are particularly concerned with dose efficiency of equipment and have to select proper scanning parameters which increase z-axis geometric dose efficiency within the range of preserving optimum clinical information in MDCT examination.

  • PDF

A Study on the Relationship between Adiponectin, BDNF and Leptin with Abdominal Fat Thickness in Male Workers (남성 근로자의 복부지방두께와 adiponectin, BDNF 및 leptin의 관련성)

  • Ko, Kyung-Sun;Choi, Yoon-Jung
    • Journal of radiological science and technology
    • /
    • v.36 no.3
    • /
    • pp.209-217
    • /
    • 2013
  • Adiponectin (AdipoN), brain-derived nerotrophic factor (BDNF) and leptin (LeP) are mainly secreted from adipose tissue and are known to be involved in regulation of the development of obese. However, there are not many studies on the association between abdominal fat and neuropeptides such as AdipoN, BDNF and LeP. The aim of this study was undertaken to investigate the association between abdominal fat thickness, neuropeptides and cardiovascular disease (CVD) risk factors. The participants in the study were 138 male employees without CVD. This study was approved by the Institutional Review Board of Occupational Safety and Health Research Institute. Written informed consent for the participants in this study was obtained from all individuals. We obtained subcutaneous fat thickness (SFT) and visceral fat thickness (VFT) by using ultrasonography and neuropeptides levels were measured with ELISA kit according to the method suggested by kit manufacturer. The mean SFT and VFT were $1.58{\pm}0.51$ and $4.52{\pm}1.44$ cm. The mean concentrations of AdipoN, BDNF and LeP were $3.14{\pm}3.52$ ng/ml, $24.11{\pm}8.52$ pg/ml and $4.27{\pm}2.38$ ng/ml, respectively. VFT were positively correlated with total cholesterol (r=0.217, p<0.05), LDL-cholesterol (r=0.271, p<0.01), triglyceride (r=0.233, p<0.05) and insulin (r=0.338, p<0.01), but was inversely correlated with HDL-cholesterol (r=-420, p<0.01). AdipoN levels were positively correlated with HDL-cholesterol (r=0.220, p<0.05) and were inversely correlated with total cholesterol (r=-0.196, p<0.05), LDL-cholesterol (r=-0.190, p<0.05), triglyceride (r=-0.199, p<0.05), SFT (r=-0.195, p<0.05) and VFT (r=-0.412, p<0.01). However, LeP levels showed a reverse trend to AdipoN. AdipoN level was significantly higher in non-obese participants (BMI<25 kg/m), but LeP concentration was significantly higher in obese participants (BMI>25 kg/m) than in non-obese. On multiple logistic regression analysis, obese were significantly associated with AdipoN (odds ratio=0.784) and LeP (odds ratio=1.494). These results suggested that AdipoN and LeP concentrations are affected abdominal fat and that dysfunction and/or declination in the production and secretion of neuropeptides might induced ultimately obese and CVD.

Visualization of the Origin of the Vertebral Arteries with Color Doppler Sonography (색도플러 초음파검사에 의한 경추골동맥 기시부 관찰)

  • Yoon, Seok-Hwan;Lee, Won-Hong;Lee, Dae-Hyung
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.87-93
    • /
    • 2009
  • Background/aim : Atherosclerotic disease at the origin of the vertebral arteries is one of the risk factors for vertebrobasilar ischemic disease. Assessment and visualization of the origin of the vertebral arteries with color doppler sonography is a non-trivial task. The aim of this study is to increase the visualization rate of the origin of the vertebral arteries with color doppler sonography. Materials and Methods : Color doppler sonography for the vertebral arteries included carotid arteries was performed to 198 patients. We first examined the vertebral artery in the upper neck in the direction of the subclavian artery to distinguish its origin more easily. If the vertebral artery origin was not visualized in natural position, the examiner pushed the transducer toward a clavicle or pushed the shoulder of patient by the other hand. The technical methods for visualization of the vertebral artery origin were classified into three grades: natural position, pushing the transducer, and pushing the shoulder of patient according to the depth (3.0 cm and shallower, deeper than 3.0 cm) of the origin. Results : The origin of the vertebral arteries could be visualized in 97% on the right and in 92% on the left. The origin of the vertebral arteries could be visualized in 98.6%, 1.4%, and 0.0% in natural position, pushing the transducer, and pushing the shoulder of patient, respectively, at shallower than 3.0 cm on the right side. The origin of the vertebral arteries could be visualized in 81.2%, 14.6%, and 4.2% in natural position, pushing the transducer, and pushing the shoulder of patient, respectively, at deeper than 3.0 cm on the right side. The origin of the vertebral arteries could be visualized in 85.4%, 10.7%, and 3.9% in natural position, pushing the transducer, and pushing the shoulder of patient, respectively, at shallower than 3.0 cm on the left side. The origin of the vertebral arteries could be visualized in 55.7%, 30.4%, and 13.9% in natural position, pushing the transducer, and pushing the shoulder of patient, respectively, at deeper than 3.0 cm on the left side. Conclusion : If the examiner pushes the transducer toward a clavicle or pushes the shoulder of patient by the other hand, when the vertebral artery origin during the color doppler sonography is not visualized in natural position, visualization rate of the origin of the both vertebral arteries is increased.

  • PDF

Reliability Verification of FLUKA Transport Code for Double Layered X-ray Protective Sheet Design (이중 구조의 X선 차폐시트 설계를 위한 FLUKA 수송코드의 신뢰성 검증)

  • Kang, Sang Sik;Heo, Seung Wook;Choi, Il Hong;Jun, Jae Hoon;Yang, Sung Woo;Kim, Kyo Tae;Heo, Ye Ji;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.547-553
    • /
    • 2017
  • In the current medical field, lead is widely used as a radiation shield. However, the lead weight is very heavy, so wearing protective clothing such as apron is difficult to wear for long periods of time and there is a problem with the danger of lethal toxicity in humans. Recently, many studies have been conducted to develop substitute materials of lead to resolve these problems. As a substitute materials for lead, barium(Ba) and iodine(I) have excellent shielding ability. But, It has characteristics emitting characteristic X-rays from the energy area near 30 keV. For patients or radiation workers, shielding materials is often made into contact with the human body. Therefore, the characteristic X-rays generated by the shielding material are directly exposured in the human body, which increases the risk of increasing radiation absorbed dose. In this study, we have developed the FLUKA transport code, one of the most suitable elements of radiation transport codes, to remove the characteristic X-rays generated by barium or iodine. We have verified the reliability of the shielding fraction of the structure of the structure shielding by comparing with the MCPDX simulations conducted as a prior study. Using the MCNPX and FLUKA, the double layer shielding structures with the various thickness combination consisting of barium sulphate ($BaSO_4$) and bismuth oxide($Bi_2O_3$) are designed. The accuracy of the type shown in IEC 61331-1 was geometrically identical to the simulation. In addition, the transmission spectrum and absorbed dose of the shielding material for the successive x-rays of 120 kVp spectra were compared with lead. In results, $0.3mm-BaSO_4/0.3mm-Bi_2O_3$ and $0.1mm-BaSO_4/0.5mm-Bi_2O_3$ structures have been absorbed in both 33 keV and 37 keV characteristic X-rays. In addition, for high-energy X-rays greater than 90 keV, the shielding efficiency was shown close to lead. Also, the transport code of the FLUKA's photon transport code was showed cut-off on low-energy X-rays(below 33keV) and is limited to computerized X-rays of the low-energy X-rays. But, In high-energy areas above 40 keV, the relative error with MCNPX was found to be highly reliable within 6 %.

Relationship Between Carotid Intima-Media Thickness Using Ultrasonography and Diagnostic Indices of Metabolic Syndrome (초음파를 이용한 경동맥 내-중막 두께와 대사증후군 진단지표의 연관성)

  • Ko, Kyung-Sun;Heo, Kyung-Hwa;Won, Yong-Lim;Lee, Sung-Kook;Kim, Ki-Woong
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.285-291
    • /
    • 2009
  • The aim of the present study was undertaken to investigate the association between diagnostic indices of metabolic syndrome(MetS) with carotid intima-media thickness using ultrasonography. The participants in the study were 315 male employees without carotid atherosclerosis and other cardiovascular disease. This study was approved by the Institutional Review Board of Occupational Safety and Health Research Institute. Written informed consent for the participants in this study was obtained from all individuals. Anthropometric parameters and biochemical characteristics were done using each specific equipments and the NCEP-ATP III criteria were used to define MetS. They were examined by B-mode ultrasound to measure the carotid intima-media thickness(carotid IMT) at the near and far walls of common carotid and bifurcation(bulb). The mean carotid IMT was $0.739{\pm}0.137\;mm$ and it's thickness significantly increased with the increase in age. Also, amounts of systolic and diastolic blood pressure, triglyceride and fasting glucose were significantly increased with the increase in age. Carotid IMT were significantly correlated with BMI(r=0.170, p=0.004), systolic(r=0.148, p=0.011) and diastolic blood pressure(r=0.123, p=0.036) and HDL-cholesterol(r=-0.164, p=0.005). On multiple logistic regression analysis for the diagnostic indices of MetS, carotid IMT were significantly associated with blood pressure(OR=4.220, p<0.01) and MetS(OR=1.301, p<0.05). The results indicate that blood pressure and MetS are important risk factors for carotid atherosclerosis.

  • PDF

Features and Trends of IEC Particular Standards for Medical Equipment Related to Diagnostic X-ray Based on IEC 60601-1:2005 Ed. 3.0 (IEC 60601-1: 3판이 적용된 진단용 X선장치 관련 개별규격의 동향 및 특징)

  • Kim, Hyun-Ji;Kim, Jung-Min;Choi, In-Seok;Yoon, Yong-Su;Seo, Deok-Nam;Kim, Jung-Su;Kim, Dae-Young;Park, Sung-Yong
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • IEC publications have applied in many countries all over the world such as Europe or Japan and these also have been published as in dustrial standards (KS) and notifications of Korea Food and Drug Administration (KFDA) in Korea. As the general standard of IEC 60601 series for medical electric (ME) equipment was revised as $3^{rd}$ edition in 2005, additional and particular standards have been revised or established newly. Under these circumstances, it is importance for manufacturing and assembling companies or authorized testing companies to understand the trend for revisions of IEC publications. Therefore in this study, the latest version of 3 IEC standards related to medical X-ray equipment : IEC 60601-2-44 for X-ray equipment for computed tomography (CT), IEC 60601-2-45 for mammographic X-ray equipment and IEC 60601-2-54 for X-ray equipment for radiography or radioscopy were covered and analyzed for trends and features accompanied by revision based on IEC 60601-1 $3^{rd}$ Ed. As KFDA notifications in force have referred to the particular standards based on 2nd edition of IEC 60601-1, those revised version of 3 particular standards were compared to KFDA notifications in force. The features of the latest standards applying IEC 60601-1 $3^{rd}$ Ed were shown as following: 1) Requirements for mechanical hazards, especially (motorized) moving parts were emphasized. 2) Indication and recording of patient dose were required. 3) Risk management process was introduced and enabled to monitor potential risks systematically. 4) DR system (digital radiography system) as well as analogue system (film-screen system) was included in the scope. Presently, KFDA will revise the notifications applying the particular standards based on IEC 60601-1 $3^{rd}$ Ed in a few years. Therefore the features of particular standards applying IEC 60601-1 $3^{rd}$ Ed was expected to help manufacturers, assemblers or testing companies of medical electric equipment understand IEC publications or KFDA notifications slated to be published.

Giant Schwannoma May Mimic Soft Tissue Sarcoma (악성 연부 종양으로 오인하기 쉬운 신경 및 연부조직의 거대 신경초종)

  • Kim, Yongsung;Jeon, Dae-Geun;Cho, Wan Hyeong;Song, Won Seok;Kim, Kyunghoon
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.6
    • /
    • pp.511-519
    • /
    • 2020
  • Purpose: Schwannoma is a benign tumor that occurs mainly in the peripheral nerve. If the tumor is large or is in areas other than the nerves, it is likely to be mistaken for malignant soft tissue tumors. The authors reviewed 50 cases of giant schwannomas and assessed the distribution of the primary locations, clinical symptoms, radiological and pathological diagnosis, and diagnostic accuracy. Materials and Methods: Of the 214 pathologically confirmed schwannomas, 50 cases with a maximum diameter of 5 cm or more were extracted. The entire cohort was classified into three subgroups (major peripheral nerve, intramuscular, bone) according to the primary location, and the anatomical locations were specified. Results: When the entire cohort was classified according to the primary location, 14 tumors occurred in the major peripheral nerve, 31 cases in the muscle, and 5 cases in the bone. The mean size of the tumor in the entire cohort was 7.0 cm, and the intramuscular subgroup had the largest size with 8.0 cm. The radiological diagnosis revealed 33 out of 50 cases to be benign schwannoma (66.0%), 15 cases as low-grade malignancy (30.0%), and the remaining two cases (4.0%) as a suspicious tuberculosis abscess and tenosynovial giant cell tumor, respectively. On the clinical symptoms, Tinel sign was the most common in the peripheral nerve group with 78.6% (11/14), while 93.5% of the intramuscular group had palpation of the mass with a mean duration of 66.6 months. In the bone group, one out of five cases was reported as a low-grade malignancy. Two cases of postoperative complications were encountered; one was bleeding after tumor excision, which required hemostasis, and the other was peroneal nerve palsy after surgery. Conclusion: When assessing the large-sized soft tissue tumors in the muscles, the possibility of a benign schwannoma should be considered if 1) there is a long period of mass palpation and 2) non-specific findings in MRI. Preoperative pathology confirmation with a biopsy can help reduce the risk of overtreatment.

Is It Appropriate to Insert Pedicle Screws at an Infected Vertebral Body in the Treatment of Lumbar Pyogenic Spondylodiscitis? (요추부 화농성 척추염의 수술적 치료: 이환된 추체에 척추경 나사 고정이 타당한가?)

  • Na, Hwa-Yeop;Jung, Yu-Hun;Lee, Joo-Young;Kim, Hyung-Do
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.5
    • /
    • pp.419-426
    • /
    • 2021
  • Purpose: In the surgical treatment of pyogenic lumbar spondylodiscitis, screw insertion at the affected vertebra has been avoided because of biofilm formation, and the risk of infection recurrence. The authors analyzed the success rate of infection treatment while minimizing the number of instrumented segments by inserting pedicle screws into the affected vertebrae. Therefore, this study examined the usefulness of this technique. Materials and Methods: From January 2000 to June 2018, among patients with pyogenic lumbar spondylodiscitis treated surgically, group A consisted of patients with pedicle screws inserted directly at the affected vertebrae (28 cases), and group B underwent fusion by inserting screws at the adjacent normal vertebrae due to bone destruction of the affected vertebral pedicle (20 cases). The classified clinical results were analyzed retrospectively. All patients were treated via the posterior-only approach, so the affected disc and sequestrum were removed. Posterior interbody fusion was performed with an autogenous strut bone graft, and the segments were then stabilized with pedicle screw systems. The hospitalization period, operation time, amount of blood loss, EQ-5D index, duration of intravenous antibiotics, and the clinical and radiological results were analyzed. Results: In group A, the number of instrumented segments, operation time, blood loss, and EQ-5D index at one month postoperatively showed significant improvement compared to group B. There were no significant differences in the duration of antibiotic use, hospitalization, radiological bone union time, sagittal angle correction rate, and recurrence rate. Conclusion: Minimal segmental fixation, in which pedicle screws were inserted directly into the affected vertebrae through the posterior approach, reduced the surgery time and blood loss, preserved the lumbar motion by minimizing fixed segments and showed rapid recovery without spreading or recurrence of infection. Therefore, this procedure recommended for the surgical treatment of lumbar pyogenic spondyodiscitis.

Radiotherapy Results of Pineal Tumors (송과선종의 방사선치료 성적)

  • Chai Kyu Young;Park Woo Yoon;Choi Doo Ho;Chung Woong Ki;Kim Il Han;Ha Sung Whan
    • Radiation Oncology Journal
    • /
    • v.6 no.2
    • /
    • pp.177-182
    • /
    • 1988
  • A retrospective analysis was peformed on 23 patients with pineal region tumors treated with radiation from 1979 through 1985 at the Department of Therapeutic Radiology, Seoul National University Hospital. Histologic confirmation was done in only one case by surgical removal, and in the remaining 22 patients, the diagnosis was based on clinical and radiological findings. The radiation volume was the primary tumor site in 1 case, whole brain in 14 cases, and the whole craniospinal axis En 8 cases. The overall 5 year survival was $71.5\%$. The 5 year survival was $69.3\%$ for whole brain treated group and $73.3\%$ for craniospinal axis treated group. The survival for the two groups did not differ significantly. In two cases sites of recurrence were detected, one in supratentorial area, and the other in the lung. The results from this retrospective analysis and the review of other reports indicate that routine use of prophylactic spinal irradiation is not warranted in pineal region tumor, and the craniospinal irradiation is recommended in cases with high risk for subarachnoid seeding such as positive CSF cytology, surgical removal or biopsy.

  • PDF

Preliminary Research on the Implementation of Information of Human Facial Part Required for the 3D Printing of Eye Shield (안구차폐체 제작에 필요한 안면부 3차원 정보 구현의 기초연구)

  • Choi, Seokyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.955-960
    • /
    • 2019
  • The Computed tomography (CT) scan can have high radiation in a few tests, and this risk is significant given that it is often repeated in one patient. In children, the incidence of radiation-induced cancer is reported because organs are growing, are more sensitive to radiation. 3D printing has recently been studied to be applied to various applications as a research field for 3D printing applications, research on fabrication of radiation shields and materials has been conducted. The purpose of the 3D printer is to replace the existing panel-type shields and to make customized designs according to the shape of the human body. Therefore, research on 3D information processing to be input to the 3D printer is also necessary. In this study, 3D data of the human body surface, which is the preliminary step of the manufacture of patient-specific eye shield using stereo vision depth map technology, was studied. This study aims to increase the possibility of three-dimensional output. As a result of experimenting with this method, which is relatively simple compared with other methods of 3D information processing, the minimum coordinates for 3D information are extracted. The results of this study provided the advantages and limitations of stereo images using natural light and will be the basic data for the manufacture of eye shields in the future.