• 제목/요약/키워드: Radiological Engineering

검색결과 759건 처리시간 0.027초

방사선사법 제정의 필요성 (The Necessity of Redefining the Radiological Technologist Independent Law)

  • 임우택;임청환;주영철;홍동희;정홍량;정영진;최지원;윤용수;김은혜;유세종;박명환;양오남;정봉재
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권5호
    • /
    • pp.545-554
    • /
    • 2021
  • According to the changes of the medical environment of the times, it is necessary to discuss the issues of the doctor's medical guidance and to conduct continuous research so that alternatives can be prepared systematically. Furthermore, in order to enhance the professionalism of radiological technologists and to develop the medical technician system, the new Radiological Technologist Independent Act has been established, which contains the overall contents of the scope of work, professional qualifications, and specialized education of radiological technologists, and provides quality medical services to patients through professional procedures and treatment. In order to increase the level of medical care, the purpose, definition, mission, role, and scope of work specified in the Medical Act, Medical Service Technologists, etc. Act, the Enforcement Decree, and the Enforcement Rules were variously analyzed and new directions were presented. First, the definition of a medical technician should use a generic term so that the factors of conflict and prejudice could be resolved. Second, change the doctor's guide to doctor's prescription; and then legislate the authority to sign and write medical records after examination by radiological technologists, thereby prohibiting unlicensed technicians that seriously endanger patient safety. Third, an accurate definition of radiological technologists' roles should be established; not only selection and management of radiological technologists' work but also procedures and treatment for each radiology field should be specified to suit the current medical system. Fourth, a professional radiological technologists' qualification system and a specialized education system should be established in order to secure human resources that could provide patients trust in procedures and treatment based on professional knowledge and experience in the field of radiology. Fifth, the Education and Evaluation Institute should be operated in Korea education system to educate the professional knowledge and competency for students. In addition, it is necessary to in-depth analysis of foreign cases could be applied to the medical system and education system in Korea; it could strive to nurture systematic human resources.

Electron beam scattering device for FLASH preclinical studies with 6-MeV LINAC

  • Jeong, Dong Hyeok;Lee, Manwoo;Lim, Heuijin;Kang, Sang Koo;Lee, Sang Jin;Kim, Hee Chang;Lee, Kyohyun;Kim, Seung Heon;Lee, Dong Eun;Jang, Kyoung Won
    • Nuclear Engineering and Technology
    • /
    • 제53권4호
    • /
    • pp.1289-1296
    • /
    • 2021
  • In this study, an electron-scattering device was fabricated to practically use the ultra-high dose rate electron beams for the FLASH preclinical research in Dongnam Institute of Radiological and Medical Sciences. The Dongnam Institute of Radiological and Medical Sciences has been involved in the investigation of linear accelerators for preclinical research and has recently implemented FLASH electron beams. To determine the geometry of the scattering device for the FLASH preclinical research with a 6-MeV linear accelerator, the Monte Carlo N-particle transport code was exploited. By employing the fabricated scattering device, the off-axis and depth dose distributions were measured with radiochromic films. The generated mean energy of electron beams via the scattering device was 4.3 MeV, and the symmetry and flatness of the off-axis dose distribution were 0.11% and 2.33%, respectively. Finally, the doses per pulse were obtained as a function of the source to surface distance (SSD); the measured dose per pulse varied from 4.0 to 0.2 Gy/pulse at an SSD range of 20-90 cm. At an SSD of 30 cm with a 100-Hz repetition rate, the dose rate was 180 Gy/s, which is sufficient for the preclinical FLASH studies.

Analysis of the influence of nuclear facilities on environmental radiation by monitoring the highest nuclear power plant density region

  • Lee, UkJae;Lee, Chanki;Kim, Minji;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • 제51권6호
    • /
    • pp.1626-1632
    • /
    • 2019
  • Monitoring of environmental radioactivity is essential for ensuring the radiological safety of residents who live near nuclear power plants. Ulsan, South Korea, is surrounded by 16 nuclear power plants, the highest density in the country. In addition, the city contains facilities for conducting radiological nondestructive testing and using radioisotopes for medical purposes. It makes the confirmation of radiological safety particularly necessary. In this study, sampling points were selected based on regional characteristics, and surface water samples were pretreated and analyzed for gross beta and gamma radiation levels. In addition, the distribution of the city's gamma dose rate was determined using a mobile monitoring system and distribution visualization program. The results showed that there is no effect on the gross beta and gamma nuclides of artificial radionuclides, and the gamma dose rate of the entire region did not exceed the environmental radiation level in South Korea overall, confirming the radiological safety of the city.

Thermal dehydration tests of FLiNaK salt for thermal-hydraulic experiments

  • Shuai Che;Sheng Zhang;Adam Burak;Xiaodong Sun
    • Nuclear Engineering and Technology
    • /
    • 제56권3호
    • /
    • pp.1091-1099
    • /
    • 2024
  • Fluoride-salt-cooled High-temperature Reactor (FHR) is a promising nuclear reactor technology. Among many challenges presented by the molten fluoride salts is the corrosion of salt-facing structural components. Higher moisture contents, in the FLiNaK (LiF-NaF-KF, 46.5-11.5-42 mol%) salt, aggravate intergranular corrosion and pitting for the given alloys. Therefore, several thermal dehydration tests of FLiNaK salt were performed with a batch size suitable for thermal-hydraulic experiments. Thermogravimetric Analysis (TGA) was performed for the three constituent fluoride salts individually. Preliminary thermal dehydration plans were then proposed for NaF and KF salts based on the TGA curves. However, the dehydration process may not be required for LiF since its low mass loss (<1.3 wt%). To evaluate the performance of these thermal dehydration plans, a batch-scale salt dehydration test facility was designed and constructed. The preliminary thermal dehydration plans were tested by varying the heating rates, target temperature, and holding time. The sample mass loss data showed that the high temperatures (>500 ℃) were necessary to remove a significant amount of moisture (>1 wt%) from NaF salt, while relatively low temperatures (around 300 ℃) with a long holding time (>10 h) were sufficient to remove most of the moisture from KF salt.

Burnup analysis for HTR-10 reactor core loaded with uranium and thorium oxide

  • Alzamly, Mohamed A.;Aziz, Moustafa;Badawi, Alya A.;Gabal, Hanaa Abou;Gadallah, Abdel Rraouf A.
    • Nuclear Engineering and Technology
    • /
    • 제52권4호
    • /
    • pp.674-680
    • /
    • 2020
  • We used MCNP6 computer code to model HTR-10 core reactor. We used two types of fuel; UO2 and (Th+Pu)O2 mixture. We determined the critical height at which the reactor approached criticality in both two cases. The neutronic and burnup parameters were investigated. The results indicated that the core fueled with mixed (Th+Pu)O2, achieved about 24% higher fuel cycle length than the UO2 case. It also enhanced safeguard security by burning Pu isotopes. The results were compared with previously published papers and good agreements were found.

Application plan for radiological exposure model using virtual reality-based radiological exercise system

  • Lee, Dewhey;Lee, Byung Il;Park, Younwon;Kim, Dohyung
    • Nuclear Engineering and Technology
    • /
    • 제50권5호
    • /
    • pp.745-750
    • /
    • 2018
  • New exercise technology such as the virtual reality (VR)-based exercise system is required to meet soaring demand for target participants in exercises and to alleviate the difficulties in personnel mobilization through an alternative approach to the exercise system. In a previous study, event tree methodologies were introduced in setting up an exercise scenario of a VR-based radiological exercise system. In the scenario, the locations at which major events occur are rephrased as nodes, routes as paths, and public response actions as protective actions or contents of an exercise at individual locations. In the study, a model for estimating effective doses to the participants is proposed to evaluate the exercise system, using the effective dose rates at particular times and locations derived from a computer program. The effective dose received by a student when she/he follows a successful route is about a half of the dose received when she/he does not follow the exercise guide directions. In addition, elapsed time to finish an exercise when following a successful route is less than one-third of the time spent to finish an exercise when following the guide's directions.

Real-time monitoring of ultra-high dose rate electron beams using bremsstrahlung photons

  • Hyun Kim;Dong Hyeok Jeong;Sang Koo Kang;Manwoo Lee;Heuijin Lim;Sang Jin Lee;Kyoung Won Jang
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3417-3422
    • /
    • 2023
  • Recently, as the clinically positive biological effects of ultra-high dose rate (UHDR) radiation beams have been revealed, interest in flash radiation therapy has increased. Generally, FLASH preclinical experiments are performed using UHDR electron beams generated by linear accelerators. Real-time monitoring of UHDR beams is required to deliver the correct dose to a sample. However, it is difficult to use typical transmission-type ionization chambers for primary beam monitoring because there is no suitable electrometer capable of reading high pulsed currents, and collection efficiency is drastically reduced in pulsed radiation beams with ultra-high doses. In this study, a monitoring method using bremsstrahlung photons generated by irradiation devices and a water phantom was proposed. Charges collected in an ionization chamber located at the back of a water phantom were analyzed using the bremsstrahlung tail on electron depth dose curves obtained using radiochromic films. The dose conversion factor for converting a monitored charge into a delivered dose was determined analytically for the Advanced Markus® chamber and compared with experimentally determined values. It is anticipated that the method proposed in this study can be useful for monitoring sample doses in UHDR electron beam irradiation.

Fingernail electron paramagnetic resonance dosimetry protocol for localized hand exposure accident

  • Jae Seok Kim;Byeong Ryong Park;Minsu Cho;Won Il Jang;Yong Kyun Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.270-277
    • /
    • 2023
  • Exposure to ionizing radiation induces free radicals in human nails. These free radicals generate a radiation-induced signal (RIS) in electron paramagnetic resonance (EPR) spectroscopy. Compared with the RIS of tooth enamel samples, that in human nails is more affected by moisture and heat, but has the advantages of being sensitive to radiation and easy to collect. The fingernail as a biological sample is applicable in retrospective dosimetry in cases of localized hand exposure accidents. In this study, the dosimetric characteristics of fingernails were analyzed in fingernail clippings collected from Korean donors. The dose response, fading of radiation-induced and mechanically induced signals, treatment method for evaluation of background signal, minimum detectable dose, and minimum detectable mass were investigated to propose a fingernail-EPR dosimetry protocol. In addition, to validate the practicality of the protocol, blind and field experiments were performed in the laboratory and a non-destructive testing facility. The relative biases in the dose assessment result of the blind and field experiments were 8.43% and 21.68% on average between the reference and reconstructed doses. The results of this study suggest that fingernail-EPR dosimetry can be a useful method for the application of retrospective dosimetry in cases of radiological accidents.