• Title/Summary/Keyword: Radiologic placement

Search Result 14, Processing Time 0.026 seconds

Ultrasound-Guided Placement of Tunneled Hemodialysis Catheters (초음파 유도하 터널식 혈액투석용 도관 삽입술)

  • Lee Hee Bong;Jang Kuhn Jo
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.27 no.2
    • /
    • pp.157-174
    • /
    • 2001
  • Ⅰ. Purpose : To evaluate the usefulness of ultrasound-guided, radiologic placement of tunneled hemodialysis catheters via internal jugular vein(IJV). Ⅱ. Materials and Methods : In 32 patients(31 chronic renal failure, 1 acute renal failure), We performed

  • PDF

Radiologic Evaluation of Proper Pedicle Screw Placement after Pedicle Screw Fixation in Degenerative Lumbar Disc Disease

  • Ju, Sun-Min;Kim, Young-Soo;Kim, Sung-Bum;Ko, Yong;Oh, Seong-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.38 no.4
    • /
    • pp.265-268
    • /
    • 2005
  • Objective : With the increasing popularity of pedicle screw fixation devices for several indications, the safety and reliability of screw insertion in the small pedicle has become a major issue. Many studies have investigated the accuracy of screw placement after pedicle screw fixation using various method. The reported displacement rates have been very different. The purpose of the study is to investigate the proper placement of pedicle screw insertion in the lumbar spine on 26 consecutive patients. Methods : Between September and December 2003, 26 consecutive patients [16women and 10men] were analyzed after transpedicular screw fixation of the lumbar and lumbosacral spine. After pedicle screw fixation in this study, 2-mm slices of CT scan were performed in all patients to detect caudal and cranial deviation of screw and medial and lateral deviation. Pedcile screw placement related complication was evaluated clinically. Results : A total of 144 inserted pedicle were analyzed in 26patients, and 58pedicle screws [40.3%] were detected to be improper placement. There were 14level [9.0%] of caudal or cranial deviation and 44level [30.6%] of medial or lateral deviation to the pedicle. Extra-pedicle placement was found on 4levels [2.7%] with only lease of neurologic injury. Conclusion : Proper screw placement, though complication rate is low, is important not only for clinical symptom but also for biomechanics. Further study for screw placement related biomechanical changes is needed.

Extraoral periapical radiography: an alternative approach to intraoral periapical radiography

  • Kumar, Rahul;Khambete, Neha;Priya, Ekta
    • Imaging Science in Dentistry
    • /
    • v.41 no.4
    • /
    • pp.161-165
    • /
    • 2011
  • It is difficult to take intraoral radiographs in some patients who are intolerable to place the film in their mouth. For these patients, Newman and Friedman recommended a new technique of extraoral film placement. Here we report various cases that diagnostic imaging was performed in patients using the extraoral periapical technique. This technique was used to obtain the radiographs for the patients with severe gag reflex, pediatric dental patients, and patients with restricted mouth opening. This technique can be recommended as an alternative to conventional intraoral periapical technique in cases where intraoral film placement is difficult to achieve.

Long-Term Clinical and Radiologic Outcomes after Stent-Graft Placement for the Treatment of Late-Onset Post-Pancreaticoduodenectomy Arterial Hemorrhage (췌십이지장절제술 후 발생한 후기 출혈에서 스텐트-그라프트를 이용한 치료의 장기적 임상, 영상의학적 결과)

  • Woo Jin Kim;Chang Ho Jeon;Hoon Kwon;Jin Hyeok Kim;Ung Bae Jeon;Suk Kim;Hyung Il Seo;Chang Won Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.3
    • /
    • pp.600-612
    • /
    • 2021
  • Purpose To evaluate the long-term radiologic and clinical outcomes of stent-graft placement for the treatment of post-pancreaticoduodenectomy arterial hemorrhage (PPAH) based on the imaging findings of stent-graft patency and results of liver function tests. Materials and Methods We retrospectively reviewed the medical records of nine consecutive patients who underwent stent-graft placement for PPAH between June 2012 and May 2017. We analyzed the immediate technical and clinical outcomes and liver function test results. Stent-graft patency was evaluated using serial CT angiography images. Results All stent-grafts were deployed in the intended position for the immediate cessation of arterial hemorrhage and preservation of hepatic arterial blood flow. Technical success was achieved in all nine patients. Eight patients survived after discharge, and one patient died on postoperative day 28. The median follow-up duration was 781 days (range: 28-1766 days). Follow-up CT angiography revealed stent-graft occlusion in all patients. However, serum aspartate aminotransferase or alanine aminotransferase levels in all patients were well below those observed in hepatic infarction cases. Conclusion Stent-graft placement is a safe and effective treatment method for acute life-threatening PPAH. Liver function and distal hepatic arterial blood flow were maintained postoperatively despite the high incidence of stent-graft occlusion observed on follow-up CT.

Study of bone healing pattern in extraction socket after application of demineralized dentin matrix material (자가치아 뼈 이식재의 발치와내 이식 후 골 치유 양상에 관한 연구)

  • Chung, Jae-Ho;Lee, Jae-Hoon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.5
    • /
    • pp.365-374
    • /
    • 2011
  • Introduction: Research on dental bone graft material has been actively conducted. Recently, demineralized dentin matrix material has been developed and introduced. This study examined the effect of demineralized dentin matrix material on bone healing. Subjects and Methods: The patients who received no treatment after extraction were used as the control group and patients who underwent demineralized dentin matrix material application in the extraction socket after extraction were used as the experimental group. Panorama radiography was performed at the baseline and at 3.5 months after graft material placement and CT was taken at 3.5 months after graft material placement for a radiologic evaluation. Bony tissue specimens were collected from the alveolar crest in the middle of the extraction socket using a 2 mm trephine bur after 3.5 months for the histology and hostomorphometric study. Results: 1. On the panoramic view, a higher bone density was observed in the subject group. 2. On the panoramic view, the bone density increased significantly in the extraction socket, from the baseline to 3.5 months: a 7 and 10 gray-level scale was observed in the control and experimental group, respectively (P<0.05). 3. The CT view evaluation at 3.5 months revealed significantly higher bone density in the subject group than the control group (P<0.05). 4. The histological findings showed more active new bone and lamellar bone formation in the subject group. Dentin with osteoinduction ability and enamel with osteoconduction ability appeared. 5. On histomorphometric analysis, the subject group showed significantly more new bone, lamellar bone area and lower soft tissue area (P<0.05). The difference between the groups was significant (P<0.05). Conclusion: Bone healing was improved after the application of demineralized dentin matrix material and there was active new bone and lamellar bone formation.

The retrospective study of marginal bone loss around dental implants according to different autogenous bone grafts (이식된 자가골의 종류와 형태에 따른 임플란트 변연골 흡수량에 관한 후향적 연구)

  • Kim, Tae-Yi;Kim, Ye-Mi;Kim, Ji-Youn;Kim, Myung-Rae;Kim, Sun-Jong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.6
    • /
    • pp.483-489
    • /
    • 2011
  • Introduction: This study examined the cumulative resorption of implants placed in a severely atrophic mandible and analyzed the radiologic bone resorption in the marginal bone, after an autogenous bone graft including both block and particulates that had been harvested from the ramus and iliac crest. Materials and Methods: A retrospective study was performed on patients who had bone grafts for augmentation followed by implant installation in the mandible area from 2003 to 2008. Twelve patients (6 men and 6 women) who received 34 implants in the augmented sites were evaluated. Cumulative radiologic resorption around the implants was measured immediately, 3 months, 6 months and 12 months after implant installation surgery. Results: The installed implant in grafted bone showed 0.84 mm marginal bone resorption after 3 months and 50% total cumulative resorption after 1 year. The mean marginal bone resorption around the implant installed in the grafted bone was 0.44 mm after 3 months, 0.52 mm after 1 year, after which it stabilized. The implant survival rate was 97% (failed implant was 1/34). Marginal bone resorption of the installed implant in the autogenous onlay block bone grafts was 0.98 mm after 3 months, which was significantly higher than that of a particulated bone graft (0.74 mm) (P <0.05). Conclusion: An autogenous graft including block type and particulate type is a predictable procedure for the use of dental implants in a severely atrophic mandible. Implant placement in augmented areas show a relatively high survival and minimal bone loss, as revealed by a radiologic evaluation.

A Mouse Colon Model to Investigate Stent-Induced Tissue Hyperplasia (쥐 대장에서 스텐트 삽입 후 발생하는 조직 과증식 모델 형성을 위한 연구)

  • Kim, Min Tae
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.439-445
    • /
    • 2020
  • The purpose of this study was to investigate the feasibility of stent placement and the evaluation of tissue hyperplasia caused by bare metallic stent placement in a mouse colon model. In a pilot study, C57BL/6 mouse were used to verify diameter of colon. Mean diameter size was 4.05 mm. Twenty C57BL/6 mice were divided into two groups to assess differing stent diameters (Group A, 5 mm diameter; Group B. Group B, 4 mm diameter). Follow-up, 1-week fluoroscopic imaging, 4-week endoscopic imaging were obtained. Mice were sacrificed 4-week after stent placement. Microscopic findings were evaluated. Stent placement was technically successful except one mouse in Group A. Data from the mouse was omitted. During follow-up, five mice in Group A died within 7 days after stent placement, and one stent in Group B was migrated into the rectum. The incidence of stent-related complication was 60% and 10% between group A and Group B, respectively. Gross and Endoscopic findings showed tissue hyperplasia through the mesh, and all the stents had become incorporated into the wall of the colon. Microscopic findings were no statistically significant difference. colonic stent placement was technically feasible, and stent-induced tissue hyperplasia was evident in a mouse model. With stent large size, there was the highest incidence of colon perforation.

Third Occipital Nerve Radiofrequency Neurotomy with Radiologic Open Mouth View -A case report- (방사선 구개상을 이용한 제3 후두 신경 고주파신경절개술의 시행 -증례보고-)

  • Park, Jung Ju;Jung, Mi Ae;Shim, Jae Chol
    • The Korean Journal of Pain
    • /
    • v.19 no.2
    • /
    • pp.244-248
    • /
    • 2006
  • Radiofrequency lesioning is a valuable tool for third occipital headache. Relative to most neural targets, a radiofrequency lesion is very small. Reliable pre-operative diagnosis of the nociceptive source is critical, as inappropriately placed lesions will not modulate pain. Knowledge of the anatomical courses of nerves and extremely precise electrode placement are required for accurate lesioning. This report describes our experience with RF lesioning in the treatment of chronic pain in two patients who suffered from third occipital headaches. In one patient, satisfactory improvement of the pain was observed after 10 months of follow up.

Mobile Computed Tomography : Three Year Clinical Experience in Korea

  • Jeon, Jin Sue;Lee, Sang Hyung;Son, Young-Je;Yang, Hee-Jin;Chung, Young Seob;Jung, Hee-Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.1
    • /
    • pp.39-42
    • /
    • 2013
  • Objective : Obtaining real-time image is essential for neurosurgeons to minimize invasion of normal brain tissue and to prompt diagnosis of intracranial event. The aim of this study was to report our three-year experience with a mobile computed tomography (mCT) for intraoperative and bedside scanning. Methods : A total of 357 mCT (297 patients) scans from January 2009 to December 2011 in single institution were reviewed. After excluding postoperative routine follow-up, 202 mCT were included for analysis. Their medical records such as diagnosis, clinical application, impact on decision making, times, image quality and radiologic findings were assessed. Results : Two-hundred-two mCT scans were performed in the operation room (n=192, 95%) or intensive care unit (ICU) (n=10, 5%). Regarding intraoperative images, extent of resection of tumor (n=55, 27.2%), degree of hematoma removal (n=42, 20.8%), confirmation of catheter placement (n=91, 45.0%) and monitoring unexpected complications (n=4, 2.0%) were evaluated. A total of 14 additional procedures were introduced after confirmation of residual tumor (n=7, 50%), hematoma (n=2, 14.3%), malpositioned catheter (n=3, 21.4%) and newly developed intracranial events (n=2, 14.3%). Every image was obtained within 15 minutes and image quality was sufficient for interpretation. Conclusion : mCT is feasible for prompt intraoperative and ICU monitoring with enhanced diagnostic certainty, safety and efficiency.

Fusion Criteria for Posterior Lumbar Interbody Fusion with Intervertebral Cages : The Significance of Traction Spur

  • Kim, Kyung-Hoon;Park, Jeong-Yoon;Chin, Dong-Kyu
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.4
    • /
    • pp.328-332
    • /
    • 2009
  • Objective : The purpose of this study was to establish new fusion criteria to complement existing Brantigan-Steffee fusion criteria. The primary purpose of intervertebral cage placement is to create a proper biomechanical environment through successful fusion. The existence of a traction spur is an essential predictable radiologic factor which shows that there is instability of a fusion segment. We studied the relationship between the existence of a traction spur and fusion after a posterior lumbar interbody fusion (PLIF) procedure. Methods : This study was conducted using retrospective radiological findings from patients who underwent a PLIF procedure with the use of a cage without posterior fixation between 1993 and 1997 at a single institution. We enrolled 183 patients who were followed for a minimum of five years after the procedure, and used the Brantigan-Steffee classification to confirm the fusion. These criteria include a denser and more mature bone fusion area than originally achieved during surgery, no interspace between the cage and the vertebral body, and mature bony trabeculae bridging the fusion area. We also confirmed the existence of traction spurs on fusion segments and non-fusion segments. Results : The PLIF procedure was done on a total of 251 segments in 183 patients (71 men and 112 women). The average follow-up period was $80.4{\pm}12.7$ months. The mean age at the time of surgery was $48.3{\pm}11.3$ years (range, 25 to 84 years). Among the 251 segments, 213 segments (84.9%) were fused after five years. The remaining 38 segments (15.1%) were not fused. An analysis of the 38 segments that were not fused found traction spur formation in 20 of those segments (52.6%). No segments had traction spur formation with fusion. Conclusion : A new parameter should be added to the fusion criteria. These criteria should be referred to as 'no traction spur formation' and should be used to confirm fusion after a PLIF procedure.