• Title/Summary/Keyword: Radiologic factors

Search Result 200, Processing Time 0.024 seconds

Dose and Image Assessment according to Radiologic Factors Variation at Digital Humerus X-ray Examination (디지털 환경에서 Humerus 검사 시 촬영인자 변화에 따른 선량 및 화질 평가)

  • Kim, Seong Min;Hong, Seon Sook;Lee, Kwan Sup;Ha, Dong Yun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.1-8
    • /
    • 2012
  • Purpose : We aim at presenting the optimum radiologic factor through the evaluation of dose variation and of image quality through the use of a grid in Humerus examination and the change of dose because of the change of radiologic factor. Materials and Methods : We divided it in 3 cases: when using a grid or not and when using IP(Image Plate) in a digital system. Also, as fixing kVp to 70kVp it changed mAs, and fixing mAs to 10 it changed kVp, we put up resolution chart and Burger rose phantom on the acrylic phantom of 7cm (the same level of Humerus) to evaluate the dose and image. We used Image J program to evaluate the quantitative resolution of the obtained image, and made the qualitative evaluation and statistical analysis of the image saved in PACS for 20 radiologic technologist with more than 10 years of experience in order of evaluate its contrast. We used SPSS10(SPSS Inc. Chicago, Illinois) for statistical analysis. Results : We observed the analytic result of resolution by the change of kVp that it was $4.539dGycm^2$ in 60kVp and $757.472dGycm^2$ in 75kVp, which increased about 64.6% of dose, while for the resolution it had the pixel value 30.7% better with 851 in 60kVp than 651 in 75kVp. Also, we analyzed the result of resolution by the change of mAs that it was $3.106dGycm^2$ in 5mAs, and $12.470dGycm^2$ in 20mAs, which increased about 400% of dose, while for the resolution DR had 678 in 5mAs, and 724 in 20mAs that increased about 6.8% of resolution. We made the qualitative evaluation of contrast by the change of kVp that DR showed the higher quality than CR, but the contrast by the change of kVp had no special different at the moment of visual evaluation, nor statistically significant difference(P>0.05). We observed the qualitative evaluation of contraste by the change of mAs that the contrast increased as DR increased mAs, and had statistically significant difference(P<0.05). On the other hand, CR had no significant difference for more than 10mAs nor statistically significant difference(P>0.05). Conclusion : In case of some patients with radiographic exposure by the repeated examination such as emergent patient or Follow up patient, they are considered to try to limit the use of a grid, to set kVp under 65kVp in fixed mode, to select less than 10mAs and to reduce the possibility of patient being bombed.

  • PDF

Measurement of Trap Parameters of $CaSO_4:Tm$ TLD using Glow Curve Fitting (Glow 곡선 Fitting에 의한 $CaSO_4:Tm$ TLD의 포획매개변수 측정)

  • Park, Myeong-Hwan;Kim, Sung-Hwan;Lee, Joon-Il;Kim, Do-Sung
    • Journal of radiological science and technology
    • /
    • v.21 no.2
    • /
    • pp.53-56
    • /
    • 1998
  • Highly sensitive $CaSO_4:Tm$ TLD is fabricated and their trap parameters are determined. The glow curve of $CaSO_4:Tm$ consists of three glow peaks and these peaks are isolated by the thermal bleaching method. The isolated glow peaks are fitted by a least squares method. The activation energies are 0.68, 0.82 and 1.03 eV. The frequency factors are $8.09{\times}10^8,\;9.14{\times}10^8$ and $1.03{\times}10^9/s$, and the kinetic orders are 1.37, 1.54 and 1.68, respectively. The optimum temperature range of the main peak for radiation dosimetry is between 220 and $290^{\circ}C$.

  • PDF

Evaluation of Photoneutron Energy Distribution in the Radiotherapy Room (방사선치료실 내의 광중성자 에너지 분포 평가)

  • Park, Euntae;Ko, Seongjin;Kim, Junghoon;Kang, Sesik
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.223-231
    • /
    • 2014
  • Medical linear accelerator is widely used in radiation treatment field, and high energy photons, above 10 MV nominal accelerator voltage, are commonly utilized for the radiation treatment. However, these high energy photons lead the photo-nuclear reaction and the generation of photo-neutrons are accompanied. Thus, these problematic factors are issued in the view of radiation protection. Therefore, linear accelerator and radiation treatment room are simulated from MCNPX program in this study. The measurement points of interest are selected and analyzed, and the resulting effects derived from the properties of photo-neutron are evaluated. Therefore, we realized that the number of generating photo-neutrons was decreased by depending on the distance from the source. No matter what the nominal energy is set, the rates thermal neutrons to fast neutrons are marginal. It is founded that the amount of the thermal neutrons were decreased by depending on the distance from the source.

Evaluation and Analysis of Scattered Radiation Dose according to Factors in General X-ray Examination (일반엑스선영상검사의 인자에 따른 산란방사선량 평가 및 분석)

  • Dong-Kyung Jung;Myeong-Hwan Park;Jeong-Min Seo
    • Journal of radiological science and technology
    • /
    • v.47 no.1
    • /
    • pp.13-19
    • /
    • 2024
  • Control of scattered radiation is one of very important factors in the use of medical radiation. In general X-ray exam, the causes, measurement methods, and the kind of detectors of scattered rays within the radiation area are diverse. In this study, the dose of scattered ray was measured by changing the thickness of the polycarbonate phantom and the tube voltage. As a result of measurement of scattered radiation, the results show that the scattered dose significantly(p<.05) increased with growing of thickness of phantom in the tube voltage 40, 50 and 60 kVp(F(p)<.05, R2>64%). As tube voltage increased at all phantom thicknesses, the scattered dose also significantly(p<.05) increased(F(p)<.05, R2>69%). In cases where a significant correlation was shown, the coefficient of determination of more than 60% was shown in regression analysis. The results of this study can be used as data on scattered radiation dose according to the tube voltage and the object thickness in general X-ray imaging exam.

The Correlation between Radiologic Findings and Clinicopathological Prognostic Factors in Small Peripheral Adenocarcinoma of Lung (말초 폐 발생 소형 선암에서 화상적 소견과 병리적, 임상적 예후와의 관계)

  • Park, Jae-Kil;Cho, Kyu-Do;Park, Kuhn;Moon, Seok-Whan;Rha, Suk-Joo;Choi, Si-Young;Jung, Jung-Im
    • Journal of Chest Surgery
    • /
    • v.37 no.5
    • /
    • pp.423-431
    • /
    • 2004
  • Background : Tumor size in lung cancer is not as good a prognostic factor for adenocarcinoma as it is for other types of lung cancer; therefore it is difficult to estimate the prognosis preoperative. However, there have recently been some reports on the radiologic findings correlating to the clinicopathologic prognostic factors in peripheral small adenocarcinoma of lung. We tried to evaluate the prognostic importance of High-Resolution CT (HRCT) findings of such adenoearcinoma, Material and Method: One houndred and seventy-six surgically resected small peripheral adenocarcinoma measuring 3 cm or less in greatest dimension were reviewed radiologically and clinicopathologically. Result: The patients with greater extent of ground-glass attenuation (GGA) had better clinico-pathological factors. The tumors with gross appearance of GGA or bubble-like shape showed better clinicopathological prognostic factors than scar-like or solid shape. Conclusion: HRCT findings of small peripheral adenocarcinomas of the lung correlated well with the histologic and clinical prognostic factors. We can predict the post-operative prognosis with the radiologic findings.

A Study Concerning of Servant Leadership of Radiotechnologist (방사선사의 서번트 리더십에 관한 고찰)

  • An, Hyun;Ko, Seong-Jin;Kang, Se-Sik;Kim, Dong-Hyun;Kim, Chang-Soo;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.35 no.3
    • /
    • pp.201-210
    • /
    • 2012
  • This study aimed to look at servant leadership that general radiotechnologist perceive from the servant leadership perspective and based on this to suggest ways to improve not only organizational effects of radiotechnologist who work clinically but also their working conditions. A population of 290 radiotechnologist who work at hospital in Pusan was the subject of this study and a survey was conducted to them. The analysis for the collected data used SPSS/PC+Win13 version and one-way, ANOVA was carried out to verify differences between groups. Servant leadership according to background factors showed relatively higher values among unmarried than married, twenties or more in terms of age, and nuclear medicine department in terms of the work department than other groups. Regular positions in terms of work types and university hospitals in terms of hospital types showed high scores, and as the motive for being a radiotechnologist, many considered job prospects. Hospitals should improve the organization's ability and performance by managing human resources efficiently. According to this study, servant leadership that radiotechnologist serve the community based on true prestige with basic honesty and trust as a member of fair community is a new model of true leadership that the future society requires.

A System Model of Iterative Image Reconstruction for High Sensitivity Collimator in SPECT (SPECT용 고민감도 콜리메이터를 위한 반복적 영상재구성방법의 시스템 모델 개발)

  • Bae, Seung-Bin;Lee, Hak-Jae;Kim, Young-Kwon;Kim, You-Hyun;Lee, Ki-Sung;Joung, Jin-Hun
    • Journal of radiological science and technology
    • /
    • v.33 no.1
    • /
    • pp.31-36
    • /
    • 2010
  • Low energy high resolution (LEHR) collimator is the most widely used collimator in SPECT imaging. LEHR has an advantage in terms of image resolution but has a difficulty in acquiring high sensitivity due to the narrow hole size and long septa height. Throughput in SPECT can be improved by increasing counts per second with the use of high sensitivity collimators. The purpose of this study is to develop a system model in iterative image reconstruction to recover the resolution degradation caused by high sensitivity collimators with bigger hole size. We used fan-beam model instead of parallel-beam model for calculation of detection probabilities to accurately model the high sensitivity collimator with wider holes. In addition the weight factors were calculated and applied onto the probabilities as a function of incident angle of incoming photons and distance from source to the collimator surface. The proposed system model resulted in the equivalent performance with the same counts (i.e. in shortened acquisition time) and improved image quality in the same acquisition time. The proposed method can be effectively applied for resolution improvement of pixel collimator of next generation solid state detectors.

A study on the impact of Professional burnout and job autonomy on turnover intention in radiologic technologists (방사선사의 업무소진과 업무자율성이 이직의사에 미치는 연구)

  • Hwang, Sang-Kyu;Jeong, Bong-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.267-275
    • /
    • 2011
  • The purpose of this study was to examine the impact of the professional burnout and job autonomy of radiologic technologists on their turnover intention in hospitals. The major findings of the study were as follows: As for the average and standard deviation of the radiologic technologists in professional burnout and job autonomy, they got a mean of 3.15 in overall professional burnout, which was above the average. They got 2.88 in job autonomy, which was below the average. And they got 3.30 in turnover intention, which indicated that they had a strong tendency to change jobs. Regarding the influential factors for turnover intention, emotional burnout, loss of interest and loss of enthusiasm were identified as the factors that exerted a significant influence on turnover intention. If the kind of environments that stimulate their professional enthusiasm and allow them to make a decision on radiographic examinations based on their own professional knowledge is created, their burnout will be minimized. And the development of programs geared toward bolstering their job autonomy is expected to weaken their turnover intention, to enhance the efficiency of the personnel administration of radiologic technologists and their qualifications, and ultimately to boost their status in hospital organizations.

The Influences of Bowel Condition with Lumbar Spine BMD Measurement (요추부 골밀도 측정 시 장내 변화가 골밀도에 미치는 영향)

  • Yoon, Joon;Kim, Yun-Min;Lee, Hoo-Min;Lee, Jung Min;Kwon, Soon-Mu;Cho, Hyung-Wook;Kang, Yeong-Han;Kim, Boo-Soon;Kim, Jung-Soo
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.273-278
    • /
    • 2014
  • Bone density measurement use of diagnosis of osteoporosis and it is an important indicator for treatment as well as prevention. But errors in degree of precision of BMD can be occurred by status of patient, bone densitometer and radiological technologist. Therefore the author evaluated that how BMD changes according to the condition of the patient. As Lumbar region, which could lead to substantial effects on bone density by diverse factors such as the water, food, intentional bowels. We recognized a change of bone mineral density in accordance with the height of the water tank and in the presence or absence of the gas using the Aluminum Spine Phantom. We also figured out the influence of bone mineral density by increasing the water and food into a target on the volunteers. Measured bone mineral density through Aluminum Spine Phantom had statistically significant difference accordance with increasing the height of water tank(p=0.026). There was no significant difference in BMD according to the existence of the bowl gas(p=0.587). There was no significant difference in a study of six people targeted volunteers in the presence or absence of the food(p=0.812). And also there was no significant difference according to the existence of water(p=0.618). If it is not difficult to recognize the surround of bone in measuring BMD of lumbar bone, it is not the factor which has the great effect on bone mineral density whether the test is after endoscopic examination of large intestine and patient's fast or not.

A Study of Factors that have Influence on the Length of Stay in the Emergency Room of Patients who have Acute Myocardial Infarction (응급실 급성심근경색증 환자의 체류시간에 영향을 미치는 요인에 관한 연구)

  • Joung, Hye-Gyoung;Kim, Hae-Joon;Yoon, Seok-Jun;Lee, June-Young;Lee, Heeyoung
    • Quality Improvement in Health Care
    • /
    • v.10 no.1
    • /
    • pp.42-56
    • /
    • 2003
  • Background : The purpose of this study is to investigate the influencing factors on the length of emergency department stay of patients with acute myocardial infraction. Methods : we reviewed medical records of all patients who were Hospitalized with acute myocardial infraction from March 1, 2002 to February 28, 2003. Results : The average length of stay in the emergency room of the subjects was 182.74 minutes. After the emergency room treatment, 48.1% of the subjects were transferred to intensive care unit. The hospitalization through emergency room mostly took place in the office hours. There were more patients on Monday. The influencing factors on the length of stay in the emergency room of patients with acute myocardial infraction were emergency room arrival time which was classified in seasons, treatment hours of specialized doctors, medical care insurance and required time of radiologic examination. Conclusion : In order to reduce the length of emergency room stay, it might be an available solution secure enough spaces, facility, and staff of the radiologic test only for the patients of the emergency room. And the effective use of emergency facility and space, establishment of standardized treatment guideline, and provision of emergency treatment support system are also needed.

  • PDF