• Title/Summary/Keyword: Radiologic evaluation

Search Result 337, Processing Time 0.025 seconds

The study of evaluation about the apron quality management and shield efficiency in 4 university laboratories of dae-gu, Kyungpook area (방사선(학)과 Apron 성능평가 및 관리 조사-대구, 경북지역 4개 대학교-)

  • Choi, Beom-Hee;Kim, Yong-Gug;Park, Seo-Hyun;Shin, Yong-Il;You, Young-Jun;Kim, Ye-Ri;Park, Chang-Hee
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.1
    • /
    • pp.47-54
    • /
    • 2013
  • This study evaluated the apron quality management and shield efficiency in the education laboratory for radiology students. For making a proposal of effective control of lead apron, Eighteen aprons, used in 4 university laboratories of dae-gu, Kyungpook area, were analyzed regarding their uniformities, transmission doses, lead equivalent and shield efficiencies. In conclusion, the lead apron uniformity was generally good. Also, the shield efficiency corresponding to lead equivalent was high. However, the quality control of lead apron was not satisfactory. Since there is a potentially possible chance for students to be exposed to a radiation during practical radiation-training in the education laboratory, the quality-control maintenance of the lead apron should be unceasingly maintained for the radiation protection.

  • PDF

Study on Clinical Practice Satisfaction by Students in Department of Radiologic Science (방사선(학)과 학생들의 임상실습만족도에 관한 연구)

  • Ko, Seong-Jin;Kang, Se-Sik;Kim, Chang-Soo;Choi, Seok-Yoon;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.287-296
    • /
    • 2011
  • Students enrolled in Department of Radiologic Science were surveyed on satisfaction of clinical practice. Purpose of the survey was to cultivate field-oriented talents capable of changing medical environment. Total 302 students in three-year and four-year school system were surveyed withSPSS/PC+ Win 13 version. Firstly, frequency analysis was used for distribution of general characteristics and clinical practice characteristics. Secondly, one-way analysis of variance was used to identify difference in the level of satisfaction based on variables. Thirdly, simple product-moment co-relation was used to analyze relations between variables. Among other variables, which include support to clinical practice class, instructors' expertise, practice subjects, practice environment, practice time, evaluation after practice and overall practice, students were most satisfied with overall practice, which was followed by practice subjects and time. This indicates high co-relation between factors affecting satisfaction of clinical practice education.

Dose and Image Assessment according to Radiologic Factors Variation at Digital Humerus X-ray Examination (디지털 환경에서 Humerus 검사 시 촬영인자 변화에 따른 선량 및 화질 평가)

  • Kim, Seong Min;Hong, Seon Sook;Lee, Kwan Sup;Ha, Dong Yun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.1-8
    • /
    • 2012
  • Purpose : We aim at presenting the optimum radiologic factor through the evaluation of dose variation and of image quality through the use of a grid in Humerus examination and the change of dose because of the change of radiologic factor. Materials and Methods : We divided it in 3 cases: when using a grid or not and when using IP(Image Plate) in a digital system. Also, as fixing kVp to 70kVp it changed mAs, and fixing mAs to 10 it changed kVp, we put up resolution chart and Burger rose phantom on the acrylic phantom of 7cm (the same level of Humerus) to evaluate the dose and image. We used Image J program to evaluate the quantitative resolution of the obtained image, and made the qualitative evaluation and statistical analysis of the image saved in PACS for 20 radiologic technologist with more than 10 years of experience in order of evaluate its contrast. We used SPSS10(SPSS Inc. Chicago, Illinois) for statistical analysis. Results : We observed the analytic result of resolution by the change of kVp that it was $4.539dGycm^2$ in 60kVp and $757.472dGycm^2$ in 75kVp, which increased about 64.6% of dose, while for the resolution it had the pixel value 30.7% better with 851 in 60kVp than 651 in 75kVp. Also, we analyzed the result of resolution by the change of mAs that it was $3.106dGycm^2$ in 5mAs, and $12.470dGycm^2$ in 20mAs, which increased about 400% of dose, while for the resolution DR had 678 in 5mAs, and 724 in 20mAs that increased about 6.8% of resolution. We made the qualitative evaluation of contrast by the change of kVp that DR showed the higher quality than CR, but the contrast by the change of kVp had no special different at the moment of visual evaluation, nor statistically significant difference(P>0.05). We observed the qualitative evaluation of contraste by the change of mAs that the contrast increased as DR increased mAs, and had statistically significant difference(P<0.05). On the other hand, CR had no significant difference for more than 10mAs nor statistically significant difference(P>0.05). Conclusion : In case of some patients with radiographic exposure by the repeated examination such as emergent patient or Follow up patient, they are considered to try to limit the use of a grid, to set kVp under 65kVp in fixed mode, to select less than 10mAs and to reduce the possibility of patient being bombed.

  • PDF

Analysis of Pineal Cyst ; Clinical and Radiological Characteristics (송과체 낭종의 임상적, 방사선학적 특성 분석)

  • Kim, Yong-Su;Jung, Shin;Yoon, Sang-Won;Lee, Jung-Kil;Kim, Tae-Sun;Kim, Jae-Hyoo;Kim, Soo-Han;Kang, Sam-Suk;Lee, Je-Hyuk
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.7
    • /
    • pp.899-903
    • /
    • 2000
  • Objective : Object : A 7-year retrospective clinical and MRI study was reviewed to evaluate the characteristics of pineal cyst. We evaluated results of clinical and radiologic change of pineal cyst during follow up period. Patients and Methods : From 1992 to 1999, 50 patients with pineal cyst were visited for evaluation. Follow up clinical information was obtained from patients or clinical record through phone conversation. also radiologic findi-ngs of pineal cyst in mid-sagittal MRI were reviewed in detail. Results : Pineal cysts were usually asymptomatic and detected incidentally during evaluation of other diseases. Sagittal MRI is the most useful diagnostic test. The radiologic findings of pineal cyst were isointensity on T1WI comared to CSF and slightly high signal intensity on T2WI. Cyst wall was variably enhanced on Gad-enhanced T1WI. The average size of cyst was $13.9{\times}13.0mm$. The pineal cyst was classified into five groups according to previous report. Long term behavior of these lesions are not apparent, but in our study they showed no specific changes in clinical and radiological aspects during 25 months. Conclusion : Although long-term follow up results are needed, the pineal cyst are considered as normal variants. In our 25 months follow up results, there was no rapid change of cyst both clinically and radiologically. Therefore, frequent radiologic evaluation seems unnecessary except type III pineal cyst.

  • PDF

Postoperative Evaluation of Funnel Chest - The role of radiologic indices -

  • 윤태진
    • Journal of Chest Surgery
    • /
    • v.25 no.12
    • /
    • pp.1416-1421
    • /
    • 1992
  • There are many objective indices of operative outcome of funnel chest, but there has been only a few report about the postoperative change of these indices and which is best correlated with subjective outcome. From January 1989 to December 1991, 74 patients with funnel chest underwent Ravitch operation and radiologic evaluation was performed on the twenty patients whose operative outcome were satisfactory by Humphreys` criteria and postoperative chest X-ray were available. Variable radiologic chest idices such as deformity grade [DG], lower vertebral index [LVI], upper vertebral index [UVI] and configuration index [CI] were measured preoperatively and 1, 6, 12 and 18 months pos-toperatively. The mean value of preoperative DG, LVI, UVI and CI were 5.32, 0.3, 0.26 and 1.01 respectively, and postoperative chages were as follows; DG; 3.13, 3.66, 3, 72, 4.0, LVI: 0.22, 0, 24, 0.25, 0.25 UVI; 0.27, 0.27, 0.27, 0.27 CI; 0.69, 0.77, 0.76, 0.79. The increments of CI were within the 90 percent confidence limit of normogram in most cases, but it was not true for LVI and UVI. And the differences between the observed and expected values of CI did not change significantly through the postoperative periods, which was not the case in LVI. We concluded from these results that 1] DG, LVI and CI were increased slowly during the postoperative follow up periods but the increments of CI were usually within the normal limits and so 2] CI can be used as a objective index of satisfactory outcome.

  • PDF

An Evaluation Method of X-ray Imaging System Resolution for Non-Engineers (비공학도를 위한 X-ray 영상촬영 시스템 해상력 평가 방법)

  • Woo, Jung-Eun;Lee, Yong-Geum;Bae, Seok-Hwan;Kim, Yong-Gwon
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.309-314
    • /
    • 2012
  • Nowadays, digital Radiography (DR) systems are widely used in clinical sites and substitute the analog-film x-ray imaging systems. The resolution of DR images depends on several factors such as characteristic contrast and motion of the object, the focal spot size and the quality of x-ray beam, x-ray scattering, the performance of the DR detector (x-ray conversion efficiency, the intrinsic resolution). The DR detector is composed of an x-ray capturing element, a coupling element and a collecting element, which systematically affect the system resolution. Generally speaking, the resolution of a medical imaging system is the discrimination ability of anatomical structures. Modulation transfer function (MTF) is widely used for the quantification of the resolution performance for an imaging system. MTF is defined as the frequency response of the imaging system to the input of a point spread function and can be obtained by doing Fourier transform of a line spread function, which is extracted from a test image. In clinic, radiologic technologists, who are in charge of system maintenance and quality control, have to evaluate or make routine check on their imaging system. However, it is not an easy task for the radiologic technologists to measure MTF accurately due to lack of their engineering and mathematical backgrounds. The objective of this study is to develop and provide for radiologic technologists a medical system imaging evaluation tool, so that they can measure and quantify system performance easily.