갈비연골속관절[늑연골속관절]은 우제류 갈비연골에 있는 윤활관절이다. 한국 고라니는 사슴과의 다른 동물과 다른 독특한 해부학적 구조를 지니고 있다. 그러나 한국 고라니 갈비연골속관절이 있는 곳과 그 형태에 관한 연구는 없다. 본 연구는 한국 고라니 갈비연골속관절에 대한 형태학적 자료를 제공하고자 육안관찰, 방사선사진 촬영, 컴퓨터 단층영상촬영(CT), 조직학적 관찰을 시행하였던 바, 갈비연골속관절은 주로 둘째에서 열째갈비연골에 이르기까지 존재하였으며 그 형태는 절구관절이었고, 이런 형태는 특히 셋째에서 여덟째 갈비연골속관절에서 뚜렷하였다. 이러한 결과는 한국고라니 가쪽가슴벽[외측흉벽]에 대한 진단과 처치에 도움을 줄 수 있을 것이다.
A four month old, intact female Jindo dog presented to the Veterinary Teaching Hospital of Kangwon National University with collapse. Physical examination revealed a heart rate of more than 200 beats per minute. Blood tests showed mild anemia and mild neutrophilia, while thoracic radiography and ultrasonography revealed no remarkable findings. Electrocardiography showed ventricular premature complexes (VPCs). The dog was diagnosed with congenital ventricular tachyarrhythmia. The condition was improved by lidocaine infusion. After 10 days, the dog was discharged from the hospital with a prescription of atenolol, pimobendan, diltiazem, furosemide, spironolactone, and L-carnitine. This dog is still alive after 31 months. However, progressive cardiac remodeling was confirmed on radiography and ultrasonography. Congenital ventricular tachyarrhythmia is rare in dogs, and the prognosis of reported cases is poor. This report describes the long-term successful management of a dog with congenital ventricular tachyarrhythmia.
A six months old, male Shih Tzu dog was referred to the Veterinary Medical Teaching Hospital at Kangwon National University, for lethargy, respiratory embarrassment. Survey radiography revealed enlarged cardiac silhouette due to displacement of gas-filled intestine in the pericardium. Although there were no specific clinical signs, this case was diagnosed as peritoneopericardial diaphragmatic hernia (PPDH) based on the results of positive contrast radiography and thoracic ultrasonograpic findings. In addition, the thickened gall bladder wall observed in ultrasonography, increase of alkaline phosphatase and neutrophils indicated cholecystitis. Two hepatic lobes and gall bladder were severely necrotized and adhere to the diaphragm. Direct reduction of the herniated organs might cause hepatic hemorrhage and bile juice leakage which may induce very poor prognosis. To solve the problems, the adhered organs were dissected with part of diaphragm, and lobectomy with cholecystectomy was performed for prevention of some possible complications including peritonitis. This is case report describing resection of part of diaphragm adhered to herniated organ reduce the risk of possible hepatic hemorrhage during surgical correction of PPDH followed bycholecystectomy and lobectomy.
선천성 횡격막 내장탈출은 드문 질환으로 산전 초음파로 횡격막 헤르니아와 감별하는 것은 쉽지 않다. 선천성 횡격막 내장탈출과 횡격막 헤르니아의 예후가 다르고 수술적 접근 방식이 다를 수 있어 정확한 감별 진단이 필요하다. 저자들은 산전 초음파 검사에서 선천성 횡격막 헤르니아로 진단되었으나 수술 시에 선천성 횡격막 내장탈출로 진단된 두 증례의 후향적 분석을 통하여 비록 출생 직후의 단순 흉부 사진으로는 두 질환의 감별 진단이 어려웠으나 연속적인 단순흉부사진에서 뚜렷하게 드러나는 병변 측 횡격막을 확인하는 경험을 하였다. 따라서 산전 초음파 검사에서 횡격막 헤르니아로 진단되었다 하더라도 출생 이후에 촬영한 연속적인 단순흉부사진의 주의 깊은 판독을 통한 재평가를 강조하고자 한다.
In this study, by analyzing the examination time for each procedure, the appropriate workload of radiologic technologist is analyzed based on the actual examination time in the current clinical setting by comparing with the examination time in the radiology field setting of the health insurance review and assessment service. In addition, this result is introduced into the calculation of relate value units; it was attempted to provide accurate and objective evidence in the field of radiology. From May 2020 to December 2021, the study retrospectively investigated the examination times recorded in the electronic medical record and picture archiving and communication system at 5 tertiary general hospitals and 1 general hospital. The total of 16 examination parts are applied in this study, including the head, sinuses, chest, ribs, abdomen, pelvis, cervical, thoracic, lumbar, shoulder, elbow, wrist, hip, femur, knee, and ankle. The minimum number of images that could be obtained per radiation generator was 3.6 images for one hour, and the maximum was 6.4 images. When 50% median of procedure time is calculated, the minimum number of images that could be obtained was 16.7 images and maximum was 35.3 images; in addition, minimum examination time is 1.7 minutes, and maximum time is 3.6 minutes. In conclusion, it is judged that there will be insufficient explanation time for basic infection instructions such as hand hygiene during the examinations in current clinical practice. It is believed that radiologic technologists will contribute to providing higher-quality of radiation examination services to the public by complying with guidelines for work and setting appropriate workload on their own.
Ye Ra Choi;Soon Ho Yoon;Jihang Kim;Jin Young Yoo;Hwiyoung Kim;Kwang Nam Jin
Tuberculosis and Respiratory Diseases
/
제86권3호
/
pp.226-233
/
2023
Background: Inactive or old, healed tuberculosis (TB) on chest radiograph (CR) is often found in high TB incidence countries, and to avoid unnecessary evaluation and medication, differentiation from active TB is important. This study develops a deep learning (DL) model to estimate activity in a single chest radiographic analysis. Methods: A total of 3,824 active TB CRs from 511 individuals and 2,277 inactive TB CRs from 558 individuals were retrospectively collected. A pretrained convolutional neural network was fine-tuned to classify active and inactive TB. The model was pretrained with 8,964 pneumonia and 8,525 normal cases from the National Institute of Health (NIH) dataset. During the pretraining phase, the DL model learns the following tasks: pneumonia vs. normal, pneumonia vs. active TB, and active TB vs. normal. The performance of the DL model was validated using three external datasets. Receiver operating characteristic analyses were performed to evaluate the diagnostic performance to determine active TB by DL model and radiologists. Sensitivities and specificities for determining active TB were evaluated for both the DL model and radiologists. Results: The performance of the DL model showed area under the curve (AUC) values of 0.980 in internal validation, and 0.815 and 0.887 in external validation. The AUC values for the DL model, thoracic radiologist, and general radiologist, evaluated using one of the external validation datasets, were 0.815, 0.871, and 0.811, respectively. Conclusion: This DL-based algorithm showed potential as an effective diagnostic tool to identify TB activity, and could be useful for the follow-up of patients with inactive TB in high TB burden countries.
Soon Ho Yoon;Kyung Hee Lee;Jin Yong Kim;Young Kyung Lee;Hongseok Ko;Ki Hwan Kim;Chang Min Park;Yun-Hyeon Kim
Korean Journal of Radiology
/
제21권4호
/
pp.494-500
/
2020
Objective: This study presents a preliminary report on the chest radiographic and computed tomography (CT) findings of the 2019 novel coronavirus disease (COVID-19) pneumonia in Korea. Materials and Methods: As part of a multi-institutional collaboration coordinated by the Korean Society of Thoracic Radiology, we collected nine patients with COVID-19 infections who had undergone chest radiography and CT scans. We analyzed the radiographic and CT findings of COVID-19 pneumonia at baseline. Fisher's exact test was used to compare CT findings depending on the shape of pulmonary lesions. Results: Three of the nine patients (33.3%) had parenchymal abnormalities detected by chest radiography, and most of the abnormalities were peripheral consolidations. Chest CT images showed bilateral involvement in eight of the nine patients, and a unilobar reversed halo sign in the other patient. In total, 77 pulmonary lesions were found, including patchy lesions (39%), large confluent lesions (13%), and small nodular lesions (48%). The peripheral and posterior lung fields were involved in 78% and 67% of the lesions, respectively. The lesions were typically ill-defined and were composed of mixed ground-glass opacities and consolidation or pure ground-glass opacities. Patchy to confluent lesions were primarily distributed in the lower lobes (p = 0.040) and along the pleura (p < 0.001), whereas nodular lesions were primarily distributed along the bronchovascular bundles (p = 0.006). Conclusion: COVID-19 pneumonia in Korea primarily manifested as pure to mixed ground-glass opacities with a patchy to confluent or nodular shape in the bilateral peripheral posterior lungs. A considerable proportion of patients with COVID-19 pneumonia had normal chest radiographs.
Radiographic left atrial dimension (RLAD) is a valuable metric for assessing left atrial enlargement in dogs. While there have been studies on the use of RLAD and the increase in C-reactive protein (CRP) levels based on heart disease stages, there has been no prior research on the correlation between RLAD and CRP. In this study, the objective was to investigate the relationship between the rise in RLAD as myxomatous mitral valve disease (MMVD) stages advance and the increase in CRP levels with MMVD stage progression. In this study, a total of 30 small-breed dogs were included as subjects. These dogs were diagnosed with MMVD at the American College of Veterinary Internal Medicine (ACVIM) stage B1 or B2, or stage C, based on a comprehensive assessment including physical examination, thoracic radiography, and echocardiography. Measurements of VHS and RLAD were compared to assess any significant differences. There were significant differences in RLAD between dogs with MMVD ACVIM stage B1 and those with stage C. The monocytes and CRP levels showed significant differences between ACVIM stage B1, B2 and ACVIM C. Additionally, a significant correlation was observed between the RLAD and VHS measurements. This underscores the notable association between MMVD stage advancement and elevated monocyte and CRP levels. The RLAD scores exhibited a significant difference among dogs with ACVIM stages B1, B2, and C, and significant variations were also observed in monocyte and CRP levels. These results suggest that monocyte and CRP levels may be a valuable diagnostic indicator for heart disease in dogs during the diagnostic evaluation.
The purpose of this study is to present the reference values for cardiac size and cardiothoracic ratio change, normal range and diagnosis of cardiovascular disease in pregnancy and non pregnancy of normal Korean women using chest X-ray. The subjects of this study were 58 women, who were read as normal by chest radiologist, had chest radiography taken on both last month of pregnancy, pre-pregnancy and within 2 years following delivery. In this study, we defined the last month of pregnancy as pregnancy and before or post pregnancy as non-pregnancy. CS and CTR were measured by two radiological technologist who had clinical experience more ten years with Danzer's method. Statistical methods were paired t-test and one-way ANOVA. Significance level ${\alpha}$ was 0.05 and p-value 0.05 or less was statistically significant. For pregnancy, the mean of left and right cardiac size was $40.11{\pm}8.73mm$ and $89.51{\pm}11.9mm$, CS was $128.60{\pm}13.15mm$, CTR was $44.51{\pm}4.21%$. In non pregnancy, $36.50{\pm}8.18mm$ and $77.68{\pm}13.1mm$. CS and CTR were $114.18{\pm}14.28mm$ and $42.03{\pm}4.04%$. Both pregnancy and non pregnancy, the difference of the mean value in left and right cardiac size, CS and CTR were statistically significant (p<0.01). but comparing mean on age, height and weight, the difference of the mean value between groups was not (p>0.05). In the result of this study, the mean size of CS increased by 12.6% in pregnancy($128.60{\pm}13.15mm$) compared to the non pregnancy($114.18{\pm}14.28mm$), and increased by 9.8% in the right side of the heart and 15.2% in the left side. The mean size of CTR increased about 5.9% in pregnancy ($44.5{\pm}4.21%$) compared to non pregnancy($42.03{\pm}4.04%$).
This study aims to present new chest AP examination exposure conditions through a study on the effect on image quality and patient dose by applying high tube voltage and scatter ray post-processing software during chest AP examination in digital radiography equipment. This study was used a human body phantom and in the chest AP position, the dosimeter was placed horizontally at the thoracic spine 6. The experiment was conducted by dividing into a low tube voltage (70 kVp, 400 mA, 3.2 mAs) group and a high tube voltage (100 kVp, 400 mA, 1.2 mAs) group. The collimation size (14″× 17″) and the source to image receptor distance(110 cm) were same applied to both groups. Radiation dose was presented to dose area product and entrance surface dose. Image quality was compared and analyzed by comparing the difference between the signal-to-noise ratio and the contrast-to-noise ratio of the image according to the application of the scatter ray post-processing software under each condition. The average value of the entrance surface dose in the low and high tube voltage conditions was 93.04±0.45 µGy and 94.25±1.51 µGy, which was slightly higher in the high tube voltage condition, but the dose area product was 0.97±0.04 µGy and 0.93±0.01 µGy. There was a statistically significant difference in the group mean value(p<0.01). In terms of image quality, the values of the signal-to-noise ratio and the contrast noise ratio were higher in the high tube voltage than in the low tube voltage, and decreased when the scattering line post-processing function was used, but the contrast resolution was improved. If there is a scatter ray post-processing function during chest AP examination, it is helpful to actively utilize it to improve the image quality. However, when this function is not available, I thought that applying a higher tube voltage state than a low tube voltage state will help to realize images with a large amount of information without changing the dose.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.