• 제목/요약/키워드: Radiography, Panoramic

검색결과 293건 처리시간 0.028초

파노라마방사선사진에서의 하악관의 각도와 이공의 위치에 관한 연구 (A study of mandibular canal angle and location of mental foramen on the panoramic radiograph)

  • 최항문
    • Imaging Science in Dentistry
    • /
    • 제39권2호
    • /
    • pp.89-92
    • /
    • 2009
  • Purpose: To assess the angle between mandibular canal and occlusal plane at each posterior tooth region and location of mental foramen on the panoramic radiographs. Materials and Methods: This study analysed 46 half-mandibles of panoramic radiographs. Inferior border of mandibular canal was traced. Occlusal plane was drawn from lingual cusp tip of the first premolar to distolingual cusp tip of the second molar. Perpendicular line from occlusal plane was drawn at each tooth region and then tangential lines were drawn from the crossing points at canal. the angle between occlusal plane and tangential line was measured. The location of mental foramen was also studied. According to the location of mental foramen, radiographs were divided into M (mesial) group and D (distal) group on the basis of the second premolar. and then inter-group analysis about mandibular canal angle was done. Results: The angles of mandibular canals were -17.7$^{\circ}$, -9.5$^{\circ}$, 8.2$^{\circ}$, 22.3$^{\circ}$, and 39.2$^{\circ}$at first premolar, second premolar, first molar, second molar, and third molar, respectively. The commonest position of the mental foramen was distal to the second premolar. Inter-group comparison showed statistically significant difference at the second premolar and the first molar(p<0.001). Conclusion: The knowledge of mandibular canal angle and location of mental foramen can help understanding the course of mandibular canal. (Korean J Oral Maxillofac Radiol 2009; 39: 89-92)

  • PDF

Orthodontic diagnosis rates based on panoramic radiographs in children aged 6-8 years: A retrospective study

  • You-Sun Lee;Ji-Yeon Lee
    • 대한치과교정학회지
    • /
    • 제54권3호
    • /
    • pp.185-195
    • /
    • 2024
  • Objective: This study aimed to retrospectively analyze the prevalence of orthodontic problems and the proportion of patients who underwent orthodontic diagnosis among children aged 6 (n = 300), 7 (n = 400), and 8 (n = 400) years who had undergone panoramic radiography. Methods: Children were divided into five groups according to their chief complaint and consultation: conservative dentistry, oral and maxillofacial surgery, orthodontics, periodontics, and prosthodontics). Chief complaints investigated included first molar eruption, lack of space for incisor eruption, frequency of eruption problems, lack of space, impaction, supernumerary teeth (SNT), missing teeth, and ectropion eruption. The number of patients whose chief complaint was not related to orthodontics but had dental problems requiring orthodontic treatment was counted. The proportion of patients with orthodontic problems who received an orthodontic diagnosis was also examined. Results: Dental trauma and SNT were the most frequent chief complaints among the children. The proportion of patients with orthodontic problems increased with age. However, the orthodontic diagnosis rates based on panoramic radiographs among children aged 6, 7, 8 years were only 1.5% (6 years) and 23% (7 and 8 years). Conclusions: Accurate information should be provided to patient caregivers to correct misconceptions regarding the appropriateness of delaying orthodontic examination until permanent dentition is established.

Does cone-beam CT alter treatment plans? Comparison of preoperative implant planning using panoramic versus cone-beam CT images

  • Guerrero, Maria Eugenia;Noriega, Jorge;Castro, Carmen;Jacobs, Reinhilde
    • Imaging Science in Dentistry
    • /
    • 제44권2호
    • /
    • pp.121-128
    • /
    • 2014
  • Purpose: The present study was performed to compare the planning of implant placement based on panoramic radiography (PAN) and cone-beam computed tomography (CBCT) images, and to study the impact of the image dataset on the treatment planning. Materials and Methods: One hundred five partially edentulous patients (77 males, 28 females, mean age: 46 years, range: 26-67 years) seeking oral implant rehabilitation were referred for presurgical imaging. Imaging consisted of PAN and CBCT imaging. Four observers planned implant treatment based on the two-dimensional (2D) image data-sets and at least one month later on the three-dimensional (3D) image dataset. Apart from presurgical diagnostic and dimensional measurement tasks, the observers needed to indicate the surgical confidence levels and assess the image quality in relation to the presurgical needs. Results: All observers confirmed that both imaging modalities (PAN and CBCT) gave similar values when planning implant diameter. Also, the results showed no differences between both imaging modalities for the length of implants with an anterior location. However, significant differences were found in the length of implants with a posterior location. For implant dimensions, longer lengths of the implants were planned with PAN, as confirmed by two observers. CBCT provided images with improved scores for subjective image quality and surgical confidence levels. Conclusion: Within the limitations of this study, there was a trend toward PAN-based preoperative planning of implant placement leading towards the use of longer implants within the posterior jaw bone.

Radiographic evaluation of the zygomatic air cell defect

  • Park Young-Hee;Lee Soo-Kyung;Park Byeong-Hyun;Son Hyo-Sun;Choi Mi;Choi Karp-Shik;An Chang-Hyeon
    • Imaging Science in Dentistry
    • /
    • 제32권4호
    • /
    • pp.207-211
    • /
    • 2002
  • Purpose : The purpose of this study was to determine the prevalence, radiographic appearance, and characteristics of patients with zygomatic air cell defect (ZACD), and to give recommendations concerning radiographic evaluation and surgery. Materials and Methods: Routine panoramic radiographs of 1,400 patients admitted to the Kyungpook National University Hospital Dental Clinic, were retrospectively examined for the clinical and radiographic features of ZACD. Results: ZACD was found in 31 cases, representing a prevalence of 2.2%. Patients with ZACD had a mean age of 27.5 years and a range of 9-52 years. Most ZACD cases were in their thirties. ZACD showed a strong male prediliction, 22 of the 31 subjects were males and 9 were females. Twenty-four cases of ZACD (77.4%) were unilateral, with the half occurring on the right side. In seven cases (22.6%), ZACD was bilateral. Twenty-six (68.4%) of the defects were of unilocular, while twelve (31.6%) of the defects were multilocular. Conclusion: Knowledge of ZACD may be helpful in interpreting images, including panoramic radiographs, in planning surgical treatment of the TMJ and in understanding the spread of pathological processes into the joint.

  • PDF

Dental students' ability to detect maxillary sinus abnormalities: A comparison between panoramic radiography and cone-beam computed tomography

  • Rosado, Lucas de Paula Lopes;Barbosa, Izabele Sales;de Aquino, Sibele Nascimento;Junqueira, Rafael Binato;Verner, Francielle Silvestre
    • Imaging Science in Dentistry
    • /
    • 제49권3호
    • /
    • pp.191-199
    • /
    • 2019
  • Purpose: To compare the diagnostic ability of undergraduate dental students to detect maxillary sinus abnormalities in panoramic radiographs(PR) and cone-beam computed tomography (CBCT). Materials and Methods: This was a retrospective study based on the evaluation of PR and CBCT images. A pilot study was conducted to determine the number of students eligible to participate in the study. The images were evaluated by 2 students, and 280 maxillary sinuses were assessed using the following categories: normal, mucosal thickening, sinus polyp, antral pseudocyst, nonspecific opacification, periostitis, antrolith, and antrolith associated with mucosal thickening. The reference standard was established by the consensus of 2 oral radiologists based on the CBCT images. The kappa test, receiver operating characteristic curves, and 1-way analysis of variance with the Tukey-Kramer post-hoc test were employed. Results: Intraobserver and interobserver reliability showed agreement ranging from substantial (0.809) to almost perfect (0.922). The agreement between the students' evaluations and the reference standard was reasonable (0.258) for PR and substantial(0.692) for CBCT. Comparisons of values of sensitivity, specificity, and accuracy showed that CBCT was significantly better(P<0.05). Conclusion: CBCT was better than PR for the detection of maxillary sinus abnormalities by dental students. However, CBCT should only be requested after a careful analysis of PR by students and more experienced professionals.

Evaluation of the accuracy of linear and angular measurements on panoramic radiographs taken at different positions

  • Nikneshan, Sima;Sharafi, Mohamad;Emadi, Naghmeh
    • Imaging Science in Dentistry
    • /
    • 제43권3호
    • /
    • pp.191-196
    • /
    • 2013
  • Purpose: This study assessed the accuracy of linear and angular measurements on panoramic radiographs taken at different positions in vitro. Materials and Methods: Two acrylic models were fabricated from a cast with normal occlusion. Straight and $75^{\circ}$ mesially and lingually angulated pins were placed, and standardized panoramic radiographs were taken at standard position, at an $8^{\circ}$ downward tilt of the occlusal plane compared to the standard position, at an $8^{\circ}$ upward tilt of the anterior occlusal plane, and at a $10^{\circ}$ downward tilt of the right and left sides of the model. On the radiographs, the length of the pins above (crown) and below (root) the occlusal plane, total pin length, crown-to-root ratio, and angulation of pins relative to the occlusal plane were calculated. The data were subjected to repeated measures ANOVA and LSD multiple comparisons tests. Results: Significant differences were noted between the radiographic measurements and true values in different positions on both models with linear (P<0.001) and those with angulated pins (P<0.005). No statistically significant differences were observed between the angular measurements and baselines of the natural head posture at different positions for the linear and angulated pins. Conclusion: Angular measurements on panoramic radiographs were sufficiently accurate and changes in the position of the occlusal plane equal to or less than $10^{\circ}$ had no significant effect on them. Some variations could exist in the pin positioning (head positioning), and they were tolerable while taking panoramic radiographs. Linear measurements showed the least errors in the standard position and $8^{\circ}$ upward tilt of the anterior part of the occlusal plane compared to other positions.

치과 임플란트 수술 계획시 CT를 이용한 상악동 체적 및 치조골량 측정 (Measurement of maxillary sinus volume and available alveolar bone height using computed tomography)

  • 이재학;한원정;최영희;김은경
    • Imaging Science in Dentistry
    • /
    • 제33권1호
    • /
    • pp.35-41
    • /
    • 2003
  • Purpose: To aid in determining the volume of graft bone required before a maxillary sinus lift procedure and compare the alveolar bone height measurements taken by panoramic radiographs to those by CT images. Materials and Methods : Data obtained by both panoramic radiographs and CT examination of 25 patients were used in this study. Maxillary sinus volumes from the antral floor to heights of 5 mm, 10 mm, 15 mm, and 20 mm, were calculated. Alveolar bone height was measured on the panoramic images at each maxillary tooth site and corrected by magnification rate (PBH). Available bone height (ABH) and full bone height (FBH) was measured on reconstructed CT images. PBH was compared with ABH and FBH at the maxillary incisors, canines, premolars, and molars. Results: Volumes of the inferior portion of the sinuses were 0.55 ± 0041 ㎤ for 5 mm lifts, 2.11 ± 0.68 ㎤ for 10 mm, 4.26 ± 1.32 ㎤ for 15 mm, 6.95 ± 2.01 ㎤ for 20 mm. For the alveolar bone measurement, measurements by panoramic images were longer than available bone heights determined by CT images at the incisor and canine areas, and shorter than full bone heights on CT images at incisor, premolar, and molar areas (p<0.001). Conclusion: In bone grafting of the maxillary sinus floor, 0.96 ㎤ or more is required for a 5 mm-lift, 2.79 ㎤ or more for a 10 mm-lift, 5.58 ㎤ or more for a 15 mm-lift, and 8.96 ㎤ or more for a 20 mm-lift. Maxillary implant length determined using panoramic radiograph alone could result in underestimation or overestimation, according to the site involved.

  • PDF

Head and neck radiotherapy-induced changes in dentomaxillofacial structures detected on panoramic radiographs: A systematic review

  • Munhoz, Luciana;Nishimura, Danielle Ayumi;Iida, Christyan Hiroshi;Watanabe, Plauto Christopher Aranha;Arita, Emiko Saito
    • Imaging Science in Dentistry
    • /
    • 제51권3호
    • /
    • pp.223-235
    • /
    • 2021
  • Purpose: This study aimed to summarize the impact of neck and head radiation treatment on maxillofacial structures detected on panoramic radiographs. Materials and Methods: In this systematic review, the authors searched PubMed Central, Embase, Scopus, Cochrane Central Register of Controlled Trials, Web of Science, and Google Scholar for original research studies up to February 2020 that included the following Medical Subject Headings keywords: words related to "radiotherapy" and synonyms combined with keywords related to "panoramic radiography" and "oral diagnosis" and synonyms. Only original studies in English that investigated the maxillofacial effects of radiotherapy via panoramic radiographs were included. The quality of the selected manuscripts was evaluated by assessing the risk of bias using Cochrane's ROBINS-I tool for non-randomized studies. Results: Thirty-three studies were eligible and included in this review. The main objectives pertained to the assessment of the effects of radiation on maxillofacial structures, including bone architecture alterations, periodontal space widening, teeth development abnormalities, osteoradionecrosis, and implant bone loss. The number of participants evaluated ranged from 8 to 176. Conclusion: The interaction between ionizing radiation and maxillofacial structures results in hazard to the tissues involved, particularly the bone tissue, periosteum, connective tissue of the mucosa, and endothelium. Hard tissue changes due to radiation therapy can be detected on panoramic radiographs.

Convolutional neural networks for automated tooth numbering on panoramic radiographs: A scoping review

  • Ramadhan Hardani Putra;Eha Renwi Astuti;Aga Satria Nurrachman;Dina Karimah Putri;Ahmad Badruddin Ghazali;Tjio Andrinanti Pradini;Dhinda Tiara Prabaningtyas
    • Imaging Science in Dentistry
    • /
    • 제53권4호
    • /
    • pp.271-281
    • /
    • 2023
  • Purpose: The objective of this scoping review was to investigate the applicability and performance of various convolutional neural network (CNN) models in tooth numbering on panoramic radiographs, achieved through classification, detection, and segmentation tasks. Materials and Methods: An online search was performed of the PubMed, Science Direct, and Scopus databases. Based on the selection process, 12 studies were included in this review. Results: Eleven studies utilized a CNN model for detection tasks, 5 for classification tasks, and 3 for segmentation tasks in the context of tooth numbering on panoramic radiographs. Most of these studies revealed high performance of various CNN models in automating tooth numbering. However, several studies also highlighted limitations of CNNs, such as the presence of false positives and false negatives in identifying decayed teeth, teeth with crown prosthetics, teeth adjacent to edentulous areas, dental implants, root remnants, wisdom teeth, and root canal-treated teeth. These limitations can be overcome by ensuring both the quality and quantity of datasets, as well as optimizing the CNN architecture. Conclusion: CNNs have demonstrated high performance in automated tooth numbering on panoramic radiographs. Future development of CNN-based models for this purpose should also consider different stages of dentition, such as the primary and mixed dentition stages, as well as the presence of various tooth conditions. Ultimately, an optimized CNN architecture can serve as the foundation for an automated tooth numbering system and for further artificial intelligence research on panoramic radiographs for a variety of purposes.

구강검진의 효과 증진을 위한 파노라마방사선사진의 필요성에 관한 연구 (Usefullness of panoramic radiograph for the improvement of periodic oral examination)

  • 신민정;최보람;허경회;이원진;허민석;이삼선;최순철
    • Imaging Science in Dentistry
    • /
    • 제40권1호
    • /
    • pp.25-32
    • /
    • 2010
  • Purpose : This study was designed to evaluate the efficacy and utility of panoramic radiograph for the improvement of the periodic oral examinations. Materials and Methods : Clinical examinations and panoramic examinations were done for the 242 subjects of oral examinations. The results of panoramic radiograph interpretation were compared with the clinical findings. Two questionnaires were created. One was carried out before the panoramic examination and the other done afterwards, to find out the subjects' cognition and satisfaction for the clinical and panoramic examinations. Results : 1. Panoramic findings showed a higher detection rate of 31.9% for periodontal diseases, and 23.1% for dental caries than clinical findings. 2. The additional abnormalities detected through panoramic examinations were impacted tooth in 81 subjects (33.6%), maxillary sinus abnormalities in 28 subjects (11.6%), condylar abnormalities in 5 subjects (2.1%), congenital and acquired dental anormalies in 59 subjects (24.5%), and other miscellaneous abnormalities in 34 subjects (14.1%). 3. 164 subjects (67.8%) were satisfied with the current periodic oral examination, and 75 subjects (31.1%) hoped for better accuracy. 4. In the first and second questionnaire, 154 subjects (67.0%) and 163 subjects (70.6%) responded respectively that panoramic examination was necessary, and 193 subjects (83.2%) responded that it actually helped. Conclusion : The panoramic examination was revealed to improve the effectiveness of the periodic oral examination and to increase the satisfaction of the subjects of examination.