저자는 파노라마 방사선사진을 이용하여 악관절 진단시에 진단학적 유용성을 알아보기 위하여 5개의 건조 두개골을 대상으로 하악과두의 4부위에 자각 인위적으로 형성한 골편을 부착시켜 피사체를 통상적인 위치, 전방으로 25㎜ 이동시킨 위치 및 전후 반대방향으로 위치시킨 상태에서 촬영하여 그 상을 비교하여 다음과 같은 결론을 얻었다. 피사체가 통상적인 위치에 있을 경우에는 골증식체가 전외부와 전중부에 있을 때 전내부와 상방부에 있을 때보다 관찰이 용이하였다 (p<0.01). 피사체가 25㎜ 전방이동한 경우에는 골증식체가 전중부와 전내부에 있을 때 전외부와 상방부에 있을 때보다 관찰이 용이하였다. (p<0.05). 피사체가 반대방향으로 위치한 경우에는 골증식체가 전중부에 있을 때 타부위에서보다 관찰이 용이 하였다 (p<0.05)
The author has examined the abnormalities in panoramic radiographs of 668 edentulous patients. The distribution, type, incidence, and location of all abnormalities were analized, and the distances between alveolar crest and anatomical structures were measures. (Maxillary measurements were performed between alveolar crest and lower margin of the maxillary sinus and mandibular measurements between alveolar crest and upper edge of the mental foramen.) The obtained results were as follows: 1. Of the 668 panoramic radiographs examined, 103(15.4%) showed one or more abnormalities. 2. The incidence of abnormalities was decreased by years, which was 22.0% in 1970's and 16.8% in 1980's and 12.1 % in 1990's. 3. The distribution of abnormalities as follows; 43 (40.2%) superficial root fragments, 24(22.4%) impacted teeth, 9(8.4%) imbedded root fragments, 7 (6.5%) cysts, 7(6.5%) fractures, 5(4.7%) foreign bodies, 5(4.7%) abnormal radiolucencies, 4(3.7%) abnormal radiopacities, 2(1.9%) bony defects, 1(0.9%) tumor. 4. In the location of abnormalities, 42 cases (35.3%) were in the maxillary posterior region, 26 cases(21.8%) were in the maxillary anterior region, 20 cases(24.4%) were in the mandibular posterior region and 18 cases(15.1%) were in the mandibular anterior region. 5. In the distance between alveolar crest and maxillary sinus, 109 cases(9.7%) were below 0.5㎜, 757 cases(67.6%) were between 0.5㎜ and 10㎜, 254 cases(22.7%) were above 10㎜. In the distance between alveolar crest and mental foramen, 73 cases (8.8%) were below 0.5㎜, 501 cases (60.7%) were between 0.5㎜ and l0㎜ and 252 cases(30.5%) were above 100㎜.
We sought to evaluate the relationship between the mandibular canal and impacted mandibular third molars by using dental cone beam computed tomograph(CBCT) for third molar surgery. A total of 111 patients(177 teeth) offered the images through CBCT and panoramic radiography for the extraction of the mandibular third molars. In CBCT, the accurate relationship between the third molar and the mandibular canal were evaluated. In panoramic radiographies, we evaluated the impacted level and superimposition sign of the mandibular third molar with the mandibular canal, and also, the radiopacity of the white line in the canal. Data were statistically analyzed and estimated by $X^2$-test. In CBCT finding, high prevalence of contact between the mandibular canal and roots occured in the deep impacted third molars, narrowing mandibular canals, bending mandibular canals and cases where the radiopacity of white line of canals were "absence" on panoramic images. It showed statistical significance (P<0.05). When evaluating the mandibular canal and the roots through the panoramic radiography for third molar extraction, it could be difficult to diagnosis accurately. Thus, it is required to have an accurate diagnostic approach through CBCT that could evaluated the location between mandibular canal and root.
Purpose: To determine the impact of an image processing technique on diagnostic accuracy of digital panoramic radiographs for the assessment of anatomical structures in paediatric patients with mixed dentition. Materials and Methods: The study consisted of 50 digital panoramic radiographs of children aged from 6 to 12 years, which were later on processed using a dedicated image processing method. A modified clinical image quality evaluation chart was used to evaluate the diagnostic accuracy of anatomical structures in maxillary and mandibular anterior and maxillary premolar region of processed images. Results: A statistically significant difference was observed between pre and post-processed evaluation of anatomical structures(P<0.05) in the maxillary and mandibular anterior region. The anterior region was found to be more accurate in post-processed images. No significant difference was observed in the maxillary premolar region (P>0.05). The Inter-observer and intra-observer reliability of both pre and post processed images were excellent (>0.82) for anterior region and good (>0.63) for premolar region. Conclusion: The application of image processing technique in digital panoramic radiography can be considered a reliable method for improving the quality of anatomical structures in paediatric patients with mixed dentition.
Purpose: The objective of this study was to estimate the radiation absorbed doses in certain critical organs in the head and neck region with 16 imaging programs available on the Orthopos/sup (R)/ panoramic machine. Materials and Methods: A Rando phantom and LiF TLD chips were used for dosimetry. The absorbed doses were measured at the thyroid gland, the submandibular gland, the parotid gland, the mouth floor. the maxillary sinus, the brain, the mandibular body, the mandibular ramus. the 2nd cervical spine and the skin over TMJ area. Results : The overall absorbed doses with imaging programs available on the Orthopos/sup (R)/ panoramic machine were much less than that of standard program (program 1) except program 8, 11, and 16. Generally, the absorbed doses to the bone marrow of the mandibular ramus and the parotid gland were high, but the absorbed doses to the bone marrow in the mandibular body, brain, maxillary sinus, and, especially, the thyroid gland were very low. Conclusion : The modified imaging programs available on the Orthopos/sup (R)/ panoramic machine can be effectively used in aspect of radiation protection.
Purpose: This study was performed to investigate the interobserver agreement on the detection of carotid artery calcifications on panoramic radiographs. Materials and Methods: This study consisted of panoramic radiographs acquired from 634 male patients of the age of 50 years or older. Having excluded carotids of no diagnostic quality, 1008 carotids from the panoramic radiographs of the patients were interpreted by two oral and maxillofacial radiologists independently for the presence of carotid artery calcifications. Statistical analysis was used to calculate the interobserver agreement. Results: Interobserver agreement was obtained for 932 carotids (92.4%). Inconsistent interpretation of 76 carotids (7.5%) between the two observers was found. Cohen's kappa value was 0.688 (p<0.001). Conclusion: The probability of a match between the two observers was substantially high.
Purpose: The purpose of this study was to investigate whether panoramic radiographs were useful in predicting osteoporosis. Materials and Methods: 50 postmenoposal women between the age of 41.8 and 78.5 were classified as normal and osteoporosis groups according to the bone mineral density of lumbar vertebrae. Panoramic radiographs were taken. Age, body mass index, remaining mandibular teeth, mandibular cortical thickness and morphology, and fractal dimensions at periapical areas of mandibular first molars were evaluated to differentiate the two groups. Results: The age of osteoporotic group was statistically significantly higher than that of normal group (p<0.05), but not the body mass index or number of remaining mandibular teeth. The mean fractal dimension of osteoporotic group was $1.391{\pm}0.085$, and was significantly lower than that of the normal group, which was $1.523{\pm}0.725$ (p<0.01). Thick mandibular cortical thickness was common in normal group, whereas thin or very thin mandibular cortical thickness was common in osteoporotic group and the difference was significant (p < 0.05). C2 pattern was common in normal group followed by C1, whereas C2 was common in osteoporotic group followed by C3. The difference was statistically significant (p< 0.0 1). Conclusion: Age, mandibular cortical thickness and shape, fractal dimension on panoramic radiographs were useful in predicting osteoporosis.
Journal of the Korean Association of Oral and Maxillofacial Surgeons
/
제48권4호
/
pp.219-224
/
2022
Objectives: There have been few studies to date on the residual effect of bisphosphonate. This study investigated the radiographic changes of mandibular cortical thickness upon bisphosphonate drug holiday. Materials and Methods: This retrospective study includes 36 patients diagnosed with MRONJ (medication-related osteonecrosis of the jaw) at Ajou University Dental Hospital in 2010-2021. All patients stopped taking bisphosphonate under consultation with the prescribing physicians. Panoramic radiographs were taken at the start of discontinuation (T0), 12 months after (T1), and 18 months after (T2) discontinuation of bisphosphonate, respectively. Mental index and panoramic mandibular index were calculated using Ledgerton's method. Paired t-tests were used to analyze differences over time. Results: The difference in indices (mental index and panoramic mandibular index) between T0 and T1 was not statistically significant (paired t-test, P>0.05). However, the difference in these indices between T1 and T2 was statistically significant (paired t-test, P<0.05). Conclusion: The cortical thickness of the mandible decreased in the late stage (after 18 months) as observed by panoramic radiograph.
Alif, Sheikh Mohammad;Haque, Sejuty;Nimmi, Naima;Ashraf, Ali;Khan, Saeed Hossain;Khan, Mahfujul Haq
Imaging Science in Dentistry
/
제41권4호
/
pp.155-159
/
2011
Purpose : This study was performed to determine the prevalence of maxillary canine impaction on a basis of a single panoramic radiograph in Bangladeshi population. Materials and Methods : A random sample of seven hundred panoramic radiographs was collected from the patient record of a dental clinic. All the selected panoramic radiographs were taken from January 2009 to August 2010 by a single panoramic radiograph machine with the same exposure time (19 seconds) for all radiographs. One hundred and twenty panoramic radiographs were excluded to minimize the selection bias. In a dim lit room, an observer assessed the radiographs on a standard radiographic light box. The position of the impacted maxillary canine was recorded in line with the longitudinal axis of a tooth using the edge of a metal ruler. Data were subsequently put on SPSS 11.5 software and chi-square (${\chi}^2$) tests were applied to find out the association. Results : Among 580 panoramic radiographs it was found that impacted maxillary canines were present in only 7 (1.2%) radiographs. A statistical significant difference was found between the age of the patients and the vertical position of the impacted canines (p=0.000) and between the age of the patients and the horizontal position of the impacted canines (p=0.003). Conclusion : The prevalence was found to be low compared with the present study from the limitation of panoramic image. Further study needs to include three-dimensional imaging modality.
치과 방사선검사에 있어 두부 내의 흡수선량에 관한 평가를 하고자 인체모형팬텀 내부의 뇌하수체와 안구, 상악동, 악하선, 갑상선, 식도에 유리형광소자를 삽입하고 X-선을 조사하였다. 사용된 장치로는 Kodak 2200, Kodak 8000C dental radiographic systems과 computed tomography(Lightspeed VCT)이고 촬영조건은 임상에서 사용하는 인자와 동일하게 설정하였다. 이때 구내 X-선 검사의 경우 흡수선량은 0.02~2.47cGy로 가장 높게 측정된 곳은 상악 대구치 촬영 시 2.47cGy인 갑상선이었고 가장 낮은 곳은 하악 전치부 촬영에서 0.02cGy인 악하선이었다. 그리고 구외 X-선 검사의 경우 흡수선량은 세파로에서 0.36~3.44cGy, 파노라마에서 0.14~12.82cGy, 전산화단층촬영에서 8.17~253.63cGy 가장 높게 측정된 곳은 상악 CT 촬영 시 253.63cGy인 악하선이었고 가장 낮은 곳은 파노라마 촬영에서 0.14cGy인 안구이었다. 구외 X-선 검사가 구내 X-선 검사 보다 많은 흡수선량이 측정되었다. 특히 CT를 이용한 검사에서는 구내 촬영보다 100배 이상 높게 측정되었다. 따라서 구외 X-선 검사에 있어서 가이드라인을 제시하여야 하며 방사선에 의한 흡수선량을 줄이기 위한 노력이 요구된다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.