• 제목/요약/키워드: Radiography, Dental

검색결과 509건 처리시간 0.021초

Extraoral periapical radiography: an alternative approach to intraoral periapical radiography

  • Kumar, Rahul;Khambete, Neha;Priya, Ekta
    • Imaging Science in Dentistry
    • /
    • 제41권4호
    • /
    • pp.161-165
    • /
    • 2011
  • It is difficult to take intraoral radiographs in some patients who are intolerable to place the film in their mouth. For these patients, Newman and Friedman recommended a new technique of extraoral film placement. Here we report various cases that diagnostic imaging was performed in patients using the extraoral periapical technique. This technique was used to obtain the radiographs for the patients with severe gag reflex, pediatric dental patients, and patients with restricted mouth opening. This technique can be recommended as an alternative to conventional intraoral periapical technique in cases where intraoral film placement is difficult to achieve.

상악동 병변의 인지시 파노라마 방사선사진의 유용성 (Usefulness of Panoramic Radiography in the Detection of Maxillary Sinus Pathosis)

  • 이은숙;박창서
    • 치과방사선
    • /
    • 제29권1호
    • /
    • pp.223-239
    • /
    • 1999
  • Purpose: to evaluate the usefulness of the panoramic radiography, generally used in dental clinic, for the detection of the maxillary sinus pathosis due to the inflammation and tumor, through the comparison with CT findings as the absolute standard. Materials & Methods: 150 maxillary sinuses of 75 patients with or without particular signs and symptoms and showing soft tissue lesions or destruction of maxillary sinus walls in at least one sinus in CT, were selected as subject samples, and the panoramic radiography of the same patients were interpretated by 3 dental radiologists and 3 non dental radiologist given no previous informations. Using the CT findings as the absolute standard, the diagnostic ability of panoraimc radiography in the mucosal thickening, maxillary sinus haziness, inferior wall destruction, medial wall destruction, posterolateral wall destruction and the superior wall destruction was evaluated using the ROC curve and the difference between dental radiologist group and non dental radiologist group was also evaluated. Results: 1. When dental radiologist group interpretated the destruction of inferior wall and posterolateral wall, the kappa value which shows interobserver's coincidence was above 0.75. 2. The diagnostic ability according to site of interpretation was the highest when the inferior wall was interpretated in both observer groups and there was a statistically significant difference between the dental radiologist group and non dental radiologist group in interpretating the mucosal thickening, haziness, destruction of the inferior and medial wall(p<0.05). 3. The diagnostic ability in detecting the destruction of the sinus walls was better than in soft tissue lesions in both groups and between the groups there was a statistically significant difference(p<0.05). Conclusion: When detecting the destruction of inferior and posterolateral wall of the maxillary sinus there was coincident with that of CT findings, and so it is considered that diagnostic ability of panoramic radiography is high in this point. But in interpretating the destruction of medial wall and soft tissue lesions, diagnostic ability of the panoramic radiography was relatively low and there was a significant difference between the dental radiologist group and non dental radiologist group. Therefore CT or other auxiliary diagnostic method will be necessary when evaluating thorough pathosis of maxillary sinus objectively.

  • PDF

일부 치위생 학생들의 엑스선촬영에 있어서의 감염관리 실태 조사 (A study on Performance of Infection Control in X-ray Taking for Dental Hygiene Student)

  • 이영애;조민정
    • 치위생과학회지
    • /
    • 제5권4호
    • /
    • pp.221-225
    • /
    • 2005
  • 구강진료기관에서의 개인방호의 중요성을 일깨우기 위해 보건대학 치위생과 3학년 재학생을 대상으로 치면세마와 엑스선 촬영 실습 수행과정에서 감염관리 및 엑스선안전관리에 대한 실천 정도를 조사하여 아래와 같은 결과를 얻었다. 1. 치면세마 실습시에는 감염관리에 대해 높은 수준으로 인식하고 철저히 수행하고 있었다. 2. 엑스선촬영 실습시에 감염관리의 필요성에 대한 인식 정도는 비교적 낮았다. 3. 엑스선촬영 실습시에는 필름유지기구를 제외하고는 거의 감염관리를 하지 않고 있었다. 4. 엑스선촬영 실습시에 엑스선안전관리에 대해서는 높은 수준으로 인식하고 실천하고 있었다. 이상의 결과를 종합해 볼 때 엑스선촬영시에는 거의 감염관리가 이루어지지 않고 있다는 것을 알 수 있다. 완벽한 감염관리를 위해 엑스선촬영시에도 철저한 감염관리가 이루어질 수 있도록 필요성에 대한 인식제고와 실천율을 높일 수 있는 교육의 강화가 요구된다.

  • PDF

디지털 방사선영상 시스템의 기본적 원리 (Physical principles of digital radiographic imaging system)

  • 최진우;이원진
    • Imaging Science in Dentistry
    • /
    • 제40권4호
    • /
    • pp.155-158
    • /
    • 2010
  • Digital radiographic systems allow the implementation of a fully digital picture archiving and communication system (PACS), and provide the greater dynamic range of digital detectors with possible reduction of X-ray exposure to the patient. This article reviewed the basic physical principles of digital radiographic imaging system in dental clinics generally. Digital radiography can be divided into computed radiography (CR) and direct radiography (DR). CR systems acquire digital images using phosphor storage plates (PSP) with a separate image readout process. On the other hand, DR systems convert X-rays into electrical charges by means of a direct readout process. DR systems can be further divided into direct and indirect conversion systems depending on the type of X-ray conversion. While a direct conversion requires a photoconductor that converts X-ray photons into electrical charges directly, in an indirect conversion, lightsensitive sensors such as CCD or a flat-panel detector convert visible light, proportional to the incident X-ray energy by a scintillator, into electrical charges. Indirect conversion sensors using CCD or CMOS without lens-coupling are used in intraoral radiography. CR system using PSP is mainly used in extraoral radiographic system and a linear array CCD or CR sensors, in panoramic system. Currently, the digital radiographic system is an important subject in the dental field. Most studies reported that no significant difference in diagnostic performance was found between the digital and conventional systems. To accept advances in technology and utilize benefits provided by the systems, the continuous feedback between doctors and manufacturers is essential.

지식기반 다중 템플릿을 이용한 치과용 디지털 X-ray 영상에서의 미세변화 검출에 관한 연구 (Bone Loss Detection in Dental Radiography by Domain Knowledge Based Multi-template)

  • 안용학;채옥삼
    • 대한전자공학회논문지SP
    • /
    • 제47권3호
    • /
    • pp.70-80
    • /
    • 2010
  • 본 논문에서는 치과용 의료시스템(Dental PACS)에서 필요한 시계열 분석(Subtraction Radiography) 방법에 기반 하여 기존의 연구에서 갖지 못했던 영상정렬의 자동화 방안과 미세변화 검출 방안을 제안한다. 제안된 방법은 기존의 단일 템플릿 방식의 문제점을 해결하기 위해 인공치아 및 자연치아의 기하학적 형태 정보를 이용하여 각 치아에 대한 관심영역을 획득하고 획득된 관심영역을 기준으로 지식 기반(knowlege-based)의 다중 템플릿(multi-template) 방식의 정합을 통해 치아 주위에서 발생되는 미세변화를 빠르고 정확하게 검출할 수 있다. 실험결과 제안된 방법은 신속하고 정확하게 치아 주위의 미세변화에 대한 검출이 가능하였고, 보다 객관적이고 정량적인 결과를 제시할 수 있음을 보여주었다.

소아환자에서 교정분석을 위한 콘빔CT 촬영시 유효선량에 관한 연구 (Effective dose of cone-beam computed tomography for orthodontic analysis in pediatric patient)

  • 김은경
    • 대한치과의사협회지
    • /
    • 제53권8호
    • /
    • pp.558-568
    • /
    • 2015
  • Objective: The objectives of this study were to measure pediatric organ and effective doses of cone-beam computed tomography (CBCT) for orthodontic analysis and to compare them to those of panoramic and lateral cephalometric radiography, the conventional radiography for orthodontic analysis. Materials and Methods: Alphard VEGA for CBCT, Planmeca Proline XC for panoramic radiography and Orthophos CD for cephalometric radiography were used for this study. Thermoluminescent dosimeter (TLD) chips were located at 24 anatomic sites of 10-year-old anthropomorphic phantom and exposed during CBCT (C-mode; $200{\times}179mm$ FOV), panoramic and lateral cephalometric radiographic procedures at the clinical exposure settings for 10-year-old patient. Pediatric organ and effective doses were measured and calculated using ICRP 2007 tissue weighting factors. Results: Effective doses of CBCT, panoramic radiography and lateral cephlometric radiography in pediatric clinical exposure settings were $292.5{\mu}Sv$, $19.3{\mu}Sv$, and $4.4{\mu}Sv$ respectively. The thyroid gland contributed most significantly to the effective dose in all the radiographic procedures. Conclusion: Effective dose of CBCT was about 12 times to conventional radiographic procedures for orthodontic analysis in pediatric patient. The use of CBCT for orthodontic analysis should be fully justified over conventional radiography and dose optimization to decrease thyroid dose is needed in pediatric patients.

A comparative study of cone-beam computed tomography and digital periapical radiography in detecting mandibular molars root perforations

  • Haghanifar, Sina;Moudi, Ehsan;Mesgarani, Abbas;Bijani, Ali;Abbaszadeh, Naghi
    • Imaging Science in Dentistry
    • /
    • 제44권2호
    • /
    • pp.115-119
    • /
    • 2014
  • Purpose: The aim of this in vitro study was to determine the sensitivity and specificity of cone-beam computed tomography (CBCT) and digital periapical radiography in the detection of mesial root perforations of mandibular molars. Materials and Methods: In this in vitro study, 48 mandibular molars were divided into 4 groups. First, the mesial canals of all the 48 teeth were endodontically prepared. In 2 groups (24 teeth each), the roots were axially perforated in the mesiolingual canal 1-3 mm below the furcation region, penetrating the root surface ("root perforation"). Then, in one of these 2 groups, the mesial canals were filled with gutta-percha and AH26 sealer. Mesial canals in one of the other 2 groups without perforation (control groups) were filled with the same materials. The CBCT and periapical radiographs with 3 different angulations were evaluated by 2 oral and maxillofacial radiologists. The specificity and sensitivity of the two methods were calculated, and P<0.05 was considered significant. Results: The sensitivity and specificity of CBCT scans in the detection of obturated root canal perforations were 79% and 96%, respectively, and in the case of three-angled periapical radiographs, they were 92% and 100%, respectively. In non-obturated root canals, the sensitivity and specificity of CBCT scans in perforation detection were 92% and 100%, respectively, and for three-angled periapical radiographs, they were 50% and 96%, respectively. Conclusion: For perforation detection in filled-root canals, periapical radiography with three different horizontal angulations would be trustworthy, but it is recommended that CBCT be used for perforation detection before obturating root canals.

상악동의 점막비후에 대한 WATERS방사선사진과 파노라마방사선사진 및 전산화단층사진의 진단능 비교 (Comparison of Waters′ radiography, panoramic radiography, and computed tomography in the diagnosis of antral mucosal thickening)

  • 현영민;이삼선;최순철
    • 치과방사선
    • /
    • 제28권1호
    • /
    • pp.261-269
    • /
    • 1998
  • With the CT findings as gold standard, the sensitivity, the specificity, and the diagnostic accuracy of Waters' radiography and Waters' radiography with panoramic radiography were compared in the diagnosis of antral mucosal thickening of 16 patients. Three oral radiologists and three non-oral radiologists interpreted the Waters' radiographs and after 4 weeks, interpreted the Waters' radiographs and panoramic radiographs simultaneously. The interpretation point was the existence or the non-existence of the mucosal thickening on the medial, the posterolateral, the floor, and the roof of maxillary sinus. The obtained results were as followed : 1. In oral radiologist group, the sensitivity, specificity and diagnostic accuracy of Waters' film were 0.7250, 0.8489 and 0.7578 respectively. 2. The sensitivity and the diagnostic accuracy in oral radiologist group were higher than those of non-oral radiologist group (P<0.05), but there was no significant difference between two groups in the specificity (P>0.05), 3. There was no significant difference of the diagnostic abilities except the specificity in oral radiologist group between Waters' radiography and Waters' radiography with panoramic radiography (P>0.05). 4. The sensitivity and the diagnostic accuracy were the highest in the case of medial wall interpretation, the specificity was the highest in the posterolateral wall. 5. In the posterolateral wall and the floor, the sensitivity and the diagnostic accuracy of oral radiologist group were higher than those of non-oral radiologist group (P<0.05).

  • PDF

치과방사선 검사에서 두부(brain)의 흡수선량 평가 (Evaluation the absorbed dose in brain of dental radiography)

  • 전운선;한동균
    • 한국방사선학회논문지
    • /
    • 제5권6호
    • /
    • pp.343-349
    • /
    • 2011
  • 치과 방사선검사에 있어 두부 내의 흡수선량에 관한 평가를 하고자 인체모형팬텀 내부의 뇌하수체와 안구, 상악동, 악하선, 갑상선, 식도에 유리형광소자를 삽입하고 X-선을 조사하였다. 사용된 장치로는 Kodak 2200, Kodak 8000C dental radiographic systems과 computed tomography(Lightspeed VCT)이고 촬영조건은 임상에서 사용하는 인자와 동일하게 설정하였다. 이때 구내 X-선 검사의 경우 흡수선량은 0.02~2.47cGy로 가장 높게 측정된 곳은 상악 대구치 촬영 시 2.47cGy인 갑상선이었고 가장 낮은 곳은 하악 전치부 촬영에서 0.02cGy인 악하선이었다. 그리고 구외 X-선 검사의 경우 흡수선량은 세파로에서 0.36~3.44cGy, 파노라마에서 0.14~12.82cGy, 전산화단층촬영에서 8.17~253.63cGy 가장 높게 측정된 곳은 상악 CT 촬영 시 253.63cGy인 악하선이었고 가장 낮은 곳은 파노라마 촬영에서 0.14cGy인 안구이었다. 구외 X-선 검사가 구내 X-선 검사 보다 많은 흡수선량이 측정되었다. 특히 CT를 이용한 검사에서는 구내 촬영보다 100배 이상 높게 측정되었다. 따라서 구외 X-선 검사에 있어서 가이드라인을 제시하여야 하며 방사선에 의한 흡수선량을 줄이기 위한 노력이 요구된다.

Effect of changing the kilovoltage peak on radiographic caries assessment in digital and conventional radiography

  • Zayet, Mohamed Khalifa;Helaly, Yara Rabee;Eiid, Salma Belal
    • Imaging Science in Dentistry
    • /
    • 제44권3호
    • /
    • pp.199-205
    • /
    • 2014
  • Purpose: This study aimed to investigate the effect of changing the kilovoltage peak (kVp) on the radiographic assessment of dental caries. Materials and Methods: Seventy-five extracted posterior teeth with proximal caries or apparently sound proximal surfaces were radiographed with conventional E-speed films and a photostimulable phosphor system using 60 kVp and 70 kVp for the caries assessment. The images were evaluated by three oral radiologists and compared with the results of the stereomicroscope analysis. Results: No statistically significant difference was found between 60 kVp and 70 kVp for the caries detection, determination of caries extension into dentin, and caries severity in either the conventional or the digital images. Good to very good inter-observer and intra-observer agreements were found for both kilovoltage values on the conventional and digital images. Conclusion: Changing the kilovoltage between 60 kVp and 70 kVp had no obvious effect on the detection of proximal caries or determination of its extension or severity.