• 제목/요약/키워드: Radiography, Dental, Digital

검색결과 125건 처리시간 0.02초

Correlation of morphological variants of the soft palate and Need's ratio in normal individuals: A digital cephalometric study

  • Verma, Pradhuman;Verma, Kanika Gupta;Kumaraswam, Kikkeri Lakshminarayana;Basavaraju, Suman;Sachdeva, Suresh K.;Juneja, Suruchi
    • Imaging Science in Dentistry
    • /
    • 제44권3호
    • /
    • pp.193-198
    • /
    • 2014
  • Purpose: The present study was aimed to investigate the variation of soft palate morphology in different age and gender groups. The correlations of radiographic velar length (VL), velar width (VW), pharyngeal depth (PD), and Need's ratio with soft palate variants were also studied in the North Indian subpopulation. Materials and Methods: The study sample consisted of 300 subjects aged between 15 and 45 (mean: 31.32) years. The velar morphology on lateral cephalograms was examined and grouped into six types. The results obtained were subjected to a statistical analysis to find the correlation between variants of the soft palate with gender and different age groups. Results: The most frequent type of soft palate was leaf shaped (48.7%), and the least common was crook shaped (3.0%) among both the genders and various age groups, showing a significant correlation. The mean VL, VW, and PD values were significantly higher in males and significantly correlated with the types of soft palate. A significant correlation was observed between the mean VL, VW, PD, and Need's ratio with various age groups, showing an inconsistent pattern with an increase in age. The types of soft palate, gender, and Need's ratio were also significantly correlated, with an overall higher mean value of the Need's ratio among female subjects and the S-shaped soft palate. Conclusion: The knowledge of a varied spectrum of velar morphology and the variants of the soft palate help in a better understanding of the velopharyngeal closure and craniofacial anomalies.

Is the panoramic mandibular index useful for bone quality evaluation?

  • Kwon, Ah-Young;Huh, Kyung-Hoe;Yi, Won-Jin;Lee, Sam-Sun;Choi, Soon-Chul;Heo, Min-Suk
    • Imaging Science in Dentistry
    • /
    • 제47권2호
    • /
    • pp.87-92
    • /
    • 2017
  • Purpose: The aim of this study was to determine whether the panoramic mandibular index (PMI) is useful for assessing bone mineral density. We also analyzed the potential correlations between PMI parameters and patient age. Materials and Methods: Four observers measured the PMI of both sides of the mental foramen using a picture archiving and communication system and images in the Digital Imaging and Communications in Medicine format. They studied 300 panoramic radiographic images of patients belonging to the following age groups: 40-49 years, 50-59 years, 60-69 years, 70-79 years, and 80-89 years. The observers were allowed to zoom in or out and to adjust the contrast of the images. Further, they were instructed to record the reasons for any measurements that could not be made. Then, we conducted a reliability analysis of the measured PMI and assessed the correlations between different patient age groups and the 3 parameters used for determining the PMI from the available data. Results: Among the 600 data items collected, 23 items were considered unmeasurable by at least 1 observer for the following 4 reasons: postoperative state, lesion, unidentified mental foramen, and alveolar bone loss. The intraobserver reproducibility of the measurable data was 0.611-0.752. The mandibular cortical width (MCW) decreased significantly as patient age increased. Conclusion: PMI had limited usability when the margin of the mental foramen was not clear. In contrast, MCW, a parameter used for determining the PMI, had fewer drawbacks than the PMI with respect to bone mineral density measurements and exhibited a significant correlation with patient age.

Enhanced visualization of the root canal morphology using a chitosan-based endo-radiopaque solution

  • Shashirekha Govind;Amit Jena;Satabdi Pattanaik;Mahaprasad Anarasi ;Satyajit Mohapatra;Vinay Shivagange
    • Restorative Dentistry and Endodontics
    • /
    • 제46권3호
    • /
    • pp.33.1-33.12
    • /
    • 2021
  • Objectives: This study aimed to investigate the efficacy of ionic and non-ionic-based contrast media (in vitro study) and the combinatorial effect of chitosan-based endo-radiopaque solution (CERS) (in vivo study) for visualization of the root canal anatomy. Materials and Methods: In vitro study (120 teeth): The root canal of maxillary premolars and molars (in vitro group 1 and 2 respectively, n = 60 each) were analyzed using 4 different contrast media (subgroups: Omnipaque 350, Iopamidol, Xenetix 350, and Urografin 76; n = 15 each) in combination with 5.25% sodium hypochlorite (NaOCl). Based on the results of the in vitro study, in vivo study (80 teeth) was done to compare Xenetix 350 + 5.25% NaOCl with CERS (in vivo group 1 and 2 respectively, n = 40 each) on maxillary and mandibular premolars and molars. Two endodontists used radiovisiography to assess the depth of ingress and identify the aberrant root anatomy after access cavity preparation, and after initial cleaning and shaping of canals. Kruskal-Wallis test was used for in vitro comparison (p < 0.05), and Wilcoxon signed-rank test and Mann-Whitney U test for in vivo analysis (p < 0.01). Results: In vitro study, Xenetix 350 + 5.25% NaOCl facilitated a significant higher visualization (p < 0.05). For in vivo study, CERS had a statistically significant depth of ingress (p < 0.01), and was efficient in identifying the aberrant root canal anatomy of premolars and molars. Conclusions: CERS facilitates better visualization of the root canal anatomy of human premolars and molars.

방사선사진에서의 골질과 임상적으로 평가한 골질 분류의 상관관계 (Correlation of bone quality in radiographic images with clinical bone quality classification)

  • 김현우;허경회;박관수;김정화;이원진;허민석;이삼선;최순철
    • Imaging Science in Dentistry
    • /
    • 제36권1호
    • /
    • pp.25-32
    • /
    • 2006
  • Purpose : To investigate the validity of digital image processing on panoramic radiographs in estimating bone quality before endosseous dental implant installation by correlating bone quality in radiographic images with clinical bone quality classification. Materials and Methods : An experienced surgeon assessed and classified bone quality for implant sites with tactile sensation at the time of implant placement. Including fractal dimension eighteen morphologic features of trabecular pattern were examined In each anatomical sites on panoramic radiographs. Finally bone quality of 67 implant sites were evaluated in 42 patients. Results : Pearson correlation analysis showed that three morphologic parameters had weak linear negative correlation with clinical bone quality classification showing correlation coefficients of -0.276, -0.280, and - 0.289, respectively (p<0.05). And other three morphologic parameters had obvious linear negative correlation with clinical bone quality classification showing correlation coefficients of -0.346, -0.488, and -0.343 respectively (p<0.05). Fractal dimension also had a linear correlation with clinical bone quality classification with correlation coefficients -0.506 significantly (p<0.05). Conclusion : This study suggests that fractal and morphometric analysis using digital panoramic radiographs can be used to evaluate bone quality for implant recipient sites.

  • PDF

Repeat analysis of intraoral digital imaging performed by undergraduate students using a complementary metal oxide semiconductor sensor: An institutional case study

  • Yusof, Mohd Yusmiaidil Putera Mohd;Rahman, Nur Liyana Abdul;Asri, Amiza Aqiela Ahmad;Othman, Noor Ilyani;Mokhtar, Ilham Wan
    • Imaging Science in Dentistry
    • /
    • 제47권4호
    • /
    • pp.233-239
    • /
    • 2017
  • Purpose: This study was performed to quantify the repeat rate of imaging acquisitions based on different clinical examinations, and to assess the prevalence of error types in intraoral bitewing and periapical imaging using a digital complementary metal-oxide-semiconductor(CMOS) intraoral sensor. Materials and Methods: A total of 8,030 intraoral images were retrospectively collected from 3 groups of undergraduate clinical dental students. The type of examination, stage of the procedure, and reasons for repetition were analysed and recorded. The repeat rate was calculated as the total number of repeated images divided by the total number of examinations. The weighted Cohen's kappa for inter- and intra-observer agreement was used after calibration and prior to image analysis. Results: The overall repeat rate on intraoral periapical images was 34.4%. A total of 1,978 repeated periapical images were from endodontic assessment, which included working length estimation (WLE), trial gutta-percha (tGP), obturation, and removal of gutta-percha (rGP). In the endodontic imaging, the highest repeat rate was from WLE (51.9%) followed by tGP (48.5%), obturation (42.2%), and rGP (35.6%). In bitewing images, the repeat rate was 15.1% and poor angulation was identified as the most common cause of error. A substantial level of intra- and inter-observer agreement was achieved. Conclusion: The repeat rates in this study were relatively high, especially for certain clinical procedures, warranting training in optimization techniques and radiation protection. Repeat analysis should be performed from time to time to enhance quality assurance and hence deliver high-quality health services to patients

치근단 방사선 사진에서 Paewinsky 연령추정법 적용에 대한 연구 (The Application of Paewinsky et al.'s Age Estimation Method to Periapical Radiographs)

  • 노병윤;서정욱;김창겸;최창운;이원준;이상섭
    • The Korean Journal of Legal Medicine
    • /
    • 제42권4호
    • /
    • pp.141-145
    • /
    • 2018
  • There have been many radiographic studies on age estimation that evaluate reduction in size of dental pulp cavity with secondary dentin formation. The Paewinsky method reported high accuracy in estimating ages by measuring the width of the pulp cavity in panoramic radiographs. The aim of this study was to evaluate the application of the Paewinsky method to digital periapical radiographs. This study was conducted on 103 cases that reported to the Section of Human Identification of the National Forensic Service. The age was calculated by applying the Paewinsky method that measures the root and pulp canal width at three points in a tooth. The estimation results were compared with those calculated by the Johanson method. When the Paewinsky models were applied to digital periapical radiographs, the errors were significantly greater as compared to the original study. The errors of the maxillary second premolar and mandibular lateral incisor were greater than those of the maxillary central incisor, lateral incisor, mandibular canine, and first premolar. Furthermore, errors of the age estimation models in level C were greater than those in levels A and B. This study could be a reference for the application of the Paewinsky method to digital periapical radiographs.

The effects of image acquisition control of digital X-ray system on radiodensity quantification

  • Seong, Wook-Jin;Kim, Hyeon-Cheol;Jeong, Soocheol;Heo, Youngcheul;Song, Woo-Bin;Ahmad, Mansur
    • Restorative Dentistry and Endodontics
    • /
    • 제38권3호
    • /
    • pp.146-153
    • /
    • 2013
  • Objectives: Aluminum step wedge (ASW) equivalent radiodensity (eRD) has been used to quantify restorative material's radiodensity. The aim of this study was to evaluate the effects of image acquisition control (IAC) of a digital X-ray system on the radiodensity quantification under different exposure time settings. Materials and Methods: Three 1-mm thick restorative material samples with various opacities were prepared. Samples were radiographed alongside an ASW using one of three digital radiographic modes (linear mapping (L), nonlinear mapping (N), and nonlinear mapping and automatic exposure control activated (E)) under 3 exposure time settings (underexposure, normal-exposure, and overexposure). The ASW eRD of restorative materials, attenuation coefficients and contrasts of ASW, and the correlation coefficient of linear relationship between logarithms of gray-scale value and thicknesses of ASW were compared under 9 conditions. Results: The ASW eRD measurements of restorative materials by three digital radiographic modes were statistically different (p = 0.049) but clinically similar. The relationship between logarithms of background corrected grey scale value and thickness of ASW was highly linear but attenuation coefficients and contrasts varied significantly among 3 radiographic modes. Varying exposure times did not affect ASW eRD significantly. Conclusions: Even though different digital radiographic modes induced large variation on attenuation of coefficient and contrast of ASW, E mode improved diagnostic quality of the image significantly under the underexposure condition by improving contrasts, while maintaining ASW eRDs of restorative materials similar. Under the condition of this study, underexposure time may be acceptable clinically with digital X-ray system using automatic gain control that reduces radiation exposure for patient.

Prevalence and characteristics of pneumatized articular tubercle: First large series in Iranian people

  • Shokri, Abbas;Noruzi-Gangachin, Maruf;Baharvand, Maryam;Mortazavi, Hamed
    • Imaging Science in Dentistry
    • /
    • 제43권4호
    • /
    • pp.283-287
    • /
    • 2013
  • Purpose: This study was performed to determine the prevalence and characteristics of pneumatized articular tubercle or eminence among a defined group of Iranian people. Materials and Methods: Digital panoramic radiographs of 1694 patients in the Department of Oral and Maxillofacial Radiology, Hamadan Dental School, Iran were evaluated retrospectively to detect the above lesion. Finally, 1563 radiographs were selected according to inclusion criteria. Then, a review was done of 10 large case series found using a MEDLINE search of the literature. Chi-squared test was used to analyze the differences in variables such as age, gender, laterality, and locularity in our case series. Results: The average age of our samples was $32.6{\pm}7.63$ years. Pneumatized articular tubercle was found in 98 cases, representing a prevalence of 6.2% with a mean age of $22.8{\pm}7.9$ and a range of 8 to 60 years. Sixty-four (65.3%) pneumatized articular tubercles were unilateral, with 30 lesions on the right and 34 on the left side. Bilateral lesions were found in 34 (34.7%) patients. 52 (53.06%) of the pneumatized articular tubercles were of the unilocular type and 46 (46.94%) were multilocular. The results showed no statistically significant differences regarding age (p=0.454), gender (p=0.634), laterality (p=0.252), or locularity (p=0.807) among the samples. Conclusion: Among ten large case series from other countries, the prevalence of pneumatized articular tubercle (6.2%) in Iranian patients was higher than that of all eight of the case series that used the same detection method as the present study of panoramic radiography.

Diagnostic accuracy of artificially induced vertical root fractures: a comparison of direct digital periapical images with conventional periapical images

  • Lee Ji-Un;Kwon Ki-Jeong;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • 제34권4호
    • /
    • pp.185-190
    • /
    • 2004
  • Purpose: To compare the diagnostic accuracy for the detection of root fractures in CMOS-based digital periapical images with conventional film-based periapical images. Materials and Methods: Sixty extracted single-root human teeth with closed apices were prepared endodontically and divided into two groups; artificially induced vertical root fracture group and control group. All radiographs were obtained using the paralleling technique. The radiographs were examined by 4 observers three times within a 4 week interval. Receiver operating characteristic (ROC) analysis was carried out using data obtained from four observers. Intra- and inter-examiner agreements were computed using kappa analysis. Results: The area under the ROC curve (Az) was used as an indicator of the diagnostic accuracy of the imaging system. Az values were as follows: direct-digital images; 0.93, film-based images; 0.92, and inverted digital images; 0.91. There was no significant difference between imaging modalities (P<0.05). The kappa value of inter-observer agreement was 0.42 (range: 0.28-0.60) and intra-observer agreement was 0.57 (range: 0.44-0.75). Conclusion : There is no statistical difference in diagnostic accuracy for the detection of vertical root fractures between digital periapical images and conventional periapical images. The results indicate that the CMOS sensor is a good image detector for the evaluation of vertical root fractures.

  • PDF

Assessment of infection control in oral radiology during the COVID-19 outbreak: An international collaborative study

  • Rafaela C Santos;Larissa S Araujo;Rafael B Junqueira;Eliana D Costa;Fernanda M Pigatti;Kivanc Kamburoglu;Pedro HB Carvalho;Manuela LB Oliveira;Sibele N Aquino;Francielle S Verner
    • Imaging Science in Dentistry
    • /
    • 제53권4호
    • /
    • pp.365-373
    • /
    • 2023
  • Purpose: In the context of COVID-19, studies evaluating the adherence of dentists and dental students to infection control are relevant due to their high occupational exposure and risk, as well as their responsibility for disseminating information and good practices. This study evaluated the adherence of dentists and dental students to infection control in the oral radiology field in the setting of the COVID-19 pandemic on different continents. Materials and Methods: This cross-sectional observational study involved individuals who performed intraoral radiographic examinations during the COVID-19 pandemic. The Questionnaire on Infection Control in Oral Radiology was administered virtually using a Google Form. Participants from different continents(the Americas, Africa, Europe, Asia, and Oceania) were recruited. Data were subjected to descriptive analysis and simple and multiple binary regression (5%). Results: There were 582 valid answers, and 68.73% of the participants were from the Americas, 18.90% from Europe, and 12.37% from Asia. The median score for infection control protocols was 94 points for dental students and 104 points for dentists, and participants below the median were considered to have low adherence to infection control in oral radiology. Low access to infection control was found for 53.0% of dentists in the Americas, 34.0% from Europe, and 26.9% from Asia. Conclusion: The adherence to infection control protocols in oral radiology was low even in the face of the COVID-19 pandemic. The results may help improve the awareness of students and professionals, since oral radiology routines have the potential for transmitting COVID-19.