  • Purpose: To compare the radiographic evaluations between two radiographic views (AP and lateral views) and four radiographic views (AP, lateral and both oblique views) in ankle fractures. Materials and Methods: From January 2000 to June 2002, 60 cases of ankle fractures were treated with open reduction and internal fixation and its followed up periods were at least 2 years. All cases were classified into three groups according to the method of preoperative radiographic evaluation. Two radiographic views (AP and lateral views) were taken in group A and four radiographic views (AP, lateral and both oblique views) were taken in group B. 12 Cases were evaluated with three dimensional computed tomography (3D CT). Four radiographic views and 3D CT were taken in group C. All cases were classified according to the Danis-Weber and Lauge-Hansen classification. Displacement of fracture fragment of medial, lateral, posterior malleolus and size of fracture fragment of posterior malleous were measured using picture archiving communication system (PACS). Results: Although kappa value between two or four radiographic views were good or excellent in Danis-Weber classification and Lauge-Hansen classification of ankle fractures, the displacements of medial and lateral malleoli were statistically different. Four radiographic views evalulated the degree of displacement of medial and lateral fragments more accurately compared to two radiographic views. Conclusion: Four radiographic views will be more useful than two radiographic views to decide the method of treatment and operation considering the displacement of fracture fragment.

  • PDF

EXPERIMENTAL STUDY OF INFLUENCE ON RADIOGRAPHIC DENSITY AND CONTRAST BY THE CHANGE OF KILOVOLTAGE AND EXPOSURE TIME (관전압과 X선노출시간의 변화가 X선사진의 흑화도와 대조도에 미치는 영향에 관한 실험적 연구)

  • Lee Byeong Do;Lee Sang Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.1
    • /
    • pp.113-124
    • /
    • 1990
  • For the study of the influence of kilovoltage and exposure time on radiographic density and contrast, we measured radiographic density of aluminum step wedge which composed of contiguous 8 steps wedges of 2-16㎜ thickness with densitometer. Aluminum step wedge was radiographed on Kodak ultraspeed DF-58 and Ektaspeed EP-21 film with range of 60-90 kVp and 5-60 impulse and subject contrast of aluminum step wedge with constant radiographic density and image contrast percentage without radiographic density was evaluated. Then we evaluated the film quality of teeth and their surrounding structure according to the change of kVp and exposure time by score rating method. The obtained results were as follows: 1. Radiographic density was related to the change of kilovoltage, especially in increased exposure time. 2. With constant radiographic density, subject contrast of thin aluminum step wedges was greater in low kilovolt age than high kilovoltage, but kilovolt age had not great influence on subject contrast of thick aluminum step wedge. On the other hand, radiographic density difference between 2mm and 16mm aluminum step wedge was decreased according to in- creasing kilovoltage. 3. Without constant radiographic density, image contrast percentage was decreased with increasing kilovoltage, but was not related with the change of exposure time. 4. Radiographic contrast of teeth and their surrounding structure which was taken with the range of 60-90 kVp and 6-30 impulse had not great influence on film quality.

  • PDF

Suspectible Object Detection Method for Radiographic Images (방사선 검색기 영상 내의 의심 물체 탐지 방법)

  • Kim, Gi-Tae;Kang, Hyun-Soo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.3
    • /
    • pp.670-678
    • /
    • 2014
  • This paper presents a method to extract objects in radiographic images where all the allowable combinations of segmented regions are compared to a target object using Fourier descriptor. In the object extraction for usual images, a main problem is occlusion. In radiographic images, there is an advantage that the shape of an object is not occluded by other objects. It is because radiographic images represent the amount of radiation penetrated through objects. Considering the property of no occlusion in radiographic images, the shape based descriptors can be very effective to find objects. After all, the proposed object extraction method consists of three steps of segmenting regions, finding all the combinations of the segmented regions, and matching the combinations to the shape of the target object. In finding the combinations, we reduce a lot of computations to remove unnecessary combinations before matching. In matching, we employ Fourier descriptor so that the proposed method is rotation and shift invariant. Additionally, shape normalization is adopted to be scale invariant. By experiments, we verify that the proposed method works well in extracting objects.

Reliability and Validity of the Manual Measurement Method for Patellar Height (무릎뼈 높이에 대한 도수측정방법의 신뢰도와 타당도)

  • Kim, Moon-Hwan;Yun, Sung-Joon;Weon, Jong-Hyuck
    • Physical Therapy Korea
    • /
    • v.20 no.3
    • /
    • pp.54-61
    • /
    • 2013
  • This study was to determine the reliability and validity of manual measurements of patellar height to standard radiographic measurements in 30 knees of 15 subjects. Patellar height was measured using manual and radiographic methods. The manual measurements were performed by two examiners using digital vernier calipers with the subject sitting and the knees in $30^{\circ}$ of flexion. The radiographic measurements were performed in the same position. The reliability of the manual measurements was assessed by means of intraclass correlation coefficients [ICC(3,1)], and the validity was investigated using the Pearson's product-moment correlation coefficient and an independent t-test. The intra- and inter-rater reliabilities of the manual measurement of patellar height were excellent (ICC=.86 and .88 respectively). The validity of patellar height measured manually compared to the radiographic method was good (Pearson's r=.69). In conclusion, the manual method is an objective, qualitative measurement of patella height.

Diagnostic Radiography of Premature Closure of Distal Growth Plate of Ulna in a Dog (개에서 척골의 원위 성장판 조기 폐쇄증에 대한 방사선학적 평가)

  • 송경진;이희천;이기창;권정국;최민철
    • Journal of Veterinary Clinics
    • /
    • v.20 no.3
    • /
    • pp.403-405
    • /
    • 2003
  • A 11 month-old Shihtzu was referred to the Veterinary Medical Teaching Hospital, Seoul National University. Clinical signs of this patient were lameness, shortening limb, angular deformity, rotation of foot, subluxaion of elbow joint and restricted range of movement of left forelimb. For the evaluation of the abnormalities of left forelimb, radiographic examination was carried out. Radiographic findings were characteristics of premature closure of distal ulna such as closure of distal ulna growth plate and cranial bowing of radius. With radiographic signs and physical examination, it was diagnosed as premature closure of growth plate of the left forelimb. After osteotomy of the radius and ostectomy of the ulna, radiographic evaluation of limb about angulation of elbow joint was performed every 2-3 weeks for 3 months. In case of premature closure of distal growth plate of ulna, radiography was very useful for diagnositic method of premature closure of distal ulna and monitoring of healing process.

CORRELATION ASSESSMENT BETWEEN RESONANCE FREQUENCY ANALYSIS AND RADIOGRAPHIC METHOD ACCORDING TO PERI-IMPLANT BONE CHANGE

  • Lee Mi-Ran;Cho Lee-Ra;Yi Yang-Jin;Choi Hang-Moon;Park Chan-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.6
    • /
    • pp.736-744
    • /
    • 2005
  • Statement of problem. Initial stability of implant is an important factor for predicting osseointegration. It requires a rapid, non-invasive, user-friendly technique to frequently assess the implant stability and the degree of osseointegration. Purpose. The aim of this study was to evaluate the correlation between the resonance frequency analysis (RFA) and the radiographic method for peri-implant bone change under in vitro conditions. Material and Method. Twenty implants of 3.75 mm in diameter(Neoplant, Neobiotech, Korea) were used. To simulate peri-implant bone change, 2 mm-deep $45^{\circ}$ range horizontal defect and 2 mm-deep $90^{\circ}$ range horizontal defect area were serially prepared perpendicular to the X-ray beam after conventional implant insertion. Customized film holding device was fabricated to standardize the projection geometry for serial radiographs of implants and direct digital image was obtained. ISQ values and gray values inside threads were measured before and after peri-implant bone defect preparation. Results. Within a limitation of this study, ISQ value of resonance frequency analysis was changed according to peri-implant bone change (p<0.05) and gray value of radiographic method was changed according to peri-implant bone change (p<0.05). There was no correlation between the ISQ value and the gray value for peri-implant bone change (p>0.05). But, in horizontal defect condition, relatively positive correlation were between ISQ and gray values(r=0.663). Conclusion. This results provided a possibility that peri-implant bone change may be evaluated by both RFA and radiographic method.

In vivo assessment of accuracy of Propex II, Root ZX II, and radiographic measurements for location of the major foramen

  • Tampelini, Fernanda Garcia;Coelho, Marcelo Santos;de Azevedo Rios, Marcos;Fontana, Carlos Eduardo;Rocha, Daniel Guimaraes Pedro;Pinheiro, Sergio Luiz;da Silveira Bueno, Carlos Eduardo
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.3
    • /
    • pp.200-205
    • /
    • 2017
  • Objectives: The aim of this in vivo study was to assess the accuracy of 2 third-generation electronic apex locators (EALs), Propex II (Dentsply Maillefer) and Root ZX II (J. Morita), and radiographic technique for locating the major foramen (MF). Materials and Methods: Thirty-two premolars with single canals that required extraction were included. Following anesthesia, access, and initial canal preparation with size 10 and 15 K-flex files and SX and S1 rotary ProTaper files, the canals were irrigated with 2.5% sodium hypochlorite. The length of the root canal was verified 3 times for each tooth using the 2 apex locators and once using the radiographic technique. Teeth were extracted and the actual WL was determined using size 15 K-files under a ${\times}25$ magnification. The Biostat 4.0 program (AnalystSoft Inc.) was used for comparing the direct measurements with those obtained using radiographic technique and the apex locators. Pearson's correlation analysis and analysis of variance (ANOVA) were used for statistical analyses. Results: The measurements obtained using the visual method exhibited the strongest correlation with Root ZX II (r = 0.94), followed by Propex II (r = 0.90) and Ingle's technique (r = 0.81; p < 0.001). Descriptive statistics using ANOVA (Tukey's post hoc test) revealed significant differences between the radiographic measurements and both EALs measurements (p < 0.05). Conclusions: Both EALs presented similar accuracy that was higher than that of the radiographic measurements obtained with Ingle's technique. Our results suggest that the use of these EALs for MF location is more accurate than the use of radiographic measurements.

Radiopacity of restorative composites by conventional radiograph and digital images with different resolutions

  • Dantas, Raquel Venancio Fernandes;Sarmento, Hugo Ramalho;Duarte, Rosangela Marques;Meireles Monte Raso, Sonia Saeger;de Andrade, Ana Karina Maciel;Dos Anjos-Pontual, Maria Luiza
    • Imaging Science in Dentistry
    • /
    • v.43 no.3
    • /
    • pp.145-151
    • /
    • 2013
  • Purpose: This study was performed to evaluate and compare the radiopacity of dentin, enamel, and 8 restorative composites on conventional radiograph and digital images with different resolutions. Materials and Methods: Specimens were fabricated from 8 materials and human molars were longitudinally sectioned 1.0 mm thick to include both enamel and dentin. The specimens and tooth sections were imaged by conventional radiograph using #4 sized intraoral film and digital images were taken in high speed and high resolution modes using a phosphor storage plate. Densitometric evaluation of the enamel, dentin, restorative materials, a lead sheet, and an aluminum step wedge was performed on the radiographic images. For the evaluation, the Al equivalent (mm) for each material was calculated. The data were analyzed using one-way ANOVA and Tukey's test (p<0.05), considering the material factor and then the radiographic method factor, individually. Results: The high speed mode allowed the highest radiopacity, while the high resolution mode generated the lowest values. Furthermore, the high resolution mode was the most efficient method for radiographic differentiation between restorative composites and dentin. The conventional radiograph was the most effective in enabling differentiation between enamel and composites. The high speed mode was the least effective in enabling radiographic differentiation between the dental tissues and restorative composites. Conclusion: The high speed mode of digital imaging was not effective for differentiation between enamel and composites. This made it less effective than the high resolution mode and conventional radiographs. All of the composites evaluated showed radiopacity values that fit the ISO 4049 recommendations.

CLINICO-STATISTICAL STUDY ON THE RADIOGRAPHIC FINDINGS BY THE CLINICAL FINDINGS OF 115 AMELOBLASTOMAS (임상소견에 따른 법랑모세포종의 방사선학적 특징에 관한 임상통계학적 분석)

  • Park, No-Boo;Shin, Shang-Wook;Kim, Chin-Soo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.17 no.4
    • /
    • pp.415-428
    • /
    • 1995
  • The author studied on the 115 cases of the ameloblastoma which had been diagnosed with biopsy during the period of 1962 to 1994 at the Kyungpook National University Hospital, Pusan National University Hospital, Youngnam University Hospital, Keimyung University Hospital, Catholic Medical School Hospital, and Maryknol Hospital. This study contains the statistical analysis of the clinico-pathological findings such as sex, age, location, chief complaint, duration,treatment method, size, recurrence and impacted teeth in relation to radiographic findings. The results were as follows : 1. The incidence rate was 60% in male and 40% in female. 2. At the time of diagnosis, the age of the patients ranged from 9 to 69 years old (average 31.4 years old). The cases of 73% were in the 2nd, 3rd and 4th decades of life. 3. The majority of cases, 88.7% occurred in the mandible, especially 59% in the mandibular angle area. 4. The most prevalent chief complaint of swelling was 56.5%. 5. As regards duration, the cases less than 12 months appeared 49.5%, and average duration is 30.45months. 6. Unilocular radiographic findings showed 43.5%, Multilocular radiographic findings appeared 56.5%. 7. Conservative treatment was performed 40.0%, and radical treatment was employed 60.0%. 8. There was the variation of lesional sizes between 2.0cm and 15cm, average size 6.19cm. 9. Recurrent cases were 28.7%, and impacted teeth were shown 30.43%. 10. The radiographic finding has no relationship with the factors of age, location, chief complaint, recurrence and impacted teeth, however there is slight indication that the below 30-year-old patient tend to be related to the multilocular type. 11. The multilocular radiographic findings were shown more frequently in the groups of females, over average of 30.45 months, over average size of 6.19cm and radical treatment.

  • PDF

VALIDITY OF CLINICAL, TRANSCRANIAL RADIOGRAPHIC AND MAGNETIC RESONANCE IMAGING METHOD IN THE DIAGNOSIS OF INTERNAL DERANGEMENT OF TEMPOROMANDIBULAR JOINT (악관절장애 환자의 임상 및 측사위경두개 촬영에 의한 진단과 자기공명영상에 의한 진단의 비교연구)

  • Choi Jeong Hee;Chung Hyun Dae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.21 no.2
    • /
    • pp.327-336
    • /
    • 1991
  • The purpose of this study was to evaluate the validity among the clinical, transcraial radiographic and MRI diagnosis in internal derangement of the temporomandibular joint. Fourty two temporomandibular joints were assessed in twenty one patients who visited the dental department of Chonnam National University Hospital with the complaint of temporomandibular disorder from Oct. 1990 to Oct. 1991. The results were as follows: 1. In the clinically symptomatic 29 TMJs, 26 (89.7%) joints reveal disc displacement and 3 (10.3%) joints reveal normal disc position on MRI. The sensitivity of clinical diagnosis was 0.77, and the specificity was 0.63. 2. In the normal 22 TMJs on the trans cranial radiographic finding, 16 (72.7%) joints reveal disc displacement, and 6 (27.3%) joints reveal normal disc position on MRI. In the abnormal 20 TMJs on the transcranial radiographic finding, 18 (90%) joints reveal disc displacement, and 2 (10%) joints reveal normal disc position on MRI. The sensitivity of trans cranial radio- graph was 0.53, and the specificity was 0.75.

  • PDF