Effects of locally-delivered minocycline hcl on controlled periodontal disease (Minocycline 국소 약물 방출 제제의 치주질환 치료 효과)

  • Chung, Mi-Hyun;Kwon, Young-Hyuk;Herr, Yeek;Lee, Man-Sup;Park, Joon-Bong
    • Journal of Periodontal and Implant Science
    • /
    • 제28권1호
    • /
    • pp.37-56
    • /
    • 1998
  • The purpose of this study was to evaluate the clinical and microbiological outcomes following the use of 30% minocycline-loaded polycaprolacton film and 2% minocycline-loaded gel that was applied locally into pockets combined with scaling and root planing. 25 human subjects who were non-pregnant, non-lactating, aged 20-50 and diagnosed as moderate to advanced adult periodontitis were enrolled. Subjects were excluded if they had a history of severe acute or chronic systemic disease, if they required antibiotic prophylaxis for dental treatment for any reason, or if they reported a history suggestive of hypersensitivity reactions to minocycline or tetracycline. 4quadrants that had several teeth with a 5-8mm probing pocket depth and radiographic evidence of alveolar bone loss for each patient were selected and divided into test sites and control sites according to the split-mouth design. Scaling and root planing was done for each site at baseline(0week). Test sites received the minocycline gel and strip and control sites had saline irrigation. The patients received both treatments simyltaneously. Subgingival irrigation of sterile saline was applied to the control sites for approximately 30 seconds. Minocycline strip and gel was applied into the periodontal pocket at 1, 2, 3, 4 weeks each after scaling and root planing in the test sites. The clinical and microbiological measurements were made at baseline and at the follow-up visits 6, 10, 14, 20 weeks. The results of this study were as follows; 1. The sulcular bleeding index, probing pocket depth and Periocheck test was significantly reduced and the relative proportions of spirochetes and motile rods were significantly reduced and the proportion of cocci was correspondingly increased, in locally delivered minocycline strip group compared to saline irrigation group. 2. In locally delivered minocycline gel group, The effect was the same with minocycline strip group as compared with saline irrigation therapy. 3. There was no significant differences between minocycline strip group and minocycline gelgroup. In conclusion, minocycline HCl local drug delivery combined with scaling and root planing may provide added improvement of clinical and microbiological responses by inhibiting bacterial recolonization of treated sites. It is suggested that the local administration of minocycline-HCl in the periodontal pocket is effective when combined with subgingival mechanical debridement.

  • PDF

An Optimal Structure of a Novel Flat Panel Detector to Reduce Scatter Radiation for Clinical Usage: Performance Evaluation with Various Angle of Incident X-ray (산란선 제거를 위한 신개념 간접 평판형 검출기의 임상적용을 위한 최적 구조 : 입사 X선 각도에 따른 성능평가)

  • Yoon, Yongsu
    • Journal of radiological science and technology
    • /
    • 제40권4호
    • /
    • pp.533-542
    • /
    • 2017
  • In diagnostic radiology, the imaging system has been changed from film/screen to digital system. However, the method for removing scatter radiation such as anti-scatter grid has not kept pace with this change. Therefore, authors have devised the indirect flat panel detector (FPD) system with net-like lead in substrate layer which can remove the scattered radiation. In clinical context, there are many radiographic examinations with angulated incident X-ray. However, our proposed FPD has net-like lead foil so the vertical lead foil to the angulate incident X-ray would have bad effect on its performance. In this study, we identified the effect of vertical/horizontal lead foil component on the novel system's performance and improved the structure of novel system for clinical usage with angulated incident X-ray. Grid exposure factor and image contrast were calculated to investigate various structure of novel system using Monte Carlo simulation software when the incident X-ray was tilted ($0^{\circ}$, $15^{\circ}$, and $30^{\circ}$ from the detector plane). More photons were needed to obtain same image quality in the novel system with vertical lead foil only then the system with horizontal lead foil only. An optimal structure of novel system having different heights of its vertical and horizontal lead foil component showed improved performance compared with the novel system in a previous study. Therefore, the novel system will be useful in a clinical context with the angulated incident X-ray if the height and direction of lead foil in the substrate layer are optimized as the condition of conventional radiography.

Preliminary Experience with Cervical Implantable Titanium Cage(RABEA) in Patients with Monosegmental Degenerative Disease : Clinical and Radiological Outcomes without Cancellous Bone Filling into Cage (단일 분절 퇴행성 경추질환에서 Titanium Cage를 이용한 전방 융합술의 조기 치험 : 골편 이식을 동반하지 않은 경우의 임상적 방사선학적 초기 결과)

  • Lee, Young-Kyun;Han, Young-Min;Kim, Jong-Tae;Chung, Dong-Sup;Park, Young-Sup;Park, Chun-Kun;Kang, Joon-Ki
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권sup2호
    • /
    • pp.300-308
    • /
    • 2001
  • Objectives : Anterior cervical discectomy and interbody fusion has become a well-accepted surgical treatment of degenerative cervical diseases. Implatable cages have a stabilizing effect without plates and no need for autogenous bone graft. The authors evaluates the effect of implatable titanium cage(RABEA) on the clinical and radiological outcomes. Methods : 34 patients with symptomatic cervical degenerative diseases due to one level disc pathology were underwent anterior cervical discectomy and interbody fusion with titanium cages(RABEA) which were not filled with cancallous bone grafts from January 1999 to May 2001. Patients with osteoporosis and older than 65 years were not included. Among them, 15 patients could be followed-up for at least 1 year. The authors retrospectively reviewed the charts and radiographic data. Mean follow-up period was $1.3{\pm}0.2years$. Results : Clinical results according to the Odom's criteria was exellent and good in 14(93%) patients. One patient with fair result showed complete loss of the disc space height due to settlement of the cage. Preoperatively, the mean height of the disc space(${\pm}$standard deviation) was $3.42{\pm}1.10mm$(range 2.0-5.5mm), and at 1 day postoperatively it was $7.88{\pm}0.90mm$(range 6.50-9.0). The mean height of the disc space after 1 year was $6.50{\pm}1.38mm$(range 3.0-8.0). The restoration of the height was statistically significant(p<0.05). The mean height after 1 year was $82.7{\pm}15.9%$ of the height at 1 day postoperatively. Preoperatively the mean value of the cervical lodortic angle was $21.8{\pm}11.8^{\circ}$ and 1 year postopertively, it was $24.5{\pm}8.3^{\circ}$, which was statistically not significant. All patients showed no abnormal movements on flexion and extension lateral film after 6 months. Conclusion : Implantable titanium cages appear safe and effective in selected patients, and their use helps to avoid complications associated with bone graft harvest. Subsidence of the cage seems to be a potential risk factor for recurrence of the symptoms. For long-term results, a longer follow-up is required.

  • PDF

Combined Hysterosalpingography and Laparoscopy in Infertility (복강경하(腹腔鏡下)에서의 Hysterosalpingogram)

  • Ku, Pyong-Sahm
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제7권1_2호
    • /
    • pp.11-20
    • /
    • 1980
  • Hysterosalpingograms (H.S.G.) have been done for several decades to determine causative factors in female infertility. However, the H.S.G. only reverals uterine cavity and tubal patency or inpatency. The author prefers to find more details in regard to the status and condition of the female reproductive organs and their surrounding tissue as they pertain to infertility. H.S.G. in combination with laparoscopic examination reveals the following results. Preparation and method of performance of H.S.G. during laparoscopy in a healthy reproductive age women are as follows. When laparoscopy is not contraindicated, NPO is ordered with routine bowel preparation. Analgesics administered by injection prior to procedure are valium 10mgs and pethidine 50-100mgs. The radiographic procedure is the same as for any HSG technique. During laparoscopy a solution of 3 to 10 ccs. of 60% hypaque sodium is used. Fluroscopic scout films are obtained A-P and oblique views as well as a delayed check film. 1. Age distribution of primary and secondary infertility in this studies involving tubal factors was as follows: 20-29 age group showed 46% incidence and in the 30-39 age group, 50% incidence. Duration of infertility in this study group was the following: 1-2 years showed 26.7%, 3-5 years 53.8%, and 6-9 years 13.3%. 2. Indications of laparoscopic examination were as follows: Secondary infertility in 35% of the cases, obscure tubal occlusion on previous H.S.G. in 25%, unknown origin in 11.7%, and the remaining cases included pelvic pain, small masses, dysmenorrhea, and uterine anomaly. The laparoscopic examination showed clearly the reproductive organs and the surrounding tissues in the pelvic cavity. The abnormal tubal findings there revealed were tuberculous salpingitis and hydrosalpinx in 10% each, endometriosis and peritubabl adhesions in 6.7% each, biconuate uterus in 3.3%. The remaining 58.3% of the cases showed normal findings. Laparoscopic observation for possible myoma nodules, streak ovary, and peritubal adhesions was also done at this time. 3. Comparative tubal findings in combined H.S.G. and laparoscopic examination revealed the following. Bilateral tubal occlusion was present in 14% (7cases) on laparoscopic examination but on H.S.G. 38% (19 cases) were noted. However, tubal occlusion and peritubal adhesions were found in 26% (13 cases) upon laparoscopy and only 8% (4 cases) on H.S.G. examination alone. Normal pelvic findings were present in 60% (27 cases).

  • PDF

The Analysis of a Cerrobend Compensator and a Electronic Compensator Designed by a Radiation Treatment Planning System (방사선치료계획장치로 설계된 Cerrobend 선량보상체와 전자 선량보상체의 제작 및 특성 분석)

  • Nah Byung-Sik;Chung Woong-Ki;Ahn Sung-Ja;Nam Taek-keun;Yoon Mi-Sun;Song Ju-Young
    • Progress in Medical Physics
    • /
    • 제16권2호
    • /
    • pp.82-88
    • /
    • 2005
  • In this study, the physical compensator made with the high density material, Cerrobend, and the electronic compensator realized by the movement of a dynamic multileaf collimator were analyzed in order to verify the properness of a design function in the commercial RTP (radiation treatment planning) system, Eclipse. The CT images of a phantom composed of the regions of five different thickness were acquired and the proper compensator which can make homogeneous dose distribution at the reference depth was designed in the RTP. The frame for the casting of Cerrobend compensator was made with a computerized automatic styrofoam cutting device and the Millennium MLC-120 was used for the electronic compensator. All the dose values and isodose distributions were measured with a radiographic EDR2 film. The deviation of a dose distribution was $\pm0.99 cGy\;and\;\pm1.82cGy$ in each case of a Cerrobend compensator and a electronic compensator compared with a $\pm13.93 cGy$ deviation in an open beam condition. Which showed the proper function of the designed compensators in the view point of a homogeneous dose distribution. When the absolute dose value was analyzed, the Cerrobend compensator showed a $+3.83\%$ error and the electronic compensator showed a $-4.37\%$ error in comparison with a dose value which was calculated in the RTP. These errors can be admtted as an reasonable results that approve the accuracy of the compensator design in the RTP considering the error in the process of the manufacturing of the Cerrobend compensator and the limitation of a film in the absolute dosimetry.

  • PDF

Development of $14"{\times}8.5"$ active matrix flat-panel digital x-ray detector system and Imaging performance (평판 디지털 X-ray 검출기의 개발과 성능 평가에 관한 연구)

  • Park, Ji-Koon;Choi, Jang-Yong;Kang, Sang-Sik;Lee, Dong-Gil;Seok, Dae-Woo;Nam, Sang Hee
    • Journal of radiological science and technology
    • /
    • 제26권4호
    • /
    • pp.39-46
    • /
    • 2003
  • Digital radiographic systems based on solid-state detectors, commonly referred to as flat-panel detectors, are gaining popularity in clinical practice. Large area, flat panel solid state detectors are being investigated for digital radiography. The purpose of this work was to evaluate the active matrix flat panel digital x-ray detectors in terms of their modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). In this paper, development and evaluation of a selenium-based flat-panel digital x-ray detector are described. The prototype detector has a pixel pitch of $139\;{\mu}m$ and a total active imaging area of $14{\times}8.5\;inch^2$, giving a total 3.9 million pixels. This detector include a x-ray imaging layer of amorphous selenium as a photoconductor which is evaporated in vacuum state on a TFT flat panel, to make signals in proportion to incident x-ray. The film thickness was about $500\;{\mu}m$. To evaluate the imaging performance of the digital radiography(DR) system developed in our group, sensitivity, linearity, the modulation transfer function(MTF), noise power spectrum (NPS) and detective quantum efficiency(DQE) of detector was measured. The measured sensitivity was $4.16{\times}10^6\;ehp/pixel{\cdot}mR$ at the bias field of $10\;V/{\mu}m$ : The beam condition was 41.9\;KeV. Measured MTF at 2.5\;lp/mm was 52%, and the DQE at 1.5\;lp/mm was 75%. And the excellent linearity was showed where the coefficient of determination ($r^2$) is 0.9693.

  • PDF

Biodistribution of Iodine-131-Iodomisonidazole and Imaging of Tumor Hypoxia in Mice bearing CT-26 Adenocarcinoma (CT-26 선암을 접종한 마우스에서 Iodine-131-Iodomisonidazole의 생체분포 및 종양저산소증의 영상화)

  • Kim, Hye-Won;Kim, Chang-Guhn;Yoon, Kwon-Ha;Kim, Hyun-Jeong;Juhng Seon-Kwan;Roh, Byung-Suk;Yang, David J.;Kim, E.Edmund;Lee, Hyun-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • 제33권3호
    • /
    • pp.289-297
    • /
    • 1999
  • Purpose: Misonidazole is a radiosensitizer that binds in hypoxic cells. The purpose of this study was to find out the feasibility of I-131-Iodomisonidazole (IMISO) for imaging of tumor hypoxia. Materials and Methods: Tosyl precursor was dissolved in acetonitrile and I-131-NaI was added to synthesize IMISO. Balb/c mice inoculated with CT-26 adenocarcinoma were injected with IMISO. Mice were sacrificed at 1, 2, 4, 24 hr and % of injected dose per gram of tissue (%ID/g) was determined. For scintigraphy and MRI, mouse bearing CT-26 adenocarcinoma was administered with IMISO and imaging was performed 4 hr after. Then, mouse body was fixed and microtomized slice was placed on radiographic film for autoradiography Results: %ID/g of tumor was 1.64 (1h), 0.98 (2h), 0.85 (4h) and 0.20 (24h), respectively. At 24h, %ID/g of tumor was higher than that of all other tissues except thyroid. Tumor to muscle ratio increased with time and tumor to blood ratio also increased with time and reached 1.53 at 24 hr. On autoradiogram, tumor was well visualized as an increased activity in central hypoxic area of the tumor which corresponds to the area of high signal intensity on T2-weighted MR image. On scintigraphy, tumor uptake was visualized. Conclusion: This results suggest that IMISO may have a potential for tumor hypoxia imaging in mouse model. However, further study is needed to improve it's localization in tumor tissue and to achieve acceptable images of tumor hypoxia.

  • PDF

A COMPARATIVE STUDY ON RADIOPACITY OF CANAL FILLING AND RETROGRADE ROOT-END FILLING MATERIALS (근관 충전재 및 치근단 역충전재의 방사선 불투과성에 관한 비교 연구)

  • Kim, Yong-Sang;Kim, Seo-Kyong;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • 제33권2호
    • /
    • pp.107-114
    • /
    • 2008
  • This study was performed to assess the radiopacity of a variety of canal filling and retrograde root-end filling materials according to the specification concerning root canal obturation materials. Ten materials including Gutta-percha pellets, amalgam, Fuji II LC, $Dyract^{(R)}$ AP, Super $EBA^{(R)}$, $IRM^{(R)}$, AH $26^{(R)}$, $Sealapex^{TM}$, Tubli-$Seal^{TM}$, and dentin were evaluated in this study. In the first part, densitometric reading of an each step of aluminum step wedge on occlusal film were performed at 60 kVp (0.2, 0.3, 0.4 s), 70 kVp (0.2, 0.3, 0.33 s) to decide appropriate voltage and exposure time. In the second part, ten specimens which are 5 mm in diameter and 0.5, 1.0, 1.5, 2.0, 2.5, 3.0 mm in thickness, were fabricated from each material studied. The specimens were radiographed simultaneously with an aluminum step wedge under decided condition (60 kVp, 0.2 s). The mean radiographic density values of the materials were transformed into radiopacity expressed equivalent thickness of aluminum (mm Al). The following results were obtained. 1. Among the various conditions including 0.2 s, 0.3 s, 0.4 s at 60 kVp and 0.2 s, 0.3 s, 0.33 s at 70 kVp, the appropriate voltage and exposure time that meet the requirement of density from 0.5 to 2.0 was 0.2 s at 60 kVp. 2. All of the materials in this study had greater radiopacity than the minimun level recommended by ISO No. 4049 standards. 3. Most of the materials had greater radiopacity than 3 mm Al requirement of ANSI/ADA specification No. 57 (2000) and ISO No. 6876 (2001) standards except for Fuji II LC and Dyract. It suggests that all experimental canal filling and retrograde root-end filling materials have a sufficient radiopacity that meet the requirement concerning root canal obturation materials except for Fuji II LC and Dyract.

DEVELOPMENT OF THREE DIMENSIONAL MEASURING PROGRAM WITH FRONTAL AND LATERAL CEPHALOMETRIC RADIOGRAPHS -PART 1. COMPUTATION OF THE THREE-DIMENSIONAL COORDINATES BY COMPENSATION OF THE ERROR OF THE HEAD POSITION IN ORDINARY NON-BIPLANAR CEPHALOSTAT- (정모 및 측모 두부 방사선 규격사진을 이용한 3차원 계측 프로그램의 개발 -1. 단일 방사선원으로 촬영된 두부 방사선사진의 두부 위치 보정을 이용한 3차원 좌표의 산출-)

  • Lee, Geun-Ho;Lee, Sang-Han;Jang, Hyon-Joong;Kwon, Tae-Geon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제27권3호
    • /
    • pp.214-220
    • /
    • 2001
  • The clinical application of the three-dimensional radiographic technique had been limited to standard Broadbent-Bolton cephalometer with biplanar stereoradiography. We developed a new method for compensating the error of head position in ordinary non-biplanar cephalostat. It became to possible to use the three dimensional cephalogram commonly in clinical bases. 1. The method of methemetical compensation of head positioning error in non-biplanar condition was evaluated with dry skull. The error of the method of first and the second trial was $0.46{\pm}1.21$, $0.33{\pm}0.90mm$, which means the error of the head positioning correction in conventional cephalogram was within clinical acceptance. 2. The reproducibility of this system for clinical application was 0.54 mm ($-2.99{\sim}2.26mm$) which defines the absolute mean difference of the first and second trial. Compare to the The landmark identification error $1.2{\pm}1.6mm$, the error of the measurement was within the range of landmark identification error. The result indicates the adequate clinical accuracy of the computation of three-dimensional coordinates by compensation of the error of the head position in ordinary non-biplanar cephalostat.

  • PDF

A Study on the Utilization of Diagnostic Equipments and Patient Dose for Diagnostic Radiological Procedures in Korea (진단방사선영역에서 방사선장치의 이용실태 및 환자피폭선량에 관한 조사연구)

  • Kim Youhyun;Choi Jonghak;Kim Sungsoo;Lee Chanhyeup;Cho Pyongkon;Lee Youngbae;Kim Chelmin
    • Progress in Medical Physics
    • /
    • 제16권1호
    • /
    • pp.10-15
    • /
    • 2005
  • IAEA's guidance levels have been provided for western people to the end. Guidance levels lower than the IAEA'S will be necessary in view of Korean people's proportions. Therefore, we need to develope the standard doses for Korean people. And we conducted a nationwide survey of patient dose from x-ray examinations in Korea. In this study, the 278 institutions were selected from Members Book of Korean Hospital Association. The valid response rate was approximately 57.9%. Doses were calculated from the questionnaires by NDD method. We obtained the results were as follows; 1) General radiographic equipments were distributed for 42.0%, fluoroscopic equipments 29.4%, dental equipments 13.2%, CT units 8.1 % and mamographic units 7.2%. 2) According to classification by rectification, three-phase equipments were 29.9%, inverter-type generators 29.5%, single-phase equipments 25.5%, constant voltage units 9.0% and unknown units 6.0%. 3) According to classification by receptor system, film-screen types were 46.8%, CR types 26.8%, DR types 17.7% and unknown types 8.9%. 4) The number of examinations were chest 49.2%, spine 16.8% and abdomen 12.7%. 5) Patient doses were head AP 3.44 mGy, abdomen AP 4.25 mGy and chest PA 0.39 mGy.

  • PDF