• Title/Summary/Keyword: Radiographic Images

Search Result 341, Processing Time 0.022 seconds

THE STUDY OF EVALUATION TO RELATIONSHIP BETWEEN THE INFERIOR ALVEOLAR NERVE AND THE MANDIBULAR THIRD MOLAR BY USING RADIOGRAPHIC IMAGE (방사선 사진을 이용한 하악 제3대구치와 하치조신경의 관계에 대한 연구)

  • Kim, Jong-Hyoup;Gu, Hong;An, Jin-Suk;Kook, Min-Suk;Park, Hong-Ju;Oh, Hee-Kyun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.5
    • /
    • pp.464-473
    • /
    • 2006
  • Purpose: This study was performed to evaluate relationship between the inferior alveolar nerve injury and the findings of panoramic and tomographic images for preventing inferior alveolar nerve injury after the 3rd molar extraction. Material and Method: From April, 2005 to June, 2005, The 190 patients who visited in the Department of Oral and Maxillofacia Surgery, Chonnam National University Hospital and the panoramic radiographies were taken for extraction of the mandibular third molar, was selected. Among 215 mandibular third molars, Scanora tomographic imagings were taken in the 90 teeth which were overlaped to the mandibular canal in the panoramic imagies. In panoramic radiographies, the angulation, the level, the root morphology, and the superimposition sign of the mandibular third molars with the mandibular canal were evaluated. In the tomographic radiographies, the location and distance of the mandibular third molar from the canal were also evaluated. The relationships between these findings and the inferior alveolar nerve injury were examined. Results: In the panoramic findings, the inferior alveolar nerve injuries were occurred in the darkened roots (5 molars, 7%), the uncontinuous radiopaque image (3 molars, 7%), and the depositioned mandibular canal (2 molars, 10%). In the tomographic findings of 90 molars, 20 molars also had the superimposition imagies. Five molars in those molars (25%) had the inferior alveolar nerve injury after extraction. There were 10 patients who had the inferior alveolar nerve injury. The sensory was began to be recovered in 9 patients, except 1 patient, within 2 weeks, then fully recovered within 3 months. Conclusion: These results indicate that the depth mandibular third molar and the superimposition sign may be related with the risk of the inferior alveolar nerve injury after extraction.

A Study Radiograph Techniques for Diagnosis of Axillary Fracture Ribs in X-ray (X-ray 갈비뼈 촬영에서 겨드랑이쪽의 골절된 갈비뼈 진단을 위한 촬영법 연구)

  • Ahn, Byung-Ju;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.979-986
    • /
    • 2019
  • The purpose of this study devised a method for the examination of the images of the first and second rib fractures of the axillary using Rib Rando Phantom. The position of the phantom and the angle of the X-ray tube were changed to vertical, head 5° and foot 5°. The Radiological Technologists subjectively evaluated the acquired images and the evaluation data were analyzed by SPSS 3.0 ver. The signal to noise ratio(SNR) was calculated using the ImageJ Program. As a result, the cronbach alpha value was significantly higher at 0.789. The SNR was highest at 6.038 when the X-ray tube was tilted 5° toward the head in the front of the ribs and highest at 7.860 when the X-ray tube was tilted 5° toward the foot. Radiographic Techniques proposed axillary ribs this study are as follows. The anterior rib scan is examined by elevating the fractured area and changing the X-ray tube angle by 5° towards the head. The posterior ribs scan is examined by attaching the fractured area and changing to the X-ray tube angle by 5° towards the foot. It is considered that such an inspection method can obtain a sharp image.

A study of the panoramic radiographic images of the buccolingual dilaceration (협설만곡치아의 파노라마방사선영상소견에 대한 연구)

  • Kim, Young-Ho;Jeong, Hwan-Seok;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.40 no.1
    • /
    • pp.39-44
    • /
    • 2010
  • Purpose : We want to identify the appearance of the buccolingual root dilaceration teeth in the panoramic views and specify the characteristics of these teeth. Materials and Methods : One thousand-six patients were examined on the basis of both panoramic and CT image criteria. We diagnosed and excluded certain teeth from the samples; both prosthodontic or pathologic lesion appearing teeth and mesiodistally dilacerated ones. We meticulously discerned buccolingually dilacerated teeth in the CT images and total 48 samples were selected. The degree of severity in dilaceration was standardized by 2 types of criteria. The samples were differentiated into 3 groups and again categorized into six types showing from the panoramic views: irregular view on the root apex area, clear blunt on the root tip, stepping on root tip, double lamina dura or double tip, arrow-target shaped root, bull's eye, normal view. Results : The types of teeth selected from total 48 buccolingual root dilaceration samples were mandibular first and second molar, premolars, canines, and lateral incisors. The direction of dilaceration was an even percentage to each buccal and lingual side for most selected teeth, however, that of both canines and lateral incisors were directed in almost a buccal side. In the panoramic views, the root types of the buccolingually dilacerated teeth were irregular view on the root apex area, clear blunt on the root tip, stepping on root tip and normal types were almost always normal view. The more severity in dilareated degree, the more chances of observation in the panoramic views were clear blunt on the root tip and stepping on root tip. Conclusion : As observed in the shape of stepping on root tip or double lamina dura in the panoramic views, there can be much more probability to diagnose as a buccolingually dilacerated root.

Reduction of Radiographic Quantum Noise Using Adaptive Weighted Median Filter (적응성 가중메디안 필터를 이용한 방사선 투과영상의 양자 잡음 제거)

  • Lee, Hoo-Min;Nam, Moon-Hyon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.5
    • /
    • pp.465-473
    • /
    • 2002
  • Images are easily corrupted by noise during the data transmission, data capture and data processing. A technical method of noise analyzing and adaptive filtering for reducing of quantum noise in radiography is presented. By adjusting the characteristics of the filter according to local statistics around each pixel of the image as moving windowing, it is possible to suppress noise sufficiently while preserve edge and other significant information required in reading. We have proposed adaptive weighted median(AWM) filters based on local statistics. We show two ways of realizing the AWM filters. One is a simple type of AWM filter, whose weights are given by a simple non-linear function of three local characteristics. The other is the AWM filter which is constructed by homogeneous factor(HF). Homogeneous factor(HF) from the quantum noise models that enables the filter to recognize the local structures of the image is introduced, and an algorithm for determining the HF fitted to the detection systems with various inner statistical properties is proposed. We show by the experimented that the performances of proposed method is superior to these of other filters and models in preserving small details and suppressing the noise at homogeneous region. The proposed algorithms were implemented by visual C++ language on a IBM-PC Pentium 550 for testing purposes, the effects and results of the noise filtering were proposed by comparing with images of the other existing filtering methods.

New method of assessing the relationship between buccal bone thickness and gingival thickness

  • Kim, Yun-Jeong;Park, Ji-Man;Kim, Sungtae;Koo, Ki-Tae;Seol, Yang-Jo;Lee, Yong-Moo;Rhyu, In-Chul;Ku, Young
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.6
    • /
    • pp.372-381
    • /
    • 2016
  • Purpose: The aim of this study was to determine the relationship between buccal bone thickness and gingival thickness by means of a noninvasive and relatively accurate digital registration method. Methods: In 20 periodontally healthy subjects, cone-beam computed tomographic images and intraoral scanned files were obtained. Measurements of buccal bone thickness and gingival thickness at the central incisors, lateral incisors, and canines were performed at points 0-5 mm from the alveolar crest on the superimposed images. The Friedman test was used to compare buccal bone and gingival thickness for each depth between the 3 tooth types. Spearman's correlation coefficient was calculated to assess the correlation between buccal bone thickness and gingival thickness. Results: Of the central incisors, 77% of all sites had a buccal thickness of 0.5-1.0 mm, and 23% had a thickness of 1.0-1.5 mm. Of the lateral incisors, 71% of sites demonstrated a buccal bone thickness <1.0 mm, as did 63% of the canine sites. For gingival thickness, the proportion of sites <1.0 mm was 88%, 82%, and 91% for the central incisors, lateral incisors, and canines, respectively. Significant differences were observed in gingival thickness at the alveolar crest level (G0) between the central incisors and canines (P=0.032) and between the central incisors and lateral incisors (P=0.013). At 1 mm inferior to the alveolar crest, a difference was found between the central incisors and canines (P=0.025). The lateral incisors and canines showed a significant difference for buccal bone thickness 5 mm under the alveolar crest (P=0.025). Conclusions: The gingiva and buccal bone of the anterior maxillary teeth were found to be relatively thin (<1 mm) overall. A tendency was found for gingival thickness to increase and bone thickness to decrease toward the root apex. Differences were found between teeth at some positions, although the correlation between buccal bone thickness and soft tissue thickness was generally not significant.

Three-Dimensional Evaluation of Impacted Mesiodens Using Dental Cone-Beam Computed Tomography in Korean Children and Adolescents (치과용 cone beam CT를 이용한 한국인 소아 및 청소년의 매복 정중과잉치에 대한 3차원적 분석)

  • Kim, Sang-Duk;Lee, Sang-Ho;Lee, Nan-Young;Jeon, Sang-Yun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.40 no.3
    • /
    • pp.149-158
    • /
    • 2013
  • The purpose of this study was to evaluate the shape and impacted pattern of mesiodens and associated complications using three dimensional images produced by dental CBCT. This study was based on the CBCT (CB Mercury, Hitachi, Tokyo, Japan) radiographic view of 280 pediatric patients who visited the Department of Pediatric Dentistry at the Chosun University Dental Hospital with the chief complain of mesiodens during between 2007 and 2012. Impacted mesiodens occurs more frequently in boys than in girls, the ratio being approximately 3.3:1 and most cases were observed between 6 and 8 years of age. The number of mesiodens per patient was 1.38. Majority of the mesiodens were conical (79.5%) in shape and inverted (48.6%) in direction. The mesio-distal position of mesiodens were the most common in middle sector (81.8%), vertical level were the most common near cervical (60.3%), and labio-palatal position were the most common at palatal side of the dental arch (73.8%). 47.5% of mesiodens had complications and common complications associated with mesiodens were displaced tooth and delayed eruptions. The shape, vertical level, and labio-palatal position of mesiodens had correlations with complications. CBCT appears to be an excellent diagnostic tool, providing three dimensional information and accurate images, for diagnosis of impacted mesiodens.

Analysis of Image Factors of X-ray Films: Study for the Intelligent Replenishment System of Automatic Film Processor (자동현상기 지능화에 필요한 연산처리 기법의 개발을 위한 방사선 필름의 영상 지수의 분석)

  • Park, Sung-Tae;Yoon, Chong-Hyun;Park, Kwang-Bo;Auh, Yong-Ho;Lee, Hyoung-Jin;In, Kyung-Hwan;Kim, Keon-Chung
    • Journal of radiological science and technology
    • /
    • v.21 no.1
    • /
    • pp.35-39
    • /
    • 1998
  • We analyzed image factors to determine the characteristic factors that need for intelligent replenishment system of the auto film processor. We processed the serial 300 sheets of radiographic films of chest phantom without replenishment of developing and fixation replenisher. We took the digital data by using film digitizer which scaned the films and automatically summed up the pixel values of the films. We analyzed characteristic curves, average gradients and relative speeds of individual film using densitometer and step densitometry. We also evaluated the pH of developer, fixer, and washer fluid with digital pH meter. Fixer residual rate and washing effect were measured by densitometer using the reagent methods. There was no significant reduction of the digital density numbers of the serial films without replenishment of developer and fixer. The average gradients were gradually decreased by 0.02 and relative speeds were also gradually decreased by 6.96% relative to initial standard step-densitometric measurement. The pHs of developer and fixer were reflected the inactivation of each fluid. The fixer residual rates and washing effects after processing each 25 sheets of films were in the normal range. We suggest that the digital data are not reliable due to limitation of the hardware and software of the film digitizer. We conclude that average gradient and relative speed which mean the film's contrast and sensitivity respectively are reliable factors for determining the need for the replenishment of the auto film processor. We need more study of simpler equations and programming for more intelligent replenishment system of the auto film processor.

  • PDF

The Fate of Proximal Junctional Vertebral Fractures after Long-Segment Spinal Fixation : Are There Predictable Radiologic Characteristics for Revision surgery?

  • Jang, Hyun Jun;Park, Jeong Yoon;Kuh, Sung Uk;Chin, Dong Kyu;Kim, Keun Su;Cho, Yong Eun;Hahn, Bang Sang;Kim, Kyung Hyun
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.3
    • /
    • pp.437-446
    • /
    • 2021
  • Objective : To investigate the radiographic characteristics of the uppermost instrumented vertebrae (UIV) and UIV+1 compression fractures that are predictive of revision surgery following long-segment spinal fixation. Methods : A total 27 patients who presented newly developed compression fracture at UIV, UIV+1 after long segment spinal fixation (minimum 5 vertebral bodies, lowest instrumented vertebra of L5 or distal) were reviewed retrospectively. Patients were divided into two groups according to following management : revisional surgery (group A, n=13) and conservative care (group B, n=14). Pre- and postoperative images, and images taken shortly before and after the occurrence of fracture were evaluated for radiologic characteristics Results : Despite similar degrees of surgical correction of deformity, the fate of the two groups with proximal junctional compression fractures differed. Immediately after the fracture, the decrement of adjacent disc height in group A (32.3±7.6 mm to 23.7±8.4 mm, Δ=8.5±6.9 mm) was greater than group B (31.0±13.9 mm to 30.1±15.5 mm, Δ=0.9±2.9 mm, p=0.003). Pre-operative magnetic resonance imaging indicated that group A patients have a higher grade of disc degeneration adjacent to fractured vertebrae compared to group B (modified Pfirrmann grade, group A : 6.10±0.99, group B : 4.08±0.90, p=0.004). Binary logistic regression analysis indicated that decrement of disc height was the only associated risk factor for future revision surgery (odds ratio, 1.891; 95% confidence interval, 1.121-3.190; p=0.017). Conclusion : Proximal junctional vertebral compression fractures with greater early-stage decrement of adjacent disc height were associated with increased risk of future neurological deterioration and necessity of revision. The condition of adjacent disc degeneration should be considered regarding severity and revision rate of proximal junctional kyphosis/proximal junction failures.

Dose and Image Evaluation according to Changes in Tube Voltage during Chest X-ray Examination according to Automatic Exposure Control (자동노출제어장치 유·무에 따른 흉부 후·전방향 검사 시 관전압 변화에 따른 선량 및 영상평가)

  • Young-Cheol, Joo;Dong-Hee, Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.871-877
    • /
    • 2022
  • This study was conducted to improve the problems of exposure dose and image reading applied to patients due to the incorrect use of AEC during chest radiography. Images were acquired by dividing the case where AEC was used as the test condition and the case where AEC was not used. As a result of the study, the dose was reduced by 1.17% in 110 kVp without AEC than with AEC, 17.2% decrease at 100 kVp, 30.19% decrease at 90 kVp, and 46.45% decrease at 80 kVp. There was a significant difference in the statistical values according to the tube voltage change in the lung, trachea, and heart SNR average values with AEC and without AEC 110 kVp, but the difference in image quality was insignificant in actual images. When AEC was not applied at the same tube voltage, the dose could be reduced by 17.2% while maintaining the image quality similar to that of with AEC at 100 kVp without AEC. Therefore, rather than relying on AE conditions during chest radiographic examination, it is considered that the conditions should be considered for the examination while lowering the dose by selecting an appropriate tube voltage.

Study on the radiographic evaluation of marginal bone loss around short-length implant after functional loading (기능적 부하 후 "Short Implant" 주변의 골 흡수에 대한 방사선학적 연구)

  • Park, Young-Ju;Nam, Jeong-Hun;Noh, Kyung-Lok;Yeon, Byoung-Moo;Yu, Woo-Geun;Lee, Jeong-Won;Ahn, Jang-Hun;Gang, Tae-In;Park, Mi-Hee
    • The Journal of the Korean dental association
    • /
    • v.48 no.8
    • /
    • pp.615-620
    • /
    • 2010
  • Purpose: The short dental implant is considered as possible solution in the alveolar bone height deficient cases. The aim of this study was to evaluate clinical availability of short implants by measuring the marginal bone loss of short length implants and comparing with that of conventional length implants. Materials and Methods: The groups were composed of patients who had received at least one implant. The samples of this study were selected from patients who with functional loading after prosthetic treatment for 1 year follow up period. The implants with a length of 5.7 mm and 6mm were considered short. (Bicon Dental implants, USA). The experiment group was composed of $4.5{\times}6mm$, $5{\times}6mm$, $6{\times}5.7mm$ implants (total 18 implants were placed in 14 patients, 8 on maxilla, 10 on mandible). The control group was composed of $4.5{\times}8mm$, $5{\times}8mm$, $4.5{\times}11mm$, $5{\times}11mm$. All implants were selected only by implants placed on molar area. We evaluated marginal bone loss in radiographic images at baseline (implant loading) and 3, 6, 12 months after loading. Additionally, crown-to-implant ratio was evaluated, and marginal bone loss according to crown-to-implant ratio after functional loading was analyzed. Results: The short implant group had a mean marginal bone level of $-0.52{\pm}0.69mm$; the 8mm group, $-0.22{\pm}0.82mm$; and the II mm group, $-0.10{\pm}1.09mm$ after I year of functional loading. But significant differences were not detected between three groups at every follow-up period. Crown-to-implant ratio in short implant group was $1.55{\pm}0.23$; 8mm group was $1.15{\pm}0.18$; and 11mm group was $0.92{\pm}0.15$. Additionally, significant differences between three groups were founded. (P<.0001) The greatest marginal bone loss after 1 year follow-up was founded at crown-to-implant ratio 1~1.49 range in short implant. Conclusion: The marginal bone loss of short implants was comparable to that of long implants. So, the short implants can be a clinically acceptable option.