• Title/Summary/Keyword: Radiographic Images

검색결과 339건 처리시간 0.022초

Efficacy of reciprocating and rotary retreatment nickel-titanium file systems for removing filling materials with a complementary cleaning method in oval canals

  • Said Dhaimy;Hyeon-Cheol Kim;Lamyae Bedida;Imane Benkiran
    • Restorative Dentistry and Endodontics
    • /
    • 제46권1호
    • /
    • pp.13.1-13.9
    • /
    • 2021
  • Objectives: This study aimed to evaluate and compare the efficacy of the S1 reciprocating system and the D-Race retreatment rotary system for filling material removal and the apical extrusion of debris. Materials and Methods: Sixty-four freshly extracted maxillary canines were shaped with size 10 and size 15 K-files, instrumented using ProTaper Gold under irrigation with 2.5% sodium hypochlorite (NaOCl), obturated according to the principle of thermo-mechanical condensation with gutta-percha and zinc oxide eugenol sealer, and allowed to set for 3 weeks at 37℃. Subsequently, the teeth were divided into a control group (n = 4), the D-Race rotary instrument group (n = 30), and the S1 reciprocating instrument group (n = 30). After classical retreatment, the canals were subjected to a complementary approach with the XP-Endo Shaper. Desocclusol was used as a solvent, and irrigation with 2.5% NaOCl was performed. Each group was divided into subgroups according to the timing of radiographic readings. The images were imported into a software program to measure the remaining filling material, the apical extrusion, and the root canal space. The data were statistically analyzed using the Z-test and JASP graphics software. Results: No significant differences were found between the D-Race and S1 groups for primary retreatment; however, using a complementary cleaning method increased the removal of remnant filling (p < 0.05). Conclusions: Classical removal of canal filling material may not be sufficient for root canal disinfection, although a complementary finishing approach improved the results. Nevertheless, all systems left some debris and caused apical extrusion.

두경부 시상면 정렬과 경추 추간판 퇴행성 변화와의 상관관계 (Correlation of Cervical Disc Degeneration with Sagittal Alignments of Cervical Spine)

  • 전대근;박진영;박중현;윤왕현
    • Clinical Pain
    • /
    • 제18권1호
    • /
    • pp.8-15
    • /
    • 2019
  • Objective: To determine the relationship between cervical sagittal parameters and the degree of the cervical disc degeneration at each cervical level by using cervical plain radiographs and disc degeneration grading. Method: This study analyzed 110 patients with posterior neck pain. Cervical radiographic measurements included the occipito-cervical (O~C2) angle; sagittal Cobb angles of C1~C2, C2~C7; and sagittal vertical axis (SVA) of C1~C7 and C2~C7. The degenerations of cervical discs at each level were evaluated through Pfirrmann grading system by magnetic resonance images of the cervical spine. The correlations between the cervical sagittal measurements and the disc degeneration at each level were analyzed by Spearman's correlation. Results: A significant correlation was found for the C2~C7 angle with disc degenerations at C2~C6 levels. O~C2 angle was correlated significantly with disc degenerations at C2~C4 and C5~C7 levels. There was significant correlation between C1~C2 angle and disc degeneration at C6~C7 level. No significant relationship was found between the cervical SVA and the cervical disc degeneration at all cervical levels. Conclusion: Cervical sagittal parameters representing cervical angles (C2~C7, O~C2, and C1~C2 angles) were significantly correlated with the degree of the cervical disc degeneration. These findings suggest that the loss of the natural cervical lordosis rather than loss of natural SVA could be correlated with progression of the cervical disc degeneration.

Radiographic patterns of periosteal bone reactions associated with endodontic lesions

  • Poorya Jalali;Jessica Riccobono;Robert A. Augsburger;Mehrnaz Tahmasbi-Arashlow
    • Restorative Dentistry and Endodontics
    • /
    • 제48권3호
    • /
    • pp.23.1-23.8
    • /
    • 2023
  • Objectives: The formation of new bone by periosteum due to an insult is called periosteal bone reaction (PBR). This study assessed the cone beam computed tomography (CBCT) patterns of periosteal bone reactions associated with periapical inflammatory lesion (apical periodontitis/periapical rarefying osteitis). Materials and Methods: Twenty-two small field of view CBCT images of patients with PBR were selected from a database of a private practice limited to endodontics. The volume of the periapical inflammatory lesion, the presence of cortical fenestration, the distance of the root apices to the affected cortex, and the location, pattern, and longest diameter of the periosteal reaction were recorded. Statistical analysis was performed using Wilcoxon Ranksum, Fischer's exact, Spearman Correlation Coefficient, and paired t-test. Results: In all cases, periosteal bone reaction manifested as either parallel (90.9%) or irregular (9.1%). No correlation was found between periapical inflammatory lesion volume and the periosteal reaction's longest diameter (p > 0.05). Cortical fenestration was noted in 72.7% of the cases. In addition, the findings showed that periosteal reactions were located mostly on the buccal and were present 53.8% and 100% of the time in the mandible and maxilla, respectively. Conclusions: The periosteal reactions of endodontic origin had a nonaggressive form (i.e., parallel or irregular), and none of the lesions resulted in a periosteal reaction with an ominous Codman's triangle or spicule pattern.

Pathologic conditions associated with impacted third molars: A retrospective study of panoramic radiographs in a Southern Brazilian population

  • Gabriela Brum Cardoso;Gleica Dal' Ongaro Savegnago;Waneza Dias Borges Hirsch;Mariana Boessio Vizzotto;Gabriela Salatino Liedke
    • Imaging Science in Dentistry
    • /
    • 제53권4호
    • /
    • pp.303-312
    • /
    • 2023
  • Purpose: This study investigated the prevalence of developmental and acquired pathologic conditions associated with impacted third molars (3Ms) in a Southern Brazilian population and evaluated whether demographic and tooth characteristics were correlated with the presence of bone or tooth lesions. Materials and Methods: Panoramic radiographs were assessed for developmental (bone-related) or acquired (tooth-related) pathoses associated with impacted upper or lower 3Ms. Data on tooth positioning, tooth development, and patient demographics were collected. A trained, calibrated postgraduate student evaluated all images. Binary and multivariate logistic regression models were used to assess associations between outcomes and the demographic and radiographic variables. The threshold for statistical significance was set at 5% (P<0.05). Results: The sample comprised panoramic radiographs from 2054 patients, predominantly female (59.2%), with a mean age of 27.2±11.5 years. Overall, 4066 impacted 3Ms were evaluated, revealing 471 (11.6%) developmental and 710 (17.5%) acquired pathoses. Among the developmental pathoses, 460 (95.2%) were indicative of dentigerous cysts. Male sex, lower 3M location, vertical or distoangular positioning, and incomplete root formation were associated with an elevated likelihood of developmental pathology. Lower tooth position, complete root formation, and partial eruption were linked to an increased probability of an acquired pathology in the third or second molar. Conclusion: The prevalence of pathologic conditions associated with impacted 3Ms was low. Male sex, lower 3M placement, horizontal or distoangular positioning, and incomplete root formation were associated with developmental pathoses, while lower tooth position, complete root formation, and partial eruption were related to acquired pathoses.

A New Radiation-Shielding Device for Restraining Veterinary Patients

  • Songyi Kim;Minju Lee;Miju Oh;Yooyoung Lee;Jiyoung Ban;Jiwoon Park;Sojin Kim;Uhjin Kim;Jaepung Han;Dongwoo Chang
    • 한국임상수의학회지
    • /
    • 제40권6호
    • /
    • pp.429-437
    • /
    • 2023
  • In veterinary medicine, most radiographic images are obtained by restraining patients, inevitably exposing the restrainer to secondary scattered radiation. Radiation exposure can result in stochastic reactions such as cancer and genetic effects, as well as deterministic reactions such as skin burns, cataracts, and bone marrow suppression. Radiation-shielding equipment, including aprons, thyroid shields, eyewear, and gloves, can reduce radiation exposure. However, the risk of radiation exposure to the upper arms, face, and back remains, and lead aprons and thyroid shields are heavy, restricting movement. We designed a new radiation-shielding system and compared its shielding ability with those of conventional radiation-shielding systems. We hypothesized that the new shielding system would have a wider radiation-shielding range and similar shielding ability. The radiation exposure dose differed significantly between the conventional and new shielding systems in the forehead, chin, and bilateral upper arm areas (p < 0.001). When both systems were used together, the radiation-shielding ability was better than when only one system was used at all anatomical locations (p < 0.01). This study suggests that the new radiation-shielding system is essential and convenient for veterinary radiation workers because it is a step closer to radiation safety in veterinary radiography.

The cumulative survival rate of sandblasted, large-grit, acid-etched dental implants: a retrospective analysis

  • Haeji Yum;Hee-seung Han;Kitae Kim;Sungtae Kim;Young-Dan Cho
    • Journal of Periodontal and Implant Science
    • /
    • 제54권2호
    • /
    • pp.122-135
    • /
    • 2024
  • Purpose: This retrospective study aimed to assess the long-term cumulative survival rate of titanium, sandblasted, large-grit, acid-etched implants over a 10-year follow-up period and investigate the factors affecting the survival rate and change in marginal bone loss (MBL). Methods: The study included 400 patients who underwent dental implant placement at the Department of Periodontology of Seoul National University Dental Hospital (SNUDH) between 2005 and 2015. Panoramic radiographic images and dental records of patients were collected and examined using Kaplan-Meier analysis, Cox proportional hazards regression analysis, and multiple regression analysis to determine the survival rates and identify any factors related to implant failure and MBL. Results: A total of 782 implants were placed with a follow-up period ranging from 0 to 16 years (mean: 8.21±3.75 years). Overall, 25 implants were lost, resulting in a cumulative survival rate of 96.8%. Comparisons of the research variables regarding cumulative survival rate mostly yielded insignificant results. The mean mesial and distal MBLs were 1.85±2.31 mm and 1.59±2.03 mm, respectively. Factors influencing these values included age, diabetes mellitus (DM), jaw location, implant diameter, bone augmentation surgery, and prosthetic unit. Conclusions: This study found that the implant survival rates at SNUDH fell within the acceptable published criteria. The patients' sex, age, DM status, implant location, implant design, implant size, surgical type, bone augmentation, and prosthetic unit had no discernible influence on long-term implant survival. Sandblasted, large-grit, acid-etched implants might offer advantages in terms of implant longevity and consistent clinical outcomes.

Esophageal Leiomyoma: Radiologic Findings in 12 Patients

  • Po Song Yang;Kyung Soo Lee;Soon Jin Lee;Tae Sung Kim;In-Wook Choo;Young Mog Shim;Kwhanmien Kim;Yookyung Kim
    • Korean Journal of Radiology
    • /
    • 제2권3호
    • /
    • pp.132-137
    • /
    • 2001
  • Objective: The aim of our study was to describe and compare the radiologic findings of esophageal leiomyomas. Materials and Methods: The chest radiographic (n = 12), esophagographic (n = 12), CT (n = 12), and MR (n = 1) findings of surgically proven esophageal leiomyomas in 12 consecutive patients [ten men and two women aged 34 - 47 (mean, 39) years] were retrospectively reviewed. Results: The tumors, surgical specimens of which ranged from 9 to 90 mm in diameter, were located in the upper (n = 1), middle (n = 5), or lower esophagus (n = 6). In ten of the 12 patients, chest radiography revealed the tumors as mediastinal masses. Esophagography showed them as eccentric, smoothly elevated filling defects in 11 patients and a multilobulated encircling filling defect in one. In 11 of the 12 patients, enhanced CT scans revealed a smooth (n = 9) or lobulated (n = 2) tumor margin, and attenuation was homogeneously low (n = 7) or iso (n = 4). In one patient, the tumor signal seen on T2-weighted MR images was slightly high. Conclusion: Esophageal leiomyomas, located mainly in the middle or distal esophagus, are consistently shown by esophagography to be mainly eccentrically elevated filling defects and at CT, lesions showing homogeneous low or isoattenuation are demonstrated.

  • PDF

Helical coils augment embolization of the middle meningeal artery for treatment of chronic subdural hematoma: A technical note

  • Arvin R. Wali;Alexander Himstead;Javier Bravo;Michael G. Brandel;Brian R. Hirshman;J. Scott Pannell;Andrew D. Nguyen;David R. Santiago-Dieppa
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • 제25권2호
    • /
    • pp.214-223
    • /
    • 2023
  • Embolization of the middle meningeal artery (MMA) is a safe and effective adjunct in the treatment of chronic subdural hematoma. While prior authors describe the use of coils to assist embolization by preventing reflux through eloquent collaterals, we de- scribe the use of coils to further open the MMA, allowing the administration of greater amounts of embolisate for a more robust embolization. The objective of this study was to demonstrate that helical coils can safely open the MMA following the administration of polyvinyl alcohol (PVA) particles. This allows for more embolisate to be administered into the MMA for more effective treatment. A retrospective review was conducted at our institution including intraoperative images and postoperative clinical and radiographic follow up. Failure rates using MMA embolization with PVA and helical coil augmentation were compared to failure rates in the literature of MMA embolization with PVA or ethylene vinyl-alcohol copolymer alone. A total of 8 cases were reviewed in which this technique was implemented. There were no immediate complications after treatment. All patients that underwent helical coil embolization following the administration of PVA had increased amount of embolisate delivered into the MMA. All patients at follow up had resolution of the subdural hematoma on outpatient imaging. Helical coil embolization allows for more embolisate administration into the MMA and provides a technical advantage for patients that fail traditional techniques of embolization. Case series are taking place to further test this hypothesis and identify the ideal patient population that may gain maximal yield from this novel technique.

전 척추 전.후 방향 검사 시 AEC Mode와 Fix Mode에서 PC-Based Monte Carlo Program을 이용한 장기선량 및 유효선량 평가 (Evaluation of Organ and Effective Dose using A PC-Based Monte Carlo Program in AEC Mode and Fix Mode for the whole spine antero-posterior radiography)

  • 김정진;장성원;박장흠;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.23-31
    • /
    • 2012
  • There are AEC mode and fix mode to exposure when the whole spine antero-posterior radiography is done by using DR equipment. This study compared the utility of fix mode to AEC mode, by evaluating organ dose and effective dose and by examining the quality of radiographic image. GE DEFINIUM 8000 and ART-200X Rando Phantom manufactured by Flukebiometical were used for this study. The Rando phantom was set in front of wall detector of X-rays equipment. AEC mode was set at 80kVp and Fix mode was set at 80kVp, 25mAs, 32mAs, 40mAs, and 50mAs. Whole spine AP image were aquired by combining C, T-L and L-S spine images obtained through 3 exposures. When obtaining C, T-L and L-S spine images, were checked for Air kerma (mGy) value calculated by UNFORS Xi meter attached at the phantom surface of center of radiation field. The effective and organ doses were compared by PCXMC program (PC-Based Monte Carlo Program). The quality of obtained radiographic image was evaluated visually by 3 radiologists using resolution chart. When the effective doses was calculated based on tissue weighting factor of ICRP-103, 1.278mSv was measured by AEC mode, and Fix mode measured 0.405mSv at 25mAs, 0.518mSv at 32mAs, 0.649mSv at 40mAs, and 0.810mSv at 50mAS. In addition, the organ dose measured with esposure at 25mAs by Fix mode was almost equivalent to the organ dose by AEC mode, at the esophagus, thyroid, oral mucosa, salivaly glands located at the cervical spine part, while the organ dose by Fix mode was in general lower than the organ dose by AEC mode at the other organs. When Fix mode at 32mAs, 40mAs, and 50mAs was compared to AEC mode for organ dose in 26 organs, AEC mode had higher measurement in 21 organs but not for than brain, trachea, thyroid, oral mucosa, and salivaly glands which are located at the cervical spine part. The image quality evaluated by resolution test chart was much higher with AEC mode than the quality with Fix mode at all exposure conditions. However, while the image quality of cervical spine exposured at 50mAs by Fix mode was lower than the quality of AEC mode, thoraco-lumbar spine and lumbo-sacral spine were calculated and the quality was similar to AEC mode. Scoliosis occurs mainly at thoraco-lumbar and lumbo-sacral spine, not at cervical spine. Compared to AEC mode, Using the appropriate protocol (80kVp, 50mAs) of fix mode for whole spine AP radiography was thought to be useful because the image quality of the thoraco-lumar and lumbo-sacral spine was similar on AEC mode, Also organ and effective doses can be decreased with Fix mode. Therefore, It is considered that fix mode can be used properly with AEC mode for whole spine AP radiography when considering patient's body posture.

  • PDF

방사선 사진을 이용한 하악 제3대구치와 하치조신경의 관계에 대한 연구 (THE STUDY OF EVALUATION TO RELATIONSHIP BETWEEN THE INFERIOR ALVEOLAR NERVE AND THE MANDIBULAR THIRD MOLAR BY USING RADIOGRAPHIC IMAGE)

  • 김종협;구홍;안진석;국민석;박홍주;오희균
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제32권5호
    • /
    • pp.464-473
    • /
    • 2006
  • Purpose: This study was performed to evaluate relationship between the inferior alveolar nerve injury and the findings of panoramic and tomographic images for preventing inferior alveolar nerve injury after the 3rd molar extraction. Material and Method: From April, 2005 to June, 2005, The 190 patients who visited in the Department of Oral and Maxillofacia Surgery, Chonnam National University Hospital and the panoramic radiographies were taken for extraction of the mandibular third molar, was selected. Among 215 mandibular third molars, Scanora tomographic imagings were taken in the 90 teeth which were overlaped to the mandibular canal in the panoramic imagies. In panoramic radiographies, the angulation, the level, the root morphology, and the superimposition sign of the mandibular third molars with the mandibular canal were evaluated. In the tomographic radiographies, the location and distance of the mandibular third molar from the canal were also evaluated. The relationships between these findings and the inferior alveolar nerve injury were examined. Results: In the panoramic findings, the inferior alveolar nerve injuries were occurred in the darkened roots (5 molars, 7%), the uncontinuous radiopaque image (3 molars, 7%), and the depositioned mandibular canal (2 molars, 10%). In the tomographic findings of 90 molars, 20 molars also had the superimposition imagies. Five molars in those molars (25%) had the inferior alveolar nerve injury after extraction. There were 10 patients who had the inferior alveolar nerve injury. The sensory was began to be recovered in 9 patients, except 1 patient, within 2 weeks, then fully recovered within 3 months. Conclusion: These results indicate that the depth mandibular third molar and the superimposition sign may be related with the risk of the inferior alveolar nerve injury after extraction.