• Title/Summary/Keyword: Radiographic

Search Result 2,464, Processing Time 0.027 seconds

The Effect of Low-Intensity Pulsed Ultrasound on Fracture Healing in the Rabbit Model (토끼모델에서 저강도 맥동초음파가 골절치유에 미치는 영향)

  • Kim, Jong-Man;Yi, Chung-Hwi;Cho, Sang-Hyun;Park, Jung-Mi;Kwon, Hyuk-Cheol;Hwang, Tae-Sun
    • Physical Therapy Korea
    • /
    • v.9 no.1
    • /
    • pp.81-96
    • /
    • 2002
  • The purpose of this research was to determine the effects on the healing of fibular fractures in rabbits of low-intensity pulsed ultrasound (50 $mW/cm^2$ and 500 $mW/cm^2$) applied for periods of 4, 14 and 24 days following fibular osteotomy. Thirty-six male Japanese white rabbits were randomly divided into three groups of twelve for three treatment protocols: (1) ultrasound treatment at intensities of 50 $mW/cm^2$ and 500 $mW/cm^2$ until the 4th day following fibular osteotomy, (2) ultrasound treatment at intensities of 50 $mW/cm^2$ and 500 $mW/cm^2$ until the 14th day following fibular osteotomy, and (3) ultrasound treatment at intensities of 50 $mW/cm^2$ and 500 $mW/cm^2$ until the 24th day following fibular osteotomy. The low-intensity pulsed ultrasound was applied to only one fibula of each rabbit (these served as the experimental group). The other fibula of each rabbit served as the control group. The selection of which fibula was to be treated was made randomly. The animals were sacrificed on the 4th, 14th and 24th day after the start of ultrasound treatments. Percent of trabecular bone area and fibular radiography were carried out to compare the degree of fibular bone healing. A microscope was also used to determine any histologic changes. For statistical differences in radiological changes due to length of treatment period (4, 14 and 24 days respectively), the Wilcoxon signed-ranks test was used to compare the experimental and control groups. For statistical differences in fracture healing due to differences in ultrasound intensity, radiological studies were compared using the Mann-Whitney Test. And, to compute percentage differences in areas of trabecular bone, Two-way analysis of variance (ultrasound intensity x each group) was used. Experiment results were as follows: 1. In animals sacrificed on the 4th day, no difference was found in the radiological studies of the fibulae in the experimental and control groups (p>.05). However, experimental groups showed more rapid bone repair than control group. 2. Both radiographic and percent of trabecular bone area studies showed significant differences in rabbits sacrificed after 14 days. Fracture healing was significantly increased in the experimental group (p<.05) 3. In the animals sacrificed on the 24th day, histologic study showed rapid bone repair but fibular radiologic studies did not show statistical differences between the two groups (p>.05). 4. On the 14th day, bone union on radiograph was significantly more rapid in the treatment group with pulsed ultrasound of 50 $mW/cm^2$ than the group with 500 $mW/cm^2$ (p<.05). Histologic studies showed that both the 14 and 24 days groups had more rapid bone repair in animals treated with 50 $mW/cm^2$ ultrasound intensity than those treated with 500 $mW/cm^2$ intensity. In conclusion, it has been shown that the low-intensity pulsed ultrasound has a positive effect on bone fracture healing in the early stage and the range of pulse ultrasound from 50 $mW/cm^2$ to 500 $mW/cm^2$ is effective for fracture healing. Further study is needed to investigate the influence of pulsed ultrasound on delayed union and non-union in bone fractures and also for the clinical use of low-intensity pulsed ultrasound for bone healing in humans.

  • PDF

The Effect of Positioning with Mechanically Ventilatory Acute Respitatory Failure Patients on Arterial Oxygen Partial Pressure and Alveolar-arterial Oxygen tension (인공호흡기를 부착한 급성 호흡부전 환자에서 폐병변 부위에 따른 체위적용이 동맥혈 가스분압 및 폐포동맥간 산소 분압차에 미치는 영향)

  • Hwang, Hee Joung;Park, Hye Ja
    • Korean Journal of Adult Nursing
    • /
    • v.12 no.2
    • /
    • pp.234-244
    • /
    • 2000
  • It is widely recognized that manipulation of body position takes advantage of the influences of gravity for improving oxygenation. The study aims to determine the effects of positioning(supine, prone, right lateral decubitus and left lateral decubitus positions) applied to the mechanically ventilatory acute respiratory failure patients on arterial oxygen partial pressure($PaO_2$), alveolar arterial oxygen tension difference($AaDO_2$), mean aterial pressure, peak inspiratory pressure and plateau pressure. Thirty two acute respiratory failure patients admitted to the medical intensive care unit at Kangnam St. Mary's Hospital, The Catholic University of Korea from March 1997 to January 1998, were divided into three groups by radiographic evidence of unilateral or bilateral lung disease. In group 1 with dominant right lung disease were twelve subjects, group 2 with dominant left lung disease had eight subjects and group 3 had twelve subjects with bilateral lung disease. The variables were measured in 30 minutes after each position of supine, prone, good lung down lateral decubitus and sick lung down lateral decubitus position. The position order was done at random by Latin squre design. The results are as follows; 1) With group 1 patients, the $PaO_2$ in the left lateral decubitus and prone position were $126.8{\pm}30.8$ mmHg and $106.7{\pm}36.8$ mmHg, respectively(p=0.0001). 2) With group 2 patients, the $PaO_2$ in the prone and the right lateral decubitus position were $121.7{\pm}44.7$ mmHg and $118.5{\pm}31.7$ mmHg, respectively (p=0.0018). 3) With group 3 patients, the $PaO_2$ was $143.6{\pm}36.6$ mmHg in the prone position (p=0.0001). 4) With group 1 patients, the $AaDO_2$ in the left lateral decubitus and the right lateral decubitus position were $178.1{\pm}29.7$ mmHg and $233.1{\pm}24.4$ mmHg, respectively(p=0.0001). 5) With group 2 patients, the $AaDO_2$ in the prone and the left lateral decubitus postion were $184.0{\pm}39.5$ mmHg and $231.0{\pm}23.9$ mmHg, respectively(p=0.0019). 6) With group 3 patients, the $AaDO_2$ in the prone and the supine postion were $377.1{\pm}35.6$ mmHg and $435.7{\pm}13.1$ mmHg, respectively (p=0.0001). 7) There were no differences among the mean arterial pressure, peak inspiratory pressure and plateau pressure for each of the supine, prone, left lateral decubitus and right lateral decubitus position. The results suggest that oxygenation may improve in mechanically ventilatory patients with unilateral lung disease when the position is good lung dependent and prone, and patients with bilateral lung disease when the position is prone without any effects on the mean arterial pressure and airway pressure. It is suggested that body positions improve ventilation/perfusion matching and oxygenation need to be specified in patient care plans.

  • PDF

The Analysis of a Cerrobend Compensator and a Electronic Compensator Designed by a Radiation Treatment Planning System (방사선치료계획장치로 설계된 Cerrobend 선량보상체와 전자 선량보상체의 제작 및 특성 분석)

  • Nah Byung-Sik;Chung Woong-Ki;Ahn Sung-Ja;Nam Taek-keun;Yoon Mi-Sun;Song Ju-Young
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.82-88
    • /
    • 2005
  • In this study, the physical compensator made with the high density material, Cerrobend, and the electronic compensator realized by the movement of a dynamic multileaf collimator were analyzed in order to verify the properness of a design function in the commercial RTP (radiation treatment planning) system, Eclipse. The CT images of a phantom composed of the regions of five different thickness were acquired and the proper compensator which can make homogeneous dose distribution at the reference depth was designed in the RTP. The frame for the casting of Cerrobend compensator was made with a computerized automatic styrofoam cutting device and the Millennium MLC-120 was used for the electronic compensator. All the dose values and isodose distributions were measured with a radiographic EDR2 film. The deviation of a dose distribution was $\pm0.99 cGy\;and\;\pm1.82cGy$ in each case of a Cerrobend compensator and a electronic compensator compared with a $\pm13.93 cGy$ deviation in an open beam condition. Which showed the proper function of the designed compensators in the view point of a homogeneous dose distribution. When the absolute dose value was analyzed, the Cerrobend compensator showed a $+3.83\%$ error and the electronic compensator showed a $-4.37\%$ error in comparison with a dose value which was calculated in the RTP. These errors can be admtted as an reasonable results that approve the accuracy of the compensator design in the RTP considering the error in the process of the manufacturing of the Cerrobend compensator and the limitation of a film in the absolute dosimetry.

  • PDF

Arthroscopic Pull-out Suture Repair of Posterior Root Tear of the Medial Meniscus - Minimum 5 Years Follow-up Results - (내측 반월상 연골판 후방 부착부 파열의 관절경적 견인 봉합술 - 최소 5년 추시결과 -)

  • SaKong, Hyub;Shin, Hong Kwan;Lee, Young-Kook;Bae, Ki Cheor;Cho, Chul Hyun;Lee, Kyung Jae;Son, Eun-Seok;Kim, Doo Han
    • Journal of the Korean Arthroscopy Society
    • /
    • v.16 no.2
    • /
    • pp.153-159
    • /
    • 2012
  • Purpose: This study aims at evaluating our results with a 5-year follow up of arthroscopic pull-out suture repair of posterior root tear of the medial meniscus. Materials and Methods: This study enrolled 30 cases who underwent a arthroscopic pull-out suture repair to treat the posterior root tear of the medial meniscus from January 2001 to May 2005 and followed up at least 5 years. The average follow-up period was 76 months (range, 60-90 months). Clinical results by use of the Lysholm knee score and radiographic grade by use of the Kellgren-Lawrence classification were evaluated and second-look arthroscopy was done in all cases. The clinical results were compared with trauma history, obesity, varus deformity and time to operation. Results: At the last follow up, the Lysholm knee score improved from 55 points to 86 points. For the radiological results, 23 cases displayed maintenance or improvement of the medial joint space on the follow up X-ray, but 7 cases displayed decrease of the medial joint space, and 1 case was lately performed total knee replacement due to progressive osteoarthritic change. Conclusion: Arthroscopic pull-out suture repair has a good result at 27 cases (90%) in minimum 5 years follow-up. The clinical improvement was significantly reduced in more severe varus angle.

  • PDF

DEVELOPMENT OF THREE DIMENSIONAL MEASURING PROGRAM WITH FRONTAL AND LATERAL CEPHALOMETRIC RADIOGRAPHS -PART 1. COMPUTATION OF THE THREE-DIMENSIONAL COORDINATES BY COMPENSATION OF THE ERROR OF THE HEAD POSITION IN ORDINARY NON-BIPLANAR CEPHALOSTAT- (정모 및 측모 두부 방사선 규격사진을 이용한 3차원 계측 프로그램의 개발 -1. 단일 방사선원으로 촬영된 두부 방사선사진의 두부 위치 보정을 이용한 3차원 좌표의 산출-)

  • Lee, Geun-Ho;Lee, Sang-Han;Jang, Hyon-Joong;Kwon, Tae-Geon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.3
    • /
    • pp.214-220
    • /
    • 2001
  • The clinical application of the three-dimensional radiographic technique had been limited to standard Broadbent-Bolton cephalometer with biplanar stereoradiography. We developed a new method for compensating the error of head position in ordinary non-biplanar cephalostat. It became to possible to use the three dimensional cephalogram commonly in clinical bases. 1. The method of methemetical compensation of head positioning error in non-biplanar condition was evaluated with dry skull. The error of the method of first and the second trial was $0.46{\pm}1.21$, $0.33{\pm}0.90mm$, which means the error of the head positioning correction in conventional cephalogram was within clinical acceptance. 2. The reproducibility of this system for clinical application was 0.54 mm ($-2.99{\sim}2.26mm$) which defines the absolute mean difference of the first and second trial. Compare to the The landmark identification error $1.2{\pm}1.6mm$, the error of the measurement was within the range of landmark identification error. The result indicates the adequate clinical accuracy of the computation of three-dimensional coordinates by compensation of the error of the head position in ordinary non-biplanar cephalostat.

  • PDF

A Study on the Utilization of Diagnostic Equipments and Patient Dose for Diagnostic Radiological Procedures in Korea (진단방사선영역에서 방사선장치의 이용실태 및 환자피폭선량에 관한 조사연구)

  • Kim Youhyun;Choi Jonghak;Kim Sungsoo;Lee Chanhyeup;Cho Pyongkon;Lee Youngbae;Kim Chelmin
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.10-15
    • /
    • 2005
  • IAEA's guidance levels have been provided for western people to the end. Guidance levels lower than the IAEA'S will be necessary in view of Korean people's proportions. Therefore, we need to develope the standard doses for Korean people. And we conducted a nationwide survey of patient dose from x-ray examinations in Korea. In this study, the 278 institutions were selected from Members Book of Korean Hospital Association. The valid response rate was approximately 57.9%. Doses were calculated from the questionnaires by NDD method. We obtained the results were as follows; 1) General radiographic equipments were distributed for 42.0%, fluoroscopic equipments 29.4%, dental equipments 13.2%, CT units 8.1 % and mamographic units 7.2%. 2) According to classification by rectification, three-phase equipments were 29.9%, inverter-type generators 29.5%, single-phase equipments 25.5%, constant voltage units 9.0% and unknown units 6.0%. 3) According to classification by receptor system, film-screen types were 46.8%, CR types 26.8%, DR types 17.7% and unknown types 8.9%. 4) The number of examinations were chest 49.2%, spine 16.8% and abdomen 12.7%. 5) Patient doses were head AP 3.44 mGy, abdomen AP 4.25 mGy and chest PA 0.39 mGy.

  • PDF

Magnetic Resonance Voiding Cystography in the Diagnosis of Vesicoureteral Reflux: Comparative Study with Voiding Cystourethrography (방광요관역류의 진단에 있어서 자기공명 배뇨성 방광조영술의 유용성: 태뇨성 요도방광조영술과의 비교연구)

  • Lee, Sang-Kwon;Chang, Yong-Min;Koo, Ja-Hoon;Ko, Cheol-Woo;Chung, Sung-Kwang;Kim, Tae-Hun;Sohn, Kyung-Sik;Lee, Chang-Hyun;Kim, Young-Hwan
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.85-93
    • /
    • 2000
  • Purpose: To evaluate the availability of magnetic resonance (MRI voiding cystography for the diagnosis of vesicoureteral reflux (VUR) and to compare the sensitivity of MR voiding cystography (MRVC) with that of radiographic voiding cystourethrography (VCUG) in the detection of VUR. Material and Methods : MRVC was performed upon 20 children referred for investigation of VUR. Either coronal T1-weighted spin-echo or spoiled gradient-echo images were obtained before and after transurethral administration of a mixture of normal saline and gadopentetate dimeglumine, and immediately after voiding. The findings of MRVC were compared with those of VCUG performed within 6 months of MRVC. Results 1 VUR was detected in 23 ureterorenal units f16 VUR's by both methods, five VUR's by VCUG, and two VUR's by MRVC). The sensitivity of VCUG and MRVC in detecting VUR was 91.3% (21/23) and 78.3% (18/23), respectively. MRVC detected renal scarring in 15 out of 17 kidneys with scintigraphically detected renal scarring. Conclusion : Although MRVC is slightly less sensitive than VCUG in the detection of VUR, it can be used for the diagnosis of VUR and renal scarring simultaneouslyl and thus will reduce the radiation hazard.

  • PDF

RADIOPACITY COMPARISON OF TOOTH COLORED RESTORATIVE MATERIALS WITH DIGITAL RADIOGRAPHY (디지털 방사선사진술을 이용한 치아색 수복물의 방사선불투과도 비교)

  • Kim, Hyo-Jung;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.4
    • /
    • pp.499-508
    • /
    • 2000
  • The purposes of this study were to evaluate the validity of 2 kinds of digital radiography techniques in evaluating the radiopacity comparison of restorative materials and to determine the relative radiopacities of several kinds of compomer and flow able resin using these techniques. After taking radiographs of an aluminum step wedge, con-elation of optical density calibration curves were evaluated between conventional radiography with transmission densitometer and CD-Dent digital radiography (storage phosphor system) and between conventional one and RVG$^{(R)}$ digital radiography (CCD system). Compomers such as Dyract$^{(R)}$ AP, Compoglass$^{(R)}$, and Dyract flow$^{(R)}$, and flowable resins such as Ultraseal-XT$^{(R)}$ plus$^{TM}$, Revolution$^{TM}$, Aeliteflo$^{TM}$ and Tetric-flow$^{(R)}$ were used. Five specimens of 5mm in diameter and 2 mm thick were fabricated with each material. Radiopacities of the materials were measured using the above radiographic techniques and compared. The results were as follows: 1. When the optical density calibration curves were compared, conventional radiography and both CD-Dent and RVG$^{(R)}$ digital radiographies showed very high inverse correlations (${\gamma}$=-0.95, ${\gamma}$=-0.98 ; p<0.05). 2. All the tested restorative materials showed levels of radiopacity the same as or greater than that of dentin (p<0.05), Radiopacities of Dyract$^{(R)}$ AP, Compoglass$^{(R)}$, and Tetric flow$^{(R)}$ were greater than those of Revolution$^{TM}$, Aeliteflo$^{TM}$, or dentin (p<0.05). 3. Radiopacities of Dyract$^{(R)}$ AP, Compoglass$^{(R)}$, and Tetric flow$^{(R)}$ were shown to be greater than that of enamel when conventional radiography and CD-Dent digital radiography were used (p<0.05). Radiopacity of Dyract flow$^{(R)}$ was shown to be greater than that of Enamel when conventional radiography was used (p<0.05).

  • PDF

EVALUATION OF RADIOPACITY AND DISCRIMINABILITY OF VARIOUS FIBER REINFORCED COMPOSITE POSTS (수종의 섬유 강화 레진 포스트의 방사선 불투과도와 식별도 평가)

  • Lee, Eun-Hye;Choi, Hang-Moon;Park, Se-Hee;Kim, Jin-Woo;Cho, Kyung-Mo
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.3
    • /
    • pp.188-197
    • /
    • 2010
  • The purpose of this study was to compare radiopacity and radiographic discriminability of various FRC-Posts. Six FRC-Posts were investigated ; 1) FRC Postec Plus (Ivoclar Vivadent AG, Schaan, Liechtenstein), 2) Snowlight (Carbotech, Lewis center, OH, USA), 3) Dentin Post (Komet Brasseler, Lamgo, Germany), 4) Rely-X Fiber Post (3M ESPE, St.paul, MN, USA), 5) D.T.-Light Post (BISCO, Schaumburg, IL,USA), 6) Luxapost (DMG, Hamburg, Germany) The radiographs of each post with a reference 1 mm / 2 mm aluminum step-wedge was taken using digital sensor. The optical density were calculated by gray value of $10{\times}10$ pixel and compared in mm Al equivalent at five points. Six maxillary incisors of similar radiopacity were used. Radiographs of posts in Mx. incisors of lingual side of dry mandible were taken. We showed radiographs and asked the questionnaire to 3 radiologists, 3 endodontists, 3 general practitioners. The questionnaire was comprised of choices of the highest, lowest radiopaque individual post and the choices of best discriminable post at apical, coronal area. The following results were obtained. 1. Each post system showed various radiopacity. 2. There was change of discriminability between each post and simulated specimens regardless of examiner. Although each post showed various radiopacity, the difference of radiopacity did not affect on discriminability.

Limited Open Reduction and Internal Fixation of the Tibial Pilon Fractures (제한 절개를 통한 관혈적 정복 및 내고정술을 이용한 경골 Pilon 골절의 치료)

  • Kang, Chung-Nam;Kim, Jong-Oh;Kim, Dong-Wook;Koh, Young-Do;Ko, Sang-Hun;Yoo, Jae-Doo;Hwang, Jun-Ho
    • Journal of Korean Foot and Ankle Society
    • /
    • v.1 no.2
    • /
    • pp.102-111
    • /
    • 1997
  • The tibial Pilon fracture, which is defined as a comminuted intraarticular fracture of the distal tibia, is difficult to manage because high axial compression and rotational forces to the ankle joint result in impaction, severe comminution, metaphyseal disruption and soft tissue damage. There are variable methods of treatment such as manipulation and cast, calcaneal traction and cast, external fixation, pin and plaster, limited open reduction and external fixation, and open reduction and rigid internal fixation. Though most of authors reported better result after a surgical treatment. than that of conservative treatment, many complications such as posttraumatic arthritis and soft tissue problem still remain troublesome. We have reviewed 19 cases of the tibial Pilon fractures in 18 patients which were treated with limited open reduction and internal fixation from September 1993 to May 1996. The results were as follows: 1. The fractures were classified into five types according to the system of Ovadia and Beals, and the most frequent type was type 3 (53%). The most common cause of injury was traffic accident (47%). 2. All of the cases of type 1 and 2, in which the injury of the ankle joint was less severe, revealed good or excellent clinical results. But in type 4 and 5, because the injury is much severe and accurate reduction is difficult, the clinical results were unsatisfaetory. 3. The most frequent complication was posttraumatic osteoarthritis, and which developed in second frequent complication, was developed m the three cases of type 3 in which the radiographic results were less than fair, but there were no correlation with the clinical results. 4. We could markedly reduce the complications related to the soft tissue problem of Pilon fracture by treatment with limited open reduction and internal fixation, and consider that this is a good method of treatment of Pilon fracture when the injury is less severe and accurate reduction is possible.

  • PDF