• 제목/요약/키워드: Radiofrequency (RF)

검색결과 96건 처리시간 0.033초

Impact of Energy and Access Methods on Extrahepatic Tumor Spreading and the Ablation Zone: An Ex vivo Experiment Using a Subcapsular Tumor Model

  • Jin Sil Kim;Youngsun Ko;Hyeyoung Kwon;Minjeong Kim;Jeong Kyong Lee
    • Korean Journal of Radiology
    • /
    • 제20권4호
    • /
    • pp.580-588
    • /
    • 2019
  • Objective: To evaluate the impact of energy and access methods on extrahepatic tumor spreading and the ablation zone in an ex vivo subcapsular tumor mimic model with a risk of extrahepatic tumor spreading. Materials and Methods: Forty-two tumor-mimics were created in bovine liver blocks by injecting a mixture of iodine contrast material just below the liver capsule. Radiofrequency (RF) ablations were performed using an electrode placed parallel or perpendicular to hepatic surface through the tumor mimic with low- and high-power protocols (groups 1 and 2, respectively). Computed tomography (CT) scans were performed before and after ablation. The presence of contrast leak on the hepatic surface on CT, size of ablation zone, and timing of the first roll-off and popping sound were compared between the groups. Results: With parallel access, one contrast leak in group 1 (1/10, 10%) and nine in group 2 (9/10, 90%) (p < 0.001) were identified on post-ablation CT. With perpendicular access, six contrast leaks were identified in each group (6/11, 54.5%). The first roll-off and popping sound were significantly delayed in group 1 irrespective of the access method (p = 0.002). No statistical difference in the size of the ablation zone of the liver specimen was observed between the two groups (p = 0.247). Conclusion: Low-power RF ablation with parallel access is proposed to be effective and safe from extrahepatic tumor spreading in RF ablation of a solid hepatic tumor in the subcapsular location. Perpendicular placement of an electrode to the capsule is associated with a risk of extrahepatic tumor spreading regardless of the power applied.

열플라즈마를 이용한 재료의 표면개질 (Surface modification of materials by thermal plasma)

  • 강성표;이한준;김태희
    • 한국표면공학회지
    • /
    • 제55권6호
    • /
    • pp.308-318
    • /
    • 2022
  • The surface modification and treatment using thermal plasma were reviewed in academic fields. In general, thermal plasma is generated by direct current (DC) and radiofrequency (RF) power sources. Thermal spray coating, a typical commercial process using thermal plasma, is performed by DC thermal plasma, whereas other promising surface modifications have been reported and developed using RF thermal plasma. Beyond the thermal spray coating, physical and chemical surface modifications were attempted widely. Superhydrophobic surface treatment has a very high industrial demand particularly. Besides, RF thermal plasma system for large-area film surface treatment is being developed. Thermal plasma is especially suitable for the surface modification of low-dimensional nanomaterial (e.g., nanotubes) by utilizing high temperature and rapid quenching. It is able to synthesize and modify nanomaterials simultaneously in a one-pot process.

7T 악관절 MRI를 위한 4 채널 스파이럴 RF 코일의 성능개선 (Improvement of a 4-Channel Spiral-Loop RF Coil Array for TMJ MR Imaging at 7T)

  • 김경남;김영보;조장희
    • Investigative Magnetic Resonance Imaging
    • /
    • 제16권2호
    • /
    • pp.103-114
    • /
    • 2012
  • 목적: 7T 악관절 자기공명상의 개선을 위해 제안된 4 채널 스파이럴 코일과 그를 구동시키기 위한 회로는 자기장의 분포, 송신 전용필드, 신호 대 잡음 비, 그리고 악관절 영상에 대하여 일반적인 단일 루프 형태의 코일과 비교되었다. 대상과 방법: 단일 채널 그리고 4 채널 스파이럴 코일은 단일 루프 형태의 코일에 대해 전자기장 시뮬레이션으로 자기장의 분포 및 송신 전용 필드에 대해서 비교 되었고, 7T에서 이를 평가하고자 송신전용 필드와 더불어 자기장의 분포 역시 비교 평가되었다. 결과: 전자기장 시뮬레이션의 결과와 7T 자기공명영상에서 4 채널 스파이럴 코일은 기존에 사용되는 일반적인 구조인 단일 루프 코일에 비해 상대적으로 우수한 자기장의 분포 및 송신 전용 필드를 보였다. 결론: 7T에서는 코일의 구조에 비해 상대적으로 영상화되는 물질의 특성에 더욱더 의존적이나, 각각의 코일은 다른 필드 분포를 나타냄으로써 최적화된 코일은 악관절 영상과 같은 특정 용도로 사용될 수 있음을 확인하였다.

후두신경통 환자에서 시행한 경피적 제2경추신경절 절제술 -증례 보고- (Percutaneous C2 Ganglionotomy in the Management of Occipital Neuralgia -A case report-)

  • 임소영;김수관;신근만;홍순용;최영룡
    • The Korean Journal of Pain
    • /
    • 제9권1호
    • /
    • pp.200-205
    • /
    • 1996
  • Radiofrequency thermocoagulation(RF) techniques are safe and effective methods as compared to neurodestructive procedure. Other advantages are: ability to perform RF lesions under local or sedative anesthesia, rapid recovery period, low incidence of morbidity and mortality, ability to repeat RF lesions, and leaves no significant scarring. We performed C2 ganglionotomy by RF lesion generator on a patient, suffering post-traumatic occipital neuralgia, as the patient did not respond to conservative therapies such as: trigger point injection, TENS, cryotherapy and stretch, occipital nerve block, C2 ganglion block. Prognostic nerve block was performed usng local anesthetics. Excellent effect was conformed before C2 ganglionotomy. This procedure was performed under fluoroscopy. Type RCK-2A Rosomoff Cordotomy kit was used to stabilize the head and neck. Postoperatively, the patient was free of occipital pain and head motions no longer triggered pain. To date, the patient remains symptom free except for some cervical discomfort.

  • PDF

형질전환 미세조류의 고주파 처리 배양을 통한 MAA 생산량 증가 (Production Yield Enhancement of Mycosporine-like amino acid(MAA)s in Transformed Microalgae Culture by Radiofrequency)

  • 서효현;송미영;아툴 쿨카르니;서승석;이택견;모상현
    • 한국산학기술학회논문지
    • /
    • 제15권6호
    • /
    • pp.3799-3804
    • /
    • 2014
  • Mycosporine-like 아미노산(MAAs)은 UV 흡수물질이며, 다양한 해양생물들은 MAAs의 합성과 축적을 통하여 환경자외선의 직 간접적인 영향을 감소시키는 기능을 진화시켜 왔다. 이 연구에서는 미세조류, Chlamydomonas hedleyi에 포도당 전달 단백질인 Glucose transporter 1(Glut-1) 유전자를 pCAM1303 벡터에 도입한 형질전환체를 제작하여, 형질전환체의 바이오매스를 최대로 증가시킬 수 있는 최적의 Glucose 농도와 NH4Cl농도를 결정하고, 고주파(Radiofrequency) 발생장치를 활용한 바이오매스 증가와 함께 MAA를 대량 생산할 수 있는 배양 조건을 확립하였다. 연구결과 고주파 처리를 통한 형질전환 미세조류는 4.13 mg/L(MAAs/DCW)으로 3.23 mg/L(MAAs/DCW)의 고주파 처리 없이 배양한 형질전환체보다 효율이 증가하였다. 이러한 결과는 자외선 A 흡수물질을 인위적으로 증폭시킬 수 있어서, 대량배양한 후 MAAs물질을 분리 및 정제하여 피부자극성이 없는 친환경적인 자외선 차단 화장품 산업화에 크게 기여할 수 있음을 의미한다.

Effect of Perfluorobutane Microbubbles on Radiofrequency Ablation for Hepatocellular Carcinoma: Suppression of Steam Popping and Its Clinical Implication

  • Dong Young Jeong;Tae Wook Kang;Ji Hye Min;Kyoung Doo Song;Min Woo Lee;Hyunchul Rhim;Hyo Keun Lim;Dong Hyun Sinn;Heewon Han
    • Korean Journal of Radiology
    • /
    • 제21권9호
    • /
    • pp.1077-1086
    • /
    • 2020
  • Objective: To evaluate the effect of perfluorobutane microbubbles (Sonazoid®, GE Healthcare) on steam popping during radiofrequency (RF) ablation for treating hepatocellular carcinoma (HCC), and to assess whether popping affects treatment outcomes. Materials and Methods: The institutional review board approved this retrospective study, which included 90 consecutive patients with single HCC, who received percutaneous RF ablation as the first-line treatment. The patients were divided into two groups, based on the presence or absence of the popping phenomenon, which was defined as an audible sound with a simultaneous sudden explosion within the ablation zone as detected via ultrasonography during the procedure. The factors contributing to the popping phenomenon were identified using multivariable logistic regression analysis. Local tumor progression (LTP) and disease-free survival (DFS) were assessed using the Kaplan-Meier method with the log-rank test for performing comparisons between the two groups. Results: The overall incidence of the popping phenomenon was 25.8% (24/93). Sonazoid® was used in 1 patient (4.2%) in the popping group (n = 24), while it was used in 15 patients (21.7%) in the non-popping group (n = 69). Multivariable analysis revealed that the use of Sonazoid® was the only significant factor for absence of the popping phenomenon (odds ratio = 0.10, p = 0.048). There were no significant differences in cumulative LTP and DFS between the two groups (p = 0.479 and p = 0.424, respectively). Conclusion: The use of Sonazoid® has a suppressive effect on the popping phenomenon during RF ablation in patients with HCC. However, the presence of the popping phenomenon may not affect clinical outcomes.

MRI 검사 시 체온상승 효과: 1.5 T vs 3.0 T (Effective of Body Temperature Increasing during Brain MRI scan)

  • 김명성;이종웅;정재은
    • 한국방사선학회논문지
    • /
    • 제11권1호
    • /
    • pp.49-54
    • /
    • 2017
  • MRI장비에서 자장의 세기가 증가 하게 되면 사용하는 RF(Radiofrequency) pulse 또한 증가 하게 되고 이는 MRI 장비 안에 놓인 인체의 체온 상승을 증가 시키게 하는 역할을 하게 된다. 이에 국소부위에서의 열 발생을 알아보고자 젤라틴과 pork sample 이용하여 측정하였다. 본 연구는 2014년 12월 21일부터 2015년 8월 14일까지 153명의 환자를 대상으로 실시하였다. 3대의 MRI(1.5T- 1대, 3.0T- 2대)장비를 사용하여 뇌 또는 간 부위에서 일상적으로 쓰이는 sequence 프로토콜을 동일하게 적용하여 검사하였다. 검사 전 후 체온 측정은 적외선 타입의 귀 체온계(Braun社)를 사용하였으며 대상자의 심리적 상태는 직접 설문을 통하여 파악했다. 임상 환자를 대상으로 한 체온 상승 결과를 보면 3.0T가 1.5T에서보다 평균 $0.15^{\circ}C$정도 높았고(p<0.012) 3.0T내 에서도 Philips제조회사에서 보다 GE社 MRI장비에서 $0.14^{\circ}C$정도 더 높았다. 심인성 상태에 따른 결과를 살펴보면 MRI검사 진행 중 나는 소리에 대한 민감성 정도와 체온상승과의 관계는 무관하였고, 폐쇄성에 대한 응답이 긴장감으로 느꼈다고 대답하는 사람일수록 체온이 더 상승하는 경향을 보였다. 자장의 세기가 높은 MRI장비일수록 RF 반응물질(물, 금속물질)에 의한 화상이나 체온상승으로 인한 위험한 상황발생(체온조절 장해 환자의 경우 고온 손상, 과다 땀 발생으로 인한 탈진)이 나타나지 않도록 환자의 상태를 좀 더 예의 주시하며 MRI검사를 진행할 필요가 있겠다. 높은 자기장을 기반으로 한 MRI장비는 인체에 흡수되는 전자파 흡수율인 SAR를 비례적으로 증가시키므로 앞으로는 RF 코일 성능을 향상하거나 영상의 질을 향상시키기 위한 이미지 프로그램을 개발하는 등 자기장 이외의 방법을 강구하는 것이 필요하다.

Activation of autophagy at cerebral cortex and apoptosis at brainstem are differential responses to 835 MHz RF-EMF exposure

  • Kim, Ju Hwan;Yu, Da-Hyeon;Kim, Hak Rim
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제21권2호
    • /
    • pp.179-188
    • /
    • 2017
  • With the explosive increase in exposure to radiofrequency electromagnetic fields (RF-EMF) emitted by mobile phones, public concerns have grown over the last few decades with regard to the potential effects of EMF exposure on the nervous system in the brain. Many researchers have suggested that RF-EMFs can effect diverse neuronal alterations in the brain, thereby affecting neuronal functions as well as behavior. Previously, we showed that long-term exposure to 835 MHz RF-EMF induces autophagy in the mice brain. In this study, we explore whether shortterm exposure to RF-EMF leads to the autophagy pathway in the cerebral cortex and brainstem at 835 MHz with a specific absorption rate (SAR) of 4.0 W/kg for 4 weeks. Increased levels of autophagy genes and proteins such as LC3B-II and Beclin1 were demonstrated and the accumulation of autophagosomes and autolysosomes was observed in cortical neurons whereas apoptosis pathways were up-regulated in the brainstem but not in the cortex following 4 weeks of RF exposure. Taken together, the present study indicates that monthly exposure to RF-EMF induces autophagy in the cerebral cortex and suggests that autophagic degradation in cortical neurons against a stress of 835 MHz RF during 4 weeks could correspond to adaptation to the RF stress environment. However, activation of apoptosis rather than autophagy in the brainstem is suggesting the differential responses to the RF-EMF stresses in the brain system.

Measurements of Dark Area in Sensing RFID Transponders

  • Kang, J.H.;Kim, J.Y.
    • 센서학회지
    • /
    • 제21권2호
    • /
    • pp.103-108
    • /
    • 2012
  • Radiofrequency(RF) signal is a key medium to the most of the present wireless communication devices including RF identification devices(RFID) and smart sensors. However, the most critical barrier to overcome in RFID application is in the failure rate in detection. The most notable improvement in the detection was from the introduction of EPC Class1 Gen2 protocol, but the fundamental problems in the physical properties of the RF signal drew less attention. In this work, we focused on the physical properties of the RF signal in order to understand the failure rate by noting the existence of the ground planes and noise sources in the real environment. By using the mathematical computation software, Maple, we simulated the distribution of the electromagnetic field from a dipole antenna when ground planes exist. Calculations showed that the dark area can be formed by interference. We also constructed a test system to measure the failure rate in the detection of a RFID transponder. The test system was composed of a fixed RFID reader and an EPC Class1 Gen2 transponder which was attached to a scanner to sweep in the x-y plane. Labview software was used to control the x-y scanner and to acquire data. Tests in the laboratory environment showed that the dark area can be as much as 43 %. One who wants to use RFID and smart sensors should carefully consider the extent of the dark area.

자궁근종 치료를 위한 질경유 초음파 유도하 고주파 자궁근종용해술의 장기간 효과에 대한 임상적 연구 (Clinical Study of Long Term Effect of Transvaginal Ultrasound Guided Radiofrequency Myolysis for Treatment of Uterine Leiomyoma)

  • 이우석;이일한;김동호;이상훈
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제35권1호
    • /
    • pp.77-82
    • /
    • 2008
  • 목 적: 질경유 초음파 유도하 고주파 자궁근종용해술의 임상적인 효과 및 안정성에 대해 분석해 보고자 하였다. 연구방법: 2004년 12월부터 2007년 3월사이에 질경유 초음파 유도하 고주파 자궁근종용해술을 시행받은 109명을 대상으로 하였다. 환자의 평균나이는 $42.8{\pm}5.8$세였고 모두 자궁을 보존하기 원하였다. 시술 전에 이학적 검사와 초음파를 이용한 병변의 크기 측정이 이루어졌다. 추적검사는 시술 후 1주일, 1개월, 3개월, 6개월 후 시행되었으며 동일 의사에 의해 크기 및 부피변화를 측정하였고, 방문 때마다 생리과다, 생리통 등의 근종 특이증상의 호전 유무를 추적 관찰하였다. 결 과: 근종의 평균 최대직경은 $6.1{\pm}0.5\;cm$ 이었고, 고주파용해술에 소요된 시간은 평균 $16.3{\pm}8.5$분이었다. 유의 할만한 크기와 부피의 감소는 시술 1개월 이후부터 발생하였으며 근종의 평균 최대직경은 시술 후 1주일, 1개월, 3개월, 6개월에 각각 $29.9{\pm}4.8%$ (p<0.001), $41.5{\pm}1.5%$ (p=0.05), $46.2{\pm}3.9%$ (p=0.003), $54.6{\pm}6.1%$ (p<0.001)의 감소율을 보였으며 평균 부피는 각각 $44.4{\pm}8.3%$ (p=0.001), $68.1{\pm}4.2%$ (p=0.035), $73.9{\pm}4.8%$ (p=0.042), $84.5{\pm}5.1%$ (p<0.001)의 부피 감소를 보였다. 일시적인 하복통과 출혈의 지속이 각각 3명씩 있었으나 모두 교정되었고 위중한 합병증은 발생되지 않았다. 생리통과 생리과다 등의 증상은 시술 3개월 후 유의하게 감소하였다. 결 론: 질경유 고주파 자궁근종용해술은 자궁을 보존하면서 좋은 효과와 조기 회복이 가능한 안전하고 효과적인 시술법이다.