• Title/Summary/Keyword: Radioactive iodine-131

Search Result 79, Processing Time 0.023 seconds

Selection of a carrying agent for obtaining radioactive methyliodide vapors under dynamic conditions

  • Obruchikov, Alexander V.;Merkushkin, Aleksei O.;Magomedbekov, Eldar P.;Anurova, Olga M.;Vanina, Elena A.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.8
    • /
    • pp.2761-2766
    • /
    • 2021
  • A method for preparing "reagent" for radioactive methyliodide vapors production using an isotopic exchange reaction has been developed. Based on the obtained data of the isotopic exchange efficiency and hydraulic resistance, white fused alumina (700-840 ㎛) was selected as the carrying agent material for "reagent" production. The radioiodine isotopic exchange dependences on such parameters as temperature, gas flow velocity, and the methyliodide concentration in it were determined. Optimal conditions have been selected to achieve 85% of the isotopic exchange rate in 1 h of the experiment. The obtained data allowed to develop an approach to the test of iodine filters for nuclear power plants and to determine their efficiency.

Comparison of the Measured Radiation Dose-rate by the Ionization Chamber and GM(Geiger-Müller) Counter After Radioactive Iodine Therapy in Differentiated Thyroid Cancer Patients (분화성 갑상선암환자의 방사성 요오드 치료시 전리함과 Geiger-Muller계수관에서 방사선량률 측정값 비교)

  • Park, Kwang-hun;Kim, Kgu-hwan
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.565-570
    • /
    • 2016
  • Radioactive iodine($^{131}I$) treatment reduces recurrence and increases survival in patients with differentiated thyroid cancer. However, it is important in terms of radiation safety management to measure the radiation dose rate generated from the patient because the radiation emitted from the patient may cause the exposure. Research methods, it measured radiation dose-rate according to the elapsed time from 1 m from the upper abdomen of the patient by intake of radioactive iodine. Directly comparing the changes over time, high dose rate sensitivity and efficiency is statistically significant, and higher chamber than GM counter(p<0.05). Low dose rate sensitivity and efficiency in the chamber had lower levels than gm counter, but not statistically significant(p>0.05). In this study confirmed the characteristics of calibrated ionization chamber and GM counter according to the radiation intensity during high-dose radioactive iodine therapy by measuring the accurate and rapid radiation dose rate to the patient explains, discharged patients will be reduced to worry about radiation hazard of family and others person.

Controversies about Radioactive Iodine-131 Remnant Ablation in Low Risk Thyroid Cancers: Are We Near A Consensus?

  • Zaman, Maseeh Uz;Fatima, Nosheen;Padhy, Ajit Kumar;Zaman, Unaiza
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.11
    • /
    • pp.6209-6213
    • /
    • 2013
  • Well differentiated thyroid cancers (WDTC), including papillary (80%) and follicular (10%) types, are the most common endocrine cancers globally. Over the last few decades most the diagnosed cases have fallen into low risk categories. Radioactive iodine-131 (RAI) has an established role in reducing recurrence and improving the survival in high risk patients. In patients with primary tumor size <1 cm, RAI is not recommended by many thyroid societies. However, low risk WDTC has been an arena of major controversies, most importantly the role and dose of adjuvant RAI for remnant ablation to minimize chances of recurrence and improving survival. This review is an attempt to update readers about the previous and existing practice based on results of non-randomized trials and evolving trends fueled by recently published randomized studies.

Removal of radioactive methyliodide from the gas stream with a composite sorbent based on polyurethane foam

  • Obruchikov, Alexander V.;Magomedbekov, Eldar P.;Merkushkin, Aleksei O.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.5
    • /
    • pp.1093-1097
    • /
    • 2020
  • A composite iodine sorbent was obtained in the form of porous polymer matrix with activated carbon particles impregnated with triethylenediamine deposited on its surface. A comparative assessment of the radioactive methyliodide capturing efficiency by the composite sorbent and a sample of industrial charcoal sorbent was conducted. It was shown that under the selected testing conditions, the hydraulic resistance of the composite sorbent is lower, and the sorption capacity is higher than that of the industrial charcoal sorbent. A method for comparing the effectiveness of iodine sorbents, based on the calculation of the ratio of the sorption capacity index to the minimum capacity index, needed for the required purification degree was proposed.

Determination of Self-Disposal date by the Analysis of Radioactive Waste Contamination for 1131I Therapy Ward (131I 치료입원실 폐기물 방사능 오염도 분석 및 자체처분가능일자 산출)

  • Kim, Gi-sub;Jung, Haijo;Park, Min-seok;Jeon, Gjin-seong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.3-6
    • /
    • 2013
  • Purpose: The treatment of thyroid cancer patients was continuously increased. According to the increment of thyroid cancer patients, the establishment of iodine therapy site was also increased in each hospital. This treatment involves the administration of radioactive iodine, which will be given in the form of a capsule. Therefore, protections and managements for radioactive source pollution and radiation exposure should be necessary for radiation safety. Among the many problems, the problem of disposing the radioactive wastes was occurred. In this study, The date for self-disposal for radioactive wastes, which were contaminated in clothes, bedclothes and trash, were calculated. Materials and Methods: The number of iodine therapy ward was 15 in Korea Institute of Radiological Medical and Sciences. Recently, 8 therapy wards were operated for iodine therapy patients and others were on standby for emergency treatment ward of any radiation accidents. Radioactive wastes, which were occurred in therapy ward, were clothes, bedclothes, bath cover for patients washing water and food and drink which was leftover by patients. Each sample was hold into the marinelli beaker (clothes, bedclothes, bath covers) and 90 ml beaker (food, drink, and washing water). The activities of collected samples were measured by HpGe MCA device (Multi Channel Analysis, CANBERRA, USA) Results: The storage period for the each kind of radioactive wastes was calculated by equation of storage periods based on the measurement outcomes. The average storage period was 60 days for the case of clothes, and the maximum storage period was 93 days for patient bottoms. The average storage period and the maximum storage period for the trash were 69 days and 97 days, respectively. The leftover foods and drinks had short storage period (the average storage period was 25 days and maximum storage period was 39 days), compared with other wastes. Conclusion: The proper storage period for disposing the radioactive waste (clothes, bedclothes and bath cover) was 100 days by the regulation on self-disposal of radioactive waste. In addition, the storage period for disposing the liquid radioactive waste was 120 days. The current regulation for radioactive waste self-disposing was not suitable for the circumstances of each radioactive therapy facility. Therefore, it was necessary to reduce the leftover food and drinks by adequate table setting for patients, and improve the process and regulation for disposing the short-half life radioactive wastes.

  • PDF

Comparision of I-131 Diagnostic Scan and Therapeutic Scan in Thyroid Carcinoma (갑상선암 환자에서 I-131의 진단적 전신스캔과 치료후 전신스캔의 비교)

  • Lee, Bum-Woo;Lee, Dong-Soo;Moon, Dae-Hyuk;Chung, June-Key;Lee, Myung-Chul;Cho, Bo-Youn;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.24 no.1
    • /
    • pp.80-86
    • /
    • 1990
  • Fifty seven patients with differentiated thyroid carcinoma were performed radioactive iodine-131 whole body scans after administration of diagnostic dose $(2\sim10\;mCi)$ and therapeutic dose $(30\sim150\;mCi)$ within three months. We evaluated the state of radioactive iodine-131 uptakes in whole body scan to detect correct metastasis of thyroid carcinoma. The results are as follows: 1) In 20 of the 57 patients (35%), the therapeutic scan showed the additional uptakes that were not seen in the diagnostic scan. 2) In 9 (64.2%) of the 14 patients who had been received the thyroid ablation theraphy with I-131 previously, new additional lesions were found in the therapeutic scan but only 11 (25%) of the 32 patients who had not been received the thyroid ablation theraphy disclosed new uptake lesions (p < 0.01). 3) The additional uptake lesions of therapeutic scan were significantly more common in the bony metastatic foci (55.7%) than other areas (p < 0.01). In 11 (55%) of 20 patients, additional uptake regions were anterior neck areas (thyroid bed or regional lymph node). We conclude that diagnostic scan with $2\sim5$ mCi I-131 is inadequate in evaluating residual iodine avid tissues of patients with thyroid carcinoma. Also post-theraphy I-131 whole body scan would be important to evaluate the correct staging and prognosis of thyroid carcinoma, and to follow-up patients.

  • PDF

Evaluation of Adsorption Characteristics of Radioactive Iodine (I-131) for Various Materials of Granular Activated Carbon (GAC) (입상활성탄 재질별 방사성 핵종(I-131) 흡착 특성 평가)

  • Park, Hong-Ki;Son, Hee-Jong;Yeom, Hoon-Sik;Kim, Young-Jin;Choi, Jin-Taek;Ryu, Dong-Choon
    • Journal of Environmental Science International
    • /
    • v.24 no.9
    • /
    • pp.1123-1129
    • /
    • 2015
  • This research was performed by means of several different virgin granular activated carbons (GAC) made of each coal, coconut and wood, and the GACs were investigated for an adsorption performance of iodine-131 in a continuous adsorption column. Breakthrough behavior was investigated that the breakthrough points of the virgin two coals-, coconut- and wood-based GACs were observed as bed volume (BV) 7080, BV 5640, BV 5064 and BV 3192, respectively. The experimental results of adsorption capacity (X/M) for iodine-127 showed that two coal- based GACs were highest (208.6 and $139.1{\mu}g/g$), the coconut-based GAC was intermediate ($86.5{\mu}g/g$) and the wood-based GAC was lowest ($54.5{\mu}g/g$). The X/M of the coal-based GACs was 2~4 times higher than the X/M of the coconut-based and wood-based GACs.

Percutaneous Intranodular Injection Therapy of Radioactive Iodine-131 in Treatment of Benign Thyroid Nodules: A Preliminary Study (방사선 요오드-131의 국소주입에 의한 양성 갑상선 결절의 치료)

  • Ha Il-Joo;Lim Dong-Pyo;Yoon Jung-Han;JaeGal Young-Jong;Boom Hee-Seoung
    • Korean Journal of Head & Neck Oncology
    • /
    • v.17 no.2
    • /
    • pp.174-178
    • /
    • 2001
  • Background and Objective: Percutaneous ethanol injection therapy has been used in the treatment of the benign thyroid diseases. Although the reported side-effects of the therapy was mild and transient, some side-effects including local or radiating pain are troublesome to the patients. Radioactive iodine-131($Ra-^{131}I$) also has been effectively and safely used for management of the benign thyroid diseases. So we developed the percutaneous intranodular injection therapy of $Ra-^{131}I$ as an alternative of percutaneous ethanol injection therapy. Materials and Methods: From December 1998 to October 1999, we treated 29 outpatients (25 women and 4 men, mean age: $47{\pm}12$ years). Inclusion criteria were follows; age >30 years, cytologically benign, with normal thyroid function, cold nodule on thyroid scintigram, solid or mixed natured nodules in sonographical evaluation. Nodular volume was estimated by sonography according to the ellipsoid formula. $Ra-^{131}I$(0.1mCi/ml) was administered in a single dose injection. Follow-up studies every 3 months consisted of full history, thyroid function test, and sonography. We determined the therapeutic response is effective if the volume reduction of the nodule occurred above 30%. Results: After at least 3 months follow-up, 11 patients showed effective response, 12 patients showed minimal or unchanged response and 6 patients showed progression. Although side-effects such as injection pain, febrile reaction, and hormonal changes were absent, an infectious complication in injection site was developed from 1 case. Conclusion: Although we need a more prolonged follow-up to evaluate the delayed sequelae, we can suggest that percutaneous intranodular injection therapy of $Ra-^{131}I$ may be an attractive non-surgical treatment in selected cases of benign thyroid nodules.

  • PDF

Analysis of Urine Iodine Excretion Decrease by Two-Week Stringent Low Iodine Diet for Remnant Thyroid Ablation with Radioactive Iodine in Korean Patients with Thyroid Cancer; Prospective Study (한국 갑상선암 환자들에서 잔여갑상선 제거를 위한 방사성요오드 치료 전 2주간의 엄격한 저요오드식이에 의한 소변 내 요오드량 감소 분석; 전향적 연구)

  • Choi, Joon-Hyuk;Kim, Hoon-Il;Park, Jang-Won;Song, Eun-Hoon;Ko, Bong-Jin;Cheon, Gi-Jeong;Kim, Byung-Il
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.5
    • /
    • pp.375-382
    • /
    • 2008
  • A low iodine diet (LID) is the recommended preparation for radioactive iodine treatment. However, the recommended duration and stringency of LID are different among each recommendation. More stringent LID is expected in Korea because Korea is a iodine-rich region. We investigated the decrement of urine iodine excretion by two-week stringent LID for remnant thyroid ablation with radioactive iodine in Korean patients with thyroid cancer, prospectively. Material and Method: From November 2006, patients who referred to our hospital for remnant ablation after total thyroidectomy were included in this study. To decrease total body iodine, our protocol included three strategies. First, we checked medication which could inhibit the radioactive iodine uptake. Second, the date of 1-131 treatment was scheduled at least 3 months later if contrast agent had been used. The last strategy was two-week stringent LID education by specialized nutritionist. Before and after two-week stringent LID, 24hr-urine iodine was analyzed respectively. 24hr-urine creatinine was also analyzed for determining more valid 24hr urine sampling subgroup. Results: Total 51 patients were finally enrolled. Average of 24hr-urine iodine excretion was significantly lowered ($787{\pm}2242\;{\rightarrow}\;85{\pm}85\;{\mu}g/d$, p=0.03) after LID and 74.4% of patients reached below the recommended urine iodine excretion level ($<100\;{\mu}g/d$). In subgroup (n=14), similar results was showed ($505{\pm}666\;{\rightarrow}\;99{\pm}116\;{\mu}g/d$, p=0.05) and 78.6% of patients met the criteria. Conclusion: Most patients could reach below the recommended urine iodine level after two-week stringent LID. Therefore, in our opinion, at least two-week stringent LID should be recommended in Korea.

Capture of Volatile Organic Iodine Species Using Mordenites

  • Tejaswini Vaidya;John P. Stanford;Nicolene van Rooyen;Krishnan Raja;Vivek Utgikar;Piyush Sabharwall
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.21 no.2
    • /
    • pp.205-224
    • /
    • 2023
  • The emission of off-gas streams from used fuel recycling is a concern in nuclear energy usage as they contain radioactive compounds, such as, 3H, 14C, 85Kr, 131I, and 129I that can be harmful to human health and environment. Radioactive iodine, 129I, is particularly troublesome as it has a half-life of more than 15 million years and is prone to accumulate in human thyroid glands. Organic iodides are hazardous even at very low concentrations, and hence the capture of 129I is extremely important. Dynamic adsorption experiments were conducted to determine the efficiency of sodium mordenite, partially exchanged silver mordenite, and fully exchanged silver mordenite for the removal of methyl iodide present at parts per billion concentrations in a simulated off-gas stream. Kinetic analysis of the system was conducted incorporating the effects of diffusion and mass transfer. The possible reaction mechanism is postulated and the order of the reaction and the values of the rate constants were determined from the experimental data. Adsorbent characterization is performed to investigate the nature of the adsorbent before and after iodine loading. This paper will offer a comprehensive understanding of the methyl iodide behavior when in contact with the mordenites.