• Title/Summary/Keyword: Radioactive iodine

Search Result 188, Processing Time 0.022 seconds

The Fabricating and Utilizing of the Transmission Scan Tool for I-131 Whole Body Scan (I-131 전신 스캔을 위한 Transmission Scan Tool 제작과 활용)

  • Shin, Chae-Ho;Pyo, Sung-Jai;Kim, Bong-Su;Cho, Yong-Gyi;Jo, Jin-Woo;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.40-46
    • /
    • 2009
  • Purpose: A whole body scan using a radioactive iodine (I-131) for the patients with differentiated thyroid cancer is generally an useful method to detect the remnant thyroid tissue, recurred lesion or metastasis lesion after a surgery. The high dose treatment using the radioactive iodine recently tends to increase, and a hospitalization wait for the treatment has been delayed for several months. In this hospital, the treatable patients per week were increased in number through expanding a water-purifier tank and the examination time also increased as the I-131 whole body scan patients increased. Improvement for this problem, this research reduce the existing examination time and classifying the lesion's exact position intended to by fabricating and utilizing the transmission scan tool and an excellent resolution for whole body imaging. Materials and Methods: After conducting the whole body scan for patients who visited the department from February to July 2008 and received the I-131 whole body scan using the ORBITER Gamma Camera. A rail was installed in the examination table for the transmission scan for show a contour of surface area and then the transmission image was obtained and fused to the whole body scan through fabricating the tool to put a flood phantom of diluted 2 mCi $^{99m}Tc$-pertechnetate. Results: Fused image of I-131 whole body scan and the transmission scan had the excellent resolution to discriminate an oral cavity or salivary gland region, neck region's lesion, and metastasis region's position through a simple marking, and could reduce the examination time of 8~28 minutes because without the additional local image. Conclusions: In I-131 whole body scan, the transmission scan can accurately show a contour of surface area through the attenuation of radioactivity, and is useful to indicate the remnant thyroid tissue or metastasis lesion's position by improving the resolution through the fusion image with alreadyexecuted I-131 whole body scan. Also, because the additional local image is not necessary, it can reduce the time required for the examination. It will extensively apply to other clinical examinations to be helpful for identifying an anatomical position because it shows the contour of surface area.

  • PDF

A Study on the Effective Half-life after the High Dose Radioactive Iodine (131I) Therapy for Thyroid Cancer Patients (갑상선암 환자에서 고용량 방사성요오드 치료 후 유효반감기에 대한 연구)

  • Kim, Seongcheol;Gwon, DaYeong;Kim, Yongmin
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.597-603
    • /
    • 2017
  • High-dose $^{131}I$ therapy has been generally carried out to remove remaining thyroid tissue or to cure metastasize lesion of patients who received full thyroidectomy due to differentiated thyroid cancers. In case high-dose $^{131}I$ therapy is carried out for a patient, the patient should be hospitalized being isolated for a certain period in order to restrict the amount of exposure to radiation of people at large from the patient within the limit of a level of radiation. Effective half-life is an important value to calculate how family members are exposed to radiation from a patient or to decide the period of isolation of the patient from the family members. Therefore, in this study we calculated the effective decay constant, effective half-life and period of isolation of high-dose $^{131}I$ therapy patient using NM670 SPECT/CT. As a result of carrying out this study, the effective half-life of high-dose $^{131}I$ therapy patients was derived and the time to reach the discharge level of 1.2 GBq was confirmed. When they were compared with each other in each of curative doses, the effective half-life did not have significant difference, but the time when the level of radiation remaining in the interior of the body to reach the criteria of isolation and discharge showed significant difference and it could be confirmed that the higher the curative dose the longer the period of isolation becomes. When the effective half-lives in each type of preparation were compared with each other, they did not show significant difference. However, When the times to reach the level of radiation that is the criteria of isolation and discharge in each type of preparations, they showed significant difference. The cause of the shortening of the isolation period for rhTSH patients group is decided to be low curative dose. Accordingly, if the current national health insurance (the insurance is applied to using of rhTSH in 3.7 GBq or lower) is maintained, while discerning them in each of types of preparation, we would be able to discharge patients at the time earlier than the current period of isolation (2 nights and 3 days).

Results of Radioiodine Treatment for Distant Metastases of Differentiated Thyroid Carcinoma (분화성 갑상선암의 원격 전이에서 방사성옥소 치료 성적)

  • Kim, Yu-Kyeong;Chung, June-Key;Kim, Seok-Ki;Yeo, Jung-Seok;Park, Do-Joon;Jeong, Jae-Min;Lee, Dong-Soo;Cho, Bo-Youn;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.2
    • /
    • pp.107-118
    • /
    • 2000
  • Purpose: To evaluate the effectiveness of radioiodine treatment for metastatic thyroid carcinoma, we reviewed results of radioactive iodine treatment in patients with functional lung or bone metastases. Materials and Methods: Of 760 patients who were treated for differentiated thyroid cancer between 1984 and 1998, we detected pulmonary metastases and bone metastases in 76 patients (10.0%) and 20 patients (2.6%), respectively. Among them, we could evaluate the effectiveness of I-131 therapy in 53 patients with lung metastases and 15 patients with bone metastases. Results: Of 53 patients who received I-131 therapy with a mean cumulative dose of 26.2 GBq (1.1-84.4 GBq) for pulmonary metastases, metastatic lung lesions completely resolved in 19 patients (35.8%) and improved in 22 patients (41.5%). In 13 of 19 patients with complete remission of pulmonary metastases, the total accumulated dose of I-131 was less than 18.5 GBq. We found 43 sites of metastatic bone lesions in 15 patients with bone metastases. Of 29 lesions which received I-131 therapy, metastatic lesions improved in 14 sites (48.3%), but did not change or progress in 15 sites (51.7%) despite the I-131 therapy. Three lesions were completely cured with a combination treatment of surgery(${\pm}$ external radiotherapy) and I-131 therapy, and the other 11 lesions improved. Conclusion: Radioactive iodine treatment gives favorable results for pulmonary metastases. However, for bone metastases, there might be a need to use combination therapy including I-131 and surgery or external irradiation.

  • PDF

Permanent Hypothyroidism after Radioactive Iodine($^{131}I$) Treatment in Diffuse Toxic Goiter (독성미만성갑상선종환자에서 방사성옥소(放射性沃素)($^{131}I$)투여후(投與後) 발생(發生)하는 영구적갑상선기능저하증(永久的甲狀腺機能低下症))

  • Park, Seon-Yang;Lee, Jung-Sang;Lee, Hong-Kyu;Koh, Chang-Soon;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.11 no.1
    • /
    • pp.39-48
    • /
    • 1977
  • Radioactive iodine(RAI), principally $^{131}I$, effectively controls hyperthyroidism in the majority of patients. The subsequent development of hypothyroidism, however, has been of increasing concern since it was first pointed out by Chapman and Maloof in 1955. And the steady increase of late hypothyroidism during the passage of time was known with its relation with dosage of RAI. The authors have investigated the development of hypothyroidism in 935 patients with diffuse toxic goiter(DTG) who were treated with ($RAI^{131}I$) at the Seoul National University Hospital from 1960 to 1977 to reveal its relation with the number of RAI treatments, dosage of RAI, age of patients and exophthalmos with the following results. 1) The incidence of hypothyroidism by year after RAI therapy among 631 patients with DTG who were treated with single RAI regimen was 7.4%(1 year), 11.8%(2 year), 16.2%(3 year), 22.1%(4 year) and 25.5%(5 year), and that among 163 patients given multiple RAI treatments was 8.6%(1 year), 10.4%(2 year), 13.3%(3 year), 29.1%(4 year), and 54.1%(5 year)respectively showing much higher year1y increments from 4 years after RAI treatment. in comparison with the former. 2) Among 550 patients in the lower dose group treated with single RAI regimen less than 5.0mCi ($Mean{\pm}S.D.:\;4.3{\pm}0.6mCi$), the incidence of hypothyroidism by year after RAI treatment was 6.8%(1 year), 11.4%(2 year), 15.4%(3 year), while among 81 patients in the higher dose group given single RAI treatment not less than 5.5 mCi ($Mean{\pm}S.D.:\;6.3{\pm}0.5mCi$) it was 12.0%(1 year), 15.4%(2 year) and 20.4%(3 year) respectively. However, the duration till euthyroid state after RAI therapy in the two groups was $5.1{\pm}3.6$ months and $4.8{\pm}2.8$ months respectively showing no statistically signficant difference (p>0.1). 4) The incidence of hypothyroidism after RAI treatment in patients younger than 30 years of age was 4.3%(1 year) and 7.7%(2 year); in patients from 30 years to 49 years of age, 5.8%(1 year) and 11.1%(2 year); and in those older than 50 years, 11.0%(1 year) and 14.4%(2 year). The data revealed rising incidence of hypothyroidism with increase of patients' age. 4) Among 116 patients with exophthalmos the incidence of hypothyroidism by year after RAI treatment was 7.1%(1 year) and 12.1%(2 year) while that among 184 patients without exophthalmos was 7.3%(1 year) and 12.2%(2 year) respectively. With the above data the authors could conclude that the hypothyroidism in patients with DTG who were treated by RAI developed more frequently than reported by others in Korea till now, and increased with the passage of time, the yearly increments from 4 years after RAI treatment increasing markedly in the multiple dose group, and the incidence could be reduced by decreasing the administered RAI doe not increasing the duration till euthyroid state after RAI therapy.

  • PDF

The Effect of Increase in Length and Volume of Source in Radioactive Iodine Thyroid Uptake Rate (갑상선 섭취율 측정에서 선원의 길이와 부피 증가에 따른 영향)

  • Hwang, Dong Hun;Oh, Shin Hyun;Kim, Jung Yul;Kang, Chun Koo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.70-75
    • /
    • 2017
  • Purpose Radioactive iodine thyroid uptake (RAIU) rate is an examination which determines and seeks about general functions of thyroid gland. The size of thyroid gland is normally different between each person, also patients having thyroid diseases have had a variety of size of thyroid gland compared with others. The purpose of this study will investigate about the counting rate which is effected by the geometric factors through the length and volume changes of the source in RAIU rate. Materials and Methods I-131 185 kBq ($5{\mu}Ci$) were placed in a cylindrical phantom of 0.5 cm, 1 cm, 1.5 cm, and 3 cm in diameter, respectively, and saline was added to gradually increase the length by 1 cm in the horizontal and vertical directions to give a change in volume. The source was measured 20 times for 20 seconds from a distance of 25 cm to $364.4keV{\pm}20%$ energy ROI with Captus 3000 thyroid uptake system (Capintec, NJ, USA). Results When the source was located in the transverse direction of the detector, the consequence of one-way ANOVA is that even though the length of source is increased each diameter, there is mostly no significant difference. When the source was located in the longitudinal direction and the counting rate of length 1 cm at all diameter is set to 100%, the average is 92.57% for length 2 cm, 86.1% for 3 cm, 80.69% for 4 cm, 74.82% for 5 cm, and 69.68% at 6 cm. Conclusion According to this study, it is expected that the gap of RAIU rate has been depended on the thickness of thyroid gland as well as the diameter of the beaker. We know that the change of the volume with the increase of the length of the source had less effect on the change of the counting rate. Thus, in order to reduce the error in the measurement of the counting rate with the thyroid uptake rate equipment, an accurate counting rate can be relatively measured if the counting rate which is measured is corrected by thickness or the distance between the thyroid and the thyroid uptake rate equipment is changed.

  • PDF

Dose Rate of Restroom in Facilities using Radioisotope (방사성동위원소 사용시설(내/외) 화장실의 외부선량률)

  • Cho, Yong-Gwi;An, Seong-Min
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.237-246
    • /
    • 2016
  • This study is therefore aimed at measuring the surface dose rate and the spatial dose rate in and outside the radionuclide facility in order to ensure safety of the patients, radiation workers and family care-givers in their use of such equipment and to provide a basic framework for further research on radiation protection. The study was conducted at 4 restrooms in and outside the radionuclide facility of a general hospital in Incheon between May 1 and July 31, 2014. During the study period, the spatial contamination dose rate and the surface contamination dose rate before and after radiation use were measured at the 4 places-thyroid therapy room, PET center, gamma camera room, and outpatient department. According to the restroom use survey by hospitals, restrooms in the radionuclide facility were used not only by patients but also by family care-givers and some of radiation workers. The highest cumulative spatial radiation dose rate was 8.86 mSv/hr at camera room restroom, followed by 7.31 mSv/hr at radioactive iodine therapy room restroom, 2.29 mSv/hr at PET center restroom, and 0.26 mSv/hr at outpatient department restroom, respectively. The surface radiation dose rate measured before and after radiation use was the highest at toilets, which are in direct contact with patient's excretion, followed by the center and the entrance of restrooms. Unsealed radioactive sources used in nuclear medicine are relatively safe due to short half lives and low energy. A patient who received those radioactive sources, however, may become a mobile radioactive source and contaminate areas the patient contacts-camera room, sedation room, and restroom-through secretion and excretion. Therefore, patients administered radionuclides should be advised to drink sufficient amounts of water to efficiently minimize radiation exposure to others by reducing the biological half-life, and members of the public-family care-givers, pregnant women, and children-be as far away from the patients until the dose remains below the permitted dose limit.

The Effect of 131I Therapy by Taking in Laxatives (방사성요오드 치료 시 완하제 투여 효과)

  • Kil, Sang-Hyeong;LEE, Hyo-Yeong;Park, Kwang-Yeol;Jo, Kyung-Nam;Baek, Seung-Jo;Hwang, Kyo-Min;Cho, Seong-Mook;Choi, Jae-Hyeok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.3-9
    • /
    • 2014
  • Purpose: Our goals were to evaluate the effect of high dose radioiodine treatment for thyroid cancer by taking in laxatives. Materials and Methods: Twenty patients(M:F=13:7, age $46.3{\pm}8.1\;yrs$) who underwent high dose radioiodine treatment were seperated into Group 1 taking $^{131}I$ 5,500 MBq and Group 2 with the use of laxatives after taking $^{131}I$ 5,500 MBq. The whole body was scanned 16 hours and 40 hours after taking radioactive iodines by using gamma camera, the ROIs were drawn on the gastro-intestinal tract and thigh for calculation of reduction ratio. At particular time during hospitalization, the radioactivity remaining in the body was measured in 1 meter from patient by using survey meter (RadEye-G10, Thermo Fisher Scientific, USA). Schematic presentation of an Origin 8.5.1 software was used for spatial dose rate. Statistical comparison between groups were done using independent samples t-test. P value less than 0.05 was regarded as statistically significant. Results: The reduction ratio in gastro-intestinal 16 hours and 40 hours after taking laxatives is $42.1{\pm}6.3%$ in Group 1 and $72.1{\pm}6.4%$ in Group 2. The spatial dose rate measured when discharging from hospital was $23.8{\pm}6.7{\mu}Sv/h$ in Group 1 and $8.2{\pm}2.4{\mu}Sv/h$ in Group 2. The radioactivity remaining in the body is much decreased at the patient with laxatives(P<0.05). Conclusion: The use in combination with laxatives is helpful for decreasing radioactivity remaining in the body. The radioactive contamination could be decreased at marginal individuals from patients.

  • PDF

In the Treatment I-131, the Significance of the Research that the Patient's Discharge Dose and Treatment Ward can Affect a Patient's Kidney Function on the Significance of Various Factors (I-131 치료시 환자의 신장기능과 다양한 요인으로 의한 퇴원선량 및 치료병실 오염도의 유의성에 관한 연구)

  • Im, Kwang Seok;Choi, Hak Gi;Lee, Gi Hyun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.1
    • /
    • pp.62-66
    • /
    • 2013
  • Purpose: I-131 is a radioisotope widely used for thyroid gland treatments. The physical half life is 8.01 and characterized by emitting beta and gamma rays which is used in clinical practice for the purpose of acquiring treatment and images. In order to reduce the recurrence rate after surgery in high-risk thyroid cancer patients, the remaining thyroid tissue is either removed or the I-131 is used for treatment during relapse. In cases of using a high dosage of radioactive iodine requiring hospitalization, the patient is administered dosage in the hospital isolation ward over a certain period of time preventing I-131 exposure to others. By checking the radiation amount emitted from patients before discharge, the patients are discharged after checking whether they meet the legal standards (50 uSv/h). After patients are discharged from the hospital, the contamination level is checked in many parts of the ward before the next patients are hospitalized and when necessary, decontamination operations are performed. It is expected that there is exposure to radiation when measuring the ward contamination level and dose check emitted from patients at the time of discharge whereby the radiation exposure by health workers that come from the patients in this process is the main factor. This study analyzed the correlation between discharge dose of patients and ward contamination level through a variety of factors such as renal functions, gender, age, dosage, etc.). Materials and Method: The study was conducted on 151 patients who received high-dosage radioactive iodine treatment at Soon Chun Hyang University Hospital during the period between 8/1/2011~5/31/2012 (Male: Female: 31:120, $47.5{\pm}11.9$, average dosage of $138{\pm}22.4$ mCi). As various factors expected to influence the patient discharge dose & ward contamination such as the beds, floors, bathroom floors, and washbasins, the patient renal function (GFR), age, gender, dosage, and the correlation between the expected Tg & Tg-Tb expected to reflect the remaining tissue in patients were analyzed. Results: In terms of the discharge dose and GFR, a low correlation was shown in the patient discharge dose as the GFR was higher (p < 0.0001). When comparing the group with a dosage of over 150mCi and the group with a lower dosage, the lower dosage group showed a significantly lower discharge dose ($24{\pm}10.4uSv/h$ vs $28.7{\pm}11.8uSv/h$, p<0.05). Age, gender, Tg, Tg-Tb did not show a significant relationship with discharge dose (p> 0.05). The contamination level in each spot of the treatment ward showed no significant relationship with GFR, Tg, Tg-Tb, age, gender, and dosage (p>0.05 ). Conclusion: This study says that discharge of the dose in the patient's body is low in GFR higher and Dosage 150mCi under lower. There was no case of contamination of the treatment ward, depending on the dose and renal association. This suggests that patients' lifestyles or be affected by a variety of other factors.

  • PDF

Serial Changes of Serum Thyroid-Stimulating Hormone after Total Thyroidectomy or Withdrawal of Suppressive Thyroxine Therapy in Patients with Differentiated Thyroid Cancer (분화성 갑상선 암 환자에서 갑상선 전절제술후 또는 갑상선 호르몬 억제 요법 중단에 따른 갑상선 자극호르몬의 변화)

  • Bae, Jin-Ho;Lee, Jae-Tae;Seo, Ji-Hyoung;Jeong, Shin-Young;Jung, Jin-Hyang;Park, Ho-Yong;Kim, Jung-Guk;Ahn, Byeong-Cheol;Sohn, Jin-Ho;Kim, Bo-Wan;Park, June-Sik;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.6
    • /
    • pp.516-521
    • /
    • 2004
  • Background: Radioactive iodine (RAI) therapy and whole-body scanning are the fundamentals of treatment and follow-up of patients with differentiated thyroid cancer. It is generally accepted that a Thyroid-Stimulating Hormone (TSH) level of at least 30 ${\mu}U/ml$ is a prerequisite for the effective use of RAI, and that it requires 4-6 weeks of off-thyroxine to attain these levels. Because thyroxine withdrawal and the consequent hypothyroidism are often poorly tolerated, and occasionally might be hazardous, it is important to be certain that these assumptions are correct. We have measured serial changes in serum TSH after total thyroidectomy or withdrawl of thyroxine in patients with thyroid cancer. Subjects and Methods: Serum TSH levels were measured weekly after thyroidectomy in 10 patients (group A) and after the discontinuation of thyroxine in 12 patients (group B). Symptoms and signs of hypothyroidism were also evaluated weekly by modified Billewicz diagnostic index. Results: By the second week, 78% of group A patients and 17% of group B patients had serum TSH levels ${\geq}30{\mu}U/ml$. By the third week, 89% of group A patients and 90% of group B patients had serum TSH levels ${\geq}30{\mu}U/ml$. By the fourth week, all patients in two groups achieved target TSH levels and there were no overt hypothyroidism. Conclusion: in all patients, serum TSH elevated to the target concentration (${\geq}30{\mu}U/ml$) within 4 weeks without significant manifestation of hypothyroidism. The schedule of RAI administration could be adjusted to fit the needs and circumstances of individual patients with a shorter preparation period than the conventional.

Investigations of the External Dose Rate (${\mu}Sv/h$), the Residual Activity (mCi) and the Excretion Rate (%) of Thyroid Cancer Patients Hospitalized for 3700 MBq (100 mCi) $^{131}I$ Radioiodine Treatment ($^{131}I$ 3700 MBq (100 mCi) Therapy 입원 환자의 선량률(${\mu}Sv/h$), 잔류량(mCi), 배설률(%) 측정)

  • Bae, Gi-Han;Kim, Hwa-Joong;Choi, Jae-Jin;Lee, Won-Guk
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.48-55
    • /
    • 2009
  • Purpose: As Korean nuclear law doesn't have any clear guideline about the dose and the external dose rate(uSv/h) requiring hospitalization in radioactive iodine treated patients, the patients are discharged when they meet the guideline of IAEA Basic Safety Standards(BSS). We measured external dose rate(${\mu}Sv/h$) of inpatient underwent 3700MBq (100 mCi) $^{131}I$ radioiodine treatment and considering external dose rate(${\mu}Sv/h$), residual activity(mCi) and excretion rate(%) we found the time for RA to be lowered from 3700MBq (100 mCi) to 1110 MBq (30 mCi) to give reference to set a guideline for discharge. Materials and Methods: Forty-two patients underwent thyroidectomy and scheduled for radioiodine treatment, who received 3700MBq (100 mCi) of $^{131}I$ orally and had no renal disease were examined. After 1, 2, 4, 8, and 20, 24, 40 hours iodine uptake and before/after the urination, the external dose rate(${\mu}Sv/h$) measured using FH40G-L(Thermo Fisher Scientific Inc., MA) at a distance and a height of 1 m for 20 sec on the average. Results and Conclusions: At 20 hours, the external dose rate was decreased to $49{\pm}13\;{\mu}Sv$/h, namely, 78% of administrated radioactivity was excreted and 814 MBq (30 mCi) was residual, and it met the accepted limit for discharge of (IAEA, BSS) under 1110 MBq (30 mCi) (1 m at 66 uSv/h).

  • PDF