• 제목/요약/키워드: Radio-chromic film

검색결과 3건 처리시간 0.014초

Radiochromic film dosimetry for linac-based stereotactic radiosurgery

  • Han, Seung-Hee;Park, Suk-Won;Oh, Do-Hoon
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.302-304
    • /
    • 2002
  • In linac-based stereotactic radiosurgery, assuring the quality of the planning and delivery of external photon beam requires accurate evaluation of beam parameters, usually including output factors, tissue-phantom ratio and off-axis ratios, and measurement of actual dose distributions from simulated treatment. We're going to test the use of calibrated radio chromic film (Gafchromic film; type MD-55, Nuclear associate) using a Lumiscan 75 digitizer to measure absolute dose and relative dose distributions for linac-based radiosurgery unit Relative dose distribution of a human-style spherical acryl phantom were measured using radiochromic film and calculated by treatment planning system. The absolute dose at the sphere center was measured by radiochromic film and micro chamber (Exradin A-14, 0.009cc). What we want to demonstrate in this work, the 'well selected' radiochromic films when external photon beam are used in linac-based stereotactic radiosurgery are very accurate detector for dosimetry.

  • PDF

Novel polyvinyl alcohol film dosimeter containing 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide dye for high dose application

  • Khalid A. Rabaeh;Ahmed A. Basfar;Issra' M.E. Hammoudeh
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3383-3387
    • /
    • 2023
  • A new dyed polyvinyl alcohol (PVA) film dosimeter based on 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MMT) tetrazolium dye is proposed in this study for measuring high gamma radiation dose. Gamma cell irradiator that contains Co-60 gamma-ray source was used to expose the novel MMT-PVA films to different doses up to 25 kGy. The changed in optical property of irradiated and unirradiated films were characterized by UV-Vis spectrophotometer. The results show that the dose sensitive and the linear range of irradiated films were increased considerably with increase of MMT concentration from 1 to 5 mM. The dose response of dyed PVA film changed substantially with changing relative humidity (12-74%) as well as irradiation temperature (10-40 ℃). The absorbance of the unirradiated films does not change up to 10 days in dark while a significant increase in their absorbance was reported for similar films under fluorescent light. The irradiated dosimeters that kept in dark showed a perfect stability for 54 days. It was found that no obvious impact of dose rate on the irradiated MMT-PVA film dosimeters.

이중으로 집중된 동적 미세 다엽콜리메이터의 선량학적 특성 평가 (Evaluation of Dosimetric Characteristics of a Double-focused Dynamic Micro-Multileaf Collimator (DMLC))

  • 김애란;서재혁;신헌주;박형욱;이기웅;이재춘;김신욱;김지나;박혜리;이희관;강영남
    • 한국의학물리학회지:의학물리
    • /
    • 제26권4호
    • /
    • pp.223-228
    • /
    • 2015
  • 이중으로 집중된 미세 다엽콜리메이터(Double-focused micro Multileaf Collimator: ${\mu}MLC$)는 보통의 다엽콜리메이터(Multileaf Collimator: MLC)에 비하여 조사면 가장자리 부분의 선량을 급격하게 줄여준다. 이러한 특성 때문에, 미세 다엽 콜리메이터는 정위적 방사선 수술과 치료(Stereotactic Radio-Surgery/RadioTtherapy, SRS/SRT)에 사용되어 왔다. 우리는 Elekta Synergy 선형가속기에 이중으로 집중된 동적 미세 다엽콜리메이터(Double-focused Dynamic micro-Multileaf Collimator: DMLC)를 부착하여 선량학적 특성을 평가하였다. 본 연구에서는, 필름(GafChromic EBT2 film), EDGE 다이오드 검출기, 3차원 물 팬텀을 이용하였다. 깊이선량백분율(Percent Depth Dose, PDD), 엽 투과도(leaf leakage), 반그림자(Penumbra)를 측정하였고, 모든 데이터들은 6MV 광자선으로 측정하였다. 그 결과, DMLC가 1% 이내의 투과도를 갖는것을 확인할 수 있었다. DMLC는 이중으로 집중 되는 구조를 가졌기 때문에 반 그림자가 조사야 크기에 대하여 독립적인 것을 확인하였다. 본 연구에서는 DMLC의 선량학적 특성을 바탕으로, Elekta Synergy에 부착된 DMLC의 적용 가능성을 증명하였다.