• Title/Summary/Keyword: Radio meter

Search Result 49, Processing Time 0.03 seconds

Conceptual Design of Small WIG Craft (소형 위그선 개념 설계)

  • Shin, Myung-Soo;Kim, Yoon-Sik;Lee, Gyeong-Joong;Kang, Kuk-Jin;Park, Young-Ha;Lee, Young-yeon
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.43 no.1 s.145
    • /
    • pp.134-146
    • /
    • 2006
  • This paper presents the primary conceptual design results of twenty-passenger class Wing-In-Ground(WIG) effect craft. As a first step, top level requirements were proposed and principal dimensions were determined. Maximum speed in ground effect condition is 150 km/h with two tons payload including passengers. Total weight is estimated as 8.5 tons with 2 tons of thrust. Hull and airfoil sections were designed and self propulsion tests were performed by radio controlled model. Two planing hull forms with the transom stern were proposed and towing tests were performed. The resistance and running attitude were measured and the feasibility is checked for the prototype hull form of the twenty-passenger class WIG craft. The free running tests show the stable smooth running attitude at designed speed. Also this radio controlled model can take off around 0.15 meter wave height. It can be said that the top level requirement for the twenty passenger class WIG ship is satisfied successfully. The design optimization to increase the transport efficiency and safety will be performed in the near future.

Using the Crab Nebula as Polarization Angle Calibrator for the Korean VLBI Network

  • Minchul Kam;Sascha Trippe;Do-Young Byun;Jongho Park;Sincheol Kang;Naeun Shin;Sang-Sung Lee;Taehyun Jung
    • Journal of The Korean Astronomical Society
    • /
    • v.56 no.1
    • /
    • pp.1-9
    • /
    • 2023
  • The Crab nebula is widely used as a polarization angle calibrator for single-dish radio observations because of its brightness, high degree of linear polarization, and well-known polarization angle over a wide frequency range. However, the Crab nebula cannot be directly used as a polarization angle calibrator for single-dish observations with the Korean VLBI Network (KVN), because the beam size of the telescopes is smaller than the size of the nebula. To determine the polarization angle of the Crab nebula as seen by KVN, we use 3C 286, a compact polarized extragalactic radio source whose polarization angle is well-known, as a reference target. We observed both the Crab nebula and 3C 286 with the KVN from 2017 to 2021 and find that the polarization angles at the total intensity peak of the Crab nebula (equatorial coordinates (J2000) R.A. = 05h34m32.3804s and Dec = 22°00'44.0982'') are 154.2° ± 0.3°, 151.0° ± 0.2°, 150.0° ± 1.0°, and 151.3° ± 1.1° at 22, 43, 86, and 94 GHz, respectively. We also find that the polarization angles at the pulsar position (RA = 05h34m31.971s and Dec = 22°00'52.06'') are 154.4° ±0.4°, 150.7° ±0.4°, and 149.0° ± 1.0° for the KVN at 22, 43, and 86 GHz. At 129 GHz, we suggest to use the values 149.0° ± 1.6° at the total intensity peak and 150.2° ± 2.0° at the pulsar position obtained with the Institute for Radio Astronomy in the Millimeter Range (IRAM) 30-meter Telescope. Based on our study, both positions within the Crab nebula can be used as polarization angle calibrators for the KVN single-dish observations.

Quasi-Periodic Oscillations of Off-Limb Flaring Arcade Loops observed in the SDO/HMI Continuum

  • Cho, Il-Hyun;Nakariakov, Valery;Moon, Yong-Jae;Lee, Jin-Yi;Kashapova, Larisa;Cho, Kyung-Suk
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.1
    • /
    • pp.43.2-43.2
    • /
    • 2021
  • In this study, we report oscillations of the total intensity of white light loops in the off-limb solar flare observed in 2017-Sep-10 with the SDO/HMI. The total intensity oscillations are correlated with the area of the flaring loop in the plane of the sky. The oscillatory pattern is well fitted by two consecutive damped oscillations. The period and damping time of the first oscillation are 12.9 minutes and 9.9 minutes, respectively. Those of the second oscillation are 11.7 minutes and 15.4 minutes. The excitation of the oscillations coincides with two consecutive type III radio bursts observed in meter range. Assuming the oscillations are magnetoacoustic waves in the flaring loops with the loop lengths ranging from 30 to 90 Mm, the temperature of the white light emitting loops could be in the range from 0.3 MK to 2.6 MK.

  • PDF

Correlation of Effective Dose and BMI in Radioiodine($^{131}I$) Therapy (방사성옥소($^{131}I$) 치료 시 유효선량과 체질량지수의 상관관계)

  • Shin, Gyoo-Seul;Kim, Gun-Jae;Dong, Kyung-Rae;Kim, Hyun-Soo
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.11-16
    • /
    • 2008
  • Purpose : The aim of this study was to predict radiation dose at 1 meter with BMI(body mass index) in thyroid cancer patients treated with radio-iodine and provide the efficient guideline in the management of patients. Methods : 140 patients from thyroidectomy for thyroid cancer were enrolled. All subjects under went 150 mCi radio-iodine therapy and performed whole body scan 1 week later. BMI(weight divided by square of height) was calculated to evaluate the amount of fatty tissue indirectly. The radiation dose at 1 meter was measured initially and on 2nd days. the relation of values with BMI were analyzed statically. As for the method of statistical analysis, using Med calc Version 9,2,2,0 Program. Results : (1) The initial effective dose was inversely correlated with the BMI. Significance level was 0.0004. (2) We obtained the following formula from the data of initial effective dose and BMI: Y = -30.91X + 350.4(${\mu}Sv/h$)(Y: initial radiation dose, x: Group). (3) After 21.55 hours, than radiation dose was less than those recommended by ICRP or NRC in 53% of the population. Conclusion : Using BMI, the initial radiation dose and 2nd days dose can be predicted in thyroid cancer patients before radio-iodine therapy. It may be used for predicting the time of discharge and control the isolation room. We were able to predict the radiation exposure after discharge using this calculated value.

  • PDF

Velocity Measurement of Stream Water Surface Using Microwave (전자파를 이용한 하천수 표면유속 측정)

  • Lee, Sang-Ho;Lee, Han-Gu;Kim, U-Gu
    • Water for future
    • /
    • v.28 no.6
    • /
    • pp.183-191
    • /
    • 1995
  • Applying microwave, a velocity measurement system has been developed in order to measure the velocity of stream water surface. It's main purpose is the measurement for high velocity of flood water. It is under the developing stage of experimental measurement system. The microwave surface velocity meter uses Doppler effects of microwave. It consists of a radio frequency(RF) part and that of signal processing. Thr RF part has the function of microwave oscillation, reception of reflected wave, and determination of Doppler frequency, etc. Signal processing designates amplification, fast Fourier transform, etx. Various measuring experiments were performed at bridges and a spillway of Taechong re-regulation dam with the microwave velocity meter. Verification test was also made through water tank of ship model test at Research Institute of Ships and Ocean Engineering. It shows 4% error inherent in A/D converter and additional several percentage errors from measurement circumstance. The measuring ranges are from 0.5 to 3.5 m/s. The result shows good linear relationship between carriage velocity and measured velocity, thus proves usefulness as a measuring instrument for flood water velocity. The instrument requires overall re-engineering procedure and number of data should be accumulated and analyzed to treat wind effects and random fluctuations of water surface.

  • PDF

An Efficient Channel Selection and Power Allocation Scheme for TVWS based on Interference Analysis in Smart Metering Infrastructure

  • Huynh, Chuyen Khoa;Lee, Won Cheol
    • Journal of Communications and Networks
    • /
    • v.18 no.1
    • /
    • pp.50-64
    • /
    • 2016
  • Nowadays, smart meter (SM) technology is widely effectively used. In addition, power allocation (PA) and channel selection (CS) are considered problems with many proposed approaches. In this paper, we will suggest a specific scenario for an SM configuration system and show how to solve the optimization problem for transmission between SMs and the data concentrator unit (DCU), the center that collects the data from several SMs, via simulation. An efficient CS with PA scheme is proposed in the TV white space system, which uses the TV band spectrum. On the basic of the optimal configuration requirements, SMs can have a transmission schedule and channel selection to obtain the optimal efficiency of using spectrum resources when transmitting data to the DCU. The optimal goals discussed in this paper are the maximum capacity or maximum channel efficiency and the maximum allowable power of the SMs used to satisfy the quality of service without harm to another wireless system. In addition, minimization of the interference to the digital television system and other SMs is also important and needs to be considered when the solving coexistence scenario. Further, we propose a process that performs an interference analysis scheme by using the spectrum engineering advanced Monte Carlo analysis tool (SEAMCAT), which is an integrated software tool based on a Monte-Carlo simulation method. Briefly, the process is as follows: The optimization process implemented by genetic evolution optimization engines, i.e., a genetic algorithm, will calculate the best configuration for the SM system on the basis of the interference limitation for each SM by SEAMCAT in a specific configuration, which reaches the solution with the best defined optimal goal satisfaction.

Development of $^1H-^{31}P$ Animal RF Coil for pH Measurement Using a Clinical MR Scanner (임상용 MR에서 pH 측정을 위한 동물 실험용 $^1H-^{31}P$ RF 코일 개발)

  • Kim, Eun Ju;Kim, Daehong;Lee, Sangwoo;Heo, Dan;Lee, Young Han;Suh, Jin-Suck
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.52-58
    • /
    • 2014
  • Purpose : To establish a pH measurement system for a mouse tumor study using a clinical scanner, to develop the $^1H$ and 31P radio frequency (RF) coil system and to test pH accuracy with phantoms. Materials and Methods: The $^1H$ and the $^{31}P$ surface coils were designed to acquire signals from mouse tumors. Two coils were positioned orthogonally for geometric decoupling. The pH values of various pH phantoms were calculated using the $^1H$ decoupled $^{31}P$ MR spectrum with the Henderson-Hasselbalch equation. The calculated pH value was compared to that of a pH meter. Results: The mutual coil coupling was shown in a standard $S_{12}$. Coil coupling ($S_{12}$) were -73.0 and -62.3 dB respectively. The signal-to-noise ratio (SNR) obtained from the homogeneous phantom $^1H$ image was greater than 300. The high resolution in vivo mice images were acquired using a $^{31}P$-decoupled $^1H$ coil. The pH values calculated from the $^1H$-decoupled $^{31}P$ spectrum correlated well with the values measured by pH meter ($R^2$=0.97). Conclusion: Accurate pH values can be acquired using a $^1H$-decoupled $^{31}P$ RF coil with a clinical scanner. This two-surface coil system could be applied to other nuclear MRS or MRI.

433 MHz Radio Frequency and 2G based Smart Irrigation Monitoring System (433 MHz 무선주파수와 2G 통신 기반의 스마트 관개 모니터링 시스템)

  • Manongi, Frank Andrew;Ahn, Sung-Hoon
    • Journal of Appropriate Technology
    • /
    • v.6 no.2
    • /
    • pp.136-145
    • /
    • 2020
  • Agriculture is the backbone of the economy of most developing countries. In these countries, agriculture or farming is mostly done manually with little integration of machinery, intelligent systems and data monitoring. Irrigation is an essential process that directly influences crop production. The fluctuating amount of rainfall per year has led to the adoption of irrigation systems in most farms. The absence of smart sensors, monitoring methods and control, has led to low harvests and draining water sources. In this research paper, we introduce a 433 MHz Radio Frequency and 2G based Smart Irrigation Meter System and a water prepayment system for rural areas of Tanzania with no reliable internet coverage. Specifically, Ngurudoto area in Arusha region where it will be used as a case study for data collection. The proposed system is hybrid, comprising of both weather data (evapotranspiration) and soil moisture data. The architecture of the system has on-site weather measurement controllers, soil moisture sensors buried on the ground, water flow sensors, a solenoid valve, and a prepayment system. To achieve high precision in linear and nonlinear regression and to improve classification and prediction, this work cascades a Dynamic Regression Algorithm and Naïve Bayes algorithm.

Estimating Bathroom Water-uses based on Time Series Regression (시계열 회귀모형에 기초한 욕실 내 용수 사용량 추정)

  • Myoung, Sungmin;Kim, Donggeon;Jo, Jinnam
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.8
    • /
    • pp.19-26
    • /
    • 2014
  • Analysis of influential factors on water consumption in households will help predicting the water demand of end-use in household and give an explanation to cause on the change of trend. In this research, the data are gathered by radio telemetry system which is combined electronic flow-meter and wireless communication system in 140 household in Korea. Using this data, we estimate for each residential type to determine liter per capita day. we used real data to predict bathtub and washbowl water-uses and compared the ordinary least square regression model and autoregressive regression error model. The results of this study can be applied in the planning stages of water and waste water facilities.

PERFORMANCE OF THE TRAO 13.7-M TELESCOPE WITH NEW SYSTEMS

  • Jeong, Il-Gyo;Kang, Hyunwoo;Jung, Jaehoon;Lee, Changhoon;Byun, Do-Young;Je, Do-Heung;Kang, Sung-Ju;Lee, Youngung;Lee, Chang Won
    • Journal of The Korean Astronomical Society
    • /
    • v.52 no.6
    • /
    • pp.227-233
    • /
    • 2019
  • We report the performance of the 13.7-meter Taeduk Radio Astronomy Observatory (TRAO) radio telescope. The telescope has been equipped with a new receiver, SEQUOIA-TRAO, a new backend system, FFT2G, and a new VxWorks operating system. The receiver system features a 16-pixel focal plane array using high-performance MMIC preamplifiers; it shows very low system noise levels, with system noise temperatures from 150 K to 450 K at frequencies from 86 to 115 GHz. With the new backend system, we can simultaneously obtain 32 spectra, each with a velocity coverage of 163 km s-1 and a resolution of 0.04 km s-1 at 115 GHz. The new operating system, VxWorks, has successfully handled the LMTMC-TRAO observing software. The main observing method is the on-the-fly (OTF) mapping mode; a position-switching mode is available for small-area observations. Remote observing is provided. The antenna surface has been newly adjusted using digital photogrammetry, achieving a rms surface accuracy better than 130 ㎛. The pointing uncertainty is found to be less than 5" over the entire sky. We tested the new receiver system with multi-frequency observations in OTF mode. The aperture efficiencies are 43±1%, 42±1%, 37±1%, and 33±1%, the beam efficiencies are 45±2%, 48±2%, 46±2%, and 41±2% at 86, 98, 110, and 115 GHz, respectively.