• Title/Summary/Keyword: Radio equipment

Search Result 342, Processing Time 0.018 seconds

The Evaluation of Reconstruction Method Using Attenuation Correction Position Shifting in 3D PET/CT (PET/CT 3D 영상에서 감쇠보정 위치 변화 방법을 이용한 영상 재구성법의 평가)

  • Hong, Gun-Chul;Park, Sun-Myung;Jung, Eun-Kyung;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.172-176
    • /
    • 2010
  • Purpose: The patients' moves occurred at PET/CT scan will cause the decline of correctness in results by resulting in inconsistency of Attenuation Correction (AC) and effecting on quantitative evaluation. This study has evaluated the utility of reconstruction method using AC position changing method when having inconsistency of AC depending on the position change of emission scan after transmission scan in obtaining PET/CT 3D image. Materials and Methods: We created 1 mL syringe injection space up to ${\pm}2$, 6, 10 cm toward x and y axis based on central point of polystyrene ($20{\times}20110$ cm) into GE Discovery STE16 equipment. After projection of syringe with $^{18}F$-FDG 5 kBq/mL, made an emission by changing the position and obtained the image by using AC depending on the position change. Reconstruction method is an iteration reconstruction method and is applied two times of iteration and 20 of subset, and for every emission data, decay correction depending on time pass is applied. Also, after setting ROI to the position of syringe, compared %Difference (%D) at each position to radioactivity concentrations (kBq/mL) and central point. Results: Radioactivity concentrations of central point of emission scan is 2.30 kBq/mL and is indicated as 1.95, 1.82 and 1.75 kBq/mL, relatively for +x axis, as 2.07, 1.75 and 1.65 kBq/mL for -x axis, as 2.07, 1.87 and 1.90 kBq/mL for +y axis and as 2.17, 1.85 and 1.67 kBq/mL for -y axis. Also, %D is yield as 15, 20, 23% for +x axis, as 9, 23, 28% for -x axis, as 12, 21, 20% for +y axis and as 8, 22, 29% for -y axis. When using AC position changing method, it is indicated as 2.00, 1.95 and 1.80 kBq/mL, relatively for +x axis, as 2.25, 2.15 and 1.90 kBq/mL for -x axis, as 2.07, 1.90 and 1.90 kBq/mL for +y axis, and as 2.10, 2.02, and 1.72 kBq/mL for -y axis. Also, %D is yield as 13, 15, 21% for +x axis, as 2, 6, 17% for -x axis, as 9, 17, 17% for +y axis, and as 8, 12, 25% for -y axis. Conclusion: When in inconsistency of AC, radioactivity concentrations for using AC position changing method increased average of 0.14, 0.03 kBq/mL at x, y axis and %D was improved 6.1, 4.2%. Also, it is indicated that the more far from the central point and the further position from the central point under the features that spatial resolution is lowered, the higher in lowering of radioactivity concentrations. However, since in actual clinic, attenuation degree increases more, it is considered that when in inconsistency, such tolerance will be increased. Therefore, at the lesion of the part where AC is not inconsistent, the tolerance of radioactivity concentrations will be reduced by applying AC position changing method.

  • PDF

A Study to Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET/CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Cho, Seok-Won;Park, Hoon-Hee;Kim, Jung-Yul;Ban, Yung-Kak;Lim, Han-Sang;Oh, Ki-Beak;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.159-165
    • /
    • 2010
  • Purpose: Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to $^{99m}Tc$ emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radiotechnologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radiotechnologists. Materials and Methods: Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8$ cm and mean weight: $65.9{\pm}1.4$ kg). Radiation were measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150 and 200 cm. Then, all the procedure was given with a portable radiation shielding on the location of head, chest and abdomen at the distance of 100, 150 and 200 cm and transmittance was calculated. Results: In 10 cm, head (105.40 ${\mu}Sv/h$) was the highest and foot (15.85 ${\mu}Sv/h$) was the lowest. In 200 cm, head, chest and abdomen showed similar. On head, the measured dose rates were 9.56 ${\mu}Sv/h$, 5.23 ${\mu}Sv/h$, and 3.40 ${\mu}Sv/h$ in 100, 150 and 200 cm respectively. When using shielder, it shows 2.24 ${\mu}Sv/h$, 1.67 ${\mu}Sv/h$, and 1.27 ${\mu}Sv/h$ in 100, 150 and 200 cm on head. On chest, the measured dose rates were 8.54 ${\mu}Sv/h$, 4.90 ${\mu}Sv/h$, 3.44 ${\mu}Sv/h$ in 100, 150 and 200 cm, respectively. When using shielder, it shows 2.27 ${\mu}Sv/h$, 1.34 ${\mu}Sv/h$, and 1.13 ${\mu}Sv/h$ in 100, 150 and 200 cm on chest. On abdomen, the measured dose rates were 9.83 ${\mu}Sv/h$, 5.15 ${\mu}Sv/h$ and 3.18 ${\mu}Sv/h$ in 100, 150 and 200cm respectively. When using shielder, it shows 2.60 ${\mu}Sv/h$, 1.75 ${\mu}Sv/h$ and 1.23 ${\mu}Sv/h$ in 100, 150 and 200 cm on abdomen. Transmittance was increased as the distance was expanded. Conclusion: As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the radiotechnologists.

  • PDF