• 제목/요약/키워드: Radiation technology information system

검색결과 198건 처리시간 0.031초

X-선 장치의 기술적 인자의 변화에 따른 선량 비교 평가 (A Comparison of Dose in Changed Technique Factor Using X-ray Imaging System)

  • 한동균;고신관;선종률;윤석환;정재은
    • 대한디지털의료영상학회논문지
    • /
    • 제11권2호
    • /
    • pp.101-107
    • /
    • 2009
  • With the recent development of diagnosis using radiation and increasing demand of the medical treatment, we need to minimize radiation exposure dose. So, This is the method which reduce patient dose by measuring surface dose of radiographic change factor and by comparing theoretical and actual dose, when we take an X-ray which is generally used. By changing the factor of kV, mAs, FSD, whose range is 60 to 120 kV, 20 to 100 mAs, 80 to 180 cm, we compared theoretical surface dose with actual surface dose calculated by the simple calculation program, Bit system, and NDD-M method As a result, when kV and mAs were higher, theoretical surface dose and actual surface dose were more increased. but the higher FSD was, the more decreased surface dose was. According to this, the error were measured about 0.1 to 0.2 mGy in low dose part and about 0.7 to 1.5 mGy in high dose part. Therefore, this shows that theoretical surface dose calculation method is more correct in low dose part than in high dose part. In conclusion, we will have to make constant efforts which can reduce patient and radiographer's exposure dose, studying methods which can predict patient's radiation exposure dose more exactly.

  • PDF

A Study on the SEU in the SRAM to proton Irradiation

  • Lho, Young-Hwan;Park, Bo-Kyun;Kim, Bong-Sun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2295-2297
    • /
    • 2003
  • The major problem encountered in satellite design is EMI (Electro-Magnetic Interference) and EMC (Electro-Magnetic Compatibility). Here, our focus is on the effects of protons on the electronic system. The SEU (Single Event Upset) results from the level change of stored information due to photon radiation and temperature in the space and the nuclear power plant environment. The impact of SEU on PLD (Programmable Logic Devices) technology is most apparent in ROM/SRAM/DRAM devices wherein the state of storage cell can be upset. In this paper, a simple and powerful test techniques is suggested, and the results are presented for the analysis and future reference. The test results are compared with that of JPL test report. In our experiment, the proton radiation facility available at KIRAMS (Korea Institute of Radiological Medical Sciences) has been applied on a commercially available SRAM manufactured by Hynix Semiconductor Company.

  • PDF

Feasibility study of a novel hash algorithm-based neutron activation analysis system for arms control treaty verification

  • Xiao-Suo He;Yao-Dong Dai;Xiao-Tao He;Qing-Hua He
    • Nuclear Engineering and Technology
    • /
    • 제56권4호
    • /
    • pp.1330-1338
    • /
    • 2024
  • Information on isotopic composition and geometric structure is necessary for identifying a true warhead. Nevertheless, such classified information should be protected physically or electronically. With a novel Hash encryption algorithm, this paper presents a Monte Carlo-based design of a neutron activation analysis verification module. The verification module employs a thermal neutron source, a non-uniform mask (physically encrypting information about isotopic composition and geometric structure), a gamma detector array, and a Hash encryption algorithm (for electronic encryption). In the physical field, a non-uniform mask is designed to distort the characteristic gamma rays emitted by the inspected item. Furthermore, as part of the Hash algorithm, a key is introduced to encrypt the data and improve the system resolution through electronic design. In order to quantify the difference between items, Hamming distance is used, which allows data encryption and analysis simultaneously. Simulated inspections of simple objects are used to quantify system performance. It is demonstrated that the method retains superior resolution even with 1% noise level. And the performances of anti-statistical attack and anti-brute force cracking are evaluated and found to be very excellent. The verification method lays a solid foundation for nuclear disarmament verification in the upcoming era.

EXPERIMENTAL STUDY ON MEASUREMENT OF EMISSIVITY FOR ANALYSIS OF SNU-RCCS

  • CHO YUN-JE;KIM MOON OH;PARK GOON-CHERL
    • Nuclear Engineering and Technology
    • /
    • 제38권1호
    • /
    • pp.99-108
    • /
    • 2006
  • SNU-RCCS is a water pool type RCCS (Reactor Cavity Cooling System) developed for VHTR (Very High Temperature Reactor) application by SNU (Seoul National University). Since radiation heat transfer is the major process of passive heat removal in a RCCS, it is important to determine the precise emissivity of the reactor vessel. Review studies have used a constant emissivity in the passive heat removal analysis, even though the emissivity depends on many factors such as temperature, surface roughness, oxidation level, wavelength, direction, atmosphere conditions, etc. Therefore, information on the emissivity of a given material in a real RCCS is essential in order to properly analyze the radiation heat transfer in a VHTR. The objectives of this study are to develop a method for compensation of the factors affecting the emissivity measurement using an infrared thermometer and to estimate the true emissivity from the measured emissivity via the developed method, especially in the SNU-RCCS environment. From this viewpoint, we investigated factors such as the attenuation effect of the window, filling gas, and the effect of background radiation on the emissivity measurements. The emissivity of the vessel surface of the SNU-RCCS facility was then measured using a sight tube. The background radiation was subsequently removed from the measured emissivity by solving a simultaneous equation. Finally, the calculated emissivity was compared with the measured emissivity in a separate emissivity measurement device, yielding good agreement with the emissivity increase with vessel temperature in a range of 0.82 to 0.88.

Dual-Sensor 기반 스테레오 X-선 영상의 3차원 형상복원기술을 이용한 검색 자동화를 위한 연구 (The Study of automated inspection technology using a three-dimensional reconstruction of stereo X-ray image based dual-sensor Environment)

  • 황영관;이남호;김종열
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2014년도 춘계학술대회
    • /
    • pp.695-698
    • /
    • 2014
  • 화물 검색용으로 사용되고 있는 X-선 검색장치는 대상물의 단면 정보만을 제공하고 있기에 검색 대상체의 식별에 어려움이 있어 이에 대한 개선이 요구되어 왔다. 또한 대량의 화물 검색을 효율적으로 수행하기 위해서는 검색시스템에 대한 자동화가 요구되며 자동화를 위해서는 대상체를 식별하기 위한 다양한 식별자가 필요하다. 스테레오 X-ray 시스템은 기존의 검색 장치에 라인센서를 추가하여 검색 대상체에 대한 추가적인 정보를 제공함으로써 검색 효율을 높이도록 고안되었다. 본 논문에서는 선행 연구를 통해 개발된 스테레오 X-선 검색장치를 이용하여 다양한 물체에 대한 검색을 수행하며 형상정보를 복원하여 실제 값과의 비교를 통해 스테레오 방사선 스캔장치에 대한 성능분석을 수행하였다. 또한 본 논문에서 제시하는 3차원 형상복원 알고리즘을 통해 검색시스템을 자동화할 수 있는 새로운 식별자의 제공이 가능하다고 판단된다. 본 연구의 결과는 대형 화물 스캔 장치 및 고속화물 스캔 장치 개발을 위해 활용될 수 있다.

  • PDF

해양 부이용 920 MHz 대역 안테나 (920 MHz Band Antenna for Marine Buoy)

  • 최형동;김성율;이성렬
    • 한국항행학회논문지
    • /
    • 제24권6호
    • /
    • pp.593-600
    • /
    • 2020
  • 해양 IoT 서비스를 위한 장치들은 해양 환경에 강인해야 한다. 특히 바닷물 속에 부유하는 전송 장치는 바닷물의 영향을 덜 받도록 설계되어야 한다. 본 연구에서는 전자 어구 실명제 모니터링 시스템에서 어구 상태를 감시하는 부이에 내장되는 안테나를 설계하고 제작한 결과를 보이고 있다. 안테나의 주파수 대역은 920 MHz이고, 부이의 초소형과 경량화를 위해 PCB 패턴 안테나 구조로 설계 제작되었다. 시뮬레이션 결과 제안한 안테나를 내장한 부이가 바닷물 속에 잠기는 정도가 심할수록 반사 계수 증 RF 특성이 저하되지만 빔의 방사 각도는 안테나 하층부에서 점점 상층부로 옮겨가는 것을 확인하였다. 즉 바닷물의 영향을 많이 받을수록 전파 성능은 저하되지만 방사 특성은 해양 IoT 서비스 환경에 적합하다는 것을 확인하였다. 향후 RF 성능을 개선할 수 있는 안테나 구조를 변경 설계하면 제안한 안테나와 부이는 LPWA (low power wide area) 기반 IoT 네트워크 구현에 기여할 것으로 기대된다.

UWB 시스템용 반사판을 갖는 모노폴 안테나 분석 (Analysis of Monopole Antenna Equipped with a Reflector for UWB Systems)

  • 김영진;최동유
    • 한국정보통신학회논문지
    • /
    • 제23권10호
    • /
    • pp.1261-1268
    • /
    • 2019
  • 본 논문에서는 반사판을 갖는 새로운 모노폴 안테나를 제안 하였다. 제안한 안테나는 TRF-45 기판으로 제작하였으며, 제작한 안테나와 결합한 반사판도 FR-4 기판으로 제작하였다. 안테나 후면에 위치한 반사판으로 인해 후면에 반사되는 전류가 억제되는 것을 확인하였다. 제안한 모노폴 안테나의 대역폭은 2.65 GHz이며, 반사판이 없는 모노폴 안테나의 대역폭은 2.88 GHz이다. 또한, 반사판이 없는 안테나는 E-평면에서 양방향 방사 패턴이 관찰되었으며, H-평면에서는 무지향성의 방사패턴이 관찰되었다. 그러나 반사판을 갖는 안테나의 경우 후방 방사를 억제하며, E-평면과 H-평면에서 지향성 방사를 제공한다.

접힌 구조의 UWB 원형 모노폴 안테나의 특성 연구 (A Study on the Properties of UWB Circular Monopole Antenna with Folded Structure)

  • 임계재;유영태
    • 한국정보전자통신기술학회논문지
    • /
    • 제8권2호
    • /
    • pp.147-151
    • /
    • 2015
  • 본 논문에서는 평면형 원형 모노폴 안테나를 필름형으로 설계하여 UWB 단말기의 내장형 안테나로 사용하는 경우에 좁은 틈새에서 접혀진 구조로 장착되었을 때, 안테나의 성능 변화에 대해 연구하였다. 원형 모노폴 부분을 'ㄷ' 자 대칭 구조로 접었을 때, 입력 임피던스 및 반사계수, 주파수 대역폭, 복사패턴의 변화를 시뮬레이션하고 측정하여 기존의 경우와 성능 변화를 비교하였다. 연구 결과, 접힌 구조의 UWB 원형 모노폴 안테나는 UWB 주파수 대역을 포함하는 2.6 - 12 GHz에서 양호한 반산계수 및 복사 성능을 보이고 있기 때문에 UWB 통신용 단말기의 내장형 안테나로 사용 가능함을 확인할 수 있었다.

Planar Array of a Probe Excited Circular Ring Radiating Bidirectional Pattern

  • Phongcharoenpanich, Chuwong;Sroysuwan, Thanarart;Wounchoum, Phairote;Kosulvit, Sompol;Krairiksh, Monai
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -2
    • /
    • pp.719-722
    • /
    • 2002
  • This paper reports the characteristics of a bidirectional antenna by using a planar array of a probe excited circular ring. The element of a bidirectional antenna is first designed to achieve the maximum directivity. The directivity can be further increased by arranging these elements to form the linear array. There are two types of linear array to be investigated i.e., on axis and off axis arrangement. On-axis linear array yields better directivity than off-axis linear array. Therefore, this orientation is further used to form the planar array. The radiation characteristics of this optimum planar array are rigorously reported. The proposed structure is very useful to extend the distance between the base station in PCT system.

  • PDF

고 에너지 방사선치료 시 GEANT4-DICOM과 TPS간 선량비교 연구 (A Comparative Study on the Dose of GEANT4-DICOM to TPS for High-Energy Radiation Treatment)

  • 곽근탁;김양수;권형철;김정수;이선영
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권6호
    • /
    • pp.567-572
    • /
    • 2018
  • Radiation therapy is one of the beneficial choices in the treatment of cancer. This is a comparison of TPS(Treatment Planning System) and GEANT4-DICOM, which should be preceded by the best radiation therapy. A treatment plan for prostate cancer was established with Eclipse and the point doses 366.1 cGy, 189.1 cGy, 213.4 cGy, 127 cGy, 105.7 cGy of any five prostate, bladder, rectum, right femoral head and left femoral head were identified. GEANT4-DICOM simulation showed that the results of Eclipse and ${\pm}2%$ dose error were confirmed. The monthly X-ray output agreement management value recommended by TG-142 is ${\pm}2%$, which means that the experimental results can be meaningful. In conclusion, GEANT4-DICOM is an infinite way to obtain more extended dose information once the time constraints are overcome in the simulation.