• Title/Summary/Keyword: Radiation technique

Search Result 1,283, Processing Time 0.032 seconds

A Clinical Review of Primary Tracheal Carcinoma (원발성 악성기관종양의 임상적 고찰)

  • Ryu, Jeong-Seon;Cho, Hyun-Myung;Yang, Dong-Gyoo;Lee, Hong-Lyeol;Kim, Se-Kyu;Chang, Joon;Ahn, Chul-Min;Shin, Kye-Chul;Kim, Sung-Kyu;Lee, Won-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.4
    • /
    • pp.766-775
    • /
    • 1997
  • Background : Primary malignant tumors of the trachea are extremely rare entities and account for a mere 0.1 per cent of all malignancies of the respiratory tract. Because of vague localizing signs, symptoms and a usually negative routine chest film, the patients with tracheal tumors are often treated for asthma or chronic obstructive pulmonary disease for considerable period of time before correct diagnosis. Method : We have made a review of the 17 cases of primary tracheal tumors in recent 15 years. We reviewed the clinical features including history of smoking and respiratory symptoms, the official readings of initial routine chest film, the cytologic examination of sputum, the time of delay in diagnosis, and the response according to the therapeutic modalities. Results : Eight out of 9 patients with squamous cell carcinoma(SCC) were above 50 years old, five out of 6 patients with adenoid cystic carcinoma(ACC) were below 50 years old. The most common location of primary tracheal tumors was the upper one-third of trachea in 8 cases(47%). The most frequent symptoms were dyspnea in 13/17 cases(76%) and then stridor or wheezing, cough. and sputum in order. The routine chest roentgenographic examinations were not helpful to diagnose tracheal carcinoma and the cytologic examinations of sputums were helpful to diagnose tracheal carcinoma in only one case with adenocarcinoma. The mean times of delay in diagnosis of patients with sec and ACC were 5 months and 24.9 months respectively. We had bronchial asthma in 8 cases(47%) and tracheal tumors in 4 cases(23%) as initial clinical impression. Conclusion : We would like to perform more comprehensive diagnostic tools(high KVP technique, the fibroptic bronchoscopic examination, chest CT scan etc.) in patients who had the suggestive points for the tracheal tumorse(1. unexplained hemoptysis or hoarsness, 2. inspiratory wheezing or stridor, 3. wax and waning of dyspnea according to changes of position, 4. progressive asthmatics unresponsive to antiasthmatic therapy) and radical resection of tumor or external radiation therapy with curative aim as possible.

  • PDF

A Study of Guide System for Cerebrovascular Intervention (뇌혈관 중재시술 지원 가이드 시스템에 관한 연구)

  • Lee, Sung-Gwon;Jeong, Chang-Won;Yoon, Kwon-Ha;Joo, Su-Chong
    • Journal of Internet Computing and Services
    • /
    • v.17 no.1
    • /
    • pp.101-107
    • /
    • 2016
  • Due to the recent advancement in digital imaging technology, development of intervention equipment has become generalize. Video arbitration procedure is a process to insert a tiny catheter and a guide wire in the body, so in order to enhance the effectiveness and safety of this treatment, the high-quality of x-ray of image should be used. However, the increasing of radiation has become the problem. Therefore, the studies to improve the performance of x-ray detectors are being actively processed. Moreover, this intervention is based on the reference of the angiographic imaging and 3D medical image processing. In this paper, we propose a guidance system to support this intervention. Through this intervention, it can solve the problem of the existing 2D medical images based vessel that has a formation of cerebrovascular disease, and guide the real-time tracking and optimal route to the target lesion by intervention catheter and guide wire tool. As a result, the system was completely composed for medical image acquisition unit and image processing unit as well as a display device. The experimental environment, guide services which are provided by the proposed system Brain Phantom (complete intracranial model with aneurysms, ref H+N-S-A-010) was taken with x-ray and testing. To generate a reference image based on the Laplacian algorithm for the image processing which derived from the cerebral blood vessel model was applied to DICOM by Volume ray casting technique. $A^*$ algorithm was used to provide the catheter with a guide wire tracking path. Finally, the result does show the location of the catheter and guide wire providing in the proposed system especially, it is expected to provide a useful guide for future intervention service.

A Study on Music Summarization (음악요약 생성에 관한 연구)

  • Kim Sung-Tak;Kim Sang-Ho;Kim Hoi-Rin;Choi Ji-Hoon;Lee Han-Kyu;Hong Jin-Woo
    • Journal of Broadcast Engineering
    • /
    • v.11 no.1 s.30
    • /
    • pp.3-14
    • /
    • 2006
  • Music summarization means a technique which automatically generates the most importantand representative a part or parts ill music content. The techniques of music summarization have been studied with two categories according to summary characteristics. The first one is that the repeated part is provided as music summary and the second provides the combined segments which consist of segments with different characteristics as music summary in music content In this paper, we propose and evaluate two kinds of music summarization techniques. The algorithm using multi-level vector quantization which provides a repeated part as music summary gives fixed-length music summary is evaluated by overlapping ration between hand-made repeated parts and automatically generated summary. As results, the overlapping ratios of conventional methods are 42.2% and 47.4%, but that of proposed method with fixed-length summary is 67.1%. Optimal length music summary is evaluated by the portion of overlapping between summary and repeated part which is different length according to music content and the result shows that automatically-generated summary expresses more effective part than fixed-length summary with optimal length. The cluster-based algorithm using 2-D similarity matrix and k-means algorithm provides the combined segments as music summary. In order to evaluate this algorithm, we use MOS test consisting of two questions(How many similar segments are in summarized music? How many segments are included in same structure?) and the results show good performance.

Growth Characteristics of Common Ice Plant (Mesembryanthemum crystallinum L.) on Nutrient Solution, Light Intensity and Planting Distance in Closed-type Plant Production System (완전제어형 식물 생산 시스템에서 배양액, 광도 및 재식거리에 따른 Common Ice Plant의 생육 특성)

  • Cha, Mi-Kyung;Park, Kyoung Sub;Cho, Young-Yeol
    • Journal of Bio-Environment Control
    • /
    • v.25 no.2
    • /
    • pp.89-94
    • /
    • 2016
  • This study was conducted to determine the optimum nutrient solution, pH, irrigation interval, light intensity and planting density to growth of common ice plant (Mesembryanthemum crystallinum L.) in a closed-type plant production system. Three-band radiation type fluorescent lamps with a 12-h photoperiod were used. Nutrient film technique systems with three layers were used for the plant growth system. Environmental conditions, such as air temperature, relative humidity and $CO_2$ concentration were controlled by an ON/OFF operation. Treatments were comparison of the nutrient solution of Horticultural Experiment Station in Japan (NHES) and the nutrient solution of Jeju National University (NJNU), pH 6.0 and 7.0, irrigation interval 5 min and 10 min, light intensity 90 and $180{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$, and within-row spacing 10 cm, 15 cm, 20 cm and 25 cm with between-row spacing 15 cm. Optimum macronutrients were composed N 7.65, P 0.65, K 4.0, Ca 1.6 and Mg $1.0mM{\cdot}L^{-1}$. There were no significant interactions between pH 6.0 and 7.0 about shoot fresh weight and shoot dry weight of common ice plant. Irrigation interval 5 min and 10 min was also the same result. Shoot fresh weight and shoot dry weight were highest at $180{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. Shoot fresh weight and shoot dry weight were decreased according to increasing the planting density. From the above results, we concluded that optimum nutrient solution, optimum levels of pH, irrigation interval, light intensity and planting density were 6.0-7.0 and 10 min, $180{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ and $15{\times}15cm$, respectively for growth of common ice plant in a closed-type plant production system.

Comparison of Irradiated Food with Electron Beam and Gamma-ray by PSL and TL Methods (광자극발광법과 열발광법 분석을 통한 전자선과 감마선 조사식품의 비교 연구)

  • Kim, Kyu-Heon;Kwak, Ji-Young;Yoon, Jin-Ho;Park, Young-Eun;Lee, Jae-Hwang;Park, Yong-Chjun;Jo, Tae-Yong;Lee, Hwa-Jung;Lee, Sang-Jae;Han, Sang-Bae
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.3
    • /
    • pp.258-266
    • /
    • 2013
  • This study was conducted to determine the PSL and TL properties of foods irradiated with electron beam and gamma-ray. 5 kinds of food including cereal, pulse, fish powder, dried vegetable and tea were irradiated at 0 to 10 kGy by electron beam accelerator or $^{60}Co$ gamma-ray irradiator. The PSL analysis showed negative results for most of the non-irradiated samples. Non-irradiated shrimp powder showed intermediate result. Irradiated samples gave negative or intermediate or positive value which presented the limitation of PSL technique. In TL analysis, there were TL glow curves at around $300^{\circ}C$ with low intensity on non-irradiated samples. Maximum peak in the range of $150-250^{\circ}C$ was appeared on irradiated samples. TL ratio obtained by re-irradiation with 1 kGy was less than 0.1 on non-irradiated samples and higher than 0.1 on irradiated samples. Therefore, in PSL measurement, electron-beam irradiated samples could obtain more clear results. TL analysis showed obvious difference between non-irradiated and irradiated samples. But the identification was impossible for the sample of rice and lemon tea. Because of it's low contents of mineral.

Radurization Effect of Korean Mackerel (한국산 고등어의 방사선 조사효과)

  • CHO S. J.;CHOE Y. K.;LEE S. Y.;BYUN S. M.;CHUNG J. R.
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.18 no.3
    • /
    • pp.219-226
    • /
    • 1985
  • To investigate potential application of radurization technique as an effective tool for controlling histamine accumulation, histamine contents were determined in fresh Korean mackerel meat samples irradiated at six dose levels of gamma radiation up to 1 Mrad during 35 day-storage at $0^{\circ},\;5^{\circ}\;and\;10^{\circ}C$. Total bacterial counts, total volatile bases and trimethylamine contents were also estimated. The minimum and maximum doses for Korean mackerel were determined to be 0.2 and 0.5 Mrad, respectively. Irradiation induced redening of fish muscle tissue and redening appeared to be dose dependent. At low doses, this redening contributed positively to the overall sensory qualities. At 0.5 and 1.0 Mrad, on the other hand, meat samples were excessively redened to the extent that red and white muscle layers were not readily distinguishable. No appreciable histamine accumulation occured during entire 35 day-storage in fresh mackerel meats, whether irradiated or not, when they were kept at ice temperature. At $5^{\circ}C$, histamine started to accumulate slightly during late storage in the samples irradiated at low doses. Even in the unirradiated samples, the histamine accumulation did not exceed the level of 10.0 mg per 100g meat until the 28th day at $5^{\circ}C$. At $10^{\circ}C$, however, histamine accumulation in the unirradiated was phenomenal from very early storage and the values reached 827.5 mg per 100g meat by the 35th day, while histamine accumulation in the irradiated was severely suppressed. Irradiation invariably brought about a significant reduction of initial microflora, disrupting normal spoilage pattern. This was reflected in the suppression of not only histamine but also total volatile bases and trimethylamine accumulation during post-irradiation storage at refrigerated temperatures.

  • PDF

Structural Behavior of Mixed $LiMn_2O_4-LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ Cathode in Li-ion Cells during Electrochemical Cycling

  • Yun, Won-Seop;Lee, Sang-U
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.5-5
    • /
    • 2011
  • The research and development of hybrid electric vehicle (HEV), plug-in hybrid electric vehicle (PHEV) and electric vehicle (EV) are intensified due to the energy crisis and environmental concerns. In order to meet the challenging requirements of powering HEV, PHEV and EV, the current lithium battery technology needs to be significantly improved in terms of the cost, safety, power and energy density, as well as the calendar and cycle life. One new technology being developed is the utilization of composite cathode by mixing two different types of insertion compounds [e.g., spinel $LiMn_2O_4$ and layered $LiMO_2$ (M=Ni, Co, and Mn)]. Recently, some studies on mixing two different types of cathode materials to make a composite cathode have been reported, which were aimed at reducing cost and improving self-discharge. Numata et al. reported that when stored in a sealed can together with electrolyte at $80^{\circ}C$ for 10 days, the concentrations of both HF and $Mn^{2+}$ were lower in the can containing $LiMn_2O_4$ blended with $LiNi_{0.8}Co_{0.2}O_2$ than that containing $LiMn_2O_4$ only. That reports clearly showed that this blending technique can prevent the decline in capacity caused by cycling or storage at elevated temperatures. However, not much work has been reported on the charge-discharge characteristics and related structural phase transitions for these composite cathodes. In this presentation, we will report our in situ x-ray diffraction studies on this mixed composite cathode material during charge-discharge cycling. The mixed cathodes were incorporated into in situ XRD cells with a Li foil anode, a Celgard separator, and a 1M $LiPF_6$ electrolyte in a 1 : 1 EC : DMC solvent (LP 30 from EM Industries, Inc.). For in situ XRD cell, Mylar windows were used as has been described in detail elsewhere. All of these in situ XRD spectra were collected on beam line X18A at National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory using two different detectors. One is a conventional scintillation detector with data collection at 0.02 degree in two theta angle for each step. The other is a wide angle position sensitive detector (PSD). The wavelengths used were 1.1950 ${\AA}$ for the scintillation detector and 0.9999 A for the PSD. The newly installed PSD at beam line X18A of NSLS can collect XRD patterns as short as a few minutes covering $90^{\circ}$ of two theta angles simultaneously with good signal to noise ratio. It significantly reduced the data collection time for each scan, giving us a great advantage in studying the phase transition in real time. The two theta angles of all the XRD spectra presented in this paper have been recalculated and converted to corresponding angles for ${\lambda}=1.54\;{\AA}$, which is the wavelength of conventional x-ray tube source with Cu-$k{\alpha}$ radiation, for easy comparison with data in other literatures. The structural changes of the composite cathode made by mixing spinel $LiMn_2O_4$ and layered $Li-Ni_{1/3}Co_{1/3}Mn_{1/3}O_2$ in 1 : 1 wt% in both Li-half and Li-ion cells during charge/discharge are studied by in situ XRD. During the first charge up to ~5.2 V vs. $Li/Li^+$, the in situ XRD spectra for the composite cathode in the Li-half cell track the structural changes of each component. At the early stage of charge, the lithium extraction takes place in the $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component only. When the cell voltage reaches at ~4.0 V vs. $Li/Li^+$, lithium extraction from the spinel $LiMn_2O_4$ component starts and becomes the major contributor for the cell capacity due to the higher rate capability of $LiMn_2O_4$. When the voltage passed 4.3 V, the major structural changes are from the $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component, while the $LiMn_2O_4$ component is almost unchanged. In the Li-ion cell using a MCMB anode and a composite cathode cycled between 2.5 V and 4.2 V, the structural changes are dominated by the spinel $LiMn_2O_4$ component, with much less changes in the layered $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component, comparing with the Li-half cell results. These results give us valuable information about the structural changes relating to the contributions of each individual component to the cell capacity at certain charge/discharge state, which are helpful in designing and optimizing the composite cathode using spinel- and layered-type materials for Li-ion battery research. More detailed discussion will be presented at the meeting.

  • PDF

Measurement of the Mucosal Surface Distance in the Early Gastric Cancer Using CT Gastrography (조기 위암에서 CT Gastrography를 이용한 위점막 표면 거리 측정)

  • Choi, Hyang-Hee;Yu, Wan-Sik;Ryeom, Hun-Kyu;Lee, Jae-Hyuk;Choi, Jae-Jeong;Kim, Hee-Su;Cleary, Kevin;Mun, Seong-Ki;Chung, Ho-Young
    • Journal of Gastric Cancer
    • /
    • v.6 no.3
    • /
    • pp.161-166
    • /
    • 2006
  • Purpose: Recently, the incidence of early gastric cancer (EGC) patients is rapidly increased in Korea. However, they're often not perceptible by surgical palpation or inspection. The aim of this study is 1) to develope a software that can locate the tumor and measure the mucosal distance from an anatomic landmark to the tumor using CT gastrography and 2) to compare the distance measured by the developed software with the distance measured by the pathologic findings. Materials and Methods: Between January 2004 and September 2005, sixty patients (male=45, female=15, mean 57.8 years old) estimated for EGC with preoperative CT scans and undergone gastrectomies in Kyungpook National University Hospital were enrolled in this study. Preoperative CT scans were performed after insufflations of room air via 5 Fr NG tube. The scans included the following parameters: (slice thickness/reconstruction interval: 0.625 mm, kVp: 120, mAs: 200). 3D volume rendering and measurement of the surface distance from the pylorus to the EGC were performed using the developed software. Results: The average difference between the lesion to pylorus distances measured from pathologic specimens and CT gastrography was $5.3{\pm}2.9\;mm(range,\;0{\sim}23\;mm)$. The lesion to pylorus distance measured from CT gastrography was well correlated with that measured from the pathologic specimens (r=0.9843, P<0.001). Conclusion: These results suggest that the surface distance from an anatomic landmark to the EGC can be measured accurately by CT gastrography. This technique could be used for preoperative localization of early gastric carcinomas to determine the optimal extent of surgical resection.

  • PDF

Identification of Pre-pasteurization or Pre-irradiation Treatment in Frozen Crushed Garlic Commercially Available in Korean Market (시판 유통 중인 냉동 다진 마늘의 사전 살균 및 조사처리 여부 판별 모니터링)

  • Kim, Hyo-Young;Ahn, Jae-Jun;Kim, Gui-Ran;Jeong, Jin-Hwa;Park, Ki-Hwan;Kwon, Joong-Ho
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.10
    • /
    • pp.1673-1681
    • /
    • 2013
  • Five different chopped frozen garlic products samples, three from Chinese and two from Korean origins being commercially available products in Korean market, were used to confirm their pre-pasteurization or pre-irradiation status by screening (direct epifluorescent filter technique/aerobic plate counts, DEFT/APC; electronic nose, E-nose; photostimulated luminescence, PSL) and identification (thermoluminescence, TL; electron spin resonance, ESR) techniques. Some parts of samples were gamma-irradiated at 1 kGy to be used as control samples in irradiation history identification. DEFT/APC and e-nose successfully showed distinct results between the domestic and imported samples. The PSL photon counts of all the unknown samples were less than 700 (negative), while most of 1 kGy-irradiated samples gave PSL photon counts more than 5,000 (positive). The domestic unknown samples produced the TL glow peaks after $300^{\circ}C$ or more, whereas the imported samples showed TL peaks at the range of $240{\sim}250^{\circ}C$. A clear TL glow peak was obtained from all irradiated samples at $150{\sim}250^{\circ}C$. The unknown samples of Chinese origin gave radiation-specific cellulose ESR signal that was not shown by domestic samples. A multiple step of applying the physical analytical methods is recommended for the effective identification of irradiation status on chopped frozen garlic products.

Surgical Approaches to the Middle Cranial Base Tumors (중두개와저 종양에 대한 수술적 치료)

  • Kim, Il Seub;Rha, Hyung Kyun;Lee, Kyung Jin;Cho, Kyung Keun;Park, Sung Chan;Park, Hae Kwan;Cho, Jeung Ki;Kang, Jun Ki;Choi, Chang Rhack
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.9
    • /
    • pp.1079-1085
    • /
    • 2001
  • Objective : We analysed various surgical approaches and surgical results of 28 middle cranial base tumors for the purpose of selecting optimal surgical approach to the middle cranial base tumor. Methods : In this retrospective review, 28 patients, including 16 meningioma, 6 trigeminal neurinoma, 2 pituitary adenoma, 2 craniopharyngioma, 1 facial neurinoma, and 1 metastatic tumor, underwent surgical treatment using skull base technique. Of theses, 16 tumors were mainly confined to middle cranial fossae, 5 tumors with extension into both anterior and middle fossa, and 7 tumors with extension into both middle and posterior fossa. Tumors that confined to the middle cranial fossa or extended into the anterior cranial fossa were operated with modified pterional, orbitozygomatic or Dolen'c approach, and tumors that extended into the posterior cranial fossa were operated with anterior, posterior or combined transpetrosal approach. Completeness of tumor resection, surgical outcome, postoperative complication, and follow up result were studied. Results : Total tumor removal was achieved in 9 tumors of 10 tumors that did not extended to the cavernous sinus, and was achieved in 7 tumors of 8 tumors that extended to the lateral wall of the cavernous sinus. Of 10 tumors that extended to the venous channel of the cavernous sinus, only 2 were removed totally. Surgical outcome was excellent in 14 patients, good in 10, fair in 2 and poor in 2. There were no death in this series. Dumbell type tumor which extended into both middle and posterior fossae showed tendency of poor prognosis as compared with tumors that confined middle cranial fossa and extended into both anterior and middle cranial fossa. Postoperative dysfunctions were trieminal hypesthesia in 3, oculomotor nerve palsy in 2, abducens nerve palsy in 2, hemiparesis in 2, cerebellar sign in 1, facial palsy in 1 and hearing impairment in 1. Conclusion : Based on our findings and a review of the literature, we conclude that, when selecting the surgical approach to the middle cranial fossa tumors, the most important factors to be considered were exact location of the tumor mass and existence of the cavernous sinus invasion by tumor mass. We recommend modified pterional or orbitozygomatic approach in cases with tumors located anterior and middle cranial base, without cavernous sinus invasion. In cases with tumors invading into cavernous sinus, we recommend Dolen'c or orbitozygomatic approach. And in lateral wall mass and the cavernous sinus, it is preferred to approach the tumor extradurally. For the tumor involing with middle fossa and posterior fossa(dumbell type) a combined petrosal approach is necessary. In cases with cavernous sinus invasion and internal carotid artery encasement, we recommend subtotal resection of the tumor and radiation therapy to prevent permanent postoperative sequele.

  • PDF