• Title/Summary/Keyword: Radiation survey

Search Result 421, Processing Time 0.029 seconds

Physiological and Ecological Studies of the Vegetation on Ore Deposits (금속광물상에 나타나는 식물에 관한 생리생태학적 연구 3. 괴산 우라늄광지대 식물의 방사선생태학적 징상)

  • Chang, Nam Kee;Chang Soo Mok
    • The Korean Journal of Ecology
    • /
    • v.5 no.4
    • /
    • pp.137-142
    • /
    • 1982
  • From 1975 to 1981, the survey was carried out to find out radioecological effects of uranium ore deposits on natural vegetation in Koisan, Korea. The symptoms of spotty and mosaic chlorosis, and necrosis were observed in flowering plants in the areas of uranium ore deposits at Deok-Peung-Ri A, B, and C in Koisan. Although 13 species were found to be chlorosis and necrosis, foliages observed are small and very rare. The features of these symptoms closely resemble those occured by the effects of heavy meetals. The amount of transparent radiation throughout the depth of soils from uranium radiation sources decreases exponentially. The mean contents in leaves of spotty and mosaik chlorotic plants, and soils were 1.36~1.53 and 5.3~7.4 ppm, respectively.

  • PDF

The Evaluation of Radiation Dose to Embryo/Fetus and the Design of Shielding in the Treatment of Brain Tumors (임산부의 전뇌 방사선 치료에 있어서의 태아의 방사선량 측정 및 차폐 구조의 설계)

  • Cho, Woong;Huh, Soon-Nyung;Chie, Eui-Kyu;Ha, Sung-Whan;Park, Yang-Gyun;Park, Jong-Min;Park, Suk-Won
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.4
    • /
    • pp.203-210
    • /
    • 2006
  • Purpose : To estimate the dose to the embryo/fetus of a pregnant patient with brain tumors, and to design an shielding device to keep the embryo/fetus dose under acceptable levels Materials and Methods : A shielding wall with the dimension of 1.55 m height, 0.9 m width, and 30 m thickness is fabricated with 4 trolleys under the wall. It is placed between a Patient and the treatment head of a linear accelerator to attenuate the leakage radiation effectively from the treatment head, and is placed 1 cm below the lower margin of the treatment field in order to minimize the dose to a patient from the treatment head. An anti-patient scattering neck supporters with 2 cm thick Cerrobend metal is designed to minimize the scattered radiation from the treatment fields, and it is divided into 2 section. They are installed around the patient neck by attach from right and left sides. A shielding bridge for anti-room scattered radiation is utilized to place 2 sheets of 3 mm lead plates above the abdomen to setup three detectors under the lead sheets. Humanoid phantom is irradiated with the same treatment parameters, and with and without shielding devices using TLD, and ionization chambers with and without a build-up cap. Results : The dose to the embryo/fetus without shielding was 3.20, 3.21, 1.44, 0.90 cGy at off-field distances of 30, 40, 50, and 60 cm. With shielding, the dose to embryo/fetus was reduced to 0.88, 0.60, 0.35, 0.25 cGy, and the ratio of the shielding effect varied from 70% to 80%. TLD results were 1.8, 1.2, 0.8, 1.2, and 0.8 cGy. The dose measured by the survey meter was 10.9 mR/h at the patient's surface of abdomen. The dose to the embryo/fetus was estimated to be about 1 cGy during the entire treatment. Conclusion : According to the AAPM Report No 50 regarding the dose limit of the embryo/fetus during the pregnancy, the dose to the embryo/fetus with little risk is less than 5 cGy. Our measurements satisfy the recommended values. Our shielding technique was proven to be acceptable.

A Study on the Safety of a Screening X-ray Laboratory Using Containers in accordance with the COVID 19 Outbreak (COVID 19 유행에 따른 컨테이너를 이용한 선별 X-선 검사실의 안전성에 대한 고찰)

  • Kim, Jae-Seok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.425-431
    • /
    • 2020
  • When a radiation generating device is installed in an export container due to COVID-19, the purpose of this study was to measure the space dose in the radiation room and to study the effectiveness of the shielding wall in the laboratory. Air dose measurement method was set behind the X-ray tube, 50 cm, 100 cm, 200 cm, and measured 12 locations. The dose values before and after the use of the movable radiation shielding wall were compared by measuring 3 locations behind the X-ray tube using the movable radiation shielding wall. The measured values were 50 cm on the left behind the X-ray tube: 1.446 μSv, behind the X-ray tube: 0.545 μSv, and 50 cm on the right behind the X-ray tube: 1.466 μSv. Measurements behind the radiation barrier were 0.190 μSv, 0.204 μSv, and 0.191 μSv. As a result of performing the corresponding sample t test of the average value according to the use of movable barrier walls, p <0.001 was found. As a result of the actual measurement, the medical exposure of the examiner due to the shielding wall in the laboratory decreased to 82.3%. In order to reduce occupational exposure in screening radiological laboratories, it is recommended that sufficient separation from radiation sources and the use of shielding walls are recommended.

Influences on Radiation Safety Management Practice of General Characteristics and Radiation Safety Management Practice for Dental Hygienists in Busan and Gyeongnam Province (부산.경남 일부지역 치과위생사들의 일반적 특성과 방사선 안전관리 특성이 방사선 안전관리 실천에 미치는 영향)

  • Seong, Mi-Kyung;Jang, Kyeung-Ae
    • Journal of dental hygiene science
    • /
    • v.13 no.3
    • /
    • pp.264-270
    • /
    • 2013
  • This research, which was conducted for dental hygienists, intended to check out what factors have an influence on their practices by knowledge and attitude on radiation safety management (RSM). This study performed a survey on such an issue from July 2 to August 30, 2012 for 220 dental hygienists who worked in Busan, Gyeongnam areas. The data was analysed using the IBM SPSS Statistics 21.0 program. The results were as follows: As a result of the knowledge according to the general characteristics and RSM, a statistically meaningful difference was found according to the education on radiation and wearing apron. As for the attitude according to the general characteristics and RSM, a statistically meaningful difference was found according to the education on radiation and wearing apron. As to the practice according to the general characteristics and RSM, a statistically meaningful difference was found according to the education on radiation, wearing thermo luminescent dosimeter and wearing apron. When the analysis of safety management practice for radiation was conducted with the independent variables such as knowledge, altitude and health concerns about radiography, it turned out that the factors having an effect on the practice were altitude and health concerns by that order.

Validation of Net Radiation Measured from Fluxtower Based on Eddy Covariance Method: Case Study in Seolmacheon and Cheongmicheon Watersheds (에디공분산 방법 기반의 플럭스 타워 순 복사에너지 검증: 설마천, 청미천 유역)

  • Byun, Kyuhyun;Shin, Jiyae;Lee, Yeon-Kil;Choi, Minha
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.2
    • /
    • pp.111-122
    • /
    • 2013
  • The necessity of clear understanding of water and energy cycles has been attracted recently due to the climate change. The micrometeorological flux tower networks play a role of cornerstone of the hydrological and ecological analyses. Although the eddy covariance techniques used for flux tower have been proven to be applicable for estimation of latent heat flux, the raw data are often underestimated and needs to be corrected. Among several methods, the Bowen ratio is recognized as the most useful method in which the net radiation and other flux data (Ground heat flux, Sensible heat flux) are used and needed to be validated. In this study, in order to validate the net radiation from flux tower in Seolmacheon and Cheongmicheon watersheds, we compare it with two version of calculated net radiation: (1) FAO 56 Daily net radiation proposed by Allen et al. (1998). (2) Instantaneous net radiation proposed by Bastiaanssen (1995). The results showed that the net radiation from the flux data had similar tendency with those calculated based on physical theory. In addition, after it was applied to Bowen ratio method, the corrected latent heat flux was considerably improved with making the energy balance much more closed.

KOREAN VLBI NETWORK CALIBRATOR SURVEY (KVNCS): 1. SINGLE DISH FLUX MEASUREMENT IN THE K AND Q BANDS

  • Lee, Jeong Ae;Sohn, Bong Won;Jung, Taehyun;Byun, Do-Young;Lee, Jee Won
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.41 no.2
    • /
    • pp.32.2-32.2
    • /
    • 2016
  • We present the catalog of the KVN Calibrator Survey (KVNCS). This first part of the KVNCS is a single dish radio survey conducted at 22 (K band) and 43 GHz (Q band) simultaneously using the Korean VLBI Network (KVN) from 2009 to 2011. A total 2045 sources selected from the VLBA Calibrator Survey (VCS) with an extrapolated flux limit of 100 mJy at K band. The KVNCS contains 1533 sources in the K band with a flux limit of 70 mJy and 553 sources in the Q band with a flux limit of 120 mJy; it covers the whole sky down to -32. ${\circ}$ 5 in declination. Five hundred thirteen sources were detected in the K and Q bands, simultaneously; ~76% of them are flat-spectrum sources ($-0.5{\leq}{\alpha}{\leq}0.5$). From the flux-flux relationship, we anticipated that the most of the radiation of many of the sources comes from the compact components. Therefore, the sources listed in the KVNCS are strong candidates for high frequency VLBI calibrators.

  • PDF

A Survey on Korean Medicine Doctors' Recognition for Developing Korean Medicine Clinical Practice Guidelines for Gastric Cancer (위암 한의표준임상진료지침 개발을 위한 한의사 인식조사)

  • Dong-hyeon Kim;Jong-hee Kim;Ji-hye Park;Hwa-seung Yoo;So-jung Park
    • The Journal of Internal Korean Medicine
    • /
    • v.44 no.3
    • /
    • pp.466-484
    • /
    • 2023
  • Objective: The purpose of this study was to provide data for the development of Korean medicine (KM) clinical practice guidelines (CPG) for gastric cancer (GC) by identifying the awareness and knowledge needs of KM doctors (KMD) through an online survey. Methods: A survey questionnaire was produced by referring to the previous recognition survey studies for clinical KMDs. The survey questionnaire was composed of questions regarding the current status of clinical care for GC, the knowledge level of clinicians about GC, and other details that clinicians use during practice. The survey was conducted from September 20 to October 22, 2021. An online survey was conducted with 195 KMDs from the Society of Korean Medicine and the Korean Association of Traditional Oncology of KM. Results: A total of 195 respondents participated in the online survey regarding the current status of GC treatment. Of this number, 10.3% of the respondents specialize in GC, but even if they do not currently specialize in GC, they are more likely to treat patients with GC in the future. In terms of the specifics of KM treatment, there was a demand for information on comprehensive KM treatment methods, such as herbal medicine, acupuncture, moxibustion, cupping, and chuna, as well as on analyzing the effectiveness of combined treatment with chemotherapy and radiation. Conclusion: In this study, we were able to understand the clinical KMDs' perception of GC, knowledge level, and requirements in the CPG. The results of this study will provide the basic data for the development of CPG for GC.

Nationwise Survey of the X-ray Beam Collimator Utilization in General Diagnostic Radiograph (진단방사선 일반촬영에서의 X-ray Beam Collimator 사용 전국 실태조사)

  • Kim, Jee Hye;Sung, Dong-Wook;Kim, Jeong Wook;Shin, Jin Ho;Lee, Soon Keun;Jung, Kyung Il;Uhm, Jong Kwan;Lee, Ki Nam;Seong, Ho Jin;Kim, Youn Hyun;Kim, Hyeog Ju
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.119-126
    • /
    • 2013
  • Due to the introduction of CR and DR, it has been neglected the use of the X-ray beam collimator and field size. This study examines nationwide survey of the proper use of collimator and field size by area in a specific field of plain radiography and the current status. Authors emphasized the need for the field size criteria, and propose a standard reference field size in each specific radiologic examination. Total 333 medical institutions (included in Seoul, Gyeonggi-do, Jeolla, Chungcheong, Gangwon-do, Busan area), were investigated in relation to the status of the X-ray beam collimation field size, type specific inspection areas, medical facilities, and image analyses by type to figure out whether they use the adjustment of image field to the specific examination. To assess the awareness and the impact of radiation exposure to the collimation adjustable, 168 radiographers who was working in 10 general hospitals, 10 hospitals, and 10 clinics, were surveyed how they haver adjusted the actual field size. We examine that 61.3% of medical institutions used the "Proper collimation" and only 49.9% of them employed proper one in lumbar spine densely crowded by major organs. 69% among general hospitals, and 65% among hospitals using DR system were using proper collimation. Radiographers recognized that proper adjustment of collimation could reduce the harmful radiation dose on patients. In the survey, 97.6% of respondents were aware of this fact, but only 83.3% of respondents did the adjustment of the size of the collimation field. The using of proper collimation field was low in the nationwide survey, so the effort to reduce the radiation dose on the patients is urgently needed. A unified standard for the field accompanied by thorough education should be needed.

A Study on Radiation Safety Management by Dental Hygienist (치과위생사의 방사선 안전관리에 대한 조사 연구)

  • Kang, Eun-Ju;Lee, Kyung-Hee;Kim, Young-Im
    • Journal of dental hygiene science
    • /
    • v.5 no.3
    • /
    • pp.105-112
    • /
    • 2005
  • In spite of relatively low level of radiation dose used at dental clinics, long term exposure may be harmful, so radiation workers at dental clinics must be well aware of its danger. This study was to analyze the factors to have an influence on safety management behavior in the radiography chamber by understanding the relationship among the knowledge, attitudes and behavior in regard with radiation safety management by dental hygienists in order to take preventive measures for dental hygienists and suggest ideas to develop radiation safety training programs. For this, we contacted dental hygienists working at the local dental clinics for 4 months from December of 2003 to march of 2004 and obtained the following findings. 1. Concering the knowledge level of radiation safety management, $8.59{\pm}2.36$ was average score with the highest of 13 and the lowest of 3 from 15-scale test. In addition, knowledge level of radiation safety management by general characteristics showed statistically significant difference according to working experience (p < 0.001), marital status (p < 0.001), attendance rate of radiation safety management training program (p < 0.001), and type of clinic (p < 0.001). 2. Concering the attitude level of radiation safety management, $4.08{\pm}0.50$ is average score with the highest of $4.31{\pm}0.73$ and the lowest of $3.82{\pm}0.89$ by item from 5-scale test. Besides, attitude level of radiation safety management by general characteristics showed statistically significant difference according to age (p < 0.001), working experience (p < 0.05), attendance rate of radiation safety management training program (p < 0.01), and type of clinic (p < 0.001). 3. Concering the behavior level of radiation safety management, $2.89{\pm}0.77$ is average score from 5-scale test, which was relatively low in comparison with the level of attitude and the highest score was $3.82{\pm}0.94$ and the lowest $2.37{\pm}1.04$ by item. Behavior level of radiation safety management by general characteristics showed statistically significant difference according to working experience (p < 0.001) and type of clinic (p < 0.001). 4. From the survey of relationship among knowledge, attitude and behavior of radiation safety management was, we found that the higher the knowledge level of radiation safety management, the higher the level of attitude and behavior, and the higher the attitude level was, the higher the level of behavior.

  • PDF

Relationship between Knowledge, Attitude, Behavior, and Self-Efficacy on the Radiation Safety Management of Radiation Workers in Medical Institutions (의료기관 방사선종사자의 방사선안전관리에 대한 지식, 태도 및 행위와 자기효능감 간의 관련성)

  • Han, Eun-Ok
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.2
    • /
    • pp.89-96
    • /
    • 2007
  • Radiation safety managements in medical institutions are needed to protect certain radiation damages as a part of National Coalition. This study investigates the characteristics of self-efficacy that become the major factor on the knowledge, attitude, and behavior on the radiation safety management of radiation workers as an approach of educational aspects and analyzes the relationship between such factors to provide basic materials for improving the activity level of radiation safety managements. In order to implement the goal or this study, a survey was performed for 1,200 workers who were engaged in radiation treatments in medical centers, such as general hospital, university hospital, private hospital, and public health center for 42 days from July 23,2006. Then, the results of the analysis can be summarized as follows: 1. Average scores on knowledge, attitude, and behavior in the radiation safety management were presented as $75.76{\pm}11.20$, $90.55{\pm}8.59$, $80.58{\pm}11.70$, respectively. Also, the average score of self-efficacy was recorded as $73.55{\pm}9.82$. 2. Knowledge levels in the radiation safety management showed significant differences according to the sex, age, marriage, education, and experience. Also, males of married, older, highly educated, and largely experienced represented high knowledge levels. Attitude levels in the radiation safety management showed certain significant differences according to the type of medical centers in which private hospitals showed a relatively low level compared to that of high levels in university hospitals. Behavior levels in the radiation safety management also represented significant differences according to the age, marriage, education, experience, and types of medical centers. Factors in married, general hospital, older, highly educated, and largely experienced showed high behavior levels. In addition, the self-efficacy showed certain differences according to the marriage and types of medical centers. Factors in married and general hospital demonstrated high self-efficacy levels. 3. Relationship between knowledge, attitude, behavior, and self-efficacy on the radiation safety management showed statistical differences according to the relationship between the knowledge and the attitude, the knowledge and the behavior, the attitude and the behavior, the attitude and the self-efficacy, and the behavior and the self-efficacy. The relationship between the behavior and the self-efficacy was represented as r = 0.482, which was the strongest relationship in such factors. Also, the knowledge and self-efficacy didn't show certain relationships.