• Title/Summary/Keyword: Radiation stability

Search Result 388, Processing Time 0.029 seconds

Sinusoidal A Study on the gain Stability of the Feedback Linear Pulse Amplifiers for Fast Pulse Input (금속펄스 선형증폭기의 빠른 입력펄스에 대한 이득안정도에 관한 연구)

  • 이병선
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.11 no.3
    • /
    • pp.1-14
    • /
    • 1974
  • The gain stability of the nuclear pulse linear amplifiers with feedback for such a fast pulse input as the step voltage or the nuclear radiation detector pulse is analysed in detail. The expression is derived which describes the waveform at the anode circuit of the photomultiplier tube which is a part of the nuclear radiation detector. It is analysed and compared when the feedback amplifier has one and two time-constants. When these fast input pulse voltages are applied to the feedback amplifier, the effects of feedback in linearity and stability of the output voltage appear only after two or three rise-times of the amplifier, And it is proved that in order to reduce this limitation, the rise time of the feedback amplifier shou1d be less than the input pulse width. It is also shown that the above theory can be applied directly to the voltage-shunt feedback amplifier stages designed as the basic amplifier of the linear amplifier, and that the gain stability is more improved for the smaller input impedance of this amplifier stage.

  • PDF

Large-volume and room-temperature gamma spectrometer for environmental radiation monitoring

  • Coulon, Romain;Dumazert, Jonathan;Tith, Tola;Rohee, Emmanuel;Boudergui, Karim
    • Nuclear Engineering and Technology
    • /
    • v.49 no.7
    • /
    • pp.1489-1494
    • /
    • 2017
  • The use of a room-temperature gamma spectrometer is an issue in environmental radiation monitoring. To monitor radionuclides released around a nuclear power plant, suitable instruments giving fast and reliable information are required. High-pressure xenon (HPXe) chambers have range of resolution and efficiency equivalent to those of other medium resolution detectors such as those using NaI(Tl), CdZnTe, and $LaBr_3:Ce$. An HPXe chamber could be a cost-effective alternative, assuming temperature stability and reliability. The CEA LIST actively studied and developed HPXe-based technology applied for environmental monitoring. Xenon purification and conditioning was performed. The design of a 4-L HPXe detector was performed to minimize the detector capacitance and the required power supply. Simulations were done with the MCNPX2.7 particle transport code to estimate the intrinsic efficiency of the HPXe detector. A behavioral study dealing with ballistic deficits and electronic noise will be utilized to provide perspective for further analysis.

Evaluation of the Long-Term Stability for the Cylindrical Ionization Chambers (교정정수 변화에 의한 원통형이온함의 안정성 평가)

  • Rah Jeong-Eun;Hong Ju-Young;Kim Gwe-Ya;Lim Chun-Il;Jeong Hee-Kyo;Shin Dong-Oh;Suh Tea-Suk
    • Radiation Oncology Journal
    • /
    • v.24 no.2
    • /
    • pp.138-143
    • /
    • 2006
  • Purpose: To analyze the long-term stability of Farmer-type cylindrical ionization chambers by calibration factor provided from the KFDA (Korea Food Drug Administration) Materials and Methods: The cylindrical ionization chambers used in this study were the PTW 30001 (30006), 30013, 30002, 30004, 23333, the Capintec PR06C, the WE 2571, the Exradin A12 and the Wellhofer FC65G (IC70). We were analyzed that the $N_k$ and $N_{D.W}$ calibration factor for the cylindrical chambers and compared between the measured $N_{D.W}$ and calculated $N_{D.W}$ calibration factor. Results: We have observed that the long-term stability of the PTW 30013 (30006), the Wellhofer FC65G (IC70) and the NE 2571 has varied within 0.2%. The measured $N_{D,W}$ calibration factor was about 1.0% higher than the calculated $N_{D,W}$ that determined by the $N_k$ calibration factor. Conclusion: The study has evaluated that the long-term stability of the cylindrical chambers through analysis for the $N_k\;and\;N_{D,W}$ calibration factor. It has contributed to the improvement of clinical electron dosimetry in radiotherapy centers.

Study of the Changes in Wood Properties by Gamma Irradiation (감마선 조사에 의한 목재성질 변화에 관한 연구)

  • Yoon, Min-Chul;Park, Byung-Soo;Kim, Ik-Joo;Choi, Jong-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.40 no.4
    • /
    • pp.229-236
    • /
    • 2012
  • This study was conducted to investigate the effect of gamma radiation on cell wall degradation, cellulose crystallinity, and flexural strength of Pinus densiflrora, Zelkova serrenata, and Paulownia tomentosa. By the gamma radiation at the dose up to 100 kGy, the cell wall degradation was not detected with scanning electron microscope (SEM) observation from all samples, and the flexural strength was not significantly changed. Cellulose crystallinity was neither changed by the gamma radiation. This high stability of wood against gamma radiation means that the radiation technology can be used for eradicating fungal and insect infestation of wood without the changes in wood properties.

Radiation attenuation and elemental composition of locally available ceramic tiles as potential radiation shielding materials for diagnostic X-ray rooms

  • Mohd Aizuddin Zakaria;Mohammad Khairul Azhar Abdul Razab;Mohd Zulfadli Adenan;Muhammad Zabidi Ahmad;Suffian Mohamad Tajudin;Damilola Oluwafemi Samson;Mohd Zahri Abdul Aziz
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.301-308
    • /
    • 2024
  • Ceramic materials are being explored as alternatives to toxic lead sheets for radiation shielding due to their favorable properties like durability, thermal stability, and aesthetic appeal. However, crafting effective ceramics for radiation shielding entails complex processes, raising production costs. To investigate local viability, this study evaluated Malaysian ceramic tiles for shielding in diagnostic X-ray rooms. Different ceramics in terms of density and thickness were selected from local manufacturers. Energy Dispersive X-ray Fluorescence (EDXRF) and X-ray Fluorescence (XRF) characterized ceramic compositions, while Monte Carlo Particle and Heavy Ion Transport code System (MC PHITS) simulations determined Linear Attenuation Coefficient (LAC), Half-value Layer (HVL), Mass Attenuation Coefficient (MAC), and Mean Free Path (MFP) within the 40-150 kV energy range. Comparative analysis between MC PHITS simulations and real setups was conducted. The C3-S9 ceramic sample, known for homogeneous full-color structure, showcased superior shielding attributes, attributed to its high density and iron content. Notably, energy levels considerably impacted radiation penetration. Overall, C3-S9 demonstrated strong shielding performance, underlining Malaysia's potential ceramic tile resources for X-ray room radiation shielding.

Sensory Evaluation of Korean Seaweed Soup, Miyukgook, with Gamma-irradiated Undaria pinnatifida (감마선 조사된 미역으로 제조한 미역국의 관능 연구)

  • Choi, Jong-il;Kim, Jae-Hun;Song, Beom-Seok;Kim, Jaekyung;Lee, Ju-Woon;Chun, Byung-Soo;Ahn, Dong-Hyun;Byun, Myung-Woo;Park, Kyung-Sook
    • Journal of Radiation Industry
    • /
    • v.5 no.1
    • /
    • pp.21-24
    • /
    • 2011
  • This study was conducted to evaluated the sensory properties of Miyukgook, Korean seaweed soup, with gamma-irradiated Undaria pinnadifida for enhancing the storage of the harvested seaweed. The harvested seaweed was irradiated at the doses of 1, 3, 5, and 10 kGy. The Miyukgook was made by following the general recipe. The values of pH and acidity of the Miyukgook were not changed by the irradiation of harvested Undaria. The sensory evaluation result showed that the preference scores in all the sensory properties was a little decreased when it was irradiated, but sensory score of less than 5 kGy samples was similar in all terms. Therefore, it was considered that gamma irradiation with less than 5 kGy was effective for improvement of the storage stability of U. pinnatifida without the changes in the sensory of its major cooked food, Miyukgook.

A Study on the Preparation and Hydrophilization of Polypropylene Microfiltration Membrane by Radiation-Induced Graft Polymerization (방사선 중합에 의한 폴리프로필렌 정밀여과막의 제조 및 친수화 거동에 관한 연구)

  • 황택성;이선아;황의환
    • Polymer(Korea)
    • /
    • v.24 no.5
    • /
    • pp.621-628
    • /
    • 2000
  • Microporous polypropylene (PP) membranes have the high chemical and corrosion resistance, the good mechanical properties and the thermal stability under high temperatures, but its application is restricted within narrow limits due to hydrophobicity of membranes. In order to impart permanent hydrophilicity to the PP microfiltration membrane, the radiation-induced graft of 2-hydroxyethyl methacrylate (HEMA) and acrylic acid (AAc) containing hydrophilic functional group onto the membrane has been studied. The effect of graft conditions such as reaction time, total radiation dose, reaction temperatures, acid compositions on graft yield was investigated. Modified PP membranes were shown to cause an increase in the gas flux. Oil emulsion permeation flux of both original PP membrane and modified PP membrane was examined.

  • PDF

Preparation of a Nanosized Micro Element Fertilizer Formulation by using Gamma-irradiation Technique (감마선 조사기술을 이용한 미량원소 비료 나노제제 제조)

  • Park, Hae-Jun;Kim, Hwa-Jung
    • Journal of Radiation Industry
    • /
    • v.4 no.4
    • /
    • pp.347-352
    • /
    • 2010
  • In this study, we addressed a novel nanosized curdlan-silica complex, which is curdlan bound to silica, for the development of a sustain-releasing micro element fertilizer formulation. The complex was obtained as follow steps; First, Curdlan polymer, sodium silicate ($Na_2SiO_3$) and isopropyl alcohol were dissolved in DDW. Next the resultant solution was irradiated by $^{60}Co$ gamma-irradiator (150 TBq of capacity; ACEL, Canada). Then $MgSO_4$ was treated with the resultant solution. The obtained colloidal solution was dried by freeze dryer. Finally, we obtained a novel nanosized curdlan-silica formulation containing $MgSO_4$ from the colloidal solution. The morphology of the complex was characterized by using scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The nanosized curdlan-silica complex has a particle size ranging from 20 to 80 nm and high stability. Our results suggested that the nano-complex can be applicable to use in various sustain-releasing formulation for pesticide delivery system (PDS).

Discharge header design inside a reactor pool for flow stability in a research reactor

  • Yoon, Hyungi;Choi, Yongseok;Seo, Kyoungwoo;Kim, Seonghoon
    • Nuclear Engineering and Technology
    • /
    • v.52 no.10
    • /
    • pp.2204-2220
    • /
    • 2020
  • An open-pool type research reactor is designed and operated considering the accessibility around the pool top area to enhance the reactor utilization. The reactor structure assembly is placed at the bottom of the pool and filled with water as a primary coolant for the core cooling and radiation shielding. Most radioactive materials are generated from the fuel assemblies in the reactor core and circulated with the primary coolant. If the primary coolant goes up to the pool surface, the radiation level increases around the working area near the top of the pool. Hence, the hot water layer is designed and formed at the upper part of the pool to suppress the rising of the primary coolant to the pool surface. The temperature gradient is established from the hot water layer to the primary coolant. As this temperature gradient suppresses the circulation of the primary coolant at the upper region of the pool, the radioactive primary coolant rising up directly to the pool surface is minimized. Water mixing between these layers is reduced because the hot water layer is formed above the primary coolant with a higher temperature. The radiation level above the pool surface area is maintained as low as reasonably achievable since the radioactive materials in the primary coolant are trapped under the hot water layer. The key to maintaining the stable hot water layer and keeping the radiation level low on the pool surface is to have a stable flow of the primary coolant. In the research reactor with a downward core flow, the primary coolant is dumped into the reactor pool and goes to the reactor core through the flow guide structure. Flow fields of the primary coolant at the lower region of the reactor pool are largely affected by the dumped primary coolant. Simple, circular, and duct type discharge headers are designed to control the flow fields and make the primary coolant flow stable in the reactor pool. In this research, flow fields of the primary coolant and hot water layer are numerically simulated in the reactor pool. The heat transfer rate, temperature, and velocity fields are taken into consideration to determine the formation of the stable hot water layer and primary coolant flow. The bulk Richardson number is used to evaluate the stability of the flow field. A duct type discharge header is finally chosen to dump the primary coolant into the reactor pool. The bulk Richardson number should be higher than 2.7 and the temperature of the hot water layer should be 1 ℃ higher than the temperature of the primary coolant to maintain the stability of the stratified thermal layer.