• Title/Summary/Keyword: Radiation spectrum

Search Result 509, Processing Time 0.027 seconds

Investigation of Response of Several Neutron Surveymeters by a DT Neutron Generator (DT 중성자 발생기에 의한 중성자 검출기 반응도 조사)

  • Kim, Sang-In;Jang, In-Su;Kim, Jang-Lyul;Lee, Jung-Il;Kim, Bong-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.1
    • /
    • pp.35-40
    • /
    • 2012
  • Several neutron measuring devices were tested under the neutron fields characterized with two distinct kinds of thermal and fast neutron spectrum. These neutron fields were constructed by the mixing of both thermal neutron fields and fast neutron fields. The thermal neutron field was constructed using by a graphite pile with eight AmBe neutron sources. The fast neutron field of 14 MeV was made by a DT neutron generator. In order to change the fraction of fast neutron fluence rate in each neutron fields, a neutron generator was placed in the thermal neutron field at 50 cm and 150 cm from the reference position. The polyethylene neutron collimator was used to make moderated 14 MeV neutron field. These neutron spectra were measured by using a Bonner sphere system with an LiI scintillator, and dosimetric quantities delivered to neutron surveymeters were determined from these measurement results.

Fast Neutron Dosimetry in Nuclear Criticality Accidents (핵임계사고시(核臨界事故時)에 있어서 속중성자선량(速中性子線量) 측정(測定))

  • Yook, Chong-Chul;Ro, Seung-Gy
    • Journal of Radiation Protection and Research
    • /
    • v.2 no.1
    • /
    • pp.17-23
    • /
    • 1977
  • The neutron dosimetrical parameters, i. e., the fission neutron spectrum-averaged cross-sections and the fluence-to-dose conversion factors have been calculated for some threshold detectors with the aid of a computer. The threshold detectors under investigation were the $^{115}In(n,\;n')^{115m}In,\;^{32}S(n,\;p)^{32}P$ and $^{27}Al(n,\;{\alpha})^{24}Na$ reactions. It is revealed that the average cross-sections($\bar{\sigma}$) for the $^{32}S(n,\;p)^{32}P$ reaction are independent of the spectral functions, namely, the Watt-Cranberg and Maxwellian forms. In the case of the $^{27}Al(n,\;{\alpha})^{24}Na$ reaction a variation of the $\bar{\sigma}$ values appears to be highly dependent on the fissioning types. It seems that both the average cross-section for the $^{115}In(n,\;n')^{11m}In$ reaction and the conversion factor are insensitive to the spectral deformation of fission neutrons. These phenomena make it applicable to use indium as a possible integral fast neutron dosimeter in nuclear criticality accidents provided that the virgin fission neutrons are completely free from the scattered neutrons.

  • PDF

Treatment of Extremely High Risk and Resistant Gestational Trophoblastic Neoplasia Patients in King Chulalongkorn Memorial Hospital

  • Oranratanaphan, Shina;Lertkhachonsuk, Ruangsak
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.2
    • /
    • pp.925-928
    • /
    • 2014
  • Background: Gestational trophoblastic neoplasia (GTN) is a spectrum of disease with abnormal trophoblastic proliferation. Treatment is based on FIGO stage and WHO risk factor scores. Patients whose score is 12 or more are considered as at extremely high risk with a high likelihood of resistance to first line treatment. Optimal therapy is therefore controversial. Objective: This study was conducted in order to summarize the regimen used for extremely high risk or resistant GTN patients in our institution the in past 10 years. Materials and Methods: All the charts of GTN patients classified as extremely high risk, recurrent or resistant during 1 January 2002 to 31 December 2011 were reviewed. Criteria for diagnosis of GTN were also assessed to confirm the diagnosis. FIGO stage and WHO risk prognostic score were also re-calculated to ensure the accuracy of the information. Patient characteristics were reviewed in the aspects of age, weight, height, BMI, presenting symptoms, metastatic area, lesions, FIGO stage, WHO risk factor score, serum hCG level, treatment regimen, adjuvant treatments, side effects and response to treatment, including disease free survival. Results: Eight patients meeting the criteria of extremely high risk or resistant GTN were included in this review. Mean age was 33.6 years (SD=13.5, range 17-53). Of the total, 3 were stage III (37.5%) and 5 were stage IV (62.5%). Mean duration from previous pregnancies to GTN was 17.6 months (SD 9.9). Mean serum hCG level was 864,589 mIU/ml (SD 98,151). Presenting symptoms of the patients were various such as hemoptysis, abdominal pain, headache, heavy vaginal bleeding and stroke. The most commonly used first line chemotherapeutic regimen in our institution was the VAC regimen which was given to 4 of 8 patients in this study. The most common second line chemotherapy was EMACO. Adjuvant radiation was given to most of the patients who had brain metastasis. Most of the patients have to delay chemotherapy for 1-2 weeks due to grade 2-3 leukopenia and require G-CSF to rescue from neutropenia. Five form 8 patients were still survived. Mean of disease free survival was 20.4 months. Two patients died of the disease, while another one patient died from sepsis of pressure sore wound. None of surviving patients developed recurrence of disease after complete treatment. Conclusions: In extremely high risk GTN patients, main treatment is multi-agent chemotherapy. In our institution, we usually use VAC as a first line treatment of high risk GTN, but since resistance is quite common, this may not suitable for extremely high risk GTN patients. The most commonly used second line multi-agent chemotherapy in our institution is EMA-CO. Adjuvant brain radiation was administered to most of the patients with brain metastasis in our institution. The survival rate is comparable to previous reviews. Our treatment demonstrated differences from other institutions but the survival is comparable. The limitation of this review is the number of cases is small due to rarity of the disease. Further trials or multicenter analyses may be considered.

Monte Carlo Simulation of a Varian 21EX Clinac 6 MV Photon Beam Characteristics Using GATE6 (GATE6를 이용한 Varian 21EX Clinac 선형가속기의 6 MV X-선 특성모사)

  • An, Jung-Su;Lee, Chang-Lae;Baek, Cheol-Ha
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.571-575
    • /
    • 2016
  • Monte Carlo simulations are widely used as the most accurate technique for dose calculation in radiation therapy. In this paper, the GATE6(Geant4 Application for Tomographic Emission ver.6) code was employed to calculate the dosimetric performance of the photon beams from a linear accelerator(LINAC). The treatment head of a Varian 21EX Clinac was modeled including the major geometric structures within the beam path such as a target, a primary collimator, a flattening filter, a ion chamber, and jaws. The 6 MV photon spectra were characterized in a standard $10{\times}10cm^2$ field at 100 cm source-to-surface distance(SSD) and subsequent dose estimations were made in a water phantom. The measurements of percentage depth dose and dose profiles were performed with 3D water phantom and the simulated data was compared to measured reference data. The simulated results agreed very well with the measured data. It has been found that the GATE6 code is an effective tool for dose optimization in radiotherapy applications.

Neutron Dose Measurements Using TLDs in a 252Cf Neutron Field (252Cf 중성자장에서 열형광선량계(TLD)를 이용한 중성자 방사선량 측정)

  • Chang, Insu;Kim, Sang In;Lee, Jung Il;Kim, Jang Lyurl;Kim, Bong Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.1
    • /
    • pp.37-43
    • /
    • 2013
  • In case of neutron dose measurement using TLDs (thermo-luminescence dosimeters), because the neutron energy dependence of the TLD is very high, the calibration of the energy response according to the characteristics of the neutron spectrum of workplace is required. In the present study, the ambient dose equivalent rates inside and around the Long-Counter (neutron detector) with narrow and complex inside in the neutron field of $^{252}Cf$ were evaluated. The calibration factors to account for the neutron energy dependence of TLDs were established for both the bare and $D_2O$ modulated $^{252}Cf$ neutron beams, respectively. The values of the TLD's measurement were compared with the computational results of the MCNPX (Monte Carlo N-Particles transport code). When using the two calibration factors of the TLD than a single calibration factor, the measured and the calculated values at the point of verification outside and inside the Long-Counter were in more good agreement. This results show that TLD should be calibrated in the reference neutron field similar to workplace situation.

Electronic Structures of Co-Pd Alloy Films Using Synchrotron Radiation Photoemission Spectroscopy (방사광 광전자 분광법을 이용한 Co-Pd 합금박막의 전자구조 연구)

  • 강정수;권세균;하양장;민병일;조용필;이창섭;정인범;구양모;김건호
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.6
    • /
    • pp.405-410
    • /
    • 1996
  • Valence band photoemission spectroscopy (PES) measurements have been performed for $Co_{x}Pd_{100-x}$ alloy films using synchrotron radiation (x = 0, 25, 40, 65). Then the partial spectral weight distributions (PSW's) of Co 3d and Pd 4d electrons have been determined. The Co 3d PSW's exhibit some structures which are quite different from those of the Co film for x < 25 %, whereas they become very similar to those of the Co film for x > 40 %. For x < 25 %, the peak near the Fermi level ($E_F$) and a shoulder around 2 eV binding energy in the Co 3d PSW reflect large hybridization between Pd 4d and Co 3d electrons, suggesting that the hybridization might play an inportant role in determining perpendicualr magnetic anisotropy. The Pd 4d PSW's in Co-Pd alloy films are found to have larger FWHM's (full widths at half maximum), larger binding energies of the main peaks, and larger spectral intensities at $E_F$ than the PES spectrum of the Pd film. The FWHM of the Pd 4d PSW increases with decreasing Pd concentration, which are considered to reflect the disordering effect in the alloy formation or the change in the Pd 4d electronic structure due to hybridization between Co 3d and Pd 4d electrons.

  • PDF

Assessment of Effective Dose from Diagnostic X-ray Examinations of Adult (진단X선에 의한 성인의 진단행위별 유효선량평가)

  • Kim, Woo-Ran;Lee, Choon-Sik;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.3
    • /
    • pp.155-164
    • /
    • 2002
  • Methodology to evaluate the effective doses to adults undergoing various diagnostic x-ray examinations were established by Monte Carlo simulation of the x-ray examinations. Anthropomorphic mathematical phantoms, the MIRD5 male phantom and the ORNL female phantom, were used as the target body and x-ray spectra were produced by the x-ray spectrum generation code SPEC78. The computational procedure was validated by comparing the resulting doses to the results of NRPB studies for the same diagnostic procedures. The effective doses as well as the organ doses due to chest, abdomen, head and spine examinations were calculated for x-rays incident from AP, PA, LLAT and RLAT directions. For instance, the effective doses from the most common procedures, chest PA and abdomen AP, were 0.029 mSv and 0.44 mSv, respectively. The fact that the effective dose from PA chest x-ray is far lower than the traditional value of 0.3 mSv(or 30 mrem), which results partly from the advances of technology in diagnostic radiology and partly from the differences in the dose concept employed, emphasizes necessities of intensive assessment of the patient doses in wide ranges of medical exposures. The methodology and tools established in this study can easily be applied to dose assessments for other radiology procedures; dose from CT examinations, dose to the fetus due to examinations of pregnant women, dose from pediatric radiology.

Anisotropy and Dose Equivalents Conversion Factors for the Unmoderated $^{252}Cf$ Source (비감속 $^{252}Cf$ 중성자선원에 대한 비등방성교정인자 및 선량당량환산인자)

  • Jeong, Deok-Yeon;Chang, Si-Young;Yoon, Suk-Chul;Kim, Jong-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.18 no.2
    • /
    • pp.71-79
    • /
    • 1993
  • Form the pure Maxwellian distribution(kT= 1.42MeV), the effects upon calibration factors of encapsulating a $^{252}Cf$ spontaneous fission neutron source were investigated to establish a standard neutron field in the Secondary Standard Dosimetry Laboratory at Korea Atomic Energy Research Institute(KAERI). A Monte Carlo code MCNP was used in simulating the encapsulation SR-Cf-100 and SR-Cf-1273 to be real conditions. The anisotropy(FI) and fluence-to-dose equivalents conversion factors$(H/{\Phi})$ were evaluated and compared with other results. As the results, the FI was determined to be 1.061 at ${\theta}=90^{\circ}$ with ${\pm}0.2%$ statistical error and the $(H/{\Phi})$ was evaluated to be $333.9 [pSv\;cm^2]\;with\;{\pm}0.5%$ statistical error, which is lower by 1.8% than that recommended by the ISO 8529. This means physically that the neutron spectrum of the unmoderated $^{252}Cf$ source in KAERI is a little more softened than that by the ISO.

  • PDF

Effects of γ-Irradiation on Antioxidant and Physicochemical Properties of Ishige okamurai Extracts (패 추출물의 항산화능 및 이화학적 특성에 미치는 감마선 조사의 영향)

  • Kim, Mi-Jung;Song, Eu-Jin;Lee, So-Young;Kim, Koth-Bong-Woo-Ri;Kim, Seo-Jin;Lee, So-Jeong;Yoon, So-Young;Kim, Ah-Ram;Jeon, You-Jin;Park, Jin-Gyu;Choi, Jong-Il;Lee, Ju-Woon;Byun, Myung-Woo;Ahn, Dong-Hyun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.11
    • /
    • pp.1485-1490
    • /
    • 2008
  • The effects of $\gamma$-irradiation on antioxidant and physicochemical properties of powder and 70% fermented ethanol extracts of Ishige okamurai (I. okamurai) were investigated. In case of powder, although yields were increased, there were no significant changes in total phenolic compounds (TPC) and 2,2-diphenyl-2-picrylhydrazyl (DPPH) radical scavenging effect by $\gamma$-irradiation at 3, 7, and 20 kGy. In case of 70% fermented ethanol extracts, the results of TPC and DPPH radical scavenging effects showed no significant changes. However, antioxidant index increased in the 20 kGy irradiated I. okamurai extracts and decreased in 3 kGy irradiated ones. The optical density value of UV spectrum at 427 nm significantly decreased depending on increasing irradiation dosage. In conclusion, irradiated extracts of I. okamurai can be applied to the food industry due to irradiation stability on antioxidant properties. Also, irradiated extracts can be more useful for food processing as a result of a decrease of extracts color by irradiation.

Study on the Measurement of Radon concentrations in soil samples using γ-spectrometer (γ-spectrometer를 이용한 토양시료의 라돈농도 측정법에 관한 연구)

  • Kang, Sunga;Lee, Sangsoo;Choi, Guirack;Lee, Junhaeng
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.31-36
    • /
    • 2013
  • The radioactive gas radon ($^{222}Rn$), which is generated from the decay process of uranium ($^{238}U$) originating from the soil of more than 85 percent higher the porosity of the soil, the soil can radiate out the possibility that many isotopes. In order to protect the human body from radon, above all, the development of accurate measurement techniques to formulate appropriate measures should be followed. This study Gamma-ray spectrometry using a high purity germanium (HPGe) detector, if you want to measure radon unstable the nature radiation of the background problems can be reduced, radium and radon daughter nuclides after radioactive equilibrium leads to Radon concentration was measured, the soil samples from the Gamma-ray emitting nuclides, and the energy spectrum is analyzed.