• Title/Summary/Keyword: Radiation spectrum

Search Result 504, Processing Time 0.031 seconds

Surgical Treatment of Bronchial Adenoma - Reports of 17 Cases - (기관지 선종의 외과적 치료[17례 보고])

  • 문석환
    • Journal of Chest Surgery
    • /
    • v.25 no.3
    • /
    • pp.247-257
    • /
    • 1992
  • Bronchial adenoma, firstly described by Muller[1882] had been reported on the subject stressed their benign nature prior to 1940`s, but these tumors including carcinoid tumor, mucoepidermoid carcinoma, adenoid cystic carcinoma, pleomorphic adenoma are now known to possess the various degree of malignant natures from benign course, low grade malignant potential to distant lymphatic or hematogenous metastasis or combination. Although histologically diffeerent, four varieties except carcinoid tumor which is a spectrum of neu-roendocrine tumor originating Kulchitsky cell of the bronchial epithelium and form the part of the APUD tumor spectrum, are morphologically and in many respects clinically similar to the corresponding tumor of the salivary gland is a specific varient of adenocarcinoma that occurs most commonly in the major and minor salivary gland and less frequently tra-cheobronchial tree, esophagus etc. To better understand the clinical characteristics and assess more precisely the malignat nature of bronchial adenoma, we studied 17 cases of bronchial adenoma, which had been experienced at the Department of Thoracic and Cardiovascular surgery of Catholic University Medical College from April 1977 to september 1991. Seventeen cases of bronchial adenoma consist of 2 carcinoid tumors, 6 adenoid cystic carcinomas, 8 mucoepidermoid carcinomas and one pleomorphic adenoma. There is a slight predominace of male patients[10/17] and the age of pt studied varied with a higher incidence occurring between the ages of 40 years and 60 years[mean age, 46.5 years]; the youngest being 15 years and oldest 69 years. Their leading complaints were hemoptysis[4], exertional dyspnea[8], fever & chilness [4], and symptoms mimicking the bronchial asthma[4]. Diagnosis was aided by the radiologic studies such as chest X-ray, polytomography, CT scan, brochography and bronchoscopy. The preferred locations of fumor were in the trachea[4], main stem bronchus[3], bronchus intermedius[3], bronchus of RUL[2], LUL[1], RLL[1], LLL[3] with no peripheral location. Modalities of treatments were single or combination of surgical resection, radiation therapy, chemotherapy. Complete resections were permitted in 12 cases with late recurrences of 4 cases ranging from 6 months to 10 years: pneumonectomy[4], lobectomy[4], bil-obectomy[2], sleeve resection[2]. Gross findings of resected specimens in 14 cases showed that 4 cases were polyp-like pedunculated mass[entirely intraluminal mass] with intact mucosa, 8 cases were broad-bas-ed sessile mass[predominatly intraluminal] and the main portions were located below the mucosa similar to tip of iceburg[predominantly extraluminal] in 2 cases. Follow-up information was availble in all 17 cases ; eight were alive without evidence of disese ranging from 1 month to 13 years. But seven cases died of the causes related to tumor[6 cases within 12 months, one case 10 years after pneumonectomy]. We concluded that 8 cases[47%] of 17 cases were metastasizing bronchial adenoma and precise survival rate cannot be answered by the scanty materials available for study.

  • PDF

Study on the 6 MV Photon Beam Characteristics and Analysis Method from Medical Linear Accelerators Using Geant4 Medical Linac2 Example (GEANT4 Medical Linac2 예제를 이용한 6 MV 선형가속기 광자선속의 기초특성과 연구방법)

  • Kim, Byung-Yong;Kim, Hyung-Dong;Kim, Sung-Jin;Oh, Se-An;Kang, Jung-Gu;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.79-84
    • /
    • 2011
  • In this study, Geant4 based Monte Carlo simulations were carried out for medical linear accelerator. Modified Medical Linac2 toolkit was used for calculation. The energy spectrum, most probable energy and the photon mean energy compared with the published results using the EGS4 code. The results well agreed with published results. The calculated results of photon fluence, energy fluence and mean energy according to the radius from the centre of the beam were analyzed. Monte Carlo simulation using Medical Linac2 code is considered to be useful for analysis of medical linear accelerator. Because the calculated results varies depending on Physics List model for same head structure. It it important to choose the right model for research purpose. Monte Carlo simulation using GEANT4 Medical Linac2 is a valuable for any novice to adopt this code to the study related to 6 MV photon fluence from medical linear accelerator.

Green Light-Emitting Phosphor, Ba2xCaMgSi2O8:Eux

  • Kim, Jeong-Seog;Piao, Ji-Zhe;Choi, Jin-Ho;Cheon, Chae-Il;Park, Joo-Suk
    • Journal of the Korean Ceramic Society
    • /
    • v.42 no.3 s.274
    • /
    • pp.145-149
    • /
    • 2005
  • [ $Eu^{2+}$ ]-activated barium magnesium silicate phosphor, $(Ba,Ca)_{3}MgSi_{2}O_{8}:Eu_{x}$, has been known to emit blue-green light. In this study we report the manufacturing processes for producing either pure green or pure blue light-emitting phosphor from the same composition of $Ba_{2-x}Ca_{2}CaMgSi_{2}O_{8}:Eu_{x}$ (0 < x < 1) by controlling heat treatment conditions. Green light emitting phosphor of $Ba_{1.9}CaMgSi_{2}O_{8}:Eu_{0.1}$ can be produced under the sample preparation condition of highly reducing atmosphere of $23\%\;H_2/77\%\;N_2$, while blue or blue-green light emitting phosphor under reducing atmosphere of $5\~20\%\;H_2\;/\;95\~80\%$ N_2. The green light-emitting phosphors are prepared in two steps: firing at $800\~1000^{\circ}C$ for $2\~5$ h in air then at $1100\~1350^{\circ}C$ for 2-5 h under reducing atmo­sphere $23\%$ $H_2/77\%\;N_2$. The excitation spectrum of the green light-emitting phosphor shows a broadband of $300\~410$ nm. The emission spectrum has a maximum intensity at the wavelength of about 501 nm. The CIE value of green light emission is (0.162, 0.528). The pure blue light-emitting phosphors can be produced using the $Ba{2_x}CaMgSi_{2}O_{8}:Eu_{x}$ by introducing additional firing step at $1150\~1300^{\circ}C$ in air before the final reducing treatment. The XRD analysis shows that the green light-emitting phosphor mainly consisted of $Ba_{1.31}Ca_{0.69}SiO_{4}$ (JCPDS $\#$ 36-1449) and other minor phases i.e., $MgSiO_3$ (JCPDS $\#$ 22-0714) and $Ca_{2}BaMgSi_{2}O_{8}$ (JCPDS $\#$ 31-0128). The blue light-emitting phosphor mainly consisted of $Ca_{2}BaMgSi_{2}O_{8}$ phase.

Observation of the Cosmic Near-Infrared Background with the CIBER rocket

  • Kim, Min-Gyu;Matsumoto, T.;Lee, Hyung-Mok;Arai, T.;Battle, J.;Bock, J.;Brown, S.;Cooray, A.;Hristov, V.;Keating, B.;Korngut, P.;Lee, Dae-Hee;Levenson, L.R.;Lykke, K.;Mason, P.;Matsuura, S.;Nam, U.W.;Renbarger, T.;Smith, A.;Sullivan, I.;Wada, T.;Zemcov, M.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.1
    • /
    • pp.42-42
    • /
    • 2012
  • The First stars (Pop.III stars) in the universe are expected to be formed between the recombination era at z - 1100 and the most distant quasar (z - 8). They have never been directly detected due to its faintness so far, but can be observed as a background radiation at around 1${\mu}m$ which is called the Cosmic Near-Infrared Background (CNB). Main part of the CNB is thought to be redshifted Lyman-alpha from gas clouds surrounding the Pop.III stars. Until now, the COBE (COsmic Background Explorer) and the IRTS (Infrared Telescope in Space) observed excess emission over the background due to galaxies. To confirm the COBE and the IRTS results and pursue more observational evidences, we carried out the sounding rocket experiment named the Cosmic Infrared Background ExpeRiment (CIBER). The CIBER is successfully launched on July 10, 2010 at White Sands Missile Range, New Mexico, USA. It consists of three kinds of instruments. We report the results obtained by LRS (Low Resolution Spectrometer) which is developed to fill the uncovered spectrum around 1${\mu}m$. LRS is a refractive telescope of 5.5 cm aperture with spectral resolution of 20 - 30 and wavelength coverage of 0.7 to 2.0${\mu}m$. After subtracting foreground components (zodiacal light, integrated star light and diffuse galactic light) from the sky brightness of observed five fields, there remained significant residual emission (even for the lower limit case) consistent with the IRTS and the COBE results. In addition, there exists a clear gap at 0.7 - 0.8${\mu}m$ in the CNB spectrum over the background due to galaxies according to recent results (Matsuoka et al. 2011; Mattila et al. 2011). The origin of the excess emission could be ascribed to the Pop.III stars with its active era of z = 7 - 10.

  • PDF

The Development of Water Quality Monitoring System and its Application Using Satellite Image Data

  • Jang, Dong-Ho;Jo, Gi-Ho
    • Proceedings of the KSRS Conference
    • /
    • 1998.09a
    • /
    • pp.376-381
    • /
    • 1998
  • In this study, we was measured the radiance reflectance by using multi-spectral image of low resolution camera(LRC) which will be loaded in the multi-purpose satellite(KOMPSAT) to use the data in analyzing water pollution. Also we investigated the possibility of extraction of water quality factors in rivers and water body by using high resolution remote sensing data such as Airborne MSS. Especially, we tried to extract the environmental factors related with eutrophication, and also tried to develop the process technique and the radiance feature of reflectance related with eutrophication. The results were summarized as follows: First, the spectrum of sun's rays which reaches the surface of the earth was consistent with visible rays bands of 0.4${\mu}{\textrm}{m}$~0.7${\mu}{\textrm}{m}$ and about 50% of total quantity of radiation were there. And at around 0.5${\mu}{\textrm}{m}$ of green spectral band in visible rays bands, the spectrum was highest. Second, as a result of the radiance reflectance Chlorophyll-a represented high spectral reflectance mainly around 0.52${\mu}{\textrm}{m}$ of green spectral band, and suspended sediments and turbidity represented high spectral reflectance at 0.8${\mu}{\textrm}{m}$ and at 0.57${\mu}{\textrm}{m}$ each. Third, as a result of the water quality analysis by using Airborne MSS, Chlorophyll-a could have a distribution chart when carried out ratio of B3 and BS to B7. And Band 7 was useful for making the distribution chart of suspended sediments. And when we carried out PCA, suspended sediments and turbidity had distributions at PC 1 , PC 4 each similarly to ground truth data. Above results can be changed according to the change of season and time. Therefore, in order to analyze more exactly the environmental factors of water quality by using LRC data, we need to investigate constantly the ground truth data and the radiance feature of reflectance of water body. Afterward in this study, we will constantly analyze the radiance feature of the surface of water in water body by measuring the on-the-spot radiance reflectance and using low resolution satellite image(SeaWiFs). Besides, we will gather the data of water quality analysis in water body and analyze the pattern of water pollution.

  • PDF

A Study on the Reduction of Absorbed Dose through the Insertion of a Shielding Material in the Intraoralsensor of Dental Radiography (치과 방사선촬영 시 구내 센서 내 차폐체 삽입을 통한 피폭선량 감소 연구)

  • Kim, A Yeon;Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.273-279
    • /
    • 2022
  • In order to reduce the absorbed dose given to the patient during dental radiography, a sensor that inserts a shield into the intraoralsensor was designed. Using the designed sensor, the change in absorbed dose depending on whether or not a shield was used was evaluated. The system used to evaluate the absorbed dose is VEX-S300C from Vatech, and the energy spectrum of X-rays was obtained through SPEKTR simulation based on the irradiation conditions of 65 kV, 3 mA, and 0.15 sec, and the number of photons for each energy was derived. After designing the system through Genat4 Application for Tomographic Emission(GATE) simulation, the energy spectrum obtained was used as a radiation source to calculate the absorbed dose. Lead was used for the shield, and simulations were performed at 0.1 mm thickness intervals from 0.1 mm to 0.5 mm was evaluated. In the case of using an X-ray field with a diameter of 60 mm, the decrease in absorbed dose according to the presence or absence of a shield decreased exponentially as the thickness of the shield increased. In addition, when a 20 mm × 30 mm field was used, the absorbed dose was significantly reduced even when no shield was used, and it was confirmed that the absorbed dose was further reduced when a shield was used.

Machine Learning-based Atmospheric Correction for Sentinel-2 Images Using 6SV2.1 and GK2A AOD (6SV2.1과 GK2A AOD를 이용한 기계학습 기반의 Sentinel-2 영상 대기보정)

  • Seoyeon Kim;Youjeong Youn;Jonggu Kang;Yemin Jeong;Soyeon Choi;Yungyo Im;Youngmin Seo;Chan-Won Park;Kyung-Do Lee;Sang-Il Na;Ho-Yong Ahn;Jae-Hyun Ryu;Yangwon Lee
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.5_3
    • /
    • pp.1061-1067
    • /
    • 2023
  • In this letter, we simulated an atmospheric correction for Sentinel-2 images, of which spectral bands are similar to Compact Advanced Satellite 500-4 (CAS500-4). Using the second simulation of the satellite signal in the solar spectrum - vector (6SV)2.1 radiation transfer model and random forest (RF), a type of machine learning, we developed an RF-based atmospheric correction model to simulate 6SV2.1. As a result, the similarity between the reflectance calculated by 6SV2.1 and the reflectance predicted by the RF model was very high.

The Study on Design of Customized Radiation Protective Layer for Medical Radiation Dose Reduction (의료방사선 피폭선량 저감을 위한 맞춤형 차폐재 설계에 관한 연구)

  • Kang, Sang-Sik;Kim, Kyo-Tae;Noh, Si-Cheol;Jung, Bong-Jae;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.6
    • /
    • pp.333-338
    • /
    • 2014
  • The fact is that in addition to an increase in social needs that must be managed systematically unnecessary exposure in the field of medical Recent important that the shield has emerged. However, products that are now in practical use, are not subdivided as compared to various medical radiology. Therefore, in the present study, we tried to present with the help of Monte Carlo simulation the structure of the shielding material that has been optimized. Simulated estimation result, the energy of the mammography for (30 kVp) spectrum, check the shielding rate of 90% or more $30{\mu}mPb$, at 2 mmAl case of shielding material of a single, at design time of 1 mmAl and 0.03 mmPb a double shield structure it is determined that more efficient. Also, check the blocking rate of 90% or more $340{\mu}mPb$, at 30 mmAl energy captured general in (80 kVp) spectra, it is considered that a double shield structure, design 1 mmAl and 0.3 mmPb is useful. These results, be used as basic material for the development of commercialization customized products for dose reduction is expected.

Radiolabeling of 11C-sertraline by fast and easy loop method with [11C]CH3OTf

  • Lee, Hak Jeong;Jeong, Jae Min;Lee, Sang-Yoon;Ido, Tatsuo
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.3 no.1
    • /
    • pp.32-37
    • /
    • 2017
  • Cis-(1S,4S)-4-(3,4-dichlorophenyl)-1,2,3,4-tertrahydro-N-methyl-1-naphthalenamine (sertraline) hydrochloride from among selective serotonin reuptake inhibitors (SSRIs) is a treatment of major depression. For the differential diagnosis by metabolizing serotonin in a patient with neurological disorders, the radiolabeled $^{11}C$-sertraline was developed for non-invasive positron emission tomography in living brain and use the evaluation of new drug for SSRIs. We release the results of a fast and easy radiolabeling method applied a one-step loop method with $[^{11}C]CH_3OTf$ for routine clinical applications of $^{11}C$-sertraline. 1 mg of a precursor for $^{11}C$-sertraline in 0.1 mL DMF and $5{\mu}L$ of 1N NaOH, were injected into the loop of semi-prep high-performance liquid chromatography (HPLC). $[^{11}C]CH_3OTf$ was passed through the loop at room temperature (RT). The $^{11}C$-sertraline was separated by the semi-preparative HPLC. $^{11}C$-sertraline was eluted at 28.0 min was collected and evaluated by analytical HPLC and mass spectrometer. The total radiolabeling efficiency of $^{11}C$-sertraline was $30.7{\pm}8.7%$. The specific activity was $64.8{\pm}51.4GBq/{\mu}mol$. The radiochemical and chemical purities were higher than 99%. The mass spectrum of the product showed m/z peaks at 307.1 (M+1), indicating the mass of sertraline. By the one-step loop method with $[^{11}C]CH_3OTf$, $^{11}C$-sertraline could be quickly and easily prepared for clinical application.

Peak Analysis of Gamma-ray and X-ray (감마선 및 엑스선의 피이크 분석)

  • Kim, Seung-Kon;Herr, Young-Hoi;Park, Kwang-June
    • Journal of Radiation Protection and Research
    • /
    • v.9 no.1
    • /
    • pp.33-42
    • /
    • 1984
  • A great variety of nuclear gamma rays emitted from fission and activation products of spent nuclear fuel contains much information that can be elicited without affecting the integrity of the fuel elements. But the extraction of such information from the complex spectrum is difficult and requires computer codes. In the present work, a versatile code 'CAERI' was developed which locates peaks and calculates their areas for X-rays as well as gamma rays using elegant features of some widely used programs for gamma-ray peak fitting. 'CAERI' coded in FORTRAN used infinite series approximation more accurate than other workers various, simple, piecewise series approximations for evaluations of the Voigt function which represents the X-ray peak with non-negligible natural line width. 'CAERI' can handle even a complex multiplet consisting of peaks from X-rays and gamma rays in arbitrary mixture, which one often encounters in the isotopic analysis of heavy elements such as U and Pu. The results of the fitting performed on the test spectra of $^{177m}\;Lu\;{\gamma}-ray\;and\;^{235}U\;K_{\alpha}$X-ray show good agreement with those by previous workers.

  • PDF