• 제목/요약/키워드: Radiation source detection

검색결과 109건 처리시간 0.023초

A lightweight true random number generator using beta radiation for IoT applications

  • Park, Kyunghwan;Park, Seongmo;Choi, Byoung Gun;Kang, Taewook;Kim, Jongbum;Kim, Young-Hee;Jin, Hong-Zhou
    • ETRI Journal
    • /
    • 제42권6호
    • /
    • pp.951-964
    • /
    • 2020
  • This paper presents a lightweight true random number generator (TRNG) using beta radiation that is useful for Internet of Things (IoT) security. In general, a random number generator (RNG) is required for all secure communication devices because random numbers are needed to generate encryption keys. Most RNGs are computer algorithms and use physical noise as their seed. However, it is difficult to obtain physical noise in small IoT devices. Since IoT security functions are required in almost all countries, IoT devices must be equipped with security algorithms that can pass the cryptographic module validation programs of each country. In this regard, it is very cumbersome to embed security algorithms, random number generation algorithms, and even physical noise sources in small IoT devices. Therefore, this paper introduces a lightweight TRNG comprising a thin-film beta-radiation source and integrated circuits (ICs). Although the ICs are currently being designed, the IC design was functionally verified at the board level. Our random numbers are output from a verification board and tested according to National Institute of Standards and Technology standards.

DEVELOPMENT OF LEAD SLOWING DOWN SPECTROMETER FOR ISOTOPIC FISSILE ASSAY

  • Lee, YongDeok;Park, Chang Je;Ahn, Sang Joon;Kim, Ho-Dong
    • Nuclear Engineering and Technology
    • /
    • 제46권6호
    • /
    • pp.837-846
    • /
    • 2014
  • A lead slowing down spectrometer (LSDS) is under development for analysis of isotopic fissile material contents in pyro-processed material, or spent fuel. Many current commercial fissile assay technologies have a limitation in accurate and direct assay of fissile content. However, LSDS is very sensitive in distinguishing fissile fission signals from each isotope. A neutron spectrum analysis was conducted in the spectrometer and the energy resolution was investigated from 0.1eV to 100keV. The spectrum was well shaped in the slowing down energy. The resolution was enough to obtain each fissile from 0.2eV to 1keV. The detector existence in the lead will disturb the source neutron spectrum. It causes a change in resolution and peak amplitude. The intense source neutron production was designed for ~E12 n's/sec to overcome spent fuel background. The detection sensitivity of U238 and Th232 fission chamber was investigated. The first and second layer detectors increase detection efficiency. Thorium also has a threshold property to detect the fast fission neutrons from fissile fission. However, the detection of Th232 is about 76% of that of U238. A linear detection model was set up over the slowing down neutron energy to obtain each fissile material content. The isotopic fissile assay using LSDS is applicable for the optimum design of spent fuel storage to maximize burnup credit and quality assurance of the recycled nuclear material for safety and economics. LSDS technology will contribute to the transparency and credibility of pyro-process using spent fuel, as internationally demanded.

근접방사선치료 QA에서 CsPbI2Br과 CsPbIBr2를 이용한 상대 선량계들의 검출 능력 비교 및 적용가능성 평가 (Comparative and Feasibility Evaluation of Detection Ability of Relative Dosimeters using CsPbI2Br and CsPbIBr2 Materials in Brachytherapy QA)

  • 양승우;박성광
    • 한국방사선학회논문지
    • /
    • 제17권3호
    • /
    • pp.433-440
    • /
    • 2023
  • High dose rate brachytherapy은 선량률이 높은 동위원소를 체내에 넣어 종양에 방사선을 집중적으로 조사하는 암 치료법이다. 이러한 치료를 위해서는 정확한 치료 계획을 통하여 종양 조직에는 적확한 선량을 조사하면서도 정상조직에는 최소한의 선량만을 전달될 수 있도록 하여야 한다. 그래서 임상에서는 정확한 품질보증(QA)을 통해 선원의 위치정확성을 확인하는 것이 매우 중요하다. 하지만 임상에서 소스 위치는 눈금자, 자동 방사선 사진기, 비디오 모니터 등을 사용하여 결정되므로 부정확한 결과를 산출한다. 이에 본 연구에서는 CsPbI2Br과 CsPbIBr2를 활용한 새로운 반도체 선량계를 제작하였다. 그리고 두 물질 중에 근접방사선치료기용 relative QA에 측정에 적합한지 분석하고자 각각의 방사선 검출 능력을 비교 평가하였다. 근접방사선치료에서의 방사선 검출 능력 평가하기 위하여 192IR에서 두 물질의 재현성, 선형성을 평가하였다. 재현성 평가에서 CsPbI2Br는 relative standard deviation(RSD) 0.98%로 제시되었고 CsPbIBr2는 RSD 3.45%로 제시되었다. 선형성 평가에서는 CsPbI2Br의 결정계수(coefficient of determination, R2)가 0.9998로 제시되었으며, CsPbIBr2의 R2은 0.9994로 제시되었다. 평가결과, 본 실험에서 제작된 선량계에서 평가 기준을 만족하면서도 방사선 검출이 더 안정적인 것은 CsPbI2Br로 나타났다. 따라서, CsPbI2Br 물질이 근접방사선치료 장치의 방사선 검출을 위한 상대 선량계로 적용하기에 적합하다.

초음파 서모그라피를 이용한 빠른 PCB 결함 검출 (Fast Defect Detection of PCB using Ultrasound Thermography)

  • 조재완;정현규;서용칠;정승호;김승호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.273-275
    • /
    • 2005
  • Active thermography is being used since several years for remote non-destructive testing. It provides thermal images for remote detection and imaging of damages. Also, it is based on propagation and reflection of thermal waves which are launched from the surface into the inspected component by absorption of modulated radiation. For energy deposition, it use external heat sources (e.g., halogen lamp or convective heating) or internal heat generation (e.g., microwaves, eddy current, or elastic wave). Among the external heat sources, the ultrasound is generally used for energy deposition because of defect selective heating up. The heat source generating a thermal wave is provided by the defect itself due to the attenuation of amplitude modulated ultrasound. A defect causes locally enhanced losses and consequently selective heating up. Therefore amplitude modulation of the injected ultrasonic wave turns a defect into a thermal wave transmitter whose signal is detected at the surface by thermal infrared camera. This way ultrasound thermography(UT) allows for selective defect detection which enhances the probability of defect detection in the presence of complicated intact structures. In this paper the applicability of UT for fast defect detection is described. Examples are presented showing the detection of defects in PCB material. Measurements were performed on various kinds of typical defects in PCB materials (both Cu metal and non-metal epoxy). The obtained thermal image reveals area of defect in row of thick epoxy material and PCB.

  • PDF

방류수의 방사능 오염 측정을 위한 배열형 SiPM 기반 방사선 검출 센서 제작 (Development of Radiation Sensor Based on Array SiPM for Measurement of Radioactive Contamination in Effluent)

  • 김정호;박혜민;주관식
    • 센서학회지
    • /
    • 제27권4호
    • /
    • pp.232-236
    • /
    • 2018
  • A radiation detection sensor was developed and characterized by combining three types of CsI(Tl) scintillators and an array-type SiPM to detect the radioactive contamination of discharged water in real time. The characterization results showed that type 3 exhibited the most desirable characteristics in response linearity (R-square: 0.97889) according to detection sensitivity and incident radiation dose. Furthermore, in terms of spectral characteristics, type 3 exhibited 16.54% at 0.356 MeV (the emission gamma ray energy of $^{133}Ba$), 10.28% at 0.511 MeV (the emission gamma ray energy of $^{22}Na$), 9.68% at 0.356 MeV (the emission gamma ray energy of $^{137}Cs$), and 2.55% and 4.80% at 1.173 MeV and 1.332 MeV (the emission gamma ray energies of $^{60}Co$), respectively. These measurements confirmed the good energy characteristics. The results were used to evaluate the spectral characteristics and energy linearity in a mixed source using type 3 with the best detection characteristics. It was confirmed that the gamma ray peaks of $^{133}Ba$, $^{22}Na$, $^{137}Cs$, and $^{60}Co$ were well resolved. Moreover, it was confirmed that R-square, which is an indicator of energy linearity, was 0.99986. This indicates a good linearity characteristic. Based on this study, further commercialization studies will contribute to measurements in real time and to the management of the contamination caused by radioactive wastewater or radioactive material leakage, which originate from facilities that use radioactive isotopes or care facilities.

물리적인 방법(PSL, TL, ESR)을 이용한 방사선 조사 건조과일의 검지 특성 (Detection Properties of Irradiated Dried Fruits by Using Photo-stimulated Luminescence, Thermoluminescence, and Electronspin Resonance Methods)

  • 윤영민;박재남;최수정;박종흠;김재경;변의백;이주운;한인준;박진규;김재훈;송범석
    • 방사선산업학회지
    • /
    • 제8권1호
    • /
    • pp.11-15
    • /
    • 2014
  • In this study, we investigated the applicability of the photostimulated luminescence (PSL), thermoluminescence (TL) and electron spin resonance (ESR) methods for freeze dried fruits which are not allowed to be irradiated in Korea. Apples and persimmons samples that had been dried with a freeze drier were irradiated at a dose of 1, 3, 5, 7, and 10 kGy, using a gamma radiator with a cobalt-60 source. With the PSL method, the dried apples showed photon counts of less then 700 counts/60 s (negative) in all the samples, whereas the dried persimmons that were gamma-irradiated above 3 kGy yielded photon counts of between 700 and 5,000 counts/60 s (intermediate). The TL results showed that this technique is useful for detecting irradiated samples; the TL ratios ($TL_1/TL_2$) measured for the food samples at an irradiation dose of 1 kGy were 0.13 for dried apples and 0.79 for dried persimmons. With regard to the results of ESR spectroscopy, the strength of the ESR signals from the dried fruits increased linearly in a dosedependent manner. However, the characteristic signal was not found in all the samples. In conclusion, the TL methods only can be used for the detection of gamma-irradiated dried apples and persimmons.

Comparison of theoretical and machine learning models to estimate gamma ray source positions using plastic scintillating optical fiber detector

  • Kim, Jinhong;Kim, Seunghyeon;Song, Siwon;Park, Jae Hyung;Kim, Jin Ho;Lim, Taeseob;Pyeon, Cheol Ho;Lee, Bongsoo
    • Nuclear Engineering and Technology
    • /
    • 제53권10호
    • /
    • pp.3431-3437
    • /
    • 2021
  • In this study, one-dimensional gamma ray source positions are estimated using a plastic scintillating optical fiber, two photon counters and via data processing with a machine learning algorithm. A nonlinear regression algorithm is used to construct a machine learning model for the position estimation of radioactive sources. The position estimation results of radioactive sources using machine learning are compared with the theoretical position estimation results based on the same measured data. Various tests at the source positions are conducted to determine the improvement in the accuracy of source position estimation. In addition, an evaluation is performed to compare the change in accuracy when varying the number of training datasets. The proposed one-dimensional gamma ray source position estimation system with plastic scintillating fiber using machine learning algorithm can be used as radioactive leakage scanners at disposal sites.

방사선 근접치료 디지털 선량계의 성능 개선을 위한 Passive Layer의 효과 (Effect of Passive Layer to Improve Performance of Digital Dosimeter in Brachytherapy)

  • 한무재;양승우;박성광
    • 한국방사선학회논문지
    • /
    • 제15권5호
    • /
    • pp.715-721
    • /
    • 2021
  • 방사선 근접치료에서 잘못된 선원의 위치는 정상조직에 과도한 선량을 유발할 수 있다. 그러므로 아날로그 검출방식을 대체하기 위해 디지털 선량계에 대한 연구가 이루어지고 있다. 이에 본 연구는 선량계 성능 개선을 위한 기초연구로써 passive layer (PL)를 적용한 lead (II) oxide (PbO) 선량계를 제작하였다. 이후 Ir-192 선원의 조사조건에 대한 성능을 분석하기 위해 재현성, 선형성, 거리의존성을 평가하였다. 재현성은 PL-PbO 선량계에서 상대표준편차가 0.40%로 평가 기준 1.5% 이내를 만족하였고, PbO 선량계보다 개선된 결과를 보였다. 선형성은 선형함수 R2이 0.9995로 우수한 결과를 보였고, 선형함수의 회귀분석을 통한 기울기 분석은 PL-PbO에서 우수하였다. 거리 의존성은 거듭제곱함수의 회귀분석을 통해 얻은 기울기를 inverse square value와 비교하였을 때, PL-PbO 선량계는 PbO에 비해 +0.599 높게 나타났다. 본 연구는 고체선량계의 계측 구성에 따른 효과와 측정 변수를 제시하고 있고, 다양한 방사선 검출 분야에서 활용될 수 있다.

스테레오 기반 감마선원 탐지 및 가시화에 관한 연구 (Study of the Radioactive Source Detection and the Visualization with the Stereo Radiation Detector)

  • 박강택;이남호;차한주
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2015년도 추계학술대회
    • /
    • pp.1100-1102
    • /
    • 2015
  • 본 논문에서는 스테레오 기반 감마선원 탐지장치를 통해 감마선원을 포함하는 공간을 래스터 스캔방식으로 스캔하여 가시광영상과 감마선영상을 획득하고, 스테레오 감마선 탐지장치로부터 선원까지의 거리와 방향에 대한 3차원 정보 획득 및 가시화를 수행하였다. 탐지장치의 구성은 감마선원 탐지를 위한 방사선 검출부, 선원탐지를 위해 래스터스캔방식의 스캔을 위한 팬틸트 그리고 가시광영상을 위한 CCD 카메라로 이루어진다. 선원에 대한 공간분포를 측정하기 위해 스테레오 구조의 장치를 구현하였으며 스테레오 영상획득을 위해 CCD 카메라와 감마선 탐지장치는 각각 2대로 구성하였다. 탐지선원에 대한 분포를 나타내기 위해 감마선 탐지 장치와 가시광 카메라에 대한 보정을 수행하였고, 각각의 카메라에 대한 스테레오 보정을 수행한 후 가시광영상과 감마선영상 중첩을 통해 감마선원에 대한 분포를 나타내었다. 좌, 우 분포영상에 대한 정류화처리 후 스테레오 영상에 대한 가시화결과를 도출하였다.

  • PDF

표준 감마선 전리함 장치에 의한 방사능 비교 측정 (Comparative Measurement of Radioactivity with Standard Gamma-ray Ionization Chamber System)

  • 박태순;우동호;오필제;황선태
    • Journal of Radiation Protection and Research
    • /
    • 제9권1호
    • /
    • pp.11-18
    • /
    • 1984
  • Well type 전리함과 미세전류 측정희로를 사용하여 표준 감마선 전리함 장치를 개발하였다. 미세전류는 automatic Townsend balance with stepwise compensation방법을 사용하여 측정하였다. $^{226}Ra$을 기준 선원으로 택하여 감마 방출핵종인 $^{241}Am,\;^{133}Ba,\;^{60}Co,\;^{134}Cs,\;^{137}Cs^{22}Na$에 대한 비교 교정인자를 산출하였으며, 감마에너지의 함수로서 검출 효율 곡선을 구하였다.

  • PDF