• 제목/요약/키워드: Radiation shielding and protection

검색결과 198건 처리시간 0.018초

Evaluation of a Curtain-Type Radiation Protection Device for Veterinary Interventional Procedures

  • Minsik Choi;Jaepung Han;Changgyu Lim;Jiwoon Park;Sojin Kim;Uhjin Kim;Jinhwa Chang;Dongwoo Chang;Namsoon Lee
    • 한국임상수의학회지
    • /
    • 제41권3호
    • /
    • pp.157-164
    • /
    • 2024
  • The standard radiation protection method in the angiography suite involves the use of a thyroid shield, a lead apron, and lead glasses. However, exposure to substantial amounts of ionizing radiation can cause cataracts, tumors, and skin erythema. A newly developed curtain-type radiation protection device consists of a curtain drape composed of a five-layer bismuth and lead acrylic head-shielding plate, with both bearing an equivalent 0.25 mm lead thickness. In this study, a quality assurance phantom was used as the patient to create radiation scatter from the radiographic source, and an anthropomorphic mannequin phantom was used as the interventionalist to measure the radiation dose at seven different anatomical locations. Thermoluminescent dosimeters were used to measure the radiation dose. The experimental groups consisted of all-sided or one-sided curtain set-ups, the presence or absence of a conventional shielding system, and the orientation of beam irradiation. Consequently, the curtain-type radiation protection device exhibited better radiation protection range and capabilities than conventional radiation protection systems, especially in safeguarding the forehead, eyes, arms, and feet, with minimal radiation exposure. Moreover, the mean shielding ratios of the conventional shielding system and curtain-type radiation protection device were measured at 51.94% and 93.86%, respectively. Additionally, no significant decrease in the radiation protection range or capability was observed, even with changes in the beam orientation or one-sided protection. Compared with a conventional shielding system, the curtain-type radiation protection device decreased radiation exposure doses and improved comfort. Therefore, it is a potential new radiation protection device for veterinary interventional procedures.

Measurements and Assessments on Shielding Performance of FCTC10 60Co Transport Container

  • Zhuang, Dajie;Zhang, Guoqing;Li, Guoqiang;Wang, Renze
    • Journal of Radiation Protection and Research
    • /
    • 제41권3호
    • /
    • pp.310-314
    • /
    • 2016
  • Background: FCTC10 container is designed to transport $^{60}Co$ radioactive sources used in irradiation industry. It belongs to Type B(U) Category III (yellow) package when being loaded with a $^{60}Co$ source of $1.8{\times}10^5$ Ci. Materials and Methods: The container is constituted of shielding container, basket, protective cover and bracket. Shielding ability is provided mainly by stainless steel shells, tungsten alloy and lead among steel shells. Radiation level around the container has been calculated with both Monte Carlo simulations and measurements. Results and Discussion: It is proven that the shielding performance of the container fulfills the requirements in GB11806-2004 (Regulations for the safe transport of radioactive material, China Standard Press). Exposure doses to workers and to critical groups of public were calculated based on hypothetical exposure scene according to transport practice experience. Conclusion: The results show that doses to workers and public are less than the constraint dose considered in design, and the radiation level would be increased less than a factor of 2 under design basis accidents.

방사선방어 앞치마 성능 평가 (Performance Evaluation of Radiation Protection Apron's)

  • 강종구;강병삼
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권5호
    • /
    • pp.373-377
    • /
    • 2019
  • Radiation exposure is on the rise as the working hours of radiation workers increase. Accordingly, the importance of protection products for decreasing the dose of exposure has risen, and excellent X-ray shielding ability and light weight are required. The purpose of this study is to compare the Pb which use currently and other elements in order to reduce the exposure of workers to the most effective protection products. For experiment, we used the general X-ray equipment and angiography equipment, and obtained the Pb and apron's shielding rate. When the shielding rate of Pb and apron was compared in general X-ray equipment, the shielding rate was 95.1% for Pb 0.5 mm, 96.1% for apron 0.5 mmPb and 95.6% for Bi+W 0.5 mmPb. When compared the shielding rate of each aprons in angiography equipment, 0.5 mmPb apron was the highest as 96.4% and Bi+W 0.25 mmPb apron was the lowest as 90.2% at the 50 cm distance. The shielding rate of 0.5 mmPb apron was the highest as 95.7% and Bi+W 0.25 mmPb apron was the lowest as 85.9% at the 100 cm distance. As a result of evaluating the apron efficiency through this study, 0.5 mmPb apron showed the best shielding rate, but it was the heaviest apron. 0.35 mmPb apron and Bi+W 0.25 mmPb apron weighed light but had low shielding rate. Through the results of this experiment, it is recommended that radiation workers reduce radiation exposure by using more efficient protection products.

Enhancing Gamma-Neutron Shielding Effectiveness of Polyvinylidene Fluoride for Potent Applications in Nuclear Industries: A Study on the Impact of Tungsten Carbide, Trioxide, and Disulfide Using EpiXS, Phy-X/PSD, and MCNP5 Code

  • Ayman Abu Ghazal;Rawand Alakash;Zainab Aljumaili;Ahmed El-Sayed;Hamza Abdel-Rahman
    • Journal of Radiation Protection and Research
    • /
    • 제48권4호
    • /
    • pp.184-196
    • /
    • 2023
  • Background: Radiation protection is crucial in various fields due to the harmful effects of radiation. Shielding is used to reduce radiation exposure, but gamma radiation poses challenges due to its high energy and penetration capabilities. Materials and Methods: This work investigates the radiation shielding properties of polyvinylidene fluoride (PVDF) samples containing different weight fraction of tungsten carbide (WC), tungsten trioxide (WO3), and tungsten disulfide (WS2). Parameters such as the mass attenuation coefficient (MAC), half-value layer (HVL), mean free path (MFP), effective atomic number (Zeff), and macroscopic effective removal cross-section for fast neutrons (ΣR) were calculated using the Phy-X/PSD software. EpiXS simulations were conducted for MAC validation. Results and Discussion: Increasing the weight fraction of the additives resulted in higher MAC values, indicating improved radiation shielding. PVDF-xWC showed the highest percentage increase in MAC values. MFP results indicated that PVDF-0.20WC has the lowest values, suggesting superior shielding properties compared to PVDF-0.20WO3 and PVDF-0.20WS2. PVDF-0.20WC also exhibited the highest Zeff values, while PVDF-0.20WS2 showed a slightly higher increase in Zeff at energies of 0.662 and 1.333 MeV. PVDF-0.20WC has demonstrated the highest ΣR value, indicating effective shielding against fast neutrons, while PVDF-0.20WS2 had the lowest ΣR value. The Monte Carlo N-Particle Transport version 5 (MCNP5) simulations showed that PVDF-xWC attenuates gamma radiation more than pure PVDF, significantly decreasing the dose equivalent rate. Conclusion: Overall, this research provides insights into the radiation shielding properties of PVDF mixtures, with PVDF-xWC showing the most promising results.

일반촬영분야에서의 3D 프린터로 제작한 텅스텐 혼합 필라멘트 차폐체의 성능평가 (Evaluation of Tungsten Blended Filament Shields Made by 3D Printer in Radiography)

  • 윤준;윤명성
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권6호
    • /
    • pp.615-621
    • /
    • 2021
  • In the medical field, radiation provides information for the diagnosis and treatment of diseases. As the use of radiation increases and the risk of exposure increases, interest in radiation protection is also rapidly increasing. Lead shielding material is mainly used, which has a risk of lead poisoning and absorption into the body. Tungsten mixed filament shielding sheets were fabricated with a size of 70 × 70 mm and a thickness of 1, 2, and 4 mm by using a 3D printer. In the general shooting experiment, the thickness of the shielding sheet is 1 ~ 5mm, the tube voltage is 60, 80, 100, 120 kVp and the tube current is 20, 40 mAs. In general photography, Tungsten showed better shielding rate compared to Brass, Copper, and Lead protective tools under all irradiation conditions, and in particular, Tungsten 5 mm showed 100% shielding rate. The 3D-printed tungsten mixed filament shielding is expected to be used as a new shield that can replace the existing lead protection tools as it shows a better shielding rate than the existing lead protection tools in Radiography.

Effect of Heat Treatment on Radiation Shielding Properties of Concretes

  • Singh, Vishwanath P.;Tekin, Huseyin O.;Badiger, Nagappa M.;Manici, Tubga;Altunsoy, Elif E.
    • Journal of Radiation Protection and Research
    • /
    • 제43권1호
    • /
    • pp.20-28
    • /
    • 2018
  • Background: Heat energy produced in nuclear reactors and nuclear fuel cycle facilities interactions modifies the physical properties of the shielding materials containing water content. Therefore, in the present paper, effect of the heat on shielding effectiveness of the concretes is investigated for gamma and neutron. The mass attenuation coefficients, effective atomic numbers, fast neutron removal cross-section and exposure buildup factors. Materials and Methods: The mass attenuation coefficients, effective atomic numbers, fast neutron removal cross-section and exposure buildup factors of ordinary and heavy concretes were investigated using NIST data of XCOM program and Geometric Progression method. Results and Discussion: The improvement in shielding effectiveness for photon and reduction in fast neutron for ordinary concrete was observed. The change in the neutron shielding effectiveness was insignificant. Conclusion: The present investigation on interaction of gamma and neutron radiation would be very useful for assessment of shielding efficiency of the concrete used in high temperature applications such as reactors.

Personal Dosimeters Worn by Radiation Workers in Korea: Actual Condition and Consideration of Their Proper Application for Radiation Protection

  • Eunbi Noh;Dalnim Lee;Sunhoo Park;Songwon Seo
    • Journal of Radiation Protection and Research
    • /
    • 제48권3호
    • /
    • pp.162-166
    • /
    • 2023
  • Background: Assessment of the radiation doses to which workers are exposed can differ depending on the placement of dosimeters on the body. In addition, it is affected by whether the placement is under or over a shielding apron. This study aimed to evaluate the actual positioning of personal dosimeters on the body, with or without shielding aprons, among radiation workers in Korea. Materials and Methods: We analyzed the survey data, which included demographic characteristics, such as sex, age, occupation, work history, and placement of the personal dosimeter being worn, from a cohort study of Korean radiation workers. We assessed the use of personal dosimeters among workers, stratified by sex, age, working period, starting year of work, and occupation. Results and Discussion: Overall, high compliance (89.1% to 99.0%) with the wearing of dosimeters on the chest was observed regardless of workers' characteristics, such as age, sex, occupation, and work history. However, the placement of dosimeters, either under or over the shielding aprons, was inconsistent. Overall, 40.1% of workers wore dosimeters under their aprons, while the others wore dosimeters over their aprons. This inconsistency indicates that radiation doses are possibly measured differently under the same exposure conditions solely owing to variations in the placement of worn dosimeters. Conclusion: Although a lack of uniformity in dosimeter placement when wearing a shielding apron may not cause serious harm in radiation dose management for workers, the development of detailed guidelines for dosimeter placement may improve the accuracy of dose assessment.

IPEM Report-78의 엑스선 스펙트럼을 이용한 방사선 방호장비의 차폐율 계산 (Calculation of Shielding Rate of Radiation Protective Equipment Using the X-ray Spectrum of IPEM Report-78)

  • 한동현
    • 한국방사선학회논문지
    • /
    • 제15권5호
    • /
    • pp.755-760
    • /
    • 2021
  • 본 연구에서는 IPEM(The Institute of Physics and Engineering in Medicine) Report 78의 진단용 엑스선 발생장치에서 방출되는 엑스선 스펙트럼 데이터를 이용하여 의료 환경에서 사용되는 주요 엑스선 방호장비의 차폐율을 계산하고, 방사선 방호분야 적용가능성을 알아보았다. 진단용 엑스선 방호에 이용되는 납 앞치마(0.3 mmPb), 갑상샘 차폐체(0.5 mmPb), 납 고글(0.5 mmPb), 납 유리(1.8, 2.7, 3.3 mmPb)를 대상으로 에어커마와 엑스선 총강도의 감소율을 통해 방사선 차폐율을 계산하였다. 그 결과 에어커마 감소율로 계산한 차폐율은 80 kV에서 96.31~100 %범위였고, 120 kV에서는 90.35~100%범위로 나타났다. 또한 본 계산의 결과가 실제 차폐율 측정한 선행연구결과와 잘 일치하여 IPEM Report 78의 엑스선 스펙트럼 데이터가 방사선 방호에 활용될 수 있을 것으로 기대된다.

A New Radiation-Shielding Device for Restraining Veterinary Patients

  • Songyi Kim;Minju Lee;Miju Oh;Yooyoung Lee;Jiyoung Ban;Jiwoon Park;Sojin Kim;Uhjin Kim;Jaepung Han;Dongwoo Chang
    • 한국임상수의학회지
    • /
    • 제40권6호
    • /
    • pp.429-437
    • /
    • 2023
  • In veterinary medicine, most radiographic images are obtained by restraining patients, inevitably exposing the restrainer to secondary scattered radiation. Radiation exposure can result in stochastic reactions such as cancer and genetic effects, as well as deterministic reactions such as skin burns, cataracts, and bone marrow suppression. Radiation-shielding equipment, including aprons, thyroid shields, eyewear, and gloves, can reduce radiation exposure. However, the risk of radiation exposure to the upper arms, face, and back remains, and lead aprons and thyroid shields are heavy, restricting movement. We designed a new radiation-shielding system and compared its shielding ability with those of conventional radiation-shielding systems. We hypothesized that the new shielding system would have a wider radiation-shielding range and similar shielding ability. The radiation exposure dose differed significantly between the conventional and new shielding systems in the forehead, chin, and bilateral upper arm areas (p < 0.001). When both systems were used together, the radiation-shielding ability was better than when only one system was used at all anatomical locations (p < 0.01). This study suggests that the new radiation-shielding system is essential and convenient for veterinary radiation workers because it is a step closer to radiation safety in veterinary radiography.