• Title/Summary/Keyword: Radiation response

Search Result 1,322, Processing Time 0.034 seconds

The Pattern of Failure after Definitive Radiotherapy for Squamous Cell Carcinoma of the Lung (편평상피 세포성 폐암의 방사선치료 실패 양상)

  • Jang Yang Suk;Kim Jae Cheol;Ryu Samuel;Park In Kyu
    • Radiation Oncology Journal
    • /
    • v.7 no.1
    • /
    • pp.45-50
    • /
    • 1989
  • From Feb.1985 to Feb.1988,76 patients with squamous cell carcinoma of the lung treated at the Department of Therapeutic Radiology in Kyungpook National University Hospital were available for the analysis of this study. All patients received radiation of 4000cGy-6600cGy with curative aim. The overall rate of complete response was 25.0% and partial response was 452.6% The complete and partial regression of tumor was 14.3% in patients treated with dose below 5000cGy and 84.1% in the group treated with dose above 5000cGy (p<0.01). The complete response was seen only in the group of patients received radiation at least 6000cGy. The patterns of failure were as follows. The rate of initial intrathoracic recurrence was 52.6% in patients with complete response. The overall rate of failure was 68.8%. Distant metastasis was found in 47.4% of patients. Bone, contralateral lung, and brain were common metastatic sites in decreasing order All of the distant metastases and 80% of local recurrences were found within the first year after treatment.

  • PDF

Estimating dose-response curves using splines: a nonparametric Bayesian knot selection method

  • Lee, Jiwon;Kim, Yongku;Kim, Young Min
    • Communications for Statistical Applications and Methods
    • /
    • v.29 no.3
    • /
    • pp.287-299
    • /
    • 2022
  • In radiation epidemiology, the excess relative risk (ERR) model is used to determine the dose-response relationship. In general, the dose-response relationship for the ERR model is assumed to be linear, linear-quadratic, linear-threshold, quadratic, and so on. However, since none of these functions dominate other functions for expressing the dose-response relationship, a Bayesian semiparametric method using splines has recently been proposed. Thus, we improve the Bayesian semiparametric method for the selection of the tuning parameters for splines as the number and location of knots using a Bayesian knot selection method. Equally spaced knots cannot capture the characteristic of radiation exposed dose distribution which is highly skewed in general. Therefore, we propose a nonparametric Bayesian knot selection method based on a Dirichlet process mixture model. Inference of the spline coefficients after obtaining the number and location of knots is performed in the Bayesian framework. We apply this approach to the life span study cohort data from the radiation effects research foundation in Japan, and the results illustrate that the proposed method provides competitive curve estimates for the dose-response curve and relatively stable credible intervals for the curve.

Adaptive Response Induced by Low Dose Ionizing Radiation in Human Lymphocytes (인체 말초 혈액 림프구에서 저선량 방사선 조사에 의해 유도되는 적응 반응)

  • Kim, Jeong-Hee;Lee, Kyung-Jong;Cho, Chul-Koo;Yoo, Seong-Yul;Kim, Tae-Hwan;Kim, Sung-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.2
    • /
    • pp.97-102
    • /
    • 1995
  • Adaptive response induced by low dose ${\gamma}-ray$ irradiation in human peripheral lymphocytes was examimed. Human lymphocytes were exposured to low dose of ${\gamma}-ray$ (priming dose, 0.01Gy) followed by high dose (challenging dose, 1.5Gy) after various time intervals (4, 7, 20 hours). Frequencies of micronuclei were enumerated in both primed and unprimed groups. Maximum reduction in frequency of micronuclei was observed when challenging dose irradiation was followed by priming dose after 4hr incubation period. When challenging doses were irradiated 7 or 20hr after priming dose, frequencies of micronuclei were reduced slighty. However, these reduction were not statistically significant. In this study, human peripheral lymphocytes were irradiated at Go phase and they showed adaptive response induced by low dose radiation. Since micronucleus assay is relatively simpler and faster than other methods, it may be a good tool for evaluating radiation-induced adaptive responses.

  • PDF

Intracavitary Radiation Therapy for Recurrent Cystic Brain Tumors with Holmium-166-Chico : A Pilot Study

  • Ha, Eun Jin;Gwak, Ho-Shin;Rhee, Chang Hun;Youn, Sang Min;Choi, Chang-Woon;Cheon, Gi Jeong
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.3
    • /
    • pp.175-182
    • /
    • 2013
  • Objective : Intracavitary injection of beta-emitting radiation source for control of cystic tumors has been tried with a benefit of localized internal radiation. The authors treated cystic brain tumor patients with Holmium-166-chitosan complex (Ho-166-chico), composed of a beta-emitting radionuclide Holmium-166 and biodegradable chit polymer, and evaluated the safety and effective measurement for response. Methods : Twenty-two patients with recurrent cystic brain tumor and/or located in a deep or eloquent area were enrolled in this pilot study. The cyst volume and wall thickness were determined on CT or MRI to assess radiological response. The activity of Ho-166-chico injected via Ommaya reservoir was prescribed to be 10-25 Gy to the cyst wall in a depth of 4 mm. Results : There was neither complications related to systemic absorption nor leakage of Ho-166-chico in all 22 patients. But, two cases of oculomotor paresis were observed in patients with recurrent craniopharyngioma. Radiological response was seen in 14 of 20 available follow-up images (70%). Seven patients of 'evident' radiological response experienced more than 25% decrease of both cyst volume and wall thickness. Another 7 patients with 'suggestive' response showed decrease of cyst volume without definitive change of the wall thickness or vice versa. All patients with benign tumors or low grade gliomas experienced symptomatic improvement. Conclusion : Ho-166-chico intracavitary radiation therapy for cystic tumor is a safe method of palliation without serious complications. The determination of both minimal effective dosage and time interval of repeated injection through phase 1 trial could improve the results in the future.

Dose-Response Relationship of Micronucleus Frequency in Pollen Mother Cells of Tradescantia (자주달개비 화분모세포 미세핵 생성률의 방사선량-반응 관계)

  • Kim, Jin-Kyu;Song, Hi-Sup;Hyun, Soung-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.4
    • /
    • pp.225-230
    • /
    • 1999
  • This study was carried out to investigate the radiation dose-response of micronucleus frequencies in Tradescantia pollen mother cells. The number of micronuclei increased in the tetrads as a result of chromosome deletion after irradiation. The maximal frequency of micronuclei showed a good dose-response relationship in the range of dose $0{\sim}50$ cGy. On the basis of the relationship, a dose of 1 cGy results maximally in two additional micronuclei in 100 tetrads. The radiation dose-response relationship of micronucleus occurrence is prerequisite to biological monitoring of radiations. The micronucleus assay can be applied to biological risk assessment of environmental toxicants, and to integrity test of water or soils of interest.

  • PDF

PDCD4 as a Predictor of Sensitivity to Neoadjuvant Chemoradiotherapy in Locally Advanced Rectal Cancer Patients

  • Dou, Xue;Wang, Ren-Ben;Meng, Xiang-Jiao;Yan, Hong-Jiang;Jiang, Shu-Mei;Zhu, Kun-Li;Xu, Xiao-Qing;Chen, Dong;Song, Xian-Rang;Mu, Dian-Bin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.2
    • /
    • pp.825-830
    • /
    • 2014
  • Objective: The purpose of this study was to examine the role of programmed cell death 4 (PDCD4) expression in predicting tumor response to neoadjuvant chemoradiotherapy and outcomes for patients with locally advanced rectal cancer. Methods: Clinicopathological factors and expression of PDCD4 were evaluated in 92 patients with LARC treated with nCRT. After the completion of therapy, 4 cases achieved clinical complete response (cCR), and thus the remaining 88 patients underwent a standardized total mesorectal excision procedure. There were 38 patients (41.3%) with a good response (TRG 3-4) and 54 (58.7%) with a poor one (TRG 0-2). Results: Immunohistochemical staining analyses showed that patients with high expression of PDCD4 were more sensitive to nCRT than those with low PDCD4 expression (P=0.02). High PDCD4 expression before nCRT and good response (TRG3-4) were significantly associated with improved 5-year disease-free survival and 5-year overall survival (P<0.05). Multivariate analysis demonstrated that the pretreatment PDCD4 expression was an independent prognostic factor. Conclusion: Our study demonstrated that high expression of PDCD4 protein is a useful predictive factor for good tumor response to nCRT and good outcomes in patients with LARC.

Basic Dose Response of Fluorescent Screen-based Portal Imaging Device (섬광판을 사용하는 조사문영상기구의 기본적인 선량반응성)

  • Yeo, In-Hwan J.;Yohannes, Yonas;Zhu,Yunping
    • Radiation Oncology Journal
    • /
    • v.17 no.3
    • /
    • pp.249-255
    • /
    • 1999
  • Purpose : The purpose of this study is to investigate fundamental aspects of the dose response of fluorescent screen-based electronic portal imaging devices (EPIDS). Materials and Methods : We acquired scanned signal across portal planes as we varied the radiation that entered the EPID by changing the thickness and anatomy of the phantom as well as the air gap between the phantom and the EPID. In addition, we simulated the relative contribution of the scintillation light signal in the EPID system. Results : We have shown that the dose profile across portal planes is a function of the air gap and phantom thickness. We have also found that depending on the density change within the phantom geometry, errors associated with dose response based on the EPID scan can be as high as $7\%$. We also found that scintillation light scattering within the EPID system is an important source of error. Conclusion : This study revealed and demonstrated fundamental characteristics of dose response of EPID, as relative to that of ion chambers. This study showed that EPID based on fluorescent screen cannot be an accurate dosimetry system.

  • PDF

Retrospective dosimetry using fingernail electron paramagnetic resonance response

  • Noori, Abbas;Mostajaboddavati, Mojtaba;Ziaie, Farhood
    • Nuclear Engineering and Technology
    • /
    • v.50 no.3
    • /
    • pp.526-530
    • /
    • 2018
  • Human fingernails were used to estimate the radiation dose via electron paramagnetic resonance measurements of radiation-induced radicals. The limiting factors in this research were mechanically induced electron paramagnetic resonance signals due to the mechanical stress during the preparation of the samples. Therefore, different treatment methods of fingernails were used to reduce the mechanically induced signals. The results demonstrate that the mechanically induced and radiation-induced signals have apparently different microwave power saturation behaviors. In addition, the mechanically induced signal shows a fading evolution over time and reaches a constant value. Chemical treatment using the different reagents showed that the minimum mechanically induced signal was obtained using the dithiothreitol reagent. The dose-response curves of the samples treated with dithiothreitol for 30 minutes demonstrated a greater linearity than those of samples treated for 5 minutes. Therefore, to find an unknown absorbed dose in a fingernail sample using a calibration curve, we recommend adopting the mentioned chemical treatment procedure to reduce the uncertainty.

Genetic variations affecting response of radiotherapy

  • Choi, Eun Kyung
    • Journal of Genetic Medicine
    • /
    • v.19 no.1
    • /
    • pp.1-6
    • /
    • 2022
  • Radiation therapy (RT) is a very important treatment for cancer that irradiates a large amount of radiation to lead cancer cells and tissues to death. The progression of RT in the aspect of personalized medicine has greatly advanced over the past few decades in the field of technical precision responding anatomical characteristics of each patient. However, the consideration of biological heterogeneity that makes different effect in individual patients has not actually applied to clinical practice. There have been numerous discovery and validation of biomarkers that can be applied to improve the efficiency of radiotherapy, among which those related to genomic information are very promising developments. These genome-based biomarkers can be applied to identify patients who can benefit most from altering their therapeutic dose and to select the best chemotherapy improving sensitivity to radiotherapy. The genomics-based biomarkers in radiation oncology focus on mutational changes, particularly oncogenes and DNA damage response pathways. Although few have translated into clinically viable tools, there are many promising candidates in this field. In this review the prominent mutation-based biomarkers and their potential for clinical translation will be discussed.

Prognostic Significance of 18F-fluorodeoxyglucose Positron Emission Tomography (PET)-based Parameters in Neoadjuvant Chemoradiation Treatment of Esophageal Carcinoma

  • Ma, Jin-Bo;Chen, Er-Cheng;Song, Yi-Peng;Liu, Peng;Jiang, Wei;Li, Ming-Huan;Yu, Jin-Ming
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.4
    • /
    • pp.2477-2481
    • /
    • 2013
  • Aims and Background: The purpose of the research was to study the prognostic value of tumor 18F-FDG PET-based parameters in neoadjuvant chemoradiation for patients with squamous esophageal carcinoma. Methods: Sixty patients received chemoradiation therapy followed by esophagectomy and two 18FDG-PET examinations at pre- and post-radiation therapy. PET-based metabolic-response parameters were calculated based on histopathologic response. Linear regression correlation and Cox proportional hazards models were used to determine prognostic value of all PET-based parameters with reference to overall survival. Results: Sensitivity (88.2%) and specificity (86.5%) of a percentage decrease of SUVmax were better than other PET-based parameters for prediction of histopathologic response. Only percentage decrease of SUVmax and tumor length correlated with overall survival time (linear regression coefficient ${\beta}$: 0.704 and 0.684, P<0.05). The Cox proportional hazards model indicated higher hazard ratio (HR=0.897, P=0.002) with decrease of SUVmax compared with decrease of tumor size (HR=0.813, P=0.009). Conclusion: Decrease of SUVmax and tumor size are significant prognostic factors in chemoradiation of esophageal carcinoma.