• Title/Summary/Keyword: Radiation related workers

Search Result 83, Processing Time 0.018 seconds

Comparison on the Dosimetry of TLD and PLD by Dose Area Product (DAP(Dose Area Product)를 이용한 TLD와 PLD의 선량 측정 비교)

  • Choi, Jae-Ho;Kang, Gu-Jun;Chang, Seo-Goo
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.3
    • /
    • pp.244-250
    • /
    • 2012
  • The results of analyzing the difference between performances of individual dosimeters on this research subjecting the PLD and TLD, which are the official personal dosimeters, through dosimetry are as follows. After scanning the integral dose using an automatic scanner, the values of two devices that went through dose adjustment process had a statistical difference in TLD and PLD measurements under each filming conditions which were 70kVp, 200mA, 0.012sec and 42kVp, 100mA, and 0.012sec (p<0.001 and p<0.001 respectively). As for the difference of measurement value between DAP and the two particles under 70kVp, 200mA, 0.012sec filming condition, TLD had a value lower than DAP average value by $44.2mGy{\cdot}cm^2$ and PLD had a value of $246.8mGy{\cdot}cm^2$ which was lower than DAP average value by $15.5mGy{\cdot}cm^2$, while under 42kVp, 100mA, 0.012sec filming condition, TLD had a value lower than DAP average value by $17.9mGy{\cdot}cm^2$ and PLD had a value of $82.6mGy{\cdot}cm^2$ which was lower than DAP average value by 7.6$mGy{\cdot}cm^2$. Also, compared to PLD, each of 10 devices measured dose value in TLD had a larger deviation between the particles, and for a reproducibility test which repeatedly measured one particle, PLD had ${\pm}1%$ which was lower than TLD's ${\pm}2%$. As such, PLD had a superior performance result in dose measurement capacities aspect compared to TLD, and therefore we could verify that PLD is more appropriate and advantageous in managing radiation-related task performing worker's personal radiation exposure management in the diagnostic radiation field.

Protective Effects of Chemical Drugs on the Course of Uranium-induced Acute Renal Failure (우라늄오염에 의한 신부전증에 미치는 제염제의 방호효과)

  • Kim, Tae-Hwan;Chung, In-Yong;Kim, Sung-Ho;Kim, Kyeng-Jung;Bang, Hyo-Chang;Yoo, Seong-Yul;Chin, Soo-Yil
    • Journal of Radiation Protection and Research
    • /
    • v.15 no.2
    • /
    • pp.27-39
    • /
    • 1990
  • Appreciable radiation exposures certainly were occurred in the reactor burn-up, the nuelear fall-out and the surroundings of nuclear installations with radioactive effluents. Therefore, radioactive nuclides is not only potentially hazardous to workers of nuclear power plants and related industrials, but also the wokers who handle radioactive nuclides in biochemical research and nuclear medicine diagnostics. And in the case of occurring the nuclear accidents, the early medical treatment of radiation injury should be necessary but little is established medical procedures to decontaminate the victims of internal contamination of radioactive nuclides in korea. Accordingly, to achieve the basic data for protective roles and medical treatment of radiation injury, the present studies were carrid out to evaluate the decontamination of uranium by the chemical drugs. The results observed were summarized as follows: 1. The combined treatmet group of sodium bicarbonate and saline with uranyl nitrate injection simultaneously and the dithiothreitol group that was administered 30 minutes after uranyl nitrate injection were increased significantly in the change of body weight than uranyl nitrate-only group (P<0.005). 2. All the experimental groups were increased the fluid intake and urine volume on the uranyl nitrate-induced acute renal failure. but the combined treatment group of sodium bicarbonate and saline with uranyl nitrate injection simultaneously and the dithiothreitol group that was administered 30 minutes after uranyl nitrate injection have the higher increment of fluid intake and urine volume (P<0.05). 3. When sodium bicarbonate and saline was treated with uranyl nitrate injection simultaneously. and dithiothreitol was administered 30 minutes after uranyl nitrate injection. there was significantly reduced in BUN concentration (P<0.01). 4. When dithiothreitol was administered 30 minutes after uranyl nitrate injection. there was reduced more significantly on the increment of serum creatinine concentration than that observed in uranyl nitrate-only group(P<0.01). but when the combined treatment of sodium bicarbonate and saline with uranyl nitrate simultaneously, there was still. albeit much less marked. decrease in serum creatinine concentration. 5. The sodium bicarbonate and saline was treated with uranyl nitrate simultaneously and dithiothreitol was administered at 30 minutes after uranyl nitrate were excreted markedly higher urine creatinine concentration than the uranyl nitrate-only group. 6. Uranyl nitrate has been used in experimental animals to produce hydropic degeneration and swelling of proximal tubules, disappearance of microvilli and brush border or necrosis in the kidney and centrilobular necrosis, congestion, and telangiectasia of the liver. When the sodium bicarbonate and saline was treated with uranyl nitrate simultaneously, and dithiothreitol was administered. 30 minutes after uranyl nitrate, there was more marked the protective effect than uranyl nitrate-only group. Finally, if the sodium bicarbonate and saline may administered as quickly as possible each time that some risk for internal contamination, with uranium, and dithiothreitol is administered 30 minutes after uranium contamination, there ameliorates the course of uranyl nitrate-induced acute renal failure.and this effect is assocciated with prevention of uranium (heavy metal)-induced alterations in BUN, serum creatinine, urine creatinine, fluid intake, urine volume and body weight.

  • PDF

Self Production of Radioisotope and Radiopharmaceuticals Divider (방사성동위원소 및 방사성의약품 분주장치의 자체제작)

  • Hong, Sung-Tack;Park, Kwang-Seo;Kim, Seok-Ki;Won, Woo-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.177-180
    • /
    • 2010
  • Purpose: As PET test came to be covered by the pay system of medical insurance (July 1, 2006) and the needs for it becoming increased for laboratory purpose, it became necessary to purchase expensive medical equipments to solve those problems. However, as most of equipments that are operated by cyclotron are very expensive as to amount from tens of millions up to hundreds of millions of won, it is difficult to purchase those equipments from the point of medical organizations. It may be possible to self manufacture those equipments with least costs if their parts functions that meets the operators demands. The Nuclear Medicine department of National Cancer Center (NCC) is trying to manufacture and use equipments that can be made with least costs, including introducing 2 medical equipments that can improves the operator's works. Materials and Methods: Example 1: Self production of radioisotope($^{18}F$) divider was fabricated. The NCC's Nuclear Medicine department acquired one acrylic panel, seven 3-way valve, tubing etc. that can be found in the market to make the main body of divider in cooperation with biomedical engineering, and placed them inside hot cell, and installed switching box outside of hot cell to make it possible to control them from outside. This main body of divider were placed in radioisotope transfer line that are manufactured in the cyclotron. Example 2: Self production of $^{18}F$-FDG automated divider was fabricated. The NCC's Nuclear Medicine department used cavro pump syringe that consists the main body of divider in cooperation with biomedical engineering, biomedical engineering developed programs that divides a certain amount. $^{18}F$-FDG automated divider is placed inside hot cell, and cable chords were used in the equipment, and then it was connected to PC outside hot cell to make it possible to control the $^{18}F$-FDG automated divider. Results: From the NCC's Nuclear Medicine department tests that were carried out from March, 2007 until now, we found out that radioisotope can be sent to radiopharmaceuticals composite module we want, and from the tests that are carried out at NCC's Nuclear Medicine department using $^{18}F$-FDG automated divider since August, 2009 it was possible to distribute radiopharmaceuticals into vial intended. Conclusion: Through the two examples above, we found out that costs can be reduced by self manufacturing expensive equipments from NCC's cyclotron room with least costs. Also, it decreased radiation exposure dose on workers, and set up problem solving processes in cooperation with lots of parties related.

  • PDF