• Title/Summary/Keyword: Radiation pattern

Search Result 1,152, Processing Time 0.024 seconds

A Numerical Analysis Study on the Estimation of the 3D Underwater Radiated Noise Pattern using the Hull Vibration Signals (선체진동신호를 이용한 3차원 수중방사소음 패턴 산출에 대한 수치해석 연구)

  • Yi, Jong-Ju;Kang, Myung-Hwan;Han, Seung-Jin;Bae, Soo-Ryong;Kim, Jae-Ho;Jung, Woo-Jin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.10
    • /
    • pp.770-779
    • /
    • 2014
  • In this study, a numerical estimation method for 3D underwater radiated noise pattern using hull vibration and total acoustic power of the vibrating structure in the far-field is proposed. The underwater radiated noise pattern is known to be predicted using the vibration signals and radiation efficiency of each surface patch. But it is very difficult to know radiation efficiency of each surface patch which is one of important factors to calculate the 3D underwater radiated noise pattern. Instead of using radiation efficiency of each patch, the underwater radiated noise level is modified with the total acoustic power of the vibrating structure. The suggested estimation method for underwater radiated noise pattern is discussed with numerical model.

Effect of a Finite Substrate on the Radiation Characteristics of a Linear Phased Array Antenna Positioned along the E-plane (유한한 기판 크기가 E-평면으로 배열된 선형 위상 배열 안테나의 방사 특성에 미치는 영향)

  • Kim, Tae-Young;Kim, Gun-Su;Yoon, Young-Min;Kim, Boo-Gyoun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.5
    • /
    • pp.46-53
    • /
    • 2011
  • The effect of a finite substrate on the radiation characteristics of a linear 7-element array antenna positioned along the E-plane is investigated. Active reflection coefficients and average active element patterns are simulated for various substrate sizes. The E-plane radiation pattern of a fully excited array for various scan angles is correlated with the active reflection coefficient and average acitive element pattern. The effect of E-plane substrate size on the radiation characteristics of a linear array along the E-plane is larger than that of H-plane substarte size.

Use of Sleeve Baluns to Improve the Radiation Pattern of a Broadband Biconical Antenna (슬리브 발룬을 활용한 광대역 바이코니컬 안테나의 방사패턴 개선 연구)

  • Soily, Srabonty;Kim, Dong-Woo;Oh, Soon-Soo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.4
    • /
    • pp.563-570
    • /
    • 2022
  • We designed a biconical antenna with sleeve baluns that exhibited an improved radiation pattern from 3-40 GHz. In the antenna, the edges of the ring of the upper cone are blended to a cylinder. Sleeve baluns operating at specific frequencies are connected to the antenna to minimize leakage currents on the surface of the feeding coaxial cable. The radiation pattern was improved with the sleeve baluns, and the angular 3-dB beamwidth ranged from 67.1-101.1° over 3-40 GHz, which is much broader than the 21-99° of the conventional antenna.

A Study on Monopole Antenna Radiation Pattern inside Vehicle (차량 내부에서의 모노폴 안테나 방사패턴 연구)

  • Lee, Tae-Hak;Pyo, Seong-Min;Park, Sang-Myeong;Kim, Young-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.11
    • /
    • pp.4537-4542
    • /
    • 2010
  • In this paper, the antenna radiation pattern inside the vehicle is presented for observing the change occurring in non-anechoic environment using monopole antenna. The environment for radio communication can be affected by antenna characteristic variation inside the small space existing multi reflection waves. To perform simulation and measurement about antenna radiation pattern, the radio frequency bands for GPS and Wibro services expected to use inside the vehicle is selected. The simulation is based on the ray-tracing method and the radiation pattern is measured inside the vehicle and in free space using monopole antenna having those frequency bands. In accordance with the measurement and simulation results, when two antennas are put inside the vehicle, the omni-directional characteristic of the antenna is maintained but the received power is increased than free space case and the difference between the each case of measurements is increased as the operating frequency is increased.

Effect of a Finite Substrate Size on the Radiation Characteristics of Two-Element Linear E-plane Array Antennas (유한한 기판 크기가 2소자 E-평면 선형 배열 안테나의 방사 특성에 미치는 영향)

  • Yoon, Young-Min;Kim, Boo-Gyoun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.12
    • /
    • pp.95-110
    • /
    • 2012
  • The effect of a finite substrate size on the radiation characteristics of a two-element linear E-plane array antenna using microstrip patch antennas is investigated. The average active element pattern characteristics of two-element E-plane array antennas printed on different dielectric constant substrates with various substrate sizes and element spacings are analyzed. Using the average active element pattern, the radiation pattern characteristics of the array antenna versus scan angle is analyzed. The simulation results show that the diffracted fields of surface waves from substrate edges have a significant effect on the radiation characteristics of a 2-element E-plane array antenna. The distance between the center of patch antenna and the substrate edges on the E-plane for the enhancement of radiation characteristics of the array antenna is about $0.35{\lambda}_0$.

Signal Characteristics of Ultra-high Frequency Radiation from Partial Discharge in Insulation Oil (절연유에서 부분방전에 의한 극초단파 신호 특성분석)

  • Ju, Hyoung-Jun;Goo, Sun-Geun;Park, Ki-Jun;Han, Ki-Seun;Yoon, Jin-Yul
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.1
    • /
    • pp.56-59
    • /
    • 2008
  • We have designed 4 types(void in insulation paper, protrusion electrode, floating electrode, surface discharge) of partial discharge(PD) defect to simulate typical faults found in oil filled power transformers. Ultra-high frequency(UHF) radiation due to PD was measured using a UHF measuring system and a conventional PD measuring system, simultaneously. Electromagnetic radiation spectra of these defects show UHF radiation up to about 1.5-2 GHz range. The phase resolved partial discharge(PRPD) patterns of UHF radiation from the PD defects were also measured and the pattern reveals distinct feature for each defect types. The UHF measuring could be used to detect PDs in oil filled transformers and analysis of the PRPD pattern should provide useful information on origin of PD signal.

A Prediction of Radiation Power for the Planar Array Acoustic Transducer Considering Mutual Coupling Effects (상호 간섭 영향을 고려한 평면 배열형 음향 트랜스듀서의 방사 출력 예측)

  • Lee, Jong-Kil;Seo, In-Chang
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.17-22
    • /
    • 1996
  • Planar array of acoustic transducer is normally used in a sonar system. Acoustic radiation makes beam pattern in underwater uses. The main source of the beam pattern is due to the transducer array. Therefore, estimation of the acoustic radiated power is necessary to predict the performance and efficiency of the transducer. As an example of the acoustic radiation power, nine acoustic transducers mounted to a rigid infinite baffle are considered in a theoretical model. Each piston's acoustic radiation consists of self- and mutual-radiation impedances. Total radiation impedances and acoustic radiation power of the transducers are extracted using on the theory of an equivalent electric circuit. The theoretical results reveal that acoustic radiation power of the transducer depends on the mutual coupling effects.

  • PDF

Preliminary Study for Development of Pattern Identification Tool for Radiation Pneumonitis (방사선폐렴 변증(辨證)도구 개발을 위한 기초연구)

  • Kim, Jae-hyo;Bhang, Yeon-hee;Do, Ha-yoon;Ahn, Jun-mo;Kim, Kwan-il;Lee, Beom-joon;Jung, Sung-ki;Jung, Hee-jae
    • The Journal of Internal Korean Medicine
    • /
    • v.38 no.1
    • /
    • pp.32-47
    • /
    • 2017
  • Objective: The purpose of this study was to develop a standard tool for pattern identification of radiation pneumonitis. Methods: Textbooks, published studies, and references with comments about patterns were reviewed. Through the Delphi method, we determined pattern identifications based on advice from a committee of experts composed of 13 Korean respiratory internal medicine professors. Results: Using the Delphi method, four pattern identifications were chosen: Qi Deficiency (氣虛), Yin Deficiency (陰虛), Heat Toxin (熱毒), and Phlegm Dampness (痰濕). The tool was developed in a question-and-answer format with 35 questions. Conclusions: A pattern identification tool that can discriminate the patterns of radiation pneumonitis for standardized diagnosis was developed through expert consultation. Further study of its validity and reliability is necessary.